A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Stress/Rest Tc-99m-MIBI SPECT in Comparison with Rest/Stress Rubidium-82 PET (휴식/부하 심근 Rubidium-82 양전자단층촬영과 부하/휴식 심근 Tc-99m-MIBI 단일광자단층촬영의 비교)

  • Lee, D.S.;Kang, K.W.;Lee, K.H.;Jeong, J.M.;Kwark, C.;Chung, J.K.;Lee, M.C.;Seo, J.D.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.31-40
    • /
    • 1995
  • We compared stress/rest myocardial Tc-99m-MIBl tomographic image findings with rest/stress rubidium-82 tomographic images. In 23 patients with coronary artery disease (12 of them received bypass grafts before) and 6 normal subjects, rest rubidium PET study was performed : rubidium-82 and Tc-99m-MIBI were injected simultaneously to each patient after dipyridamole stress for rubidium PET and MIBI SPECT; and rest MIBI SPECT was performed 4 hours thereafter. We scored segmental decrease of rubidium or MIBI uptakes into 5 grades for 29 segments from 3 short-axis, vertical and horizontal slices. Scores were summed for each major arterial territory. When more score than two grade-2's or one grade-3 was considered as the cue for significant stenosis for major arterial territories, 67% of 46 stenosed arteries were found with MIBI studies and 78% of them by rubidium studies. Fourteen among 28 grafted arterial territories of 12 post-CABG patients were found normal with both rubidium and MIBI. Segmental scores were concordant between rubidium and MIBI in 72% of 709 stress segments and in 80% of 825 rest segments. Stress rubidium segmental scores were less than stress MIBI scores in 9%, so were rest rubidium scores. Stress rubidium scores were more than stress MIBI scores in 20% of segments, and rest rubidium segmental scores were more than rest MIBl scores in 11%. Rank correlations (Spearman's rho's more than 0.7(stress) and 0.5(rest), slopes (MIBI/rubidium) around 0.7(stress) and 0.9 (rest)) suggested deeper and wider defects in stress with rubidium. Slope over 1 (MIBI/rubidium) with LAD segemental scores at rest and 7 territories which had much larger score with MIBI revealed exaggeration of rest defects with rest MIBI in same-day stress/rest study. Difference scores (stress-rest for each territory) suggesting Ischemia were larger with rubidium (slope of MIBI/rubidium around 0.45). As has been implied by animal or separate-day-human studies, these segmental analyses with simultaneous examination in patients told that rubidium PET flow studies disclose ischemia more often than MIBI studies and that rest MIBI studies in same-day stress/rest-sequence gave a little larger rest defect than they would have shown.

  • PDF

Internal Changes and Countermeasure for Performance Improvement by Separation of Prescribing and Dispensing Practice in Health Center (의약분업(醫藥分業) 실시(實施)에 따른 보건소(保健所)의 내부변화(內部變化)와 업무개선방안(業務改善方案))

  • Jeong, Myeong-Sun;Kam, Sin;Kim, Tae-Woong
    • Journal of agricultural medicine and community health
    • /
    • v.26 no.1
    • /
    • pp.19-35
    • /
    • 2001
  • This study was conducted to investigate the internal changes and the countermeasure for performance improvement by Separation of Prescribing and Dispensing Practice (SPDP) in Health Center. Data were collected from two sources: Performance report before and after SPDP of 25 Health Centers in Kyongsangbuk-do and 6 Health Centers in Daegu-City and self-administerd questionnaire survey of 221 officials at health center. The results of this study were summarized as follows: Twenty-four health centers(77.4%) of 31 health centers took convenience measures for medical treatment of citizens and convenience measures were getting map of pharmacy, improvement of health center interior, introduction of order communication system in order. After the SPDP in health centers, 19.4% of health centers increased doctors and 25.8% decreased pharmacists. 58.1% of health centers showed that number of medical treatments were decreased. 96.4%, 80.6% 80.6% 96.7% of health centers showed that number of prescriptions, total medical treatment expenses, amounts paid by the insureds and the expenses to purchase drugs, respectively, were decreased. More than fifty percent(54.2%) of health centers responded that the relative importance of health works increased compared to medical treatments after the SPDP, and number of patients decreased compared to those in before the SPDP. And there was a drastic reduction in number of prescriptions, total medical treatment expenses, amounts paid by insureds, the expenses to purchase drugs after the SPDP. Above fifty percent(57.6%) of officers at health center responded that the function of medical treatment should be reduced after the SPDP. Fields requested improvement in health centers were 'development of heath works contents'(62.4%), 'rearrangement of health center personnel'(51.6%), 'priority setting for health works'(48.4%), 'restructuring the organization'(36.2%), 'quality impro­vement for medical services'(32.1%), 'replaning the budgets'(23.1%) in order. And to better the image of health centers, health center officers replied that 'health information management'(60.7%), 'public relations for health center'(15.8%), 'kindness of health center officers'(15.3%) were necessary in order. Health center officers suggested that 'vaccination program', 'health promotion', 'maternal and children health', 'communicable disease management', 'community health planning' were relatively important works, in order, performed by health center after SPDP. In the future, medical services in health centers should be cut down with a momentum of the SPDP so that health centers might reestablish their functions and roles as public health organizations, but quality of medical services must be improved. Also health centers should pay attention to residents for improving health through 'vaccination program', 'health promotion', 'mother-children health', 'acute and chronic communicable disease management', 'community health planning', 'oral health', 'chronic degenerative disease management', etc. And there should be a differentiation of relative importance between health promotion services and medical treatment services by character of areas(metropolitan, city, county).

