• Title/Summary/Keyword: Image Function

Search Result 3,247, Processing Time 0.026 seconds

The Irradiated Lung Volume in Tangential Fields for the Treatment of a Breast (유방암의 접선 조사시 피폭 폐용적)

  • Oh Young Taek;Kim Juree;Kang Haejin;Sohn Jeong Hye;Kang Seung Hee;Chun Mison
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 1997
  • Purpose : Radiation pneumonitis is one of the complications caused by radiation therapy that includes a Portion of the lung tissue. The severity of radiation induced pulmonary dysfunction depends on the irradiated lung volume, total dose, dose rate and underlying Pulmonary function. It also depends on whether chemotherapy is done or not. The irradiated lung volume is the most important factor to predict the pulmonary dysfunction in breast cancer Patients following radiation therapy. There are some data that show the irradiated lung volume measured from CT scans as a part of treatment Planning with the tangential beams. But such data have not been reported in Korea. We planned to evaluate the irradiated lung volume quantitatively using CT scans for the breast tangential field and search for useful factors that could Predict the irradiated lung volume Materials and Methods : The lung volume was measured for 25 patients with breast cancer irradiated with tangential field from Jan.1995 to Aug.1996. Parameters that can predict the irradiated lung volume included; (1) the peruendicular distance from the Posterior tangential edge to the posterior part of the anterior chest wall at the center of the field (CLD) ; (2) the maximum perpendicular distance from the posterior tangential field edge to the posterior Part of the anterior chest wall (MLD) ; (3) the greatest perpendicular distance from the Posterior tangential edge to the posterior part of anterior chest wall on CT image at the center of the longitudinal field (GPD) ; (4) the length of the longitudinal field (L). The irradiated lung volume(RV), the entire both lung volume(EV) and the ipsilateral lung volume(IV) were measured using dose volume histogram. The relationship between the irradiated lung volume and predictors was evaluated by regression analysis. Results :The RV is 61-279cc (mean 170cc), the RV/EV is $2.9-13.0\%\;(mean\;5.8\%)$ and the RV/IV is $4.9-29.0\%\;(mean\;12.2\%)$. The CLD, the MLD and the GPD ave 1.9-3.3cm, 1.9-3.3cm and 1.4-3.1cm respectively. The significant relations between the irradiated lung volume such as RV. RV/EV, RV/IV and parameters such as CLD, MLD, GPO, L. $CLD\timesL,\;MLD\timesL\;and\;GPD\timesL$ are not found with little variances in parameters. The RV/IV of the left breast irradiation is significantly larger than that of the right but the RV/EVS do not show the differences. There is no symptomatic radiation pneumonitis at least during 6 months follow up. Conclusion : The significant relationship between the irradiated lung volume and predictors is not found with little variation on parameters. The irradiated lung volume in the tangential held is liss than $10\%$ of entire lung volume when CLO is less than 3cm. The RV/IV of the left tangential field is larger than that of the right but there was no significant differences in RV/EVS. Symptomatic radiation pneumonitis has not occurred during minimum 6 months follow up.

  • PDF

Distortion of the Dose Profile in a Three-dimensional Moving Phantom to Simulate Tumor Motion during Image-guided Radiosurgery (방사선수술에서 종양 움직임을 재현시킨 움직이는 팬텀을 이용하여 선량 분포의 왜곡에 대한 연구)

