• Title/Summary/Keyword: Image comparison

Search Result 2,409, Processing Time 0.027 seconds

, the Cinema of Attractions (<디 워>, 매혹의 영화)

  • Ryu, Jae Hyung
    • Cartoon and Animation Studies
    • /
    • s.29
    • /
    • pp.209-241
    • /
    • 2012
  • Is a failed blockbuster film? Is there no room for reconsideration of the value of the film in terms of its contents and forms? The purpose of this study is to answer these questions. In 2007, SHIM Hyung-rae's was in the limelight due to the nationalist discourse around the film rather than evaluation of the film itself. In terms of its narrative and formal properties, the film showed the difference from the Korean nationalist blockbuster films. It led to the disaccord and hard-to-understand results of having somewhat disappointed box-office success of 8,500,000 audiences in comparison to the input, of receiving well by a generous part of the audiences absorbed by nationalism, and of getting the critics' cynic criticism of the film's cinematic value. Eventually only provided the cultural battlefield of nationalism, was left as an unnoticed film in the realm of industry and criticism. However, it was interesting that there was a common ground between the film's supporters and the cynic critics. Both sides were being acknowledged that the spectacle of was way out of proportion to the degree that the spectacle was unbalanced with the story unfolding, achieved more than expected. Its spectacle overwhelming the narrative enfever a few audiences, and at the same time, it provided some reasons making critics face away from the film. In this context, the purpose of this study is to examine 's aesthetics that 'the spectacle dominating narrative' or 'the narrative as a pretext for showing spectacle,' leading to discussion of artistic/theoretical/critical value and to find out cinematic value of the film being regarded as a failure. In addition, this study is significant in that it suggests that is a new kind of moving image that it cannot be analyzed with existed critical methods of narrative film criticism; as a result, this study provides the chance to be evaluated through a new conceptual frame of the film. In order to grasp the narratological aesthetics, this study focuses on the concept of trickality that Andre Gaudreault suggests, and Tom Gunning's 'the cinema of attractions,' referring to the spectacle-oriented narrativity or the mode of production displaying the spectacle more than the narrative.

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

Anxiety and Depression of The Korean Residents in China (중국 거주 조선인의 불안과 우울에 관한 실태)

  • SaKong, Jeong-Kyu;Cheung, Seung-Douk;Kim, Chang-Su;Kim, Cheol-Gu;Kim, Bong-Jin
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.2
    • /
    • pp.275-287
    • /
    • 1992
  • In order to survey the reality of anxiety and depression among the Koreans residing in China, a study was conducted between January and March of 1991, on the residents of Yun-Kil city, with subjects of 472 Koreans and 479 Chinese. The evaluation was based on the questionairs, named Combined self-rating anxiety depression scale(CADS), distributed among the subjects. ANOVA and t-test were applied for data processing. The results were as follows : There was not significant difference in the mean of total scores between the two groups. The scores of Koreans were $29.70{\pm}7.03$, while those of Chinese were $29.45{\pm}9.01$. The score of the CADS above 50(clinially significant level) was seen in 12(2.54%) Koreans and 21(4.38%) Chinese. The anxiety-depression scores relating to the items of indigestion and decreased appetite, sleep disturbance, apprehension, decreased libido were relatively high among the Koreans. The items appeared low in scores among the Koreans were faintness, fear, suicidal rumination, hopelessness, paresthesias. The highs among the Chinese were facial flushing, anxiousness, dissatisfaction, suicidal rumination. The items appeared low among the Chinese were fear, faintness, paresthesias, weight loss, suicidal rumination. In the comparison of evaluation by items between the two groups, the items placing the Koreans significantly higher over the Chinese are indigestion & decreased appetite, sleep disturbance, apprehension, decreased libido. The Chinese marked significantly higher in facial flushing, anxiousness, dissatisfaction, suicidal rumination. Those in the case of female (p<0.01 respectively), less than twenty years old (p<0.01 respectively), dissatisfied with family relationship(p<0.01 respectively), with past history of psychiatric hospitalization(Koreans p<0.01, Chinese p<0.05), pessimistic toward future, present, past self image(p<0.01 respectively) had significantly higher scores in both groups. In religion, neither group showed significant difference. In religion, neither group showed significant difference. In marital status, the Koreans showed a higher degree of divorce and separation and the Chinese in singleness(p<0.01 respectively). The Korean were higher in illiteracy and the Chinese had more college education(p<0.01 respectively). In place of growth, the Koreans showed not much difference in the areas while more Chinese grew up un large cities(p<0.01). More Koreans lived in the dormitory while the Chinese were engaged more in self-cooking(p<0.01 respectively). In pocket money per mouth, more Koreans were less than 1 dollar while the Chinese were between 7 and 10 dollars(p<0.01 respectively). There were no significant difference between two groups about religion.