  • PDF

Studies on the Directivity of Gokjungkyeong(Kyung Overlapped with Gok) which was specified in Byeokgye-ri, Yangpyeong-gun and the Hwaseo Lee, Hang-ro's Management in Byeokwon Garden (양평 벽계리에 설정된 곡중경(曲中景)의 지향성과 화서(華西) 이항로(李恒老)의 벽원(蘗園) 경영)

  • Jung, Woo-Jin;Rho, Jae-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.34 no.3
    • /
    • pp.78-97
    • /
    • 2016
  • The objectives of this study are to examine the context of the establishment of Suhoe Gugok, Byeokgye Gugok Vally, and Nosan Palkyung, which have been established in Seojong-myeon of Yangpyeong-gun, by literature review and site investigations, and to determine the sceneries of Byeokgye scenic site as enjoyed and managed during the period of Hwaseo Lee, Hang-ro(華西 李恒老). The results of the study are as follows. First, Byeokgye Gugok Vally(黃蘗九曲) and Nosan Palkyung(蘆山八景), which have been established after the period of Hwaseo and theorized to have been established around key scenic areas associated with Hwaseo's activities, the analysis results showed that they were collecting sceneries of modern times. The extensive overlap between Byeokgye Gugok Vally and concentrated scenic elements of Suhoe Gugok(水回九曲), and the artificial configuration from the end point of Suhoe Gugok to the beginning point of Nosan Palkyung, reveal the pattern of space conflict and hegemony between Byeokgyes of Suip-ri and Nomun-ri. This is likely to be caused by the conflict between the historicity of the group that enjoyed Byeokgye prior to Hwaso's period and the strong territoriality of the space filled with the image of Hwaseo. Second, Byeokgye Gugok Vally was the secondary spatial system created by selecting the most scenic sites in Suip-ri while expanding the area of Nosan Palkyung. After establishment of Byeokgye Gugok Vally, the spatial identity of the entire Byeokgyecheon area was effectively established. This was a "Hwaseo-oriented" move, including the complete exclusion of the scenic sites from the pre-Hwaseo period such as Cheongseo Gujang and Suhoe Gugok's Letters Carved on the Rock. Consequently, the entire Byeokgyecheon area was reorganized into a cultural scenic site with Heoseo's influence. Third, Fifth, creations of Gugok(九曲) to determine the lineage of the Hwaseo School from Juja(朱子) to Yulgok(栗谷) to Uam(尤庵) to Hwaseo is likely to be an opportunity of birth and external motivation of the establishment of new Gugok Palkyung. In other words, Nosan Palkyung and Byeokgye Gugok Vally are likely to have been created as a reaction to the change of the center of the Hwaseo School to Okgyedong, and with strategic orientation based on the motivation and needs such as creation of the connecting space between Mui Gugok, Gosan Gugok, and Okgye Gugok, and the elevation of Hwaseo's status. Fourth, from the Hwaseo's Li-centric point of view, all revered sites in Beokwon(蘗園) that he managed existed as the spatial creative work to experience the existence of "li" through the objects in the landscape and the boundary of the spirit of emptiness of the aesthetic self. This clearly shows how Byeokgye Gugok Vally or Nosan Palkyung must be defined, and furthermore, appreciated and approached, prior to discussing it as the space associated with Hwaseo. Fifth, Nosan Palkyung was composed of cultural scenic landscapes of Gokjungkyung(曲中景) with eight scenic sites where Hwaseo gave his teachings and spend time around, in the Byeokgye of Nomun-ri area of Byeokgye Gugok Vally. The sceneries is, however, collected by depending on Hwaseo's Letters Carved on the Rock and poetry. Consequently, an inner exuberance of Nosan Palkyung is satisfied beside Byeokgye Gugok Vally, but its conceptual adequacy leaves room for questions.

