• Title/Summary/Keyword: Image measurement

Search Result 3,152, Processing Time 0.033 seconds

A Study on the Image Processing Technique for Measurement of Nugget Geometry (용융부 형상 판독을 위한 영상처리기법)

  • 김상필;신현옥;최덕준;장희석
    • Proceedings of the KWS Conference
    • /
    • 1993.05a
    • /
    • pp.132-134
    • /
    • 1993
  • The conventional way of molten nugget size measurement in welding process have utilized the metal-microscope by examining the micro sectioned weld specimen after micro-etching procedure. This paper proposes a new method for exact measurement of molten nugget size with the aid of the digital image processing unit and some developed software. This method proved to be convenient and precise in that resulting resolution and accuracy are as good as that of the conventional method.

  • PDF

Fabrication of the focal length and distortion measurement system (초점길이 및 왜곡수차 측정장치 제작)

  • 조현모
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.82-86
    • /
    • 1990
  • A camera type optical bench system equipped with a lens collimator and an image analyzer is fabricated to measure the equivalent focal length and distortion of lenses. This system is automatized by the computer which controls stepping motors. A nodal slide optical bench system equipped with an off axis reflective collimator is fabricated and improved by using rotating arms and air bearing system. distortion measurement on a wide angle lens using the camera method and the nodal slide method is reported. Defocusing error in the distortion measurement with the nodal slide optical bench is analyzed and improved by iteration method to search the correct image point.

  • PDF

Depth estimation by using a double conic projection (이중원뿔 투영을 이용한 거리의 추정)

  • 김완수;조형석;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1411-1414
    • /
    • 1997
  • It is essential to obtain a distane informaion in order to completely execute assembly tasks such as a grasping and an insertion. In this paper, we propose a method estimating a measurement distance from a sensor to an object through using the omni-directional image sensing system for assembly(OISSA) and show its features and feasibility by a computer simulation. The method, utilizing a forwarded motion stereo technique, is simple to search the corresponding points and possible to immediatiely obtain a three-dimensional 2.pi.-shape information.

  • PDF

Measurement of Porosity by EPMA-EDS Image Processing

  • Hung, Minhui;Li, Xiangting;Xia, Jiyu;Ding, Chuanxian
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.66-69
    • /
    • 1997
  • Porosity is one important characteristic feature and structural index of sprayed coatings. A method of measurement of porosity, EPMA-EDS image processing is developed in the paper. The characteristics of pores can be determined by processing of the image obtained from an electron microscope via VISTA, Not only the porosity can be presented but also the statistical result of pore size distribution. Finally it can be drawn from this paper that EPMA-EDS is a quite effective method to completely characterize the pores in plasma sprayed coatings.

  • PDF

Bridge Displacement Measurement System Using Image Processing (영상처리를 이용한 비접촉식 교량변위 측정 시스템)

  • Lee, Jong-Wun;Oh, Ju-Sung;Kwon, Soon-Deuk;Kwok, Jong-Won
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.284-296
    • /
    • 2005
  • Bridge displacement measurement system using image processing is developed to overcome the contact type system inefficiencies such as heavy, expensive property and temporary construction necessity. The system is composed of tablet PC with IEEE1394 digital camera, telescope lens and a designed target mark. The key is projection algorithm where all pixels are added up for each row(column) to find out the center line. The experimental results are shown compared with a contact type system.

  • PDF

High Speed Image Processing Algorithm for Structure Displacement Measurement (영상처리를 이용한 구조물 변위측정을 위한 고속 알고리즘)

  • Oh, Joo-Sung;Lee, Jong-Woon
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.835-836
    • /
    • 2006
  • For non-contact structure vibration displacement measurement system, an algorithm for image processing using high speed CCD camera is introduced. The system sets the target to the structure, take picture using camera and image processing is performed to display the vibration data. The algorithm flow is basic preprocessing, projection data generation and curve fitting to find three crossing points for calibration or one center point in limited area.

  • PDF

Angle Measurement of MEMS Devices Image Processing (Image Processing에 의한 MEMS소자의 미세한 각도측정)

  • Ko, Jin-Hwan;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2198-2200
    • /
    • 2000
  • This paper reports on the measurement of angle between micro mirror and substrate in. the Micro Optical Cross Connect(MOXC). MOXC consists of beam collimators and $N{\times}N$ micro mirrors that are fabricated by using MEMS technology. Using subpixel level image processing, it is possible to measure the angle with the resolution of 0.27$^{\circ}$.

  • PDF

A Study on Bubbly Flow using PIV Measurement (PIV 법을 이용한 기포유동에 관한 연구)

  • 배대석;권오봉
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.898-903
    • /
    • 2001
  • The particle image velocimetry with liquid crystal tracers is used for visualizing and analysis of the bubbly flow in a vertical temperature gradient. This method allows simultaneous measurement of velocity and temperature field at a given instant of time Quantitative data of velocity were obtained by applying the MQD technique to visualized image. The paper describes the method, and presents the transient velocity patterns of bubbly flow.

  • PDF

Research on a Method for the Optical Measurement of the Rifling Angle of Artillery Based on Angle Error Correction

  • Zhang, Ye;Zheng, Yang
    • Current Optics and Photonics
    • /
    • v.4 no.6
    • /
    • pp.500-508
    • /
    • 2020
  • The rifling angle of artillery is an important parameter, and its determination plays a key role in the stability, hit rate, accuracy and service life of artillery. In this study, we propose an optical measurement method for the rifling angle based on angle error correction. The method is based on the principle of geometrical optics imaging, where the rifling on the inner wall of the artillery barrel is imaged on a CCD camera target surface by an optical system. When the measurement system moves in the barrel, the rifling image rotates accordingly. According to the relationship between the rotation angle of the rifling image and the travel distance of the measurement system, different types of rifling equations are established. Solving equations of the rifling angle are deduced according to the definition of the rifling angle. Furthermore, we added an angle error correction function to the method that is based on the theory of dynamic optics. This function can measure and correct the angle error caused by the posture change of the measurement system. Thus, the rifling angle measurement accuracy is effectively improved. Finally, we simulated and analyzed the influence of parameter changes of the measurement system on rifling angle measurement accuracy. The simulation results show that the rifling angle measurement method has high measurement accuracy, and the method can be applied to different types of rifling angle measurements. The method provides the theoretical basis for the development of a high-precision rifling measurement system in the future.

A Study of Osteoporosis Prediction using Morphological Measuring of Proximal Femoral Part and Trabecular Characteristics Based on Femoral Radiographic Image (대퇴부 방사선영상에서 대퇴골 근위부의 형태학적 측정과 골소주의 특성을 이용한 골다공증 예측에 관한 연구)

  • Kim, Sung-Min;Roh, Seung-Gyu;Ro, Yong-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.823-830
    • /
    • 2010
  • This study was designed to examine the morphological measurement and characteristics of trabecullae based on femoral radiographic image for prediction of osteoporosis. Study subjects were 34 females (average age of 62.1 years) and 6 males (average age of 60.1 years), they were categorized into normal group and osteoporosis group in accordance with the T-score value. Measurement of the bone density of femoral bone was measured with DEXA(Dual Energy X-ray absorptiometry). ROI(Region of interests) was selected on femoral neck and trochanter. Characteristics of trabecullae was analyzed by using the skeletonization analysis of trabecular image. Morphological measurement was analyzed through femoral radiographic image in order to examine the correlation with osteoporosis. The result demonstrated statistically significant correlation between neck cortical thickness, shaft width, shaft cortical thickness, periphery, mean gray level and trabeculae area with BMD average (T-score) of femoral part. The results show that morphological measurement and characteristics of trabecullae based on femoral radiographic images for osteoporosis prediction could be effective.