• Title/Summary/Keyword: Image Quality

Search Result 6,246, Processing Time 0.035 seconds

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

Effect of Noise on Density Differences of Tissue in Computed Tomography (컴퓨터 단층촬영의 조직간 밀도차이에 대한 노이즈 영향)

  • Yang, Won Seok;Son, Jung Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.403-407
    • /
    • 2018
  • Currently, the highest cancer death rate in Korea is lung cancer, which is a typical cancer that is difficult to detect early. Low-dose chest CT is being used for early detection, which has a greater lung cancer diagnosis rate of about three times than regular chest x-ray images. However, low-dose chest CT not only significantly reduces image resolution but also has a weak signal and is sensitive to noise. Also, air filled lungs are low-density organs and the presence of noise can significantly affect early diagnosis of cancer. This study used Visual C++ to set a circle inside a large circle with a density of 2.0, with a density of 1.0, which is the density of water, in which five small circle of mathematics have different densities. Gaussian noise was generated by 1%, 2%, 3%, and 4% respectively to determine the effect of noise on the mean value, the standard deviation value, and the relative noise ratio(SNR). In areas where the density difference between the large and small circles was greatest in the event of 1 % noise, the SNR in the area with the greatest variation in noise was 4.669, and in areas with the lowest density difference, the SNR was 1.183. In addition, the SNR values can be seen to be high if the same results are obtained for both positive and negative densities. Quality was also clearly visible when the density difference was large, and if the noise level was increased, the SNR was reduced to significantly affect the noise. Low-density organs or organs in areas of similar density to cancers, will have significant noise effects, and the effects of density differences on the probability of noise will affect diagnosis.

Implementation of Radiotherapy Educational Contents Using Virtual Reality (가상현실 기술을 활용한 방사선치료 교육 콘텐츠 제작 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.409-415
    • /
    • 2018
  • The development of smart devices has brought about significant changes in daily life and one of the most significant changes is the virtual reality zone. Virtual reality is a technology that creates the illusion that a 3D high-resolution image has already been created using a display device just like it does in itself. Unrealized subjects are forced to rely on audiovisual materials, resulting in a decline in the concentration of practices and the quality of classes. It used virtual reality to develop effective teaching materials for radiology students. In order to produce a video clip bridge using virtual reality, a radiology clinic was selected to conduct two exposures from July to September 2017. The video was produced taking into account the radiology and work flow chart and filming was carried out in two separate locations : in the computerized tomography unit and in the LINAC room. Prior to filming the scenario and the filming route were checked in advance to facilitate editing of the video. Modeling and mapping was performed in a PC environment using the Window XP operating system. Using two leading virtual reality camera Gopro Hero, CC pixels were produced using a 4K UHD, Adobe, followed by an 8 megapixel resolution of $3,840{\times}2,160/4,096{\times}2,160$. Total regeneration time was performed in about 5 minutes during the production of using virtual reality to prevent vomiting and dizziness. Currently developed virtual reality radiation and educational contents are being used to secure the market and extend the promotion process to be used by various institutions. The researchers will investigate the satisfaction level of radiation and educational contents using virtual reality and carry out supplementary tasks depending on the results.

Research on Mobile Wheelchair Lift Design (이동식 휠체어 리프트 디자인 연구)

  • 이명기
    • Archives of design research
    • /
    • v.15 no.4
    • /
    • pp.275-284
    • /
    • 2002
  • To improve the social and economic position of the disabled people and secure their human rights, an integrated society should be buill. To build such a society, an adequate access should be provided to the movement or in using buildings or facilities. The inconveniences from social life on the part of the disabled people might not result from their impairment or disability, but from physical and social barriers in the environment surrounding them. Therefore, it is necessary to reconstruct entire systems of the society as a disabled people-friendly structure in order to remove those barriers, make them stand their own feet in our communities and freely participate in the social activities. This will eventually lead to build a society in which all people including the disabled people can use those facilities in a more convenient way. It is almost impossible for the disabled people to safely and conveniently access to and use facilities and equipments and freely move to their desired places, without any help from others in Korea. Even though, there are currently many disabled people-related convenience facilities, they have been independently built without a connection with other facilities and buildings, thus not greatly useful. Even when convenience facilities have been built, mostly they are superficially set up; therefore, in many cases, the disabled peOple cannot use those facilities. In this. research, I tried a new concept of mobile wheelchair lift design, which the disabled people can operate without restrictions, when using the public facilities. The key to this research was to develop the existing import-oriented simple functional products to a new system with functional safety and high quality orientation. Also, this research aimed at bringing an. import substitution effect, as well as preempting the mobile wheelchair lift market by advancing into overseas markets through application of new image designs in the field of disabled people aid equipments.

  • PDF

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

A Web-based 'Patterns of Care Study' System for Clinical Radiation Oncology in Korea: Development, Launching, and Characteristics (우리나라 임상방사선종양을 위한 웹 기반 PCS 시스템의 개발과 특성)

  • Kim, Il Han;Chie, Eui Kyu;Oh, Do Hoon;Suh Chang-Ok;Kim, Jong Hoon;Ahn, Yong Chan;Hur, Won-Joo;Chung, Woong Ki;Choi, Doo Ho;Lee, Jae Won
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.291-298
    • /
    • 2003
  • Purpose: We report upon a web-based system for Patterns of Care Study (PCS) devised for Korean radiation oncology. This PCS was designed to establish standard tools for clinical quality assurance, to determine basic parameters for radiation oncology processes, to offer a solid system for cooperative clinical studies and a useful standard database for comparisons with other national databases. Materials and Methods: The system consisted of a main server with two back-ups in other locations. The program uses a Linux operating system and a MySQL database. Cancers with high frequencies in radiotherapy departments in Korea from 1998 to 1999 were chosen to have a developmental priority. Results: The web-based clinical PCS .system for radiotherapy in www.pcs.re.kr was developed in early 2003 for cancers of the breast, rectum, esophagus, larynx and lung, and for brain metastasis. The total number of PCS study items exceeded one thousand. Our PCS system features user-friendliness, double entry checking, data security, encryption, hard disc mirroring, double back-up, and statistical analysis. Alphanumeric data can be input as well as image data. In addition, programs were constructed for IRB submission, random sampling of data, and departmental structure. Conclusion: For the first time in the field of PCS, we have developed a web-based system and associated working programs. With this system, we can gather sample data in a short period and thus save, cost, effort and time. Data audits should be peformed to validate input data. We propose that this system should be considered as a standard method for PCS or similar types of data collection systems.

Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD (평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석)

  • Park, Hye-Suk;Kim, Hee-Joung;Lee, Chang-Lae;Cho, Hyo-Min;Yu, A-Ram
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.21-29
    • /
    • 2009
  • Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important. A yearly mammography examination has been recommended for women aged 40 and older for the early detection of breast cancer in asymptomatic periods. However, the glandular tissue of breast is the most radiation-sensitive tissue, and the determination of average glandular dose (AGD) forms an important part of the quality control of the mammographic systems. Because of the difficulty of estimating AGD directly, it is often estimated from the measurements of the incident air kerma and by applying the appropriate conversion factors. The primary objective of this study was to standardize the method of measuring AGD. The secondary objective was to evaluate the relationships between AGD per various composition and thickness of the breast using Monte Carlo simulations. As a result, we standardized the method of measuring AGD according to International Atomic Energy Agency (IAEA) guidelines (CoP: an international code of practice). Overall, AGD for mammographic practice in Korea was less than 3.0 mGy recommended by the Korea Food and Drug Adminstration (KFDA) protocol, and Korean Institute for Accreditation of Medical Image (KIAMI). The measured and simulated AGD for a given condition were calculated as 1.7 and 1.6 mGy, respectively. For the AGDs obtained, there was no significant difference between them. The simulated AGD was dependent on the fraction of glandular tissue of the breast. The AGD increases with increasing of the breast glandularity due to increasing absorption of low energy photons. The AGD also increases as a function of breast thickness. In conclusion, the results of this study could be used as a baseline to establish a reference level of radiation dose in mammography.

  • PDF

The comparison of landmark identification errors and reproducibility between conventional lateral cephalometric radiography and digital lateral cephalometric radiography (일반두부방사선계측사진과 디지털방사선계측사진의 계측점 식별의 오차 및 재현성에 관한 비교 연구)

  • Lee, Yang-Ku;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.79-89
    • /
    • 2002
  • The purpose of this study is to evaluate the reproducibility and errors in landmark identification of conventional lateral cephalometric radiography and digital lateral cephalometric radiography. Fifteen conventional lateral cephalometric radiographs and fifteen digital lateral cephalometric radiographs were selected in adults with no considerations on sex and craniofacial forms. Each landmark was identified and expressed as the coordinate (x, y). The landmarks were classified into 3 groups. The landmarks of the first identification was T1, identification after one week was T2, and identification after one month was T3. The mean and standard deviation of identification errors between replicates were calculated according to the x and y coordinates. The errors between first identification and second identification were expressed as T2-T1(x), T2-T1(y) and those between first identification and third identification were expressed as T3-T1(x), T2-T1(y). Each was divided into conventional lateral cephalometric radiography and digital lateral cephalometric radiography. The independent t- test was used for statistical analysis of identification errors for the evaluation of reproducibility. The results of this study were as follows ; 1. Generally, the mean and standard deviation of landmark identification errors in digital lateral cephalometric radiography was smaller than those of conventional lateral cephalometric radiography. 2. Only a few landmarks showed statistically significant difference in identification error between conventional lateral cephalometric radiography and digital lateral cephalometric radiography. 3. The enhancement of image quality didn't guarantee decrease in landmark identification error and didn't affect tendency of landmark identification error.

