• Title/Summary/Keyword: Image chip

Search Result 357, Processing Time 0.03 seconds

Implementation of Visual Data Compressor for Vision Sensor of Mobile Robot (이동로봇의 시각센서를 위한 동영상 압축기 구현)

  • Kim Hyung O;Cho Kyoung Su;Baek Moon Yeal;Kee Chang Doo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.9 s.174
    • /
    • pp.99-106
    • /
    • 2005
  • In recent years, vision sensors are widely used to mobile robot for navigation or exploration. The analog signal transmission of visual data being used in this area, however, has some disadvantages including noise weakness in view of the data storage. A large amount of data also makes it difficult to use this method for a mobile robot. In this paper, a digital data compressing technology based on MPEG4 which substitutes for analog technology is proposed to overcome the disadvantages by using DWT(Discreate Wavelet Transform) instead of DCT(Discreate Cosine Transform). The TI Company's DSP chip, TMS320C6711, is used for the image encoder, and the performance of the proposed method is evaluated by PSNR(Peake Signal to Noise Rates), QP(Quantization Parameter) and bitrate.

Measurement of the Surface Emissivity of the LED Lighting Module (LED 조명 모듈 표면의 방사율 측정에 관한 연구)

  • Park, Jin-Sung;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.493-501
    • /
    • 2013
  • LED lighting is sensitive because it made by semiconductor. So it has been researched about radiation of heat technologies for a long time. In addition, measurement and assessment a radiation of heat also conducted. It is necessary to get a date of accuracy temperature on the board after LED driven for measuring Junction temperature of the LED Lighting. For this research, we use 5 chip which is 4 W power on top of LED lighting board made by aluminum. Thermal camera effects to emissivity depending on material and property of the surface in LED board because it determines thermal energy which emitted from material surface. it is not only thermal camera has not a standard about emissivity. It has an error of temperature when emissivity was measured by thermal camera. we confirmed that emissivity and reflected temperature depending on color and quality of the surface throughout experiment.

2.2" Digital driving AMOLED One-chip Solution for Mobile Application

  • Bae, Han-Jin;Kim, Seung-Tae;Lim, Ho-Min;Ha, Won-Kyu;Lee, Jae-Do;Kim, Ji-Hun;Kim, Hak-Su;Han, Chang-Wook;Tak, Yoon-Heung;Ahn, Byung-Chul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.127-130
    • /
    • 2008
  • A 2.2" QVGA($320{\times}240$) 262,114 color AMOLED module has been developed using digital driving methodology. In this paper, we discuss the development of diver IC which is applied to Digital AMOLED module. Technologies for low cost IC structure and image quality enhancement are presented.

  • PDF

A Study on Machine Vision System and Camera Modeling with Geometric Distortion (기하학적 왜곡을 고려한 카메라 모델링 및 머신비젼 시스템에 관한 연구)

  • 계중읍
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.4
    • /
    • pp.64-72
    • /
    • 1998
  • This paper a new approach to the design of machine vision technique with a camera modeling that accounts for major sources of geometric distortion, namely, radial, decentering, and thin prism distortion. Radial distortion causes an inward or outward displacement of a given image point from its ideal location. Actual optical systems are subject to various degrees of decentering , that is , the optical centers of lens design and manufacturing as well as camera assembly. It is our propose to develop the vision system for the pattern recognition and the automatic test of parts and to apply the line of manufacturing. The performance of proposed vision system is illustrated by simulation and experiment.

PIV measurements of a microfluidic elements fabricated in a plastic chip (플라스틱 미소유체요소 내부유동의 PIV 측정)

  • Lee, In-Won;Choi, Jay-Ho;Lee, In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.400-404
    • /
    • 2001
  • A micro-PIV(particle image velocimetry) measurement has been conducted to investigate flow fields in such microfluidic devices as microchannels and micronozzle. The present study employs a state-of-art micro-PIV system which consists of epi-fluorescence microscope, 620nm diameter fluorescent seed particles and an 8-bit megapixel CCD camera. Velocity vector fields with a resolution of $6.7\times6.7{\mu}m$ has been obtained, and the attention has been paid on the effect of varying measurement conditions of particle diameter and particle concentration on the resulting PIV results. In this study, the microfluidic elements were fabricated on plastic chips by means of MEMS processes and a subsequent molding process. Flow fields in a variety of microchannels as well as micronozzle have been investigated.