Evaluation of the Modified Hybrid-VMAT for multiple bone metastatic cancer (다중표적 뼈 전이암의 하이브리드 세기변조(modified hybrid-VMAT) 방사선치료계획 유용성 평가)

  • Jung, Il Hun;Cho, Yoon Jin;Chang, Won Suk;Kim, Sei Joon;Ha, Jin Sook;Jeon, Mi Jin;Jung, In Ho;Kim, Jong Dea;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.161-167
    • /
    • 2018
  • Purpose : This study evaluates the usefulness of the Modified Hybrid-VMAT scheme with consideration of background radiation when establishing a treatment plan for multiple bone metastatic cancer including multiple tumors on the same axis. Materials and Methods : The subjects of this study consisted of five patients with multiple bone metastatic cancer on the same axis. The planning target volume(PTV) prescription dose was 30 Gy, and the treatment plan was established using Ray Station(Ray station, 5.0.2.35, Sweden). In the treatment plan for each patient, two or more tumors were set as one isocenter. A volumetric modulated arc therapy(VMAT) plan, a hybrid VMAT(h) plan with no consideration of background radiation, and a modified hybrid VMAT(mh) with consideration of background radiation were established. Then, using each dose volume histogram(DVH), the PTV maximum dose($D_{max}$), mean dose($D_{mean}$), conformity index(CI), and homogeneity index(HI) were compared among the plans. In addition, the organ at risk(OAR) of each treatment site was evaluated, and the total MU(Monitor Unit) and treatment time were also analyzed. Results : The PTV $D_{max}$ values of VMAT, VMAT(h) and VMAT(mh) were 3188.33 cGy, 3526 cGy, and 3285.67 cGy, the $D_{mean}$ values were 3081 cGy, 3252 cGy, and 3094 cGy; the CI values were $1.35{\pm}0.19$, $1.43{\pm}0.12$, and $1.30{\pm}0.06$; the HI values were $1.06{\pm}0.01$, $1.14{\pm}0.06$, and $1.09{\pm}0.02$; and the VMAT(h) OAR value was increased 3 %, and VMAT(mh) OAR value was decreased 18 %, respectively. Furthermore, the mean MU values were 904.90, 911.73, and 1202.13, and the mean beam on times were $128.67{\pm}10.97$, $167.33{\pm}7.57$, and $190.33{\pm}4.51$ respectively. Conclusions : Applying Modified Hybrid-VMAT when treating multiple targets can prevent overdose by correcting the overlapping of doses. Furthermore, it is possible to establish a treatment plan that can protect surrounding normal organs more effectively while satisfying the inclusion of PTV dose. Long-term follow-up of many patients is necessary to confirm the clinical efficacy of Modified Hybrid-VMAT.

  • PDF

A Study on the Basic Planning of the Nam-Hae Sin-Sa Architecture (남해신사 기본계획에 따른 신당건축 고찰)