A Research on Perception of Leadership Affects Long-term Working Intention in the Beauty Service Employees (미용서비스종사자의 리더십 지각이 장기근속의도에 미치는 영향에 관한 연구)

  • Oh, Jin Sook;Youn, Chun Sung
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.4
    • /
    • pp.21-32
    • /
    • 2012
  • The current beauty service of Korea is upgrading its outside appearance from traditional small-shop image and its speed of change and competition are more severe than ever before. The top priority trait of beauty management is based on man-power resource, and personnel-management is the most important thing that more than anything else. Compared with other arenas of business, personnel management plays a key role in beauty industry. As a result, this research begins with the issue of personnel management. In addition, I will show that the management leadership of beauty service affects organization civil actions and changing jobs in the beauty industry employees, and the leadership can lower changing job rate to some extent. The role and duty of business manager is very significant because the dependence of man-power resource is magnificent in beauty service. In spite of rapid changing of economic surroundings, the management of beauty service is still working without any detail plans. It is no exaggeration to say that the most of beauty service managers are lack of leadership conception. Although the demands of customers are changing everyday, the frequent changing of jobs among talented employees drops customers credibility and high-quality service. From a management viewpoint, re-training cost of employees leads to economic loss and the company suffers from financial problems. As a result, it creates vicious circle in the beauty industry. Today, the management atmosphere in the beauty service is hard to get its right track because of the cutthroat competitions of beauty industry and difficulties of hiring promising employees. It has been said that "Nothing ventured, Nothing gained" Above all, the beauty service requires job speciality and it produces economic profits. Therefore, the managers desperately need to change the way they regard those with job changers. In this research shows the principal index of the leadership type of beauty business managers how much affects its employees' long-term working condition. The new concept of leadership, such as alternative suggestions, setting goals, and organization civil action will reorganize the stereo-type frame. I will also investigate the factors of job changing and intention of the beauty service employees for the development option of the beauty industry.

  • PDF

Anisotropy Measurement and Fiber Tracking of the White Matter by Using Diffusion Tensor MR Imaging: Influence of the Number of Diffusion-Sensitizing Gradient Direction (확산텐서 MR 영상을 이용한 백질의 비등방성 측정 및 백질섬유 트래킹: 확산경사자장의 방향수가 미치는 영향)

  • Jun, Woo-Sun;Hong, Sung-Woo;Lee, Jong-Sea;Kim, Sung-Hyun;Kim, Jae-Hyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • Purpose : Recent development of diffusion tensor imaging enables the evaluation of the microstructural characteristics of the brain white matter. However, optimal imaging parameters for diffusion tensor imaging, particularly concerning the number of diffusion gradient direction, have not been studied thoroughly yet. The purpose of this study was to evaluate the influence of the number of diffusion gradient direction on the fiber tracking of the white matter. Materials and methods : 13 healthy volunteers (ten men and three women, mean age 30 years, age range 23-37 years) were included in this study. Diffusion tensor imaging was performed with different numbers of diffusion gradient direction as 6, 15, and 32, keeping the other imaging parameters constant. The imaging field ranged from 1 cm below the pons to 2-3 cm above the lateral ventricle, parallel to the anterior commissure-posterior commissure line. FA (fractional anisotropy) maps were created via image postprocessing, and then FA and its standard deviation were calculated in the genu and the splenium of the corpus callosum on each of FA maps. Fiber tracking of the corticospinal tract in the brain was performed and the number of the reconstructed fibers of the tract was measured. FA, standard deviation of FA and the number of the reconstructed fibers were compared statistically between the different diffusion gradient directions. Results : FA is not statistically significantly different between the different diffusion gradient directions. By increasing the number of diffusion gradient direction, standard deviation of FA decreased significantly, and the number of the reconstructed fibers increased significantly. Conclusion : The higher number of diffusion gradient direction provided better quality of fiber tracking.

  • PDF