• 제목/요약/키워드: Image Ratio

검색결과 2,755건 처리시간 0.035초

흉부질환의 화질과 피폭을 고려한 촬영조건의 연구 (A Study on the Chest Radiography with Diseases in Consideration of Image Qualify and Patient Exposure)

  • 이만구;임태랑;석전유치
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.56-62
    • /
    • 1997
  • To evaluated the image quality and the patient exposure for the chest radiography, its fundamental imaging properties were investigated. The basic imaging properties were evaluated by measuring characteristic curves, relative speeds, average gradient, and patient exposure dose. The image qualities were evaluated by using a rotating meter. It was found that the film gradient of SRO750/SRH system was 3.13 and that of SRO750/HR-C30 was 1.77. The ratio of SRO1000/TMH to FS/RP-1 was 1 to 18.2. It was possible to visualize the static image when the exposure time was less than 2.5 msec in patient that had respiratory excessive motion, heart beat and natural physical motion, and less than 8.5 msec in normal. The ratio of medical exposure dose compared with our method was 1 to 25 in the routine chest radiography and maximum was 1 to 70. In estimation of the image quality in same cases, we found that the image of SRO1000/SRH and TMH of super sensitive systems was the same results. We found that these super sensitive screen-film systems were available for the chest radiography considering the relationship between the image quality and patient exposure.

  • PDF

Performance analysis of improved hybrid median filter applied to X-ray computed tomography images obtained with high-resolution photon-counting CZT detector: A pilot study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3380-3389
    • /
    • 2022
  • We evaluated the performance of an improved hybrid median filter (IHMF) applied to X-ray computed tomography (CT) images obtained using a high-resolution photon-counting cadmium zinc telluride (CZT) detector. To study how the proposed approach improves the image quality, we measured the noise levels and the overall CT-image quality. We established a CZT imaging system with a detector length of 5.12 cm and thickness of 0.3 cm and acquired phantom images. To evaluate the efficacy of the proposed filter, we first modeled two conventional median filters. Subsequently, we were able to achieve a normalized noise power spectrum result of ~10-8 mm2, and furthermore, the proposed method improved the contrast-to-noise ratio by a factor of ~1.51 and the coefficient of variation by 1.55 relative to the counterpart values of the no-filter image. In addition, the IHMF exhibited the best performance among the three filters considered as regards the peak signal-to-noise ratio and no-reference-based image-quality evaluation parameters. Thus, our results demonstrate that the IHMF approach provides a superior image performance over conventional median filtering methods when applied to actual CZT X-ray CT images.

Image Quality and Lesion Detectability of Lower-Dose Abdominopelvic CT Obtained Using Deep Learning Image Reconstruction

  • June Park;Jaeseung Shin;In Kyung Min;Heejin Bae;Yeo-Eun Kim;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • 제23권4호
    • /
    • pp.402-412
    • /
    • 2022
  • Objective: To evaluate the image quality and lesion detectability of lower-dose CT (LDCT) of the abdomen and pelvis obtained using a deep learning image reconstruction (DLIR) algorithm compared with those of standard-dose CT (SDCT) images. Materials and Methods: This retrospective study included 123 patients (mean age ± standard deviation, 63 ± 11 years; male:female, 70:53) who underwent contrast-enhanced abdominopelvic LDCT between May and August 2020 and had prior SDCT obtained using the same CT scanner within a year. LDCT images were reconstructed with hybrid iterative reconstruction (h-IR) and DLIR at medium and high strengths (DLIR-M and DLIR-H), while SDCT images were reconstructed with h-IR. For quantitative image quality analysis, image noise, signal-to-noise ratio, and contrast-to-noise ratio were measured in the liver, muscle, and aorta. Among the three different LDCT reconstruction algorithms, the one showing the smallest difference in quantitative parameters from those of SDCT images was selected for qualitative image quality analysis and lesion detectability evaluation. For qualitative analysis, overall image quality, image noise, image sharpness, image texture, and lesion conspicuity were graded using a 5-point scale by two radiologists. Observer performance in focal liver lesion detection was evaluated by comparing the jackknife free-response receiver operating characteristic figures-of-merit (FOM). Results: LDCT (35.1% dose reduction compared with SDCT) images obtained using DLIR-M showed similar quantitative measures to those of SDCT with h-IR images. All qualitative parameters of LDCT with DLIR-M images but image texture were similar to or significantly better than those of SDCT with h-IR images. The lesion detectability on LDCT with DLIR-M images was not significantly different from that of SDCT with h-IR images (reader-averaged FOM, 0.887 vs. 0.874, respectively; p = 0.581). Conclusion: Overall image quality and detectability of focal liver lesions is preserved in contrast-enhanced abdominopelvic LDCT obtained with DLIR-M relative to those in SDCT with h-IR.