  • PDF

A Memory Intensive Real-time 3x3 Neighborhood processor for Image Processing (Memory Intensive 실시간 영상신호처리용 3 $\times$ 3 Neighborhood VLSI 처리기)

  • 김진홍;남철우;우성일;김용태
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.6
    • /
    • pp.963-971
    • /
    • 1990
  • This paper proposes a memory intensive VLSI architecture for the realization of real-time 3x3 neighborhood processor based on the distributed arithmetic. The proposed architecture is characterized by a bit serial and multi-kernel parallel processing which exploits the pixel kernel parallelism and concurrency. The chip implements 8 neighborhood processing elements in parallel with efficirnt input and output modules which operate concurrently. Besides the a4chitectural design of a neighborhood processor, the design methodology using module generator concept has been considered and MOGOT(MOdule Generator Oriented VLSI design Tool) has been constructed based on the workstation. Based on these design environments MOGOT, it has been shown that the main part of the suggested architecture can be designed efficiently using 2\ulcorner double metal CMOS technology. It includes design of input delay and data conversion module, look-up table for inner product operation, carry save accumulator, output data converter and delay module, and control module.

  • PDF

Implementation of Mobile WiMAX Receiver using Mobile Computing Platform for SDR System (모바일 컴퓨팅 플랫폼을 이용한 SDR 기반 MOBILE WIMAX 수신기 구현)

  • Kim, Han Taek;Ahn, Chi Young;Kim, June;Choi, Seung Won
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.1
    • /
    • pp.117-123
    • /
    • 2012
  • This paper implements mobile Worldwide Interoperability for Microwave Access (WiMAX) receiver using Software Defined Radio (SDR) technology. SDR system is difficult to implement on the mobile handset because of restrictions that are computing power and under space constraints. The implemented receiver processes mobile WiMAX software modem on Open Multimedia Application Platform (OMAP) System on Chip (SoC) and Field Programmable Gate Array (FPGA). OMAP SoC is composed of ARM processor and Digital Signal Processor (DSP). ARM processor supports Single Instruction Multiple Data (SIMD) instruction which could operate on a vector of data with a single instruction and DSP is powerful image and video accelerators. For this reason, we suggest the possibility of SDR technology in the mobile handset. In order to verify the performance of the mobile WiMAX receiver, we measure the software modem runtime respectively. The experimental results show that the proposed receiver is able to do real-time signal processing.

A Study on the Selectivity of Gas Sensors by Sensing Pattern Recognition (감지 패턴 인식에 의한 가스센서의 선택성 연구)

  • Lee, Sung-Pil
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.428-433
    • /
    • 2011
  • We report on the building of a micro sensor array based on typical semiconductor fabrication processes aimed at monitoring selectively a specific gas in ambient of other gases. Chemical sensors can be applied for an electronic nose and/or robots using this technique. Microsensor array was fabricated on the same chip using 0.6${\mu}m$ CMOS technology, and unique gas sensing patterns were obtained by principal component analysis from the array. $SnO_2$/Pt sensor for CO gas showed a high selectivity to buthane gas and humidity. $SnO_2$ sensor for hydrogen gas, however, showed a low selectivity to CO and buthane gas. We can obtain more distinguishable patterns that provide the small sensing deviation(the high seletivity) toward a given analyte in the response space than in the chemical space through the specific parameterization of raw data for chemical image formation.

Bioinformatics for the Korean Functional Genomics Project

  • Kim, Sang-Soo
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2000.11a
    • /
    • pp.45-52
    • /
    • 2000
  • Genomic approach produces massive amount of data within a short time period, New high-throughput automatic sequencers can generate over a million nucleotide sequence information overnight. A typical DNA chip experiment produces tens of thousands expression information, not to mention the tens of megabyte image files, These data must be handled automatically by computer and stored in electronic database, Thus there is a need for systematic approach of data collection, processing, and analysis. DNA sequence information is translated into amino acid sequence and is analyzed for key motif related to its biological and/or biochemical function. Functional genomics will play a significant role in identifying novel drug targets and diagnostic markers for serious diseases. As an enabling technology for functional genomics, bioinformatics is in great need worldwide, In Korea, a new functional genomics project has been recently launched and it focuses on identi☞ing genes associated with cancers prevalent in Korea, namely gastric and hepatic cancers, This involves gene discovery by high throughput sequencing of cancer cDNA libraries, gene expression profiling by DNA microarray and proteomics, and SNP profiling in Korea patient population, Our bioinformatics team will support all these activities by collecting, processing and analyzing these data.

  • PDF

Development of Visual Inspection System for a CoG (CoG 시각 검사 시스템 개발)

  • Jeong Jong-Myeon;Kim Chi-Yeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.4
    • /
    • pp.667-673
    • /
    • 2006
  • In this paper, we present a visual inspection system for a CoG using statistical features. After rotational error of an input image is compensated using Hough transformation, an inspection area is obtained by using projection method. Then the final result is derived from statistical features of segmented pad areas.