  • Kim, Mi-Sook;Ha, Seong-Hwan;Lee, Dong-Han;Ji, Young-Hoon;Yoo, Seong-Yul;Cho, Chul-Koo;Yang, Kwang-Mo;Yoo, Hyung-Jun;Seo, Young-Seok;Park, Chan-Il;Kim, Il-Han;Ye, Seong-Jun;Park, Jae-Hong;Kim, Kum-Bae
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.268-277
    • /
    • 2007
  • Purpose: Respiratory motion is a considerable inhibiting factor for precise treatment with stereotactic radiosurgery using the CyberKnife (CK). In this study, we developed a moving phantom to simulate three-dimensional breathing movement and investigated the distortion of dose profiles between the use of a moving phantom and a static phantom. Materials and Methods: The phantom consisted of four pieces of polyethylene; two sheets of Gafchromic film were inserted for dosimetry. Treatment was planned to deliver 30 Gy to virtual tumors of 20, 30, 40, and 50 mm diameters using 104 beams and a single center mode. A specially designed robot produced three-dimensional motion in the right-left, anterior-posterior, and craniocaudal directions of 5, 10 and 20 mm, respectively. Using the optical density of the films as a function of dose, the dose profiles of both static and moving phantoms were measured. Results: The prescribed isodose to cover the virtual tumors on the static phantom were 80% for 20 mm, 84% for 30 mm, 83% for 40 mm and 80% for 50 mm tumors. However, to compensate for the respiratory motion, the minimum isodose levels to cover the moving target were 70% for the $30{\sim}50$ mm diameter tumors and 60% for a 20 mm tumor. For the 20 mm tumor, the gaps between the isodose curves for the static and moving phantoms were 3.2, 3.3, 3.5 and 1.1 mm for the cranial, caudal, right, and left direction, respectively. In the case of the 30 mm tumor, the gaps were 3.9, 4.2, 2.8, 0 mm, respectively. In the case of the 40 mm tumor, the gaps were 4.0, 4.8, 1.1, and 0 mm, respectively. In the case of the 50 mm diameter tumor, the gaps were 3.9, 3.9, 0 and 0 mm, respectively. Conclusion: For a tumor of a 20 mm diameter, the 80% isodose curve can be planned to cover the tumor; a 60% isodose curve will have to be chosen due to the tumor motion. The gap between these 80% and 60% curves is 5 mm. In tumors with diameters of 30, 40 and 50 mm, the whole tumor will be covered if an isodose curve of about 70% is selected, equivalent of placing a respiratory margin of below 5 mm. It was confirmed that during CK treatment for a moving tumor, the range of distortion produced by motion was less than the range of motion itself.

Internal Changes and Countermeasure for Performance Improvement by Separation of Prescribing and Dispensing Practice in Health Center (의약분업(醫藥分業) 실시(實施)에 따른 보건소(保健所)의 내부변화(內部變化)와 업무개선방안(業務改善方案))

  • Jeong, Myeong-Sun;Kam, Sin;Kim, Tae-Woong
    • Journal of agricultural medicine and community health
    • /
    • v.26 no.1
    • /
    • pp.19-35
    • /
    • 2001
  • This study was conducted to investigate the internal changes and the countermeasure for performance improvement by Separation of Prescribing and Dispensing Practice (SPDP) in Health Center. Data were collected from two sources: Performance report before and after SPDP of 25 Health Centers in Kyongsangbuk-do and 6 Health Centers in Daegu-City and self-administerd questionnaire survey of 221 officials at health center. The results of this study were summarized as follows: Twenty-four health centers(77.4%) of 31 health centers took convenience measures for medical treatment of citizens and convenience measures were getting map of pharmacy, improvement of health center interior, introduction of order communication system in order. After the SPDP in health centers, 19.4% of health centers increased doctors and 25.8% decreased pharmacists. 58.1% of health centers showed that number of medical treatments were decreased. 96.4%, 80.6% 80.6% 96.7% of health centers showed that number of prescriptions, total medical treatment expenses, amounts paid by the insureds and the expenses to purchase drugs, respectively, were decreased. More than fifty percent(54.2%) of health centers responded that the relative importance of health works increased compared to medical treatments after the SPDP, and number of patients decreased compared to those in before the SPDP. And there was a drastic reduction in number of prescriptions, total medical treatment expenses, amounts paid by insureds, the expenses to purchase drugs after the SPDP. Above fifty percent(57.6%) of officers at health center responded that the function of medical treatment should be reduced after the SPDP. Fields requested improvement in health centers were 'development of heath works contents'(62.4%), 'rearrangement of health center personnel'(51.6%), 'priority setting for health works'(48.4%), 'restructuring the organization'(36.2%), 'quality impro­vement for medical services'(32.1%), 'replaning the budgets'(23.1%) in order. And to better the image of health centers, health center officers replied that 'health information management'(60.7%), 'public relations for health center'(15.8%), 'kindness of health center officers'(15.3%) were necessary in order. Health center officers suggested that 'vaccination program', 'health promotion', 'maternal and children health', 'communicable disease management', 'community health planning' were relatively important works, in order, performed by health center after SPDP. In the future, medical services in health centers should be cut down with a momentum of the SPDP so that health centers might reestablish their functions and roles as public health organizations, but quality of medical services must be improved. Also health centers should pay attention to residents for improving health through 'vaccination program', 'health promotion', 'mother-children health', 'acute and chronic communicable disease management', 'community health planning', 'oral health', 'chronic degenerative disease management', etc. And there should be a differentiation of relative importance between health promotion services and medical treatment services by character of areas(metropolitan, city, county).

  • PDF

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

Evaluation of usefulness of the Gated Cone-beam CT in Respiratory Gated SBRT (호흡동조 정위체부방사선치료에서 Gated Cone-beam CT의 유용성 평가)

  • Hong sung yun;Lee chung hwan;Park je wan;Song heung kwon;Yoon in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.61-72
    • /
    • 2022
  • Purpose: Conventional CBCT(Cone-beam Computed-tomography) caused an error in the target volume due to organ movement in the area affected by respiratory movement. The purpose of this paper is to evaluate the usefulness of accuracy and time spent using the Gated CBCT function, which reduces errors when performing RGRT(respiratory gated radiation therapy), and to examine the appropriateness of phase. Materials and methods: To evaluate the usefulness of Gated CBCT, the QUASARTM respiratory motion phantom was used in the Truebeam STxTM. Using lead marker inserts, Gated CBCT was scaned 5 times for every 20~80% phase, 30~70% phase, and 40~60% phase to measure the blurring length of the lead marker, and the distance the lead marker moves from the top phase to the end of the phase was measured 5 times. Using Cedar Solid Tumor Inserts, 4DCT was scanned for every phase, 20-80%, 30-70%, and 40-60%, and the target volume was contoured and the length was measured five times in the axial direction (S-I direction). Result: In Gated CBCT scaned using lead marker inserts, the axial moving distance of the lead marker on average was measured to be 4.46cm in the full phase, 3.11cm in the 20-80% phase, 1.94cm in the 30-70% phase, 0.90cm in the 40-60% phase. In Fluoroscopy, the axial moving distance of the lead marker on average was 4.38cm and the distance on average from the top phase to the beam off phase was 3.342cm in the 20-80% phase, 3.342cm in the 30-70% phase, and 0.84cm in the 40-60% phase. Comparing the results, the difference in the full phase was 0.08cm, the 20~80% phase was 0.23cm, the 30~70% phase was 0.10cm, and the 40~60% phase was 0.07cm. The axial lengths of ITV(Internal Target Volume) and PTV(Planning Target Volume) contoured by 4DCT taken using cedar solid tumor inserts were measured to be 6.40cm and 7.40cm in the full phase, 4.96cm and 5.96cm in the 20~80% phase, 4.42cm and 5.42cm in the 30~70% phase, and 2.95cm and 3.95cm in the 40~60% phase. In the Gated CBCT, the axial lengths on average was measured to be 6.35 cm in the full phase, 5.25 cm in the 20-80% phase, 4.04 cm in the 30-70% phase, and 3.08 cm in the 40-60% phase. Comparing the results, it was confirmed that the error was within ±8.5% of ITV Conclusion: Conventional CBCT had a problem that errors occurred due to organ movement in areas affected by respiratory movement, but through this study, obtained an image similar to the target volume of the setting phase using Gated CBCT and verified its usefulness. However, as the setting phase decreases, the scan time was increases. Therefore, considering the scan time and the error in setting phase, It is recommended to apply it to patients with respiratory coordinated stereotactic radiation therapy using a wide phase of 30-70% or more.