아세톤 형광을 이용한 공연비 측정 기법 연구 (An Experimental Investigation of Air Fuel Ratio Measurement using Laser Induced Acetone Fluorescence)

  • 박승재;허환일;오승묵
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.353-356
    • /
    • 2002
  • Planar laser induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Preliminary investigation was performed to measure quantitative air excess ratio distribution in an engine fueled with LPG. It is known that fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone was excited by KrF excimer laser (248nm) and its fluorescence image was acquired by ICCD camera with a cut-of filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile was suggested. Raw images were divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which was taken by a calibration process, were converted to air excess ratio distribution. This investigation showed instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

  • PDF

SAP 잡음 제거를 위한 적응적 스위칭 필터링 알고리즘 (Adaptive Switching Filtering Algorithm for SAP noise)

  • 김동형
    • 디지털산업정보학회논문지
    • /
    • 제18권1호
    • /
    • pp.25-35
    • /
    • 2022
  • The SAP(salt-and-pepper) noise changes the pixel value to the maximum and minimum values of the dynamic region of the pixel. For this reason, unlike white Gaussian noise, SAP noise can predict the ratio of noise relatively easily. Because the condition of the neighboring pixels that can be referenced changes according to the noise ratio, it is necessary to apply different noise reduction methods according to the noise ratio. This paper proposes an adaptive switching filtering algorithm which can eliminates the SAP noise. It consists of two phases. It first detects the location of the SAP noise and calculates the noise ratio. After that, the image is reconstructed using different methods depending on which of the three sections the calculated noise ratio belongs to. As a result of the experiment, the proposed method showed superior objective and subjective image quality compared to the previous methods such as MF, AFSWMF, NAMF and RWMF.

감마카메라 영상에서 분해능 향상을 위한 Xact-bone의 유용성 평가 (Usefulness of Xact-bone for the Resolution Advancement of Gamma Camera Image)

