• Title/Summary/Keyword: Image Study

Search Result 20,969, Processing Time 0.053 seconds

A Study on the Temperature fronts observed in the South-West Sea of Korea and the Northern Area of the East China Sea (한국 남$\cdot$서해 및 동중국해 북부해역에 출현하는 수온전선)

  • YANG Young Jin;KIM Sang Hyun;RHO Hong Kil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.5
    • /
    • pp.695-706
    • /
    • 1998
  • SST (Sea Surface. Temperature) fronts which were found in the South-West Sea of Korea and the northern area of the East China Sea were examined in order to clarify their positions, shapes, seasonal changes and the formation mechanism, For this study used SST data rearranged from the SST IR image during 1991 to 1996 and oceanographical data obtained by National Fisheries Research and Development Institute. Temperature front in the Cheju Strait was analyzed by the data obtained from a fisheries guidance ship of Cheju Provincial Government, The coastal frontal zone in the South-West Sea of Korea and the offshore frontal zone in the northern area of the East China Sea can be divided into several types (Type of Winter, Summer, Spring, Autumn and late Autumn), Short term variations of SST fronts have a tendency not to move to any Bleat extent for several days. The location of the frontal zone in the southwestern sea of Cheju Island changes on a much large scale than that of the one in the southern coast of Korea, The frontal Tone, formed every year in the southern sea of Korea approaches closer to the coastal area in winter, and moves closer to the south in spring and autumn. The frontal zone of the southwestern sea of Cheju Island moves in a westerly direction from the east, and reaches its most westerly point in the winter and its most easterly point in the summer related to the seasonal change of the Tsushima Current. Additionally, the frontal zone of the southwestern sea of Korea becomes extremely weak in March, April and November. SST fronts are formed every year around the line connecting Cheju Island to Yeoseo Island or to Chungsan Island in the Cheju Strait. A Ring-shaped tidal mixing front appears along the coastal area of Cheju Island throughout the year except during the months from November to January. Especially, in May and October fronts are formed between the coastal waters of Cheju Island and the Tsushima currents connecting the frontal zone of the coastal region in the southern sea of Korea with that of the southwestern sea of Cheju Island.

  • PDF

A Study on Proposal of Landscape Management Improvement on the Quantitative Analysis of National Parks (국립공원(國立公園) 자연경관(自然景觀)의 계량적(計量的) 분석(分析)을 통(通)한 경관관리(景觀管理) 개선방안(改善方案)에 관(關)한 연구)

  • Kim, Sei Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.80 no.1
    • /
    • pp.32-41
    • /
    • 1991
  • This study is focusted to the national park of Korean typical mountain Chi-ri, its visual resources of forests, and practiced inspectind course by way of hypothesis and tests, to show visual resource management objectively, and that of quantitative basic data. spatial image structure measured by Semantic Differential(S.D.) Scale was shown through factor analysis algorithm for the analyzing psychological amount and examined the flowing out of decisive factor and the objective importance related mutual factors by appling the measurement of visual quality. Also, it has been investigated the differences between the degrees of expectation which is used before and of satisfaction which is used, by appling instrumental expectation theory. And showed patterns of investigation area through factor analyzing algorithm. As a national Park, visual factors that have natural landscape harmonized forest, sky, surface of the water, curious stones and rocks, temples should be escalate their values affirmatively so as to be the scenery of pointed direction and enjoyable, and it is needs the techniques visual resource management and its controlling technique to make artificial structures more intentional planning and systemical setting. Manmade distinctive quality in the spatials that affect complementally or harmonizingly, should be received considering relations between the distifution and joining which in line with various visual presenting massive factors. More than that, it is needed united basic standard to the beauty of arrangements which contain visual continuity considered balance between nature and human work, simplicity of structural types, assimilation, emphasis, unification of different factors and pro rata.