  • Kim, Sang Tae;Jang, Hun Duc
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.2
    • /
    • pp.62-85
    • /
    • 2009
  • The Nam-Hae Sin-sa, the South Sea shrine in Yeong-Am, Korea was a national institution for public peace and bliss, was excavated in 2000, and the shrine and the 3-way-gate were reconstructed in 2001. Hae Sin-sa, the Sea shrine is a place for religious service separated into the Nam-Hae Sin-sa, the Dong-Hae Myo, and the Seo-Hae Dan. The Dong-Hae Myo was reconstructed, but restored shrine and 3-way-gate of the Nam-Hae Sin-sa is not perfect in comparison with excavation plan in 2000, therefore new reconstruction was researched through the related literature, the analysis of historical maps and excavation results, the interview with the concerned people and the case study. This research defines the analysis of the Plan of the Nam-Hae Sin-sa Reconstruction as follows. 1. The Nam-Hae Sin-sa was the institution for religious service operated by national direct management, represents the shrine for public peace and bliss on the Mountain, the Sea, and the River. Especially the Nam-Hae Sin-sa had an important position on the pivot of international trade with China and Japan, and had a role of main shrine with another one in the Mt. Ji-ri San. 2. The name of the Sea shrine was called as Nam-Hae Sin-sa(the South Sea shrine), Dong-Hae Myo(the East Sea shrine), Seo-Hae Dan(the West Sea shrine). But the name of the South Sea shrine had changed in the early period of Chosun as Nam-Hae Sin-sa to the later Chosun as Nam-Hae Dang through the research of related literature and historical map. Such as the Seo-Hae Dan, it was constructed for the Dan, the flat raised-floor without buildings, and changed to the type of Sa-Dang with addition of buildings. 3. The historical map of Hae Sin-sa informs the types of the roof, the Mat-bae roof was used in the Dong-Hae Myo, but the Pal-jak roof was showed in the Seo-Hae Dan and the Nam-Hae Sin-sa. 4. According to the analysis of Yong-Ch'uck the unit length, Nam-Hae Sin-sa was reconstructed in the period of Koryo on large scale, but it was restored in the Chosun on middle scale. And the Unit of Yong Ch'uck was changed into Yeong-jo Ch'uck in the period of Chosun. 5. As the results, The Plan of the Nam-Hae Sin-sa Reconstruction designed the new shrine into the 3 Kan front and the 2 Kan side with 3:2 scale. An-ch'o-gong with Yong-du and Yong Mi the ornaments represents head and tail of dragon, the Un-gong and the ornament of Pa-ryun-dae-gong in the building, and the Ch'ung-ryang of the Yong-du show the image of the institution for religious service for the god of the sea who look like dragon. The inner gate building and the main entrance were designed as same plan and scale as Hyang-gyo, the Korean Traditional School and Shrine of Confucianism, on the basis of results of excavation. Raise the 3-tall gate of the main entrance with harmony of the scale and the shape, because the side of gate building has the Mat-bae roof. 6. This research shows that Plan of the Nam-Hae Sin-sa Reconstruction is composed into shrine space and reservation space from the main entrance to inner gate and shrine like Jung-ak Dan in the Mt. Gye-ryong San, and it also informs the well in the west side of Sin-sa is an important factor of the plan of shrine architecture.

A Methodology of Customer Churn Prediction based on Two-Dimensional Loyalty Segmentation (이차원 고객충성도 세그먼트 기반의 고객이탈예측 방법론)

  • Kim, Hyung Su;Hong, Seung Woo
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.4
    • /
    • pp.111-126
    • /
    • 2020
  • Most industries have recently become aware of the importance of customer lifetime value as they are exposed to a competitive environment. As a result, preventing customers from churn is becoming a more important business issue than securing new customers. This is because maintaining churn customers is far more economical than securing new customers, and in fact, the acquisition cost of new customers is known to be five to six times higher than the maintenance cost of churn customers. Also, Companies that effectively prevent customer churn and improve customer retention rates are known to have a positive effect on not only increasing the company's profitability but also improving its brand image by improving customer satisfaction. Predicting customer churn, which had been conducted as a sub-research area for CRM, has recently become more important as a big data-based performance marketing theme due to the development of business machine learning technology. Until now, research on customer churn prediction has been carried out actively in such sectors as the mobile telecommunication industry, the financial industry, the distribution industry, and the game industry, which are highly competitive and urgent to manage churn. In addition, These churn prediction studies were focused on improving the performance of the churn prediction model itself, such as simply comparing the performance of various models, exploring features that are effective in forecasting departures, or developing new ensemble techniques, and were limited in terms of practical utilization because most studies considered the entire customer group as a group and developed a predictive model. As such, the main purpose of the existing related research was to improve the performance of the predictive model itself, and there was a relatively lack of research to improve the overall customer churn prediction process. In fact, customers in the business have different behavior characteristics due to heterogeneous transaction patterns, and the resulting churn rate is different, so it is unreasonable to assume the entire customer as a single customer group. Therefore, it is desirable to segment customers according to customer classification criteria, such as loyalty, and to operate an appropriate churn prediction model individually, in order to carry out effective customer churn predictions in heterogeneous industries. Of course, in some studies, there are studies in which customers are subdivided using clustering techniques and applied a churn prediction model for individual customer groups. Although this process of predicting churn can produce better predictions than a single predict model for the entire customer population, there is still room for improvement in that clustering is a mechanical, exploratory grouping technique that calculates distances based on inputs and does not reflect the strategic intent of an entity such as loyalties. This study proposes a segment-based customer departure prediction process (CCP/2DL: Customer Churn Prediction based on Two-Dimensional Loyalty segmentation) based on two-dimensional customer loyalty, assuming that successful customer churn management can be better done through improvements in the overall process than through the performance of the model itself. CCP/2DL is a series of churn prediction processes that segment two-way, quantitative and qualitative loyalty-based customer, conduct secondary grouping of customer segments according to churn patterns, and then independently apply heterogeneous churn prediction models for each churn pattern group. Performance comparisons were performed with the most commonly applied the General churn prediction process and the Clustering-based churn prediction process to assess the relative excellence of the proposed churn prediction process. The General churn prediction process used in this study refers to the process of predicting a single group of customers simply intended to be predicted as a machine learning model, using the most commonly used churn predicting method. And the Clustering-based churn prediction process is a method of first using clustering techniques to segment customers and implement a churn prediction model for each individual group. In cooperation with a global NGO, the proposed CCP/2DL performance showed better performance than other methodologies for predicting churn. This churn prediction process is not only effective in predicting churn, but can also be a strategic basis for obtaining a variety of customer observations and carrying out other related performance marketing activities.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