  • 김종필;윤석환;임정진;우재룡
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.30-35
    • /
    • 2011
  • 현재 분해능 향상을 위한 프로그램인 Wide beam reconstruction (WBR: UltraSPECT, Israel) 을 사용하고 있다. WBR에 속해있는 Xact-Bone은 Planar영상과 Single photon emission computed tomography (SPECT) 영상의 분해능과 대조도를 향상시켜 상당한 영상의 질 향상에 도움을 준다고 보고 되어있다. 본 연구는 Xact-Bone의 임상적용에 대한 유용성을 알아보고자 한다. Xact-Bone에서의 유용성 평가는 분해능 평가와 Contrast Ratio를 비교분석하였다. Planar영상에서의 분해능 평가는 capillary tube를 이용하여 Full width at half maximum (FWHM)을 구하였고, Contrast Ratio분석은 2010년 1월부터 2010년 10월까지 bone scan 검사를 위해 본원에 내원한 50명의 환자 Xact-Bone의 사용 전 후 영상에서 Bone and Soft tissue (B/S) ratio 값을 비교 평가하였다. SPECT영상에서의 분해능 평가는 Triple Line Source Phantom을 이용하여 FWHM을 구하였고, Contrast Ratio 비교 분석은 NEMA IEC Body Phantom과 Standard Jaszczak Phantom을 이용하여 획득한 영상을 각각 Filtered backprojection (FBP), Orderd subset expectation maximization (OSEM), Xact-Bone으로 재구성하여 비교하였다. Planar영상에서의 유용성 평가는 capillary tube를 이용한 실험결과, FWHM은 기존의 Planar영상보다 WBR의 Xact-Bone 프로그램을 이용한 재구성 영상에서 약 20% 향상되었으며, B/S ratio값도 약 15% 향상되었다. SPECT영상의 유용성 평가는 Triple line Source Phantom을 이용한 실험결과, FWHM은 Xact-Bone이 FBP, OSEM 기법보다 각각 20%, 10% 향상되었다. 또한 NEMA IEC body Phantom을 이용한 Contrast Ratio 비교분석결과 각각 20%, 10% 향상되었고, Standard Jaszczak Phantom을 이용한 Contrast Ratio 비교분석 결과는 각각 90%, 50% 향상되었다. WBR의 Xact-bone 프로그램을 이용한 Planar 영상에서는 사용하지 않은 경우와 비교하였을 경우 상당한 영상의 분해능과 Contrast Ratio가 향상됨을 알 수 있었고, SPECT영상에서 기존의 FBP, OSEM 영상재구성 방법보다 분해능, Contrast Ratio가 향상됨을 알 수 있었다. 이에 WBR의 Xact-Bone을 이용함으로써 영상의 질적 향상이 기대되는 바이다. 하지만, 새로운 소프트웨어 도입시 병원의 특성에 맞는 protocol 과 임상적용이 필요하다고 사료된다.

  • PDF

DCT 영역에서 영상의 임의 비율 크기 변환을 위한 새로운 알고리즘 (New Algorithm for Arbitrary-ratio Image Resizing in DCT Domain)

  • 김용재;이창우
    • 한국통신학회논문지
    • /
    • 제32권2C호
    • /
    • pp.113-123
    • /
    • 2007
  • 유비쿼터스 통신 환경에서는 영상의 다양한 형태의 변환이 필수적인데, 대부분의 디지털 영상은 DCT (Discrete Cosine Transform)를 기반으로 한 JPEG, MPEG 등의 표준 기법을 이용하여 압축되어 저장되어 있다. 본 논문에서는 DCT 영역에서 영상의 크기를 변환시키는 기존의 여러 가지 알고리즘들을 고찰하고 그 성능을 분석하며, 기존의 방법보다 더 우수한 성능을 보이는 DCT 영역에서의 영상 크기 변환 알고리즘을 제안한다. 제안하는 알고리즘은 DCT 영역에서 영상의 임의 크기 변환을 위해 여러 개의 $8{\times}8$ DCT 계수 블록을 변환 비율에 따라 변환식을 통하여 하나의 블록으로 변환하고 최적의 zero-padding 및 truncating을 위한 IDCT의 크기를 정하는 방법을 이용하여 영상 크기 변환의 성능을 높인다. 이것은 화소간의 상관도를 최대한 이용하여 DCT 계수를 구하고, 여기서 얻어진 DCT 계수 블록에서 원하는 비율에 따라 최적의 크기를 구함으로써 성능을 높이는 알고리즘이다. 그 성능을 원 영상과 축소하여 다시 확대시킨 영상의 PSNR 비교를 통하여 확인하였고, 제안하는 알고리즘은 특정 비율의 변환에 있어서 기존의 알고리즘을 포괄할 수 있는 방법임을 확인할 수 있었다.