Conjunction of Consciousness and The Unconscious·Individuation and Circumambulation of The Psyche: Focusing on the Hexagram Bi, Pi (比) and Hexagram Gon, Kun (坤) (의식과 무의식의 통합 및 개성화와 정신의 순환: 수지비괘(일양오음괘)와 중지곤괘를 중심으로)

  • Hyeon Gu Lee
    • Sim-seong Yeon-gu
    • /
    • v.38 no.1
    • /
    • pp.1-44
    • /
    • 2023
  • Hexagram Bi (比 ䷇ 8) is one of the hexagrams comprised of one-unbroken line and five-broken lines. The hexagrams of one-unbroken and five-broken lines symbolize the relationship and dynamics between one yang-consciousness and the five-yin unconsciousness. The hexagram of one-unbroken line and five-broken lines has six different images depending on the position of the one unbroken line from the beginning line to the top line. In terms of psychology, this means that the position change of one yang line in relation to five yin lines may symbolize the function of consciousness which clarifies and determines the content of the psyche. In addition, the flow of psychic energy can be examined through the process of one unbroken line's movement. In other words, the psychic contents of the beginning line of hexagram Bok (復 ䷗ 24), which is the beginning of the hexagram of one-unbroken line and five-broken lines, proceed sequentially, and then arrive at the process of the last sixth, hexagram Bak (剝 ䷖ 23) through the fifth, the hexagram Bi (8). That is, it can be said that the content of the hexagram and the line determined according to the position of one unbroken line show a certain psychic flow. As a result, the first hexagram Bok (復 ䷗ 24), after recovering and starting newly, means the beginning of consciousness. After that the process of proceeding with the second, third, and fourth lines represents the flow of consciousness. And in the fifth place, the fifth line of hexagram Bi, it reaches its peak and is placed in the optimal state of consciousness because of its right and centered position at this hexagram Bi. Like nature, the psyche gradually enters the path of decline from the highest state, which leads to the last sixth, the top line of hexagram Bak. However, the top line of the hexagram Bak, where everything falls off, contains the content of starting again in its top line. It is the beginning line of hexagram Bok to inherit this. This means the circumambulation of the psyche that changes from a psychologically difficult state of depression to a stage of recovery. There is a stage that must be passed in this circulation process, and that is the hexagram Gon (坤 ䷁ 2). October(tenth month)'s hexagram Gon is placed between hexagram Bak, the ninth month of the lunar calendar, and hexagram Bok, the eleventh month of the lunar calendar. This represents that the flow of recovery must go through a maternal process of hexagram Gon. The retreat to the psychological uterus is inevitable in regenerating the psyche. This process flows from the hexagram Bak and through hexagram Gon to the hexagram Bok. At this situation the hexagram Gon acts the absolutely necessary role. In addition, the main body of the hexagrams of one-unbroken and five-broken lines, including the Bi hexagram, is also the Gon hexagram composed of six-broken lines. In other words, all six hexagrams of one-unbroken and five-broken lines have a certain relationship with the Gon hexagram, and it would be meaningful to look at the correlation between the unbroken lines of the hexagrams of one-unbroken and five-broken lines and the corresponding broken lines of the hexagram Gon. This can be said to be the dynamics of the maternal unconscious connected to the state of consciousness in six forms. Therefore, each hexagram of one-unbroken and five-broken lines symbolizes the expression of the integration the mother archetype with the consciousness. Revealing this well is the meaning of the hexagram of one-unbroken and five-broken lines. Its hexagram image consists of a combination of Gon (☷), which symbolizes the mother, and the thunder (☳) the eldest son, the water (☵) the middle son and the mountain (☶) the third son. As a result, the hexagram Bok (復 ䷗ 24), Sa (師 ䷆ 7), Gyeom (謙 ䷠ 15), Ye (豫 ䷏ 16), Bi (比 ䷇ 8) and Bak (剝 ䷖ 23) are sequentially created in the order of the unbroken line. This is symbolically the evolutionary process of consciousness. In this way, the hexagrams of one-unbroken and five-broken lines, which mean the conjunction of mother and son, represent the advancing relationship between the maternal unconscious and consciousness. In addition, the relationship with the mother according to the position of the son is related to the dynamics of mother archetype to the attitude of consciousness. The psychological meaning can be deduced from the flow of six lines of hexagrams of one-unbroken and five-broken lines. And the state in which the activation of the consciousness is at its peak is the fifth line of the hexagram Bi, and comparing it with the contents of the corresponding fifth line of hexagram Gon not only can find the state and meaning of the conjunction of consciousness and the maternal unconscious, but the entire flow can be compared to the individuation process.