  • PDF

A Study on Case for Localization of Korean Enterprise in Indonesia (인도네시아 진출 한국기업의 현지화에 관한 사례 연구)

  • Swo, Min-Kyo;Kim, Hee-Jun
    • International Commerce and Information Review
    • /
    • v.15 no.4
    • /
    • pp.481-508
    • /
    • 2013
  • The purpose of this study is to research the specific ways of successful localization by analyzing the success and failures case for localization through the theoretical background and the strategic models of localization. The strategic models of localization are divided by management aspects such as the localization of production and sourcing, the localization of human resources, the localization of marketing, the localization of R&D, harmonious relationship with the local community and authority transfer between headquarters and local subsidiaries. And the specific measures of the successful localization are proposed within the framework of the strategic models by comparing and analyzing the success and failures case for localization of individual companies operating in Indonesia. The results indicate that there are successful companies which develop a suitable products for the local climate and failed automobile company which is weak for assembly of complete vehicle in terms of localization of production and sourcing. In case of localization of human resources, most companies recognize the importance of this part and endeavor to secure superior human resource through a related education. It is found that most of the companies perform R & D in their native country. In part of a harmonious relationship with the local community, Korean companies should contribute to the community and be friendly with local residents and make a good image of the company focusing on the cultural environment. In aspect of authority transfer between headquarters and local subsidiaries, there is a tendency to be determined by the head office rather than the joint participation. In the future, in order for Korean enterprise to be successful one in Indonesia market, a highly interdependent and complex forms between headquarters and local subsidiaries shall be performed and an active exchange of information and the selection of best talent regardless of nationality shall be promoted.

  • PDF

THE EFFECT OF LOW DIETARY CALCIUM AND IRRADIATION ON MANDIBLE IN RATS (저칼슘식이와 방사선조사가 백서 악골에 미치는 영향의 실험적 연구)

  • Lee Sun-Ki;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.229-250
    • /
    • 1993
  • This study was performed to investigate the morphological and structural changes of bone tissues and the effects of irradiation on the mandibular bodies of rats which were fed low calcium diets. In order to carry out this experiment, 160 seven-week old Sprague-Dawley strain rats weighing about 150 gm were selected and equally divided into one normal diet group of 80 rats and one low calcium diet group with the remainder. These groups were then subdivided into two groups, 40 were assigned rats for each subdivided group, exposed to radiation. The Group 1 was composed of forty non-irradiated rats with normal diet, Group 2 of forty irradiated rats with normal diet, Group 3 forty non-irradiated rats with low calcium diet, and Group 4 forty irradiated rats with low calcium diet. The two irradiation groups received a single dose of 20 Gy on the jaw area only and irradiated with a cobalt-50 teletherapy unit. The rats with normal and low calcium diet groups were serially terminated by ten on the 3rd, the 7th, the 14th, and the 21st day after irradiation. After termination, both sides of the dead rats mandible were removed and fixed with 10% neutral formalin. The bone density of mandibular body was measured by use of bone mineral densitometer(Model DPX -alpha, Lunar Corp., U.SA). Triga Mark ill nuclear reactor in Korea Atomic Research Institute was used for neutron activation and then calcium contents of mandibular body were measured by using a 4096 multichannel analyzer (EG and G ORTEC 919 MCA, U.SA). Also the mandibular body was radiographed with a soft X-ray apparatus(Hitex Co., Ltd., Japan). Thereafter, the obtained microradiograms were observed by a light microscope and were used for the morphometric analysis using a image analyzer(Leco 2001 System, Leco Co., Canada). The morphometric analysis was performed for parameters such as the total area, the bone area, the inner and outer perimeters of the bone. The obtained results were as follows: 1. In the morphometric analysis, total area and outer perimeter of the mandibular bodies of Group 3 were a little smaller than that of Group 1. The mean bone width and bone area were much smaller than that of Group 1 and the inner perimeter of Group 3 was much longer than that of Group 1. The total area and outer perimeter of Group 2 and Group 4 showed little difference. The mean bone width and bone area of Group 4 were smaller than that of Group 2 and the inner perimeter of Group 4 was longer than that of Group 2. 2. The remarkable decreases of the number and thickness of trabeculae and also the resorption of endosteal surface of cortical bone could be seen in the microradiogram of Group 3, Group 4 since the 3rd day of experiment. On the 21st day of experiment, the above findings could be more clearly seen in Group 4 than in Group 3. 3. The bone mineral density of Group 3 was lesser than that of Group 1 and the bone mineral density of Group 4 was lesser than that of Group 2 on the 7th, 14th, 21st days. The irradiation caused the bone mineral density to be decreased regardless of diet. In the case of Groups with low calcium diet, the bone mineral density was much decreased on the 21st day than on the 3rd day of experiment. 4. The calcium content in mandible of Group 3 was smaller than that of Group 1 throughout the experiment. roup 4 showed the least amount of calcium content. The irradiation caused the calcium content to be decreased regardless of diet. In the case of Groups with low calcium diet, the calcium content was much decreased on the 21st day than on the 3rd day of experiment. In conclusion, the present study demonstrated that morphological changs and decrease of bone mass due to resorption of bone by low calcium diet, and that the resorption of bone could be found in the spongeous bone and endosteal surface of cortical bone. So the problem of resorption of bone must be considered when the old and the postmenopausal women are taken radiotherapy because the irradiation seems to be accelerated the resorption of osteoporotic bone.

  • PDF

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

MR Imaging Findings of Uterine Cervical Adenocarcinoma (자궁경부 선암종의 자기공명영상 소견)

  • 김종철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.113-119
    • /
    • 1998
  • Purpose : Because adenocarcinomas of the uterine cervix have lower 5-year survival rate than squamous cell carcinomas due to early lymph node metastasis and local extension, scrutiny of lymph node metastasis and local extension by radiologic examination is necessary in case of clinically diagnosed or suspected adenocarcinomas. The purpose of this study is to evaluate whether there are specific findings of these tumors, compared with squamous cell carcinomas, through the analysis of magnetic resonance (MR) imaging findings. Materials and Methods : Of 21 pathologically proven cervical adenocarcinomas, MR imaging findings of 18 tumors (histologic staging : two Ib, four IIa, two IIb, one IIIa, and one IIIb) were retrospectively analyzed and compared with those of 40 wquamous cell carcinoma in consecutive patients as a control group. T1-wetighted and fast spin echo T2-weighted images were obtained on the axial and sagittal planes, using a 1.5-T MR scanner. The largest diameter, location, signal intensity and degree of contrast enhancement contour, shape and longitudinal extent of the tumor and associated findings on MR image were analyzed. Results : The largest diameters of cervical adenocarcinomas ranged from 0.8 to 4.1 cm(mean, 2.2 cm). Of 18 adenocarcinomas, nine were of endocervical type. All adenocarcinomas were isointense to surrounding cervical stroma on T1-weighted images and hyperintense(homogeneous in ten, inhomogeneous in eight) on fast spin echo T2-weighted images. Adenocarcinomas enhanced on contrast study in all patients (homogeneous in six, inhomogeneous in 12 with hyperintese enhnacing rim in two). Eight adenocarcinomas had smooth contours and ten had irregular ones. The shape of adenocarcinoma was irregular in eight patients, barrel shape in six, papillary/polypod in three, and nodular in one. All adenocarcinomas involved lower half of the uterine cervix and six tumors extended up to the upper half. Pelvic lymph nodes of more than 1.5cm in diameter in two adenocarcinomas pateints and no detectable small pelvic lymph nodes on MR imaging in one patient were pathologically positive. Hydrometra was associated in two adenocarcinomas patients, and hematometra in one patient. Compared with squamous cell carcinomas, more frequent MR findings of endocervical type and barrel shape in cervical adenocarcinomas were statistically significant. Conclusion : Cervical adenocarcinomas had more frequent MR findings of endocervical type and barrel shape, compared with wquamous cell carcinomas. Adenocarcinoma of the uterine cervix may be suspected on MR imaging, when a cervical carcinoma is of barrel shape along the endocervical canal and tends to involve lymth nodes in earlier stages.

  • PDF

Diagnostic Accuracy and Evaluation of Myocardial Viability by Cardiac Magnetic Resonance Imaging in Acute Myocardial Infarction: A Comparison with Thallium-201 Myocardial SPECT (급성심근경색증에서의 심장자기공명영상술의 진단 정확도와 심근 생존력 평가: TI-201 심근관류 SPECT와의 비교)

  • Kim Hye-seon;Park Dong Woo;Kim Yongsoo;Kim Young-sun;Choi Yo Won;Jeon Seok Chul;Seo Heung Suk;Hahm Chang Kok;Kim Soon Kil;Ahn You hern;Choi Yoon Young;Park Choong-Ki
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 2003
  • Purpose : To assess the usefulness of cardiac MR imaging (MRI) in the diagnosis of acute myocardial infarction and in the assessment of myocardial viability in comparision with T1-201 SPECT. Materials and Methods : We retrospectively studied 17 patients who complained of chest pain and dyspnea with cardiac MRI . The patients were evaluated for the presence or absence of high signal intensity on T2-weighted image (T2wI), abnormal wall motion on 2D-FIESTA, perfusion defect on Gd-DTPA enhanced T1WI, and delayed myocardial enhancement on 15-minutes delay Gd-DTPA enhanced T1WI. The results were correlated with the images on T1-201 SPECT, taken at rest and stress, through which reversibility of perfusion defect was assessed. Results : Both cardiac MRI and T1-201 SPECT proved to be useful methods for diagnosing acute myocardial infarction. In order of decreasing correspondence, T2WI, T1-201 SPECT, delayed enhancement study, and wall motion images all showed significant statistical correlation with the clinical diagnosis of myocardial infarction. Perfusion MRI, on the other hand, showed no significant statistical difference was found between T1-201 SPECT and cardiac MRI. The results on T2WI showed high accordance with those on Tl-201 SPECT, while delayed myocardial enhancement and wall motion studies showed no agreement with Tl-201 SPECT. Conclusion : Cardiac MRI is useful method for diagnosis of acute myocardiac infarction. With respect to the assessment of myocardial viability, the results obtained on cardiac MRI showed high agreement with those on Tl-201 SPECT. However, further study is necessary at this point for standardization and establishment of the methods for assessing myocardial viability on cardiac MRI.

  • PDF

Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method (Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법)

  • Han, Yong-Hee;Kim, Tae-Hyung;Chun, Song-I;Kim, Dong-Hyeuk;Lee, Kwang-Sig;Eun, Choong-Ki;Jun, Jae-Ryang;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • Purpose : This study proposes the keyhole method in order to improve the time resolution of the proton resonance frequency(PRF) MR temperature monitoring technique. The values of Root Mean Square (RMS) error of measured temperature value and Signal-to-Noise Ratio(SNR) obtained from the keyhole and full phase encoded temperature images were compared. Materials and Methods : The PRF method combined with GRE sequence was used to get MR temperature images using a clinical 1.5T MR scanner. It was conducted on the tissue-mimic 2% agarose gel phantom and swine's hock tissue. A MR compatible coaxial slot antenna driven by microwave power generator at 2.45GHz was used to heat the object in the magnetic bore for 5 minutes followed by a sequential acquisition of MR raw data during 10 minutes of cooling period. The acquired raw data were transferred to PC after then the keyhole images were reconstructed by taking the central part of K-space data with 128, 64, 32 and 16 phase encoding lines while the remaining peripheral parts were taken from the 1st reference raw data. The RMS errors were compared with the 256 full encoded self-reference temperature image while the SNR values were compared with the zero filling images. Results : As phase encoding number at the center part on the keyhole temperature images decreased to 128, 64, 32 and 16, the RMS errors of the measured temperature increased to 0.538, 0.712, 0.768 and 0.845$^{\circ}C$, meanwhile SNR values were maintained as the phase encoding number of keyhole part is reduced. Conclusion : This study shows that the keyhole technique is successfully applied to temperature monitoring procedure to increases the temporal resolution by standardizing the matrix size, thus maintained the SNR values. In future, it is expected to implement the MR real time thermal imaging using keyhole method which is able to reduce the scan time with minimal thermal variations.

  • PDF

A Radiologic Study of the Relationship of the Maxillary Sinus Floor and Apex of the Maxillary Molar (상악동 아래벽과 상악 대구치 치근사이 위치관계에 관한 방사선학적 연구)

  • Yoon Hae-Rym;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.111-126
    • /
    • 1998
  • In this study, radiographic evaluation was made using panoramic radiography and cross-sectional tomography of SCANORA/sup (R)/ in male and female adults in their 20's on the relationship between the maxillary sinus floor and the apex of the maxillary molar, to test the accuracy and effectiveness of the cross-sectional tomography, and to use this information in the assessment of preop. and postop. root canal treatment, apical surgery, extraction and implantology. Forty-one adults with an average age of 24.4 years were studied using panoramic radiography and cross-sectional tomography. In panoramic view and cross-sectional view, the position of the apices of maxillary molars were classified as separated, contacted, or protruded type; the general shape of the maxillary sinus floor was evaluated horizontally and vertically from cross-sectional tomography. The accuracy of each radiography was tested using maxilla from 5 fresh cadavers from the Anatomy Lab at Yonsei University Dental College, and panoramic view and cross-sectional tomography were taken in the same condition as with the patients. The results were as follows: 1. Panoramic view and cross-sectional view were taken in the maxilla specimen, and the actual distance between the maxillary sinus floor and the tooth apices were measured in the specimen; the median values of the distance from the tooth apices to the maxillary sinus floor in the panoramic view, cross-sectional view and in the actual maxilla specimen were 2.83 mm, 4.51mm, and 4.l5mm, respectively. In the cross-sectional view, the measured distance was close to the actual distance but in the panoramic view, the measured distance was far from the actual distance. 2. When the results of the panoramic view and cross-sectional view were compared, 40.5% of the results agreed with each other in the two radiographic methods and buccal roots of the 2nd molar were the closest to the maxillary sinus floor in the cross-sectional tomography. 3. In cross-sectional view, when the vertical relationship of the maxillary sinus floor and maxillary roots was assessed, in 1st molars, type II (the sinus floor that extends down to the buccolingual furcation area) was predominant, while in 2nd molars, type I (the sinus floor located above the level connecting the buccal and lingual apices) was predominant. In the horizontal relationship, in 1st molars, type II (the lowest floor of the maxillary sinus located in between the buccal and lingual roots) was predominant; in 2nd molars, type I (the lowest floor of the maxillary sinus located on the buccal side of the buccal roots) and type II appeared in similar frequency. In conclusion, the SCANORA/sup (R)/ cross-sectional tomography was more effective than the frequently used panoramic view, in that the relationship of the maxillary molars and maxillary sinus floor can be evaluated more accurately and the buccolingual cross-sectional view can also be observed. And maxillary sinus floor that was close to maxillary 2nd molar had tendency to be located on buccal side than that close to 1st molar. Therefore, cross-sectional tomography is an effective and accurate method to evaluate the position of the teeth in relation to the sinus floor preoperative and can be easily used to diagnose localized periapical lesions. Also, the image quality obtained was quite satisfactory.

  • PDF

Biological stability of Zirconia/Alumina composite ceramic Implant abutment (지르코니아/알루미나 복합 지대주의 생물학적 안정성에 관한 연구)

  • Bae, Kyu-Hyun;Han, Jung-Suk.;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Cho, Ki-Young;Chung, Chong-Pyoung;Han, Soo-Boo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.555-565
    • /
    • 2006
  • The purpose of the present study is to evaluate the biological stability of the zirconia/alumina composite abutment by histologic and radiographic examination in clinical cases. 17 partially edentulous patients (5 men and 12 women, mean age 47) were treated with 37 implants. The implants were placed following the standard two-stage protocol. After a healing period of 3 to 6 months, zirconia/alumina composite abutments were connected. All radiographs were taken using paralleling technique with individually fabricated impression bite block, following insertion of the prosthesis and at the 3-, 6-, 12 month re-examinations. After processing the obtained images, the osseous level was calculated using the digital image in the mesial and distal aspect in each implant. An ANOVA and t-test were used to test for difference between the baseline and 3-, 6-, 12 months re-examinations, and for difference between maxilla and mandible. Differences at P <0.05 were considered statistically significant. For histologic examination, sample was obtained from the palatal gingiva which implant functioned for 12 months. Sections were examined under a light microscope under various magnifications. Clinically, no abutment fracture or crack as well as periimplantitis was observed during the period of study. The mean bone level reduction(${\pm}standard$ deviation) was 0.34 rom(${\pm}\;0.26$) at 3-months, 0.4 2mm(${\pm}\;0.30$) at 6-months, 0.62 mm(${\pm}\;0.28$) at 12-months respectively. No statistically significant difference was found between baseline and 3-, 6-, 12-months re-examinations (p > 0.05). The mean bone level reduction in maxilla was 0.33(${\pm}0.25$) at 3-months, 0.36(${\pm}0.33$) at 6-months, 0.56(${\pm}0.26$) at 12-months. And the mean bone level reduction in mandible was 0.35(${\pm}0.27$) at 3-months, 0,49(${\pm}0.27$) at 6-months, 0.68(${\pm}0.30$) at 12-months. No statistical difference in bone level reduction between implants placed in the maxilla and mandible. Histologically, the height of the junctional epithelium was about 2.09 mm. And the width was about 0.51 mm. Scattered fibroblasts and inflammatory cells, and dense collagen network with few vascular structures characterized the portion of connective tissue. The inflammatory cell infiltration was observed just beneath the apical end of junctional epithelium and the area of direct in contact with zirconia/alumina abutment. These results suggest the zirconia/alumina composite abutment can be used in variable intraoral condition, in posterior segment as well as anterior segment without adverse effects.