RMA를 이용한 Spotlight SAR 영상형성 및 품질평가를 위한 시뮬레이터 개발 및 구현 (Development and application of simulator for spotlight SAR image formation and quality assesment using RMA)

  • 곽준영
    • 한국항공우주학회지
    • /
    • 제39권2호
    • /
    • pp.183-194
    • /
    • 2011
  • 합성 개구면 레이다(SAR: synthetic aperture radar)는 날씨 및 주/야간에 관계없이 고해상도의 영상을 형성할 수 있기 때문에 다양한 분야에서 활용되고 있다. 본 논문에서는 영상 형상 및 품질 평가, 분석을 위한 Spotlight SAR 시뮬레이터를 제안한다. SAR 영상 품질의 예측은 초기 개념 설계 단계부터 최종적인 비행 검증 및 보정 단계에 걸쳐 필수적이다. 제안된 SAR 시뮬레이터는 시스템 설계 변수들에 기반을 두고 있어 전체 시스템 개발과정에서 SAR 영상의 품질을 예측 분석할 수 있다. 이를 위해 영상 획득 기하구조와 다양한 SAR 시스템 설계변수들을 고려하여 이상적인 점표적에 대한 시뮬레이션 원시 데이터를 생성하고 Spotlight 영상 형성 알고리듬을 구현함으로서 점표적 응답특성을 추정한다. 마지막으로 공간 해상도, 최대 부엽 수준, 누적 부엽 수준 등의 주요 품질변수들을 중심으로 생성된 원시 데이터의 영상 품질을 분석한다.

광학 현미경 영상 기반 시간 분해능이 향상된 비지역적 평균 노이즈 제거 알고리즘 가능성 연구 (Feasibility Study of Non Local Means Noise Reduction Algorithm with Improved Time Resolution in Light Microscopic Image)

  • 이영진;김지연
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.623-628
    • /
    • 2019
  • 본 연구의 목적은 시간 분해능이 향상된 비지역적 평균 (fast non local means, FNLM) 노이즈 제거 알고리즘을 모델링하여 광학 현미경 영상에서의 적용 가능성을 확인하는 것이다. 이를 위해 실제 흰쥐 (mouse)의 첫째어금니 치아를 사용하여 영상을 획득한 후 기존에 널리 사용되고 있는 노이즈 제거 알고리즘과 제안하는 FNLM 알고리즘을 각각 적용하여 비교하였다. 정량적 평가는 대조도 대 잡음비 (contrast to noise ratio, CNR), 변동계수 (coefficient of variation, COV), 그리고 최근에 개발된 no reference 기반의 방법인 natural image quality evaluator (NIQE)와 Blind/referenceless image spatial quality evaluator (BRISQUE)를 사용하였다. 결과적으로 모든 정량적 평가 인자에서 제안하는 FNLM 노이즈 제거 알고리즘이 가장 우수한 값을 나타내었다. 특히나 치아의 전체적인 형태학적 영상을 분석할 수 있는 NIQE와 BRISQUE 인자는 원본영상에 비하여 각각 1.14와 1.12배 향상됨을 확인할 수 있었다. 결론적으로 소동물 치아 광학 현미경 영상에서의 FNLM 노이즈 제거 알고리즘의 유용성 및 가능성을 증명하였다.

교류 계수 분할 압축에 의한 JPEG 정지영상 압축 효율 향상 기법 연구 (On Improving Compression Ratio of JPEG Using AC-Coefficient Separation)

  • 안영훈;신현준;위영철
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제16권1호
    • /
    • pp.29-35
    • /
    • 2010
  • 본 논문에서는 JPEG 표준의 엔트로피 부호화 과정을 개선하여 압축률을 향상시키기 위한 방법을 제안한다. JPEG은 비교적 높은 화질 대비 압축률을 가지며, 특히 부호화와 복호화가 매우 효율적이어서 많은 응용에 사용된다. 본 논문에서는 JPEG의 이산 코사인 변환과 양자화, 재정렬 등의 과정을 거친 정보에 0, -1, 1등의 작은 값들이 연속적으로 나타난다는 관찰 결과에 착안하여 이들을 분리하고 JPEG의 방식 보다 효율적인 방법으로 엔트로피 부호화 함으로써 압축률을 향상시키는 방법을 제안한다. 이와 같은 방법을 통하여 다양한 화질의 영상에서 JPEG보다 높은 압축률을 얻을 수 있음을 실험적으로 확인하였다.