3D Printing-Based Ultrafast Mixing and Injecting Systems for Time-Resolved Serial Femtosecond Crystallography (시간 분해 직렬 펨토초 결정학을 위한 3차원 프린팅 기반의 초고속 믹싱 및 인젝팅 시스템)

  • Ji, Inseo;Kang, Jeon-Woong;Kim, Taeyung;Kang, Min Seo;Kwon, Sun Beom;Hong, Jiwoo
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.300-307
    • /
    • 2022
  • Time-resolved serial femtosecond crystallography (TR-SFX) is a powerful technique for determining temporal variations in the structural properties of biomacromolecules on ultra-short time scales without causing structure damage by employing femtosecond X-ray laser pulses generated by an X-ray free electron laser (XFEL). The mixing rate of reactants and biomolecule samples, as well as the hit rate between crystal samples and x-ray pulses, are critical factors determining TR-SFX performance, such as accurate image acquisition and efficient sample consumption. We here develop two distinct sample delivery systems that enable ultra-fast mixing and on-demand droplet injecting via pneumatic application with a square pulse signal. The first strategy relies on inertial mixing, which is caused by the high-speed collision and subsequent coalescence of droplets ejected through a double nozzle, while the second relies on on-demand pneumatic jetting embedded with a 3D-printed micromixer. First, the colliding behaviors of the droplets ejected through the double nozzle, as well as the inertial mixing within the coalesced droplets, are investigated experimentally and numerically. The mixing performance of the pneumatic jetting system with an integrated micromixer is then evaluated by using similar approaches. The sample delivery system devised in this work is very valuable for three-dimensional biomolecular structure analysis, which is critical for elucidating the mechanisms by which certain proteins cause disease, as well as searching for antibody drugs and new drug candidates.

B-mode ultrasound images of the carotid artery wall: correlation of ultrasound with histological measurements

  • Gamble G.;Beaumont B.;Smith H.;Zorn J.;Sanders G.;Merrilees M.;MacMahon S.;Sharpe N.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02b
    • /
    • pp.169-179
    • /
    • 1994
  • B-mode ultrasound is being used to assess carotid atherosclerosis in epidemiological studies and clinical trials. Recently the interpretation of measurements made from ultrasound images has been questioned. This study examines the anatomical correlates of B-mode ultrasound of carotid arteries in vitro and in situ in cadavers. Twenty-seven segments of human carotid artery were collected at autopsy. pressure perfusion fixed in buffered 2.5% gluteraldehyde and 4% paraformaldehyde and imaged using an ATL UM-8 (10 MHz single crystal mechanical probe). Each artery was then frozen, sectioned and stained with van Gieson or elastin van Gieson. The thickness of the intima. media and adventitia were measured 'to an accuracy of 0.01 mm from histological sections using a calibrated eye graticule on a light microscope. Shrinkage artifact induced by histological preparation was determined to be 7.8%. Digitised ultra sound images of the artery wall were analysed off-line. The distance from the leading edge of the first interface ($LE_{1}$) to the leading edge of the second interface ($LE_2$) was measured using a dedicated programme. $LE_{1}$-$LE_{2}$ measurements were correlated against histological measurements corrected for shrinkage. Mean values for the far wall were: ultra sound $LE_{1}$-$LE_{2}$ (0.97 mm, S.D. 0.26), total wall thickness (1.05 mm, S.D. 0.37), adventitia (0.35 mm, S.D. 0.16), media (0.61 mm, S.D. 0.18). intima (0.09 mm, S.D. 0.13). Ultrasound measurements corresponded best with total wall thickness, rather than elastin or the intima-media complex. Excision of part of the intima plus media or removal of the adventitia resulted in a corresponding decrease in the $LE_{1}$-$LE_{2}$ distance of the B-mode image. Furthermore. increased wall thickness due to intimal atherosclerotic thickening correlated well with $LE_{1}$-$LE_{2}$ distance of the B-mode images. B-mode images obtained from the carotid arteries in situ in four cadavers also corresponded best with total wall thickness measured from histological sections and not with the thickness of the intima plus media. In conclusion, the $LE_{1}$-$LE_{2}$ distance measured on B-mode images of the carotid artery best represents total wall thickness of intima plus media plus adventitia and not intima plus media alone.

