• Title/Summary/Keyword: Image Viewer

Search Result 194, Processing Time 0.025 seconds

Comparative Study for the Measurement of Fermoral Anteversion by Manual Method and Image Viewer (대퇴골 전염각 측정을 위한 수 작업 방법과 Image Viewer 방법과의 비교 연구)

  • Gwon, Dae-Cheol;Park, Beom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.27-35
    • /
    • 2001
  • The measurement of the fermoral anteversion is an important factor in the practice of orthopedic surgery. The anteversion is measured by means of the axis of head and neck of the femur. In this study. widely used computed tomography method of measuring anteversion was tested on femoral necks of patients. Measurement by the manual method and image viewer of computed tomography to determine the anteversion of femoral head were carried out on both femurs. In January and February 2001, 30 patients 3 to 6 years of age were randomly selected from Seoul National University Hospital. the purpose of this paper was to introduce a new method to measure femoral anteversion angle utilizing image viewer program. This new method was more accurate and convenient than the conventional manual method. No significant difference was observed between the manual method and the image viewer measurement of femoral anteversion. In conclusion, image viewer program was statistically more reliable in determining the angle of the fermoral anteversion.

  • PDF

Construction of Medical Image Information Viewer-Matching System Based by Diseases (질환별 의료영상정보 뷰어 매칭 시스템의 구축)

  • No, Si-Hyung;Ham, Gyu-Sung;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.20 no.5
    • /
    • pp.37-47
    • /
    • 2019
  • The purpose of this paper is to construct a system that matches the patient's image disease information with the medical image viewer in providing the medical image information to the medical staff. Currently, medical image information systems that are commercialized mostly provide only one image viewer with various image information of diseases or use incompatible exclusive viewers. For this reason, we designed and implemented a medical image information viewer matching system that integrates and provides specialized viewers that can be selected by diseases' image information. That is, it is a system to match and view medical image viewers based on disease information extracted from tag information stored as the metadata in DICOM file, which is medical image information standard, for disease-specific viewer matching. We analyzed the execution performances through our retrieval service of medical image information from our implementation system, and showed compatibility and control with various viewers.

Development of Mobile DICOM Image Viewer for Decipher of Medical Images (의학 영상 판독을 위한 모바일 DICOM 영상 뷰어 개발)

  • Lee, Jung-Il;Park, Seung-Je;Won, Hul-Chul
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.3
    • /
    • pp.30-36
    • /
    • 2009
  • With the rapid progress of medical image information system, a variety of researches for the system that can read and decipher the medical images in anytime and anywhere have been studied. In this paper, we develop personal digital assistant (PDA) device based mobile digital imaging and communications in medicine (DICOM) image viewer that can process the received medical images at any time. In particular, with the aid of the proposed mobile DICOM image viewer, we can read several images simultaneously and we can read the selected image only from the several images. To cope with the small size of PDA screen, the function of image enlargement is also included in the proposed mobile DICOM image viewer.

Design of the Web based Mini-PACS (웹(Web)을 기반으로 한 Mini-PACS의 설계)

  • 안종철;신현진;안면환;박복환;김성규;안현수
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 2003
  • PACS mostly has been used in large scaled hospital due to expensive initial cost to set up the system. The network of PACS is independent of the others: network. The user's PC has to be connected physically to the network of PACS as well as the image viewer has to be installed. The web based mini-PACS can store, manage and search inexpensively a large quantity of radiologic image acquired in a hospital. The certificated user can search and diagnose the radiologic image using web browser anywhere Internet connected. The implemented Image viewer is a viewer to diagnose the radiologic image. Which support the DICOM standard and was implemented to use JAVA programming technology. The JAVA program language is cross-platform which makes easier upgrade the system than others. The image filter was added to the viewer so as to diagnose the radiologic image in detail. In order to access to the database, the user activates his web browser to specify the URL of the web based PACS. Thus, The invoked PERL script generates an HTML file, which displays a query form with two fields: Patient name and Patient ID. The user fills out the form and submits his request via the PERL script that enters the search into the relational database to determine the patient who is corresponding to the input criteria. The user selects a patient and obtains a display list of the patient's personal study and images.

  • PDF

A Study of Clinical Propriety from ECG Viewer Using Smart Phone (스마트폰을 이용한 ECG Viewer의 임상적 타당성 검토)

  • Kim, Jung-Su
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.1-4
    • /
    • 2010
  • The study was designed to transmit ECG(electrocardiogram) images from iPhone in order to check validity. Especially, web examined ECG transmissions from smart phones image viewer are good enough to secure clinical information and confirmed with visual. In result, it took 3 to 5 seconds for ECG viewer transmitting from a smart phone to display an image on mobile server to user's phone. For image valuation, we magnified the ECG image 100% or 200% at a resolution of $480{\times}320$ checking PQRST wave and found that it was both possible to see an accurate PQRST wave with all the trial data and to divide it into 1mm level of grid.

  • PDF

MR Imaging Measurement of the Femoral Anteversional Angle as a PACS Image Viewer (MR 영상에서의 PACS Image Viewer를 이용한 대퇴골 전염각 측정)

  • Kweon, Dae-Cheol;Yang, Sung-Hwan;Park, Peom
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.83-89
    • /
    • 2003
  • The accurate measurement of the femoral anteversion is very important to the practice of orthopedic and osteotomy. It is measured by means of the axis of head and neck of the femur and the knee axis. At the present time, widely used computed tomography method of measuring anteversion on femoral necks of patients. Measurement by the manual method and image viewer of computed tomography to determine the anteversion of femoral head were carried out on both femurs. In September and October 2002, 5 patients 28 to 36 years of age were randomly selected from Seoul National University Hospital. The purpose of this paper was to introduce a new method to measure femoral anteversion angle utilizing PACS image viewer program in the MR imaging. Significant difference was observed between the right and left side the image viewer measurement of femoral anteversion. In conclusion, MR imaging very usefulness in the measured the angle of the femoral anteversion.

  • PDF

Unattended fire detection system using a wireless communication device (무선통신 단말기를 이용한 무인화재 감지시스템)

  • Chang, Rak-Ju;Lee, Soon-Yi;Kang, Suk-Won
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.25-26
    • /
    • 2015
  • The Unattended fire detection system using a wireless communication device is designed in this paper. If a fire occurs in some area, the system can detect and automatically extinguish the fire. The major functions for the system are: Unattended detection system for fire based on wireless communication system and Automatic extinguish device system; Thermal imaging camera and video camera system; Monitoring viewer and map viewer system.

  • PDF

Stereoscopic Conversion of Monoscopic Video using Edge Direction Histogram

  • Kim, Jee-Hong;Kim, Dong-Wook;Yoo, Ji-Sang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.67-70
    • /
    • 2009
  • This paper proposes an algorithm for creating stereoscopic video from a monoscopic video. A viewer uses depth perception clues called a vanishing point which is the farthest from a viewer's viewpoint in order to perceive depth information from objects and surroundings thereof to the viewer. The viewer estimates the vanishing point with geometrical features in monoscopic images, and can perceive the depth information with the relationship between the position of the vanishing point and the viewer's viewpoint. In this paper, we propose a method to estimate a vanishing point with edge direction histogram in a general monoscopic image and to create a depth map depending on the position of the vanishing point. With the conversion method proposed through the experiment results, it is seen that stable stereoscopic conversion of a given monoscopic video is achieved.

  • PDF

The Position Tracking Algorithm of Moving Viewer's Two-Eyes (움직이는 관찰자의 두 눈 위치 검출 알고리즘)

  • Huh, Kyung-Moo;Park, Young-Bin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.7
    • /
    • pp.544-550
    • /
    • 2000
  • Among the several types of 3D display methods the autostereoscopic method has an advantage that we can enjoy a 3D image without any additional device but the method has a disadvantage of a narrow viewing zone so that the moving viewer coannot see the 3D image continuously. This disadvantage can be overcome with the detectioni of viewer's positional movement by head tracking. In this paper we suggest a method of detecting the position of the moving viewer's two eyes by using images obtained through a color CCD camera, The suggested method consists of the preprocessing process and the eye-detection process. Through the experiment of applying the suggested method we were able to find the accurate two-eyes position for 78 images among 80 sample input images of 8 different men with the processing speed of 0.39 second/frame using a personal computer.

  • PDF

The Design and Implementation of a Reusable Viewer Component

  • Kim, Hong-Gab;Lim, Young-Jae;Kim, Kyung-Ok
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.66-69
    • /
    • 2002
  • This article outlines the capabilities of a viewer component called GridViewer, and proves its reusability. GridViewer was designed for the construction of the image display part of GIS or remote sensing application software, and consequently it is particularly straightforward to closely couple GridViewer with access to very large images. Displaying is performed through pyramid structure, which enables to treat very large dataset up to several gigabytes in size under the limited capability of PC. GridViewer is free from responsibility to handle various formats of raster data files by taking grid coverage, which is designed by OGC to promote interoperability between implementations done by data vendors and software vendors providing analysis and grid processing implementations. GridViewer differs from other such viewer by allowing for clients to extend its function and capability by using small set of methods originally implemented in it. We show its reusability and expandability by applying it in developing application programs performing various functions not supported originally by the GridViewer COM component.

  • PDF