Evaluation of usefulness of the Gated Cone-beam CT in Respiratory Gated SBRT (호흡동조 정위체부방사선치료에서 Gated Cone-beam CT의 유용성 평가)

  • Hong sung yun;Lee chung hwan;Park je wan;Song heung kwon;Yoon in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.61-72
    • /
    • 2022
  • Purpose: Conventional CBCT(Cone-beam Computed-tomography) caused an error in the target volume due to organ movement in the area affected by respiratory movement. The purpose of this paper is to evaluate the usefulness of accuracy and time spent using the Gated CBCT function, which reduces errors when performing RGRT(respiratory gated radiation therapy), and to examine the appropriateness of phase. Materials and methods: To evaluate the usefulness of Gated CBCT, the QUASARTM respiratory motion phantom was used in the Truebeam STxTM. Using lead marker inserts, Gated CBCT was scaned 5 times for every 20~80% phase, 30~70% phase, and 40~60% phase to measure the blurring length of the lead marker, and the distance the lead marker moves from the top phase to the end of the phase was measured 5 times. Using Cedar Solid Tumor Inserts, 4DCT was scanned for every phase, 20-80%, 30-70%, and 40-60%, and the target volume was contoured and the length was measured five times in the axial direction (S-I direction). Result: In Gated CBCT scaned using lead marker inserts, the axial moving distance of the lead marker on average was measured to be 4.46cm in the full phase, 3.11cm in the 20-80% phase, 1.94cm in the 30-70% phase, 0.90cm in the 40-60% phase. In Fluoroscopy, the axial moving distance of the lead marker on average was 4.38cm and the distance on average from the top phase to the beam off phase was 3.342cm in the 20-80% phase, 3.342cm in the 30-70% phase, and 0.84cm in the 40-60% phase. Comparing the results, the difference in the full phase was 0.08cm, the 20~80% phase was 0.23cm, the 30~70% phase was 0.10cm, and the 40~60% phase was 0.07cm. The axial lengths of ITV(Internal Target Volume) and PTV(Planning Target Volume) contoured by 4DCT taken using cedar solid tumor inserts were measured to be 6.40cm and 7.40cm in the full phase, 4.96cm and 5.96cm in the 20~80% phase, 4.42cm and 5.42cm in the 30~70% phase, and 2.95cm and 3.95cm in the 40~60% phase. In the Gated CBCT, the axial lengths on average was measured to be 6.35 cm in the full phase, 5.25 cm in the 20-80% phase, 4.04 cm in the 30-70% phase, and 3.08 cm in the 40-60% phase. Comparing the results, it was confirmed that the error was within ±8.5% of ITV Conclusion: Conventional CBCT had a problem that errors occurred due to organ movement in areas affected by respiratory movement, but through this study, obtained an image similar to the target volume of the setting phase using Gated CBCT and verified its usefulness. However, as the setting phase decreases, the scan time was increases. Therefore, considering the scan time and the error in setting phase, It is recommended to apply it to patients with respiratory coordinated stereotactic radiation therapy using a wide phase of 30-70% or more.