  • PDF

Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰)

  • Choi, Yong;Kim, Jong-Ho;Kim, Joon-Young;Im, Ki-Chun;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Joo, Koan-Sik;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.82-93
    • /
    • 2000
  • Purpose: We characterized the signals obtained from the components of a small gamma camera using Nal(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. Materials and Methods: The small gamma camera system consists of a Nal(Tl) crystal ($60{\times}60{\times}6mm^3$) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y -). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. Results: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately $8{\times}10^3$ counts/sec/${\mu}Ci$. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and $^{99m}Tc$ point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing $2{\sim}7mm$ diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.

  • PDF

Efficient Red-Color Emission of InGaN/GaN Double Hetero-Structure Formed on Nano-Pyramid Structure

  • Go, Yeong-Ho;Kim, Je-Hyeong;Gong, Su-Hyeon;Kim, Ju-Seong;Kim, Taek;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.174-175
    • /
    • 2012
  • (In, Ga) N-based III-nitride semiconductor materials have been viewed as the most promising materials for the applications of blue and green light emitting devices such as light-emitting diodes (LEDs) and laser diodes. Although the InGaN alloy can have wide range of visible wavelength by changing the In composition, it is very hard to grow high quality epilayers of In-rich InGaN because of the thermal instability as well as the large lattice and thermal mismatches. In order to avoid phase separation of InGaN, various kinds of structures of InGaN have been studied. If high-quality In-rich InGaN/GaN multiple quantum well (MQW) structures are available, it is expected to achieve highly efficient phosphor-free white LEDs. In this study, we proposed a novel InGaN double hetero-structure grown on GaN nano-pyramids to generate broad-band red-color emission with high quantum efficiency. In this work, we systematically studied the optical properties of the InGaN pyramid structures. The nano-sized hexagonal pyramid structures were grown on the n-type GaN template by metalorganic chemical vapor deposition. SiNx mask was formed on the n-type GaN template with uniformly patterned circle pattern by laser holography. GaN pyramid structures were selectively grown on the opening area of mask by lateral over-growth followed by growth of InGaN/GaN double hetero-structure. The bird's eye-view scanning electron microscope (SEM) image shows that uniform hexagonal pyramid structures are well arranged. We showed that the pyramid structures have high crystal quality and the thickness of InGaN is varied along the height of pyramids via transmission electron microscope. Because the InGaN/GaN double hetero-structure was grown on the nano-pyramid GaN and on the planar GaN, simultaneously, we investigated the comparative study of the optical properties. Photoluminescence (PL) spectra of nano-pyramid sample and planar sample measured at 10 K. Although the growth condition were exactly the same for two samples, the nano-pyramid sample have much lower energy emission centered at 615 nm, compared to 438 nm for planar sample. Moreover, nano-pyramid sample shows broad-band spectrum, which is originate from structural properties of nano-pyramid structure. To study thermal activation energy and potential fluctuation, we measured PL with changing temperature from 10 K to 300 K. We also measured PL with changing the excitation power from 48 ${\mu}W$ to 48 mW. We can discriminate the origin of the broad-band spectra from the defect-related yellow luminescence of GaN by carrying out PL excitation experiments. The nano-pyramid structure provided highly efficient broad-band red-color emission for the future applications of phosphor-free white LEDs.

  • PDF

The Evaluation of Scattering Effects for Various Source Locations within a Phantom in Gamma Camera (감마카메라에서의 팬텀 내 선원 위치 변화에 따른 산란 영향 평가)

  • Yu, A-Ram;Lee, Young-Sub;Kim, Jin-Su;Kim, Kyeong-Min;Cheon, Gi-Jeong;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.216-224
    • /
    • 2009
  • $^{131}I$ is a radiological isotope being used widely for treatment of cancer as emitting gamma-ray and it is also applied to estimate the function of thyroid for its accumulation in thyroid. However, $^{131}I$ is more difficult to quantitate comapred to $^{99m}Tc$, because $^{131}I$ has multiple energy gamma-ray emissions compared to $^{99m}Tc$ which is a mono energetic gamma-ray source. Especially, scattered ray and septal penetration resulted by high energy gamma ray have a bad influence upon nuclear medicine image. The purpose of this study was to estimate scatter components depending on the different source locations within a phantom using Monte Carlo simulation (GATE). The simulation results were validated by comparing with the results of real experiments. Dual-head gamma camera (ECAM, Chicago, Illinois Siemens) with high energy, general-purpose, and parallel hole collimators (hole radius: 0.17 cm, septal thickness: 0.2 cm, length: 5.08 cm) was used in this experiment. The NaI crystal is $44.5{\times}59.1\;cm$ in height and width and 0.95 cm in thickness. The diameter and height of PMMA phantom were 16 cm and 15 cm, respectively. The images were acquired at 5 different locations of $^{131}I$ point source within the phantom and the images of $^{99m}Tc$ were also acquired for comparison purpose with low energy source. The simulation results indicated that the scattering was influenced by the location of source within a phantom. The scattering effects showed the same tendency in both simulation and actual experiment, and the results showed that the simulation was very adequate for further studies. The results supported that the simulation techniques may be used to generalize the scattering effects as a function of a point source location within a phantom.

  • PDF

Combination Effect of Various Freezing and Thawing Techniques on Quality and Nutritional Attributes of Onions (다양한 냉·해동 방법에 따른 양파의 이화학적 특성 및 영양성분 변화)

  • Jung, You-Kyoung;Jang, Min-Young;Hwang, In-Guk;Yoo, Seon-Mi;Min, Sang-Gi;Jo, Yeon-Ji;Chun, Ji-Yeon;Choi, Mi-Jung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.10
    • /
    • pp.1492-1503
    • /
    • 2015
  • This study evaluated the combination effect of various freezing and thawing techniques on the quality and nutritional aspects of onions. Onions were frozen by natural air convection freezing (NCF), air blast freezing (ABF), and liquid nitrogen freezing (LNF). Onions were frozen for 76 min by NCF, 9 min by ABF, and 9 min by LNF. The freezing treatment was stopped when the core temperature reached $-12^{\circ}C$ for NCF and ABF, and $-120^{\circ}C$ for LNF. Frozen samples were thawed through natural air convection thawing, running water thawing, sonication thawing (ST), or microwave thawing. The quality and nutritional aspects of frozen-thawed onions were evaluated by measuring thawing loss, pH, texture, water content, color, and SEM image. ST was found to cause the least loss in onion sample among the tested thawing methods, whereas the freezing methods did not cause any significant loss. In our experiment, thawing is found to be a more critical technique when compared to that of freezing. There were no clear quantifications or trends of pH and water content among different freezing and thawing techniques. The highest total color difference (${\Delta}E$) was observed in the NCF sample. For morphological observation, ABF gave the smallest ice crystal size, as well as minimum cell collapse. Loss of vitamin C, free sugar, and organic acid content was lower in the ABF and ST sample, when compared to other trials. In our study, we found that combination of ABF and ST could preserve the quality and nutritional aspects of frozen-thawed onions better than other methods.

Effect of Sodium Fluoride Varnish and Potassium Iodide on Remineralization Efficacy of Silver Diamine Fluoride (불화나트륨 바니쉬와 요오드화 칼륨이 Silver Diamine Fluoride의 재광화 효과에 미치는 영향)

  • Lee, Kunho;Ahn, Junyong;Kim, Jong Soo;Han, Miran;Lee, Joonhaeng;Shin Jisun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.467-475
    • /
    • 2021
  • The purpose of this study was to compare the effect of sodium fluoride(NaF) varnish and potassium iodide(KI) on remineralization efficacy of silver diamine fluoride(SDF) by measuring microhardness and evaluating surface morphology by scanning electron microscope(SEM). Artificial caries lesions were induced on extracted primary molars and vickers microhardness was measured. Specimens were randomly separated into 4 groups for treatment. The specimens in group I were treated with SDF, group II with NaF varnish after SDF, group III with KI after SDF and group IV with distilled water. After 8 days of pH cycling, vickers microhardness was measured and difference before and after treatment was calculated. For SEM, 2 samples were evaluated respectively after enamel polishing, lesion formation and after pH cycling. Group III showed highest increase in microhardness. Group I showed higher increase in microhardness than Group II but without statistical difference. Group IV showed lowest increase in microhardness value among 4 groups. On SEM image, group I, II and III showed smoother and less irregular surface compared to group IV. Amorphous crystal pellicles were observed in group III. In conclusion, SDF, SDF and NaF, SDF and KI groups showed smoother surface and increase in microhardness suggesting the possibility that remineralization effect might take place in oral conditions. In addition, in limited conditions of this study, applying NaF varnish after SDF did not increase the remineralization efficacy of SDF while KI significantly increased the remineralization efficacy of SDF. However, additional study considering various conditions that might affect demineralization and remineralization in clinical situations need to be conducted.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.