• Title/Summary/Keyword: Image transmission

검색결과 1,233건 처리시간 0.034초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

옥천대의 석류석데 변성암에서 산출되는 백운모, 녹니석 및 흑운모의 Intergrowth와 Interlayering (Intergrowth and Interlayering of Muscovite, Chlorite, and Biotite in a Garnet Zone Metamorphic Rock of the Ogcheon Belt, South Korea)

  • Yeong Boo Lee;Jung Hoo Lee;Chang Whan Oh
    • 한국광물학회지
    • /
    • 제15권2호
    • /
    • pp.122-131
    • /
    • 2002
  • 옥천대 변성 이질암에 분포하는 백운모, 녹니석 및 흑운모는 각기 다른 크기에서 intergrowth와 interlayer 된 것을 전자현미분석(EPMA) 배면 산란 전자상(BEI) 관찰 및 투과 전자현미경(TEM)을 이용한 lattice fringe 상 관찰을 통한 연구에서 밝혔다. 이들 세 광물은 편광현미경 관찰에서도 intergrow된 것이 관찰되며 EPMA 분해능 이하의 크기에서는 interlayer된 것으로 보인다. 다시 말하면, EPMA 분석 자료는 흔히 백운모/녹니석(M/C), 흑운모/녹니 석(B/C), 백운모/파이로필라이트/녹니석(M/Py/C), 흑운모/파이로필라이트/녹니석(B/Py/C) 또는 흑운모/백운모/녹니석(B/M/C)과 같이 두 개 이상의 phyllosilicate 광물의 혼합 형태로 나타난다. BEI 관찰에서는 세 광물(백운모, 녹니석 및 흑운모)이 하나의 입자 안에서 다양한 크기로 섞여 있는 것으로 나타나며, TEM lattice fringe 상 관찰과 제한 시야 전자 회절상 관찰에 의하면 이들 세 광물 사이의 interlayering은 석류석대 변성암에서까지 관찰된다. TEM 관찰 결과 녹니석대 변성암에서는 M/C와 함께 7-$\AA$ layer(사문석, 녹니석의 전신)가 -$10\AA$ layer(백운모) 내에 100~200 $\AA$ 크기로 inter-layer된 것이 밝혀졌다. 흑운모대 변성암으로 가면 7-$\AA$ layer는 크기와 발견 횟수가 감소하고 10-$\AA$ layer는 녹니석(14 $\AA$)과 개별 layer 수준에서 interlayer된다. 석류석대 변성암에서는 7-$\AA$ layer는 더 이상 관찰되지 않으며 10-$\AA$ layer(흑운모)가 녹니석과 50~100 $\AA$ 크기로 interlayer된다.(BEI, TEM). 석류석대 변성암에서는 비교적 큰 크기(1000~2000 $\AA$)의 intergrowth가 흔히 관찰된다. 그러나 세 개의 변성대 암석은 모두 TEM 관찰에서 7-, 10-, 또는 14-$\AA$ layer들이 몇 개의 layer 단위에서 서로 interlayer된 것을 보여준다. 이와 같은 결과는 백운모, 녹니석 및 흑운모와 같은 변성 광물들이 비평형 광물 반응으로 만들어 졌으며 그 결과 불균질한 광물로 되었다는 것을 암시한다.

합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : II. 선형파면 송신 방법 (Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: II. Linear Wave Front Transmission Approach)