  • PDF

Comparison of the Results of Ultrasound-guided Caudal Epidural Block - Herniated Intervertebral Disc vs Spinal Stenosis - (초음파를 이용한 미추 경막외 차단술의 결과 비교 - 추간판 탈출증과 척추관 협착증 -)

  • Kim, Young-Tae;Cho, Kyu-Jung;Ahn, Chi-Hoon
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.105-112
    • /
    • 2014
  • Purpose: Ultrasound-guided epidural caudal block for low back pain and radiating pain is often performed in the treatment of outpatients. However, this procedure has a failure rate of up to 25% even when it performed by an experienced physician. The authors investigate the effectiveness of Ultrasound-guided epidural caudal block in patients related to disc herniation or spinal stenosis. Materials and Methods: Ultrasound-guided caudal epidural block was performed in 55 outpatients with LBP and radiating pain. Patient was placed in the prone position and sonographic image of sacral hiatus was obtained using linear probe. A 22-gauge needle was advanced into the sacrococcygeal membrane under ultrasound guidance and then medication was injected into the caudal epidural space. There were 31 cases of disc herniation, and 24 cases of spinal stenosis. Patients were evaluated by Visual Analog Scale (VAS) pain score at pre-treatment, post-treatment, 2 weeks and 4 weeks by telephone interviews. Results: 53 of the 55 cases (96.4%) of needle insertion into the sacral canal under ultrasound guidance were successful. Gender was not significantly different between disc herniation group and spinal stenosis group. But there was a significant age difference between disc herniation group ($42.3{\pm}10.8$), and spinal stenosis group ($62.8{\pm}15.1$) [p<0.001]. The VAS score at pre-treatment, post-treatment, 2 weeks, 4 weeks in disc group were 6.84, 3.1, 1.8 & 1.77. The VAS score at pre-treatment, post-treatment, 2 weeks, 4 weeks in spinal stenosis group were 6.88, 3.58, 4.33 & 4.88. The VAS score in both groups was significantly improved after the procedure (p<0.001). Over time, the two groups were statistically significant differences in VAS score after adjusting for age (p<0.001). Conclusion: Ultrasound-guided caudal epidural block seems to provide a high success rate and a significantly better response in disc group than spinal stenosis group.

  • PDF

Comparison of Life Style, School Achievement and Snaking Behaviors among Underweight and Overweight Adolescents (일부 저체중과 과체중 청소년의 생활습관, 학업성취도 및 간식섭취행동의 비교)

  • Kim, Hye-Kyung;Kim, Jin-Hee
    • Journal of Nutrition and Health
    • /
    • v.44 no.2
    • /
    • pp.131-139
    • /
    • 2011
  • The purpose of this study was to obtain information related to life style characteristics, school achievement and snacking behaviors among underweight and overweight adolescents in Ulsan area. The survey was carried out by self-questionnaires with 464 adolescents (333 underweight and 131 overweight). The results were as follows: Average BMI of the subjects was $19.81{\pm}3.10\;kg/m^2$ which was normal range, but average BMI of underweight and overweight were $16.90{\pm}1.19\;kg/m^2$ and $25.38{\pm}2.16\;kg/m^2$ respectively. The 49.5% of underweight and 94.7% of overweight students have correct perception about their body image. In the sleeping time, 58.9% of underweight and 66.4% of overweight students go to bed after PM 12 o'clock. In the regularity of eating breakfast, 68.5% of underweight and 67.9% of overweight students skipping breakfast at least 5 times per week. 32.6% of the subjects had snack once or more a day. Underweight students had more frequently ate snack than overweight students. The criteria of choosing snack were taste (77.4%), nutrition (9.3%), and price (6.3%). Food as snack they frequently had fruits, milk & milk products, cookies in order. Underweight students had more dodkboki & sundae, candy & chocolate and cake & bread than overweight students, although overweight students had more milk & yogurt than underweight students. The group who had a higher school record, they significantly had more fruits, milk & milk products (p < 0.01) and had not less nutritious foods (p < 0.001). This study may provide basic information on weight status, sleeping and snacking behaviors of adolescents. Therefore they should have nutrition education program to improve their life style and snacking patterns for underweight and overweight adolescents toward healthy weight.