  • 김강식;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권5호
    • /
    • pp.403-414
    • /
    • 2004
  • 본 논문의 동반논문에서는 측방향으로는 동적집속, 고도방향으로는 합성구경 기법을 이용하여 빔을 집속함으로써 모든 영상 점에 대해 측방향과 고도방향 모두 동적집속된 효과를 얻을 수 있는 합성구경 기반의 교차어레이를 사용한 3차원 영상화 기법을 제안하였다. 하지만 구면파를 이용한 합성구경 기법은 초음파의 회절현상으로 인해 관찰깊이가 증가함에 따라 빔폭이 증가하여 원거리에서 해상도가 크게 저하되는 단점을 갖는다. 또한 제안된 방법은 송신시 하나의 변환소자만을 사용하므로 송신전력 또한 제한되게 된다. 이를 극복하기 위해 본 논문에서는 선형파면과 합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법을 제안한다. 제안한 방법에서는 송신시 수평평면에 대해 각기 다른 편향각도 갖는 선형파면을 송신하고, 반사된 신호들을 측방향으로 놓인 일차윈 수신어레이의 전체 구경을 이용하여 수신하게 된다. 수신시 측방향으로는 동적집속, 고도방향으로는 합성구경 기법을 이용하여 빔을 집속함으로써 모든 영상 점에 대해 측방향과 고도방향 모두 동적집속된 효과를 얻을 수 있다. 제안한 방범은 구연파 기반의 합성구경 기법과는 달리 깊은 영상 영역에서 고도방향으로 균일한 해상도를 제공하는 제한회절 특성을 가지는 것을 수학적 해석과 음장 모사실험을 통해 확인하였다. 특히 선형파면 기반의 합성구경 기법은 구면파 기반의 합성구경 기법과 달리 송신어레이의 전체구경을 사용하여 제한된 수의 초음파 송수신과정을 통해 하나의 입체 영상을 얻을 수 있으므로 높은 송신전력과 고해삼도를 갖는 3차원 영상을 위한 고속주사에 적합하다.물체의 크기, 위치 및 깊이를 찾는 알고리즘을 시스템에 적용하여 알고리즘을 실험적으로 검증하고 유방암의 조기 검진을 위해 활용이 가능한 시스템을 개발하는 연구를 수행할 예정이다.면활성 변화 능력이 월등히 향상된 것으로 추정된다.timate the dielectric properties during the whole cure, the Havriliak-Negami model was considered and modified with the strong effect of ionic conductivity. The changes of $varepsilon$′ and $varepsilon$" were well estimated with this modified Havriliak-Negami model.05). 상기의 결과를 토대로, 성장과 전어체내 지방산조성에 있어서 뱀장어 치어의 사료내 EPA와 DHA의 첨가효과 미약한 것으로 판단되며, 사료내 LNA (n-3)와 LA(n-6) HUFA을 각각 0.35%, 0.65% 첨가했을 때 WG, SGR, FE, PER이 가장 높았으나, 이전의 실험(Takeuchi, 1980)과 동일한 수준인 n-3와 n-6를 각각 0.5%씩 첨가한 실험구와는 유의적인 차이를 보이지 않았다. 이렇게 볼 때, 뱀장어 치어의 필수지방산은 LNA (n-3), LA (n-6)이고, 그 적정수준은 각각 0.35-0.5%, 0.5-0.65%임을 보여준다.George W, Bush)가 새로운 지도자로 취임하여 얼마 되지 않은 2001년 9월 11일 사상

만취정(晩翠亭)의 장소 전승과 원형경관향유 양상 (A study on the Meaning Contact of ManChwi Pavilion's Place Transmission and Sense of Prototype Landscape)

  • 이승연;신상섭;강병선
    • 한국전통조경학회지
    • /
    • 제34권3호
    • /
    • pp.38-49
    • /
    • 2016
  • 본 연구는 기문과 시문이 장소성의 함의와 원형경관의 유추 및 향유양상을 탐색할 수 있는 근거가 될 수 있다는 전제로 임실 만취정의 원래 위치 및 이건된 위치에서 입지 및 원형경관을 탐색하고 그 의미를 추론하였다. 임실 만취정의 이건 전 후의 장소적 가치와 원형경관 보존을 위해 시도된 연구 결과는 다음과 같다. 첫째, 정자의 당호 만취(晩翠)는 작정자 김위가 자신의 호로 삼았으며, 소나무를 마주보게 심고 만취라 편액하였는데, 시문에 근거하면 푸른 소나무와 같은 꿋꿋한 기개를 상징하고 있다. 특히 정자에 내재된 의미와 도입된 상징식물 등을 살펴보았을 때 당호는 절개, 가문의 장생, 생명력 등을 반영한 것으로 해석된다. 둘째, 만취정은 풍수적으로 강 건너 제비형국과 마주한 사두형에 자리잡아 팽팽한 균형을 갖고 있어 절개와 가문 번영을 염원하는 장소성을 지니고 있다. 한편, 이건된 만취정은 풍수적 복치형(伏雉形) 형국으로 해석되는데, 학문과 가문 번영에 대한 계승노력이 전승되고 있음을 유추할 수 있다. 셋째, 만취정은 1572년에서 1582년 사이에 건립되었으며, 이건은 1880년대 말에 이루어졌을 것으로 추정하였다. 넷째, 만취정은 변치 않는 절개와 가문번영의 염원을 장소적 언어로 대입시켰으나 후손들에 의해 만취 김위의 묘 옆으로 이건 됨으로서 조상 추모, 후손 학문번영이라고 하는 가치이동 양상이 추적된다. 다섯째, 이건된 만취정은 온돌방에 비중을 둔 사계절 활용, 공간 확장성을 고려한 툇마루, 주련의 내용 등으로 볼 때 강학공간으로서의 의미를 공유, 전승한 것으로 추론된다. 여섯째, 제영시에 나타난 소나무, 연못, 식물, 계곡, 시냇물 등을 통해 절개, 지조, 깨긋한 심성, 유유자적한 삶, 자아성찰, 인생무상 등의 의미가 투영되는 경관향유 양상이 드러나고 있다. 마지막으로 십영의 제영 언어는 원운과 차별성이 인정되지만 의미나 감흥을 통해 원운십영이 지닌 원형경관 향유양상은 전승되고 있는바 관련 시문분석에 따른 경관탐색은 원형경관 보존 및 활용을 위한 근거가 될 수 있음을 보여준다.

루테늄이 치환된 SBA-15(Ru-SBA-15)의 질소 및 산소 흡착 거동 (Nitrogen and Oxygen Sorption Behaviors of Ruthenium-Substituted SBA 15(Ru-SBA-15))

  • 서윤아;김형국;신정훈;김일;하창식
    • Korean Chemical Engineering Research
    • /
    • 제47권5호
    • /
    • pp.608-614
    • /
    • 2009
  • 본 연구에서는, 비이온성 삼원공중합체 계면활성제인 $EO_{20}PO_{70}EO_{20}$를 주형으로 사용해, 다양한 Si/Ru 몰 비의 루테늄이 치환된 SBA-15들(Ru-SBA-15)을 합성하였다. 촉매 또는 선택적 흡착제 등으로써의 응용가능성을 검토하기 위해 Ru-SBA-15의 질소 또는 산소 흡착/탈착 거동을 조사하였다. Ru-SBA-15의 기공 크기는 Barrett-Joyner-Halenda(BJH) 및 Broekhoff-de Boer/Frenkel-Halsey-Hill isotherm(BdB-FHH) 방법($D_{BdB-FHH}$)을 이용하여 결정하였다. Si/Ru 비율이 50/1인 Ru-SBA 15의 $D_{BJH}$$D_{BdB-FHH}$는 각각 3.9, 4.7 nm였다. 투과전자현미경(TEM) 관찰에 의해 Si/Ru의 몰비율이 50인 Ru-SBA 15의 기공 크기는 4.7 nm로 나타났고, 이것은 BdB-FHH 방법을 사용한 $N_2$ 흡착 결과와 일치하였다. 산소 흡착/탈착 등온선으로부터 얻은 Brunauer-Emmett-Teller(BET) 기공 표면적은 질소의 흡착/탈착 등온선으로부터의 기공 표면적보다 높았는데, 각각 $612.7m^2/g$, 그리고 $573.3m^2/g$이었다. X선 회절(XRD) 패턴과 TEM 분석에 의해 본 연구에서 합성한 Ru-SBA-15는 잘 정렬된 육방정계 정렬을 가지는 것을 알 수 있었다.

열 이미드화 온도에 따른 작용기화 그래핀/폴리이미드 나노복합재료 (Functionalized Graphene/Polyimide Nanocomposites under Different Thermal Imidization Temperatures)

  • 주지은;장진해
    • 폴리머
    • /
    • 제39권1호
    • /
    • pp.88-98
    • /
    • 2015
  • 폴리이미드(PI) 나노복합체 필름 제조에 사용된 작용기화 4-amino-N-hexadecylbenzamide graphene sheets (AHB-GSs)는 graphene oxide 분산액에 4-amino-N-hexadecylbenzamide(AHB)를 반응시켜 합성하였다. AHB-GS의 주사탐침 현미경(atomic force microscope, AFM) 이미지와 모식도를 통해서 AHB-GS의 평균 두께가 약 3.21 nm임을 확인하였다. PI는 4,4'-biphthalic anhydride와 bis(4-aminophenyl)sulfide를 사용하여 합성하였다. PI 나노복합체는 0-10 wt%의 다양한 함량의 AHB-GS를 용액 삽입(solution intercalation) 방법을 사용하여 합성하였고, 이미드화는 각각 $250^{\circ}C$$350^{\circ}C$까지 열 처리하였다. AHB-GS는 대부분 고분자 매트릭스에 잘 분산되었고 약간 뭉친 것도 있었지만 마이크로미터 수준의 입자는 관찰되지 않았다. TEM으로 관찰하였을 때, 평균적으로 입자의 두께는 10 nm 미만이었다. PI 복합체 필름 중 소량의 AHB-GS만으로도 가스 투과도와 전기 전도도는 향상되었지만, 반대로 유리전이 온도와 초기 분해 온도는 AHB-GS의 함량이 10 wt%까지 증가함에 따라 지속적으로 감소되는 경향을 보였다. 전체적으로는, $250^{\circ}C$까지 이미드화한 PI에 비해 $350^{\circ}C$까지 열처리한 PI 필름이 보다 향상된 특성을 보였다.

국내외 상용 단일모드 광섬유의 감마선 영향 분석 연구 (A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber)

  • 김종열;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.564-567
    • /
    • 2012
  • 광섬유는 신호를 전달하는 통신용 섬유, 물체를 관찰하기 위한 이미지 섬유, 각종 센서용 광섬유로서 원자력분야에서 사용된다. 특히 센서용 섬유로서 라만 산란광을 이용한 온도감지 섬유와 광섬유 브래그 격자을 이용한 온도/스트레인 섬유, 광자기효과를 이용한 광회전센서 섬유 등은 이미 실용화되어 있다. 그러나 광섬유에 방사선을 조사하면 색중심(color center)이 생성되어 광의 투과성이 크게 저하되고, 방사선 환경에서 적용의 제한이 있다. 본 논문에서는 고준위 방사선환경에 대한 광섬유 센서의 적용을 위한 연구로서 Ge가 함유된 일반단일모드 광섬유에 대한 감마선 조사에 따른 전송손실 특성 평가를 수행하였다. 시험에 사용된 방사선원은 $Co^{60}$ 감마선원으로, 총 4시간동안 0.5kGy/hr, 2kGy/hr, 8kGy/hr의 선량률(dose rate)로 조사하였다. 그 결과 감마선조사에 의한 단일모드 광섬유의 전송손실이 뚜렷하게 나타났고, 동일 누적선량에서 선량률이 클수록 전송손실이 증가하는 선량률 효과와 조사 후 광섬유의 전송손실이 클수록 손실 회복율이 증가하는 열화(annealing) 특성을 보였다. 본 시험결과는 향후 광섬유의 내방사화 연구의 기초자료로 활용할 계획이다.

  • PDF

열차 경로 패턴기반 애니메이션 성능 개선 기술 개발 (Technology Development for Improving Animation Performance Based on Train Route Patterns)

  • 이덕희;양원모;김용일;양윤희;신용태
    • 한국ITS학회 논문지
    • /
    • 제11권5호
    • /
    • pp.136-146
    • /
    • 2012
  • IT를 이용한 시뮬레이션 및 가상현실 기술이 발전하면서 시뮬레이션 결과를 사용자에게 효과적으로 전달하기 위한 애니메이션 기술에 대한 관심이 증가하고 있다. 애니메이션에 대한 재생품질, 재생속도, 입출력 속도, 저장공간 축소 등애니메이션 성능을 개선하기 위한 다양한 노력이 있었다. 그러나 기존 연구는 대부분 애니메이션 영상에 대한 프레임별 이미지 압축에 초점을 맞추고 있다. 애니메이션의 저장용량 및 재생 속도를 획기적으로 개선하기 위해서는 애니메이션 자료를 벡터화 하고 시간적 공간적 중복성을 제거해야 한다. 본 연구는 애니메이션 자료에 대한 계층화, 벡터화를 통해 애니메이션 자료구조를 근본적으로 개선하였으며, 열차 이동경로 기반한 애니메이션 자료의 패턴화를 통해 애니메이션 자료의 시간적 공간적 중복성을 제거하여 저장공간을 현저히 축소하였고 입출력 속도 및 재생속도를 획기적으로 개선하였다. 실험결과 애니메이션 벡터화 이후 추가적인 패턴화를 통해 저장공간이 80%이상 축소되었으며 입출력 속도가 약 4배 향상되었다. 이러한 패턴화 기술은 객체의 이동경로가 존재하는 다양한 시뮬레이션 시스템의 애니메이션 자료 저장방식으로 활용될 수 있으며, 아주 작은 애니메이션 자료 전송량으로 인해 사용자 맞춤형 애니메이션을 제공하기 적합한 기술로 활용될 수 있을 것이다.

HEVC 복호기에서의 타일, 슬라이스, 디블록킹 필터 병렬화 방법 (Tile, Slice, and Deblocking Filter Parallelization Method in HEVC)

  • 손소희;백아람;최해철
    • 방송공학회논문지
    • /
    • 제22권4호
    • /
    • pp.484-495
    • /
    • 2017
  • 최근 디스플레이 기기의 발전과 기가 네트워크 등의 전송 대역폭 확대로 인해 대형 파노라마 영상, 4K Ultra High-Definition 방송, Ultra-Wide Viewing 영상 등 2K 이상의 초고해상도 영상의 수요가 폭발적으로 증가하고 있다. 이러한 초고해상도 영상은 데이터양이 매우 많기 때문에 부호화 효율이 가장 높은 High Efficiency Video Coding(HEVC) 비디오 부호화 표준을 사용하는 추세이다. HEVC는 가장 최신의 비디오 부호화 표준으로 다양한 부호화 툴을 이용하여 높은 부호화 효율을 제공하지만 복잡도 또한 이전 부호화 표준과 비교하여 매우 높다. 특히 초고해상도 영상을 HEVC 복호기로 실시간 복호화 하는 것은 매우 높은 복잡도를 요구한다. 따라서 본 논문에서는 고해상도 및 초고해상도 영상에 대한 HEVC 복호기의 복호화 속도를 개선시키고자 HEVC에서 지원하는 슬라이스(Slice)와 타일(Tile) 부호화 툴을 사용하여 각 슬라이스 혹은 타일을 동시에 처리하며 디블록킹 필터 과정에서도 소정의 블록 크기만큼 동시에 처리하는 데이터-레벨 병렬 처리 방법을 소개한다. 이는 독립 복호화가 가능한 타일, 슬라이스, 혹은 디블록킹 필터에서 동일 연산을 다중 스레드에 분배하는 방법으로 복호화 속도를 향상 시킬 수 있다. 실험에서 제안 방법이 HEVC 참조 소프트웨어 대비 4K 영상에 대해 최대 2.0배의 복호화 속도 개선을 얻을 수 있음을 보인다.

고집적 송수신기를 위한 밀리미터파 LTCC Front-end 모듈 (Millimeter-wave LTCC Front-end Module for Highly Integrated Transceiver)

  • 김봉수;변우진;김광선;은기찬;송명선
    • 한국전자파학회논문지
    • /
    • 제17권10호
    • /
    • pp.967-975
    • /
    • 2006
  • 본 논문에서는 40 GHz 대역에서 동작하는 IEEE 802.16 고정 무선 통신을 위한 천이, 소형 TDD 송수신 모듈의 front-end 모듈을 설계하고 구현하는 방법을 제안한다. 제안된 모듈은 저손실과 소형화를 동시에 달성하기 위하여 캐비티 공정을 가지는 다층 LTCC 기술을 이용하여 제작되었다. 스위치의 입출력단에 와이어본드 정합회로의 설계 및 안테나와의 연결을 위한 도파관 천이 구조를 통해 저손실의 천이를 얻었으며, 기존 금속 도파관 필터를 대체한 유전체 도파관 필터를 사용함으로써 소형화를 달성하였다. 이를 구현하기 위해 유전율 7.1, 두께 100 um인 총 6층의 LTCC 기판을 사용하였으며 제작된 소형 front-end 모듈의 크기는 $30{\times}7{\times}0.8mm^3$이다. 그리고 송수신 삽입 손실 < 5.3 dB, 이미지 신호 제거 > 49 dB의 우수한 천이를 얻을 수 있었다.