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

ALL-SKY OBSERVATION OF THE 2001 LEONID METEOR STORM: 1. METEOR MAGNITUDE DISTRIBUTION (전천 카메라를 이용한 2001 사자자리 유성우 관측: 1. 유성 등급 분포)

  • 김정한;정종균;김용하;원영인;천무영;임홍서
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.4
    • /
    • pp.283-298
    • /
    • 2003
  • The 2001 Leonid meteor storm has been observed all over the world, and its most intense flux since the last few decades has caused great interest among both laymen and experts. Especially, its maximum hours occurred at dawn hours of Nov. 19 in the east Asia, during which moonless clear night at the Mt. Bohyun allowed us near perfect condition of observation. Observation was carried out in the period of 01:00∼05:40(KST), which include the predicted maximum hours, with all-sky camera installed for upper atmospheric airglow research. Tn this paper we analyze 68 all-sky images obtained in this period, which contain records of 172 meteors. Utilizing the zenith hourly rate(ZHR) of 3000 and magnitude distribution index of 2, which were reported to International Meteor Organization by visible observers in the east Asia, we estimate the limiting magnitude of about 3 for meteors detected in our all-sky images. We then derive magnitudes of 83 meteors with clear pixel brightness outlines among the initially detected 172 meteors by comparing with neighbor standard stars. Angular velocities of meteors needed for computing their passing times over an all-sky image are expressed with a simple formula of an angle between a meteor head and the Leonid radiant point. The derived magnitudes of 83 meteors are in the range of -6∼-1 magnitude, and its distribution shows a maximum new -3mag. The derived magnitudes are much smaller than the limiting magnitude inferred from the comparison with the result of naked-eye observations. The difference may be due to the characteristic difference between nearly instantaneuous naked-eye observations and CCD observations with a long exposure. We redetermine magnitudes of the meteors by adjusting a meteor lasting time to be consistent with the naked-eye observations. The relative distribution of the redetermined magnitudes, which has a maximum at 0 mag., resembles that of the magnitudes determined with the in-principle method. The relative distribution is quite different from ones that decrease monotonically with decreasing magnitudes for meteors(1∼6) sensitive to naked-eye observations. We conclude from the magnitude distribution of our all-sky observation that meteors brighter than about 0 mag., appeared more frequently during the 2001 Leonid maximum hours. The frequent appearance of bright meteors has significantly important implication for meteor research. We noted, however, considerably large uncertainties in magnitudes determined only by comparing standard stars due to the unknown lasting time of meteors and the non-linear sensitivity of all-sky camera.

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

The comparison of landmark identification errors and reproducibility between conventional lateral cephalometric radiography and digital lateral cephalometric radiography (일반두부방사선계측사진과 디지털방사선계측사진의 계측점 식별의 오차 및 재현성에 관한 비교 연구)

  • Lee, Yang-Ku;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.79-89
    • /
    • 2002
  • The purpose of this study is to evaluate the reproducibility and errors in landmark identification of conventional lateral cephalometric radiography and digital lateral cephalometric radiography. Fifteen conventional lateral cephalometric radiographs and fifteen digital lateral cephalometric radiographs were selected in adults with no considerations on sex and craniofacial forms. Each landmark was identified and expressed as the coordinate (x, y). The landmarks were classified into 3 groups. The landmarks of the first identification was T1, identification after one week was T2, and identification after one month was T3. The mean and standard deviation of identification errors between replicates were calculated according to the x and y coordinates. The errors between first identification and second identification were expressed as T2-T1(x), T2-T1(y) and those between first identification and third identification were expressed as T3-T1(x), T2-T1(y). Each was divided into conventional lateral cephalometric radiography and digital lateral cephalometric radiography. The independent t- test was used for statistical analysis of identification errors for the evaluation of reproducibility. The results of this study were as follows ; 1. Generally, the mean and standard deviation of landmark identification errors in digital lateral cephalometric radiography was smaller than those of conventional lateral cephalometric radiography. 2. Only a few landmarks showed statistically significant difference in identification error between conventional lateral cephalometric radiography and digital lateral cephalometric radiography. 3. The enhancement of image quality didn't guarantee decrease in landmark identification error and didn't affect tendency of landmark identification error.

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF