• Title/Summary/Keyword: Image Detector

Search Result 922, Processing Time 0.026 seconds

A Study on Chest X-ray Using Ancillary Device for Child Radiography (방사선촬영 보조기구를 이용한 어린이 흉부 엑스선 검사에 관한 연구)

  • Rhee, Do-byung;Lee, Somi;Choi, Hyunwoo;Kim, Jong-ki;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.48-54
    • /
    • 2018
  • In this study, We developed a Ancillary device for child radiography for X-ray of children under 5 years old and verified its effectiveness. Chest X-rays of children younger than 5 years of age were performed by Supine method at the position of Table detector, Short - Source to Image Receptor Distance(SID). Existing Supine and Short -SID imaging methods cause many problems, such as errors in image reading and excessive radiation exposure dose to patients, but the use of an Ancillary device for child radiography(ADCR) solves these problems. A total of 160 children were divided into the Upright group using ADCR and Supine group without ADCR. The chest X-ray image was visually evaluated by two radiologists with reference to the European Commission's List of Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The total score of the qualitative evaluation was 5.15% higher in the chest upright method using ADCR than in the chest supine method without ADCR, and the chest upright method score was higher than that of the chest supine method in items 1 to 7. whether infants have deep inspiration or not, 4.87% higher for item 1, whether infants rotate or not and the degree of tilting, 0% higher for the item 2, the reproduction of image from just above apices of lungs to T12/L1, 0% for the item 3, reproduction of the vascular pattern in central 2/3 of the lungs, 6.92% higher for the item 4, reproduction of the trachea and the proximal bronchi, 12.9% higher for the item 5, visually sharp reproduction of the diaphragm and costo-phrenic angles, 10% higher for the item 6, reproduction of the spine and paraspinal structures and visualisation of the retrocardiac lung and the mediastinum, and 3.65% higher for the item 7. Items 2 and 3 showed no statistically significant differences(P > 0.05), and items 1, 4, 5, 6, and 7 showed statistically significant differences(P < 0.05). In conclusion, Upright method using ADCR in pediatric chest X-ray is considered as a good alternative to existing Supine method.

Nondestructive Measurement of the Coating Thickness in the Simulated TRISO-Coated Fuel Particle Using Micro-Focus X-ray Radiography (마이크로포커스 X-선 투과 영상을 이용한 모의 TRISO 핵연료 입자 코팅 층 두께 비파괴 측정)

  • Kim, Woong-Ki;Lee, Young-Woo;Park, Ji-Yeon;Park, Jung-Byung;Ra, Sung-Woong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.69-76
    • /
    • 2006
  • TRISO(tri-isotropic)-coated fuel particle technology is utilized owing to its higher stability at a high temperature and Its efficient retention capability for fission products In the HTGR(high temperature gas-reeled reactor). The typical spherical TRISO fuel panicle with a diameter of about 1mm is composed of a nuclear fuel kernel and outer coating layers. The outer coating layers consist of a buffer PyC(pyrolytic carbon) layer, Inner PyC(1-PyC) layer, SiC layer, and outer PyC(O-PyC) layer Most of the Inspection Items for the TRTSO-coated fuel particle depend on destructive methods. The coating thickness of the TRISO fuel particle can be nondestructively measured by the X-ray radiography without generating radioactive wastel. In this study, the coaling thickness for the simulated TRISO-coated fuel particle with $ZrO_2$ kernel Instead of $%UO_2$ kernel was measured by using micro-focus X-ray radiography with micro-focus X-ray generator and flat panel detector The radiographic image was also enhanced by image processing technique to acquire clear boundary lines between coating layers. The coaling thickness wat effectively measured by applying the micro-focus X-ray radiography The inspection process for the TRISO-coated fuel particles will be improved by the developed micro-focus X-ray radiography and digital image processing technology.

Evaluation of Contrast-detail Characteristics of an A-Se Based Digital X-ray Imaging System (A-Se 기반 디지털 X-선 영상장치의 Contrast-detail 특성 평가)

  • Hyun, Hye-Kyung;Park, So-Hyun;Kim, Keun-Young;Cho, Hee-Moon;Cho, Hyo-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.11-16
    • /
    • 2007
  • In this study, we have performed contrast-detail analysis for an amorphous selenium(a-Se) based digital X-ray imaging system by using a contrast-detail phantom(CDRAD 2.0) to test its low contrast performance. The X-ray imaging system utilizes an 500-mm-thick a-Se semiconductor X-ray absorber coated over an amorphous silicon(a-Si) TFT(thin-film transistor) detector matrix with a $139mm{\times}139mm$ pixel size and a $46.7cm{\times}46.7cm$ active area. In the measurement of contrast-detail curves we first acquired X-ray images of the CDRAD 2.0 phantom at given test conditions(i.e., 40, 50, 60, 70, 80 kVp, and 16 mA.s), and then evaluated the contrast-detail characteristics of the imaging system from each phantom image by using an image quality factor called the image-quality-figure-inverse(IQFinv). The IQFinv values for the imaging system gradually improved with the photon fluence, indicating the improvement of image visibility: 24.4, 35.3, 39.2, 41.5, and 43.4 at photon fluences of $1.8{\times}105$, $5.9{\times}105$, $11.3{\times}105$, $19.4{\times}105$, and $29.4{\times}105$ photons/$mm^2$, respectively.

  • PDF

Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol (흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교)

  • Lee, Won-Jeong;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • The purpose of this study was to compare radiation dose and image quality between low-dose (LDP) and standard-dose protocol (SDP). LDP (120 kVp, 30 mAs, 2-mm thickness) and SDP (120 kVp, 180 mAs, 1.2-mm thickness) images obtained from 61 subjects were retrospectively evaluated at level of carina bifurcation, using multi-detector CT (Brilliance 16, Philips Medical Systems). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated at ascending aorta and infraspinatus muscle, from CT number and back-ground noise. Radiation dose from two protocols measured at 5-point using acrylic-phantom, and CT number and noise measured at 4-point using water-phantom. All statistical analysis were performed using SPSS 19.0 program. LDP images showed significantly more noise and a significantly lower SNR and CNR than did SDP images at ascending aorta and infraspinatus muscle. Noise, SNR and CNR were significantly correlated with body mass index (p<0.001). Radiation dose, SNR and CNR from phantom were significant differences between two protocols. LDP showed a significant reduction of radiation dose with a significant change in SNR and CNR compared with SDP. Therefore, exposure dose on LDP in clinical applications needs resetting highly more considering image quality.

Radiographic Study of Cobey Method and Modified Cobey Method (Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구)

  • Go, Yu-Rim;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.167-173
    • /
    • 2019
  • The Cobey method and the modified Cobey method are most commonly used in clinical practice. Therefore, the purpose of this study was to investigate the radiological differences between Cobey and modified Cobey and provide radiographic information about changes of hindfoot image with X-ray entrance center and tube angle change in modified Cobey. This study was performed on foot and ankle phantom. First, for image comparison of Cobey and modified Cobey, the images obtained by applying the same X-ray entrance center to the ankle joint were compared and analyzed. Second, in the modified Cobey, the X-ray entrance center is set as ankle joint and lateral malleolus. The X-ray tube angle was varied from $10^{\circ}$ to $40^{\circ}$ at $5^{\circ}$ intervals for each X-ray entrance center. The images obtained by varying the X-ray tube angle from $10^{\circ}$ to $40^{\circ}$ at intervals of $5^{\circ}$ for each X-ray entrance center were compared and analyzed. The irradiation conditions were the same with 110 kVp, 200 mA, 10 ms, and 110 cm of source - image receptor distance (SID). Image evaluation was performed by two radiologists. Measurements were made on the lateral point, middle point, and calcaneus width based on a hypothetical line parallel to the calcaneal tuberosity. Data were analyzed by using descriptive statistics as the mean of the distance to each measurement location. The modified Cobey was longer than the Cobey by an average of 3 to 4 mm lateral and medial points, and the calcaneus width was similar (ICC = 0.939). In modified Cobey method, when the X-ray entrance center is ankle joint, the lateral point is about 3 mm and the medial point is about 4.3 mm longer than lateral malleolus. Also, when the X-ray tube angle is more than $20^{\circ}$, the degree of distortion is large. The ICCs for the lateral, medial point, and calcaneus width were 0.998, 0.961, and 0.997, respectively, as the X-ray entrance center and tube angle were changed. There was no significant difference between Modified Cobey and Cobey. Modified Cobey showed no need to compensate the $20^{\circ}$ detector angle of the Cobey. In addition, we suggest that tube angle should be limited within $20^{\circ}$ when modified Cobey is performed.

Face Tracking System Using Updated Skin Color (업데이트된 피부색을 이용한 얼굴 추적 시스템)

  • Ahn, Kyung-Hee;Kim, Jong-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.5
    • /
    • pp.610-619
    • /
    • 2015
  • *In this paper, we propose a real-time face tracking system using an adaptive face detector and a tracking algorithm. An image is divided into the regions of background and face candidate by a real-time updated skin color identifying system in order to accurately detect facial features. The facial characteristics are extracted using the five types of simple Haar-like features. The extracted features are reinterpreted by Principal Component Analysis (PCA), and the interpreted principal components are processed by Support Vector Machine (SVM) that classifies into facial and non-facial areas. The movement of the face is traced by Kalman filter and Mean shift, which use the static information of the detected faces and the differences between previous and current frames. The proposed system identifies the initial skin color and updates it through a real-time color detecting system. A similar background color can be removed by updating the skin color. Also, the performance increases up to 20% when the background color is reduced in comparison to extracting features from the entire region. The increased detection rate and speed are acquired by the usage of Kalman filter and Mean shift.

Sensing changes in tumor during boron neutron capture therapy using PET with a collimator: Simulation study

  • Yang, Hye Jeong;Yoon, Do-Kun;Suh, Tae Suk
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2072-2077
    • /
    • 2020
  • The purpose of this study was to demonstrate the feasibility of sensing changes in a tumor during boron neutron capture therapy (BNCT) using a Monte Carlo simulation tool. In the simulation, an epi-thermal neutron source and a water phantom including boron uptake regions (BURs) were simulated. Moreover, this simulation also included a detector for positron emission tomography (PET) scanning and an adaptively-designed collimator (ADC) for PET. After the PET scanning of the water phantom, including the 511 keV source in the BUR, the ADC was positioned in the PET's gantry. Single prompt gamma rays were collected through the ADC during neutron irradiation. Then, single prompt gamma ray-based tomography images of different sized tumors were acquired by a four-step process. Both the signal-to-noise ratio (SNR) and tumor size were analyzed from each step image. From this analysis, we identified a decreasing trend of both the SNR and signal intensity as the tumor size decreased, which was confirmed in all images. In conclusion, we confirmed the feasibility of sensing changes in a tumor during BNCT using PET and an ADC through Monte Carlo simulation.

An Efficient Pedestrian Detection Approach Using a Novel Split Function of Hough Forests

  • Do, Trung Dung;Vu, Thi Ly;Nguyen, Van Huan;Kim, Hakil;Lee, Chongho
    • Journal of Computing Science and Engineering
    • /
    • v.8 no.4
    • /
    • pp.207-214
    • /
    • 2014
  • In pedestrian detection applications, one of the most popular frameworks that has received extensive attention in recent years is widely known as a 'Hough forest' (HF). To improve the accuracy of detection, this paper proposes a novel split function to exploit the statistical information of the training set stored in each node during the construction of the forest. The proposed split function makes the trees in the forest more robust to noise and illumination changes. Moreover, the errors of each stage in the training forest are minimized using a global loss function to support trees to track harder training samples. After having the forest trained, the standard HF detector follows up to search for and localize instances in the image. Experimental results showed that the detection performance of the proposed framework was improved significantly with respect to the standard HF and alternating decision forest (ADF) in some public datasets.

THE CURRENT STATUS OF THE AKARI MID-INFRARED ALL-SKY DIFFUSE MAPS

  • Amatsutsu, Tomoya;Ishihara, Daisuke;Kondo, Toru;Kaneda, Hidehiro;Oyabu, Shinki;Yamagishi, Mitsuyoshi;Nakamichi, Keichiro;Sano, Hidetoshi;Onaka, Takashi
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.25-27
    • /
    • 2017
  • We are creating all-sky diffuse maps from the AKARI mid-infrared survey data with the two photometric bands centered at wavelengths of 9 and $18{\mu}m$. The AKARI mid-infrared diffuse maps achieve higher spatial resolution and higher sensitivity than the IRAS maps. In particular, the $9{\mu}m$ data are unique resources as an all-sky tracer of the emission of polycyclic aromatic hydrocarbons (PAHs). However, the original data suffer many artifacts. Thus, we have been developing correction methods. Among them, we have recently improved correction methods for the non-linearity and the reset anomaly of the detector response. These corrections successfully reduce the artifact level down to $0.1MJy\;sr^{-1}$ on average, which is essential for discussion on faint extended emission (e.g., the Galactic PAH emission). We have also made progress in the subtraction of the scattered light caused in the camera optics. We plan to release the improved diffuse maps to the public within a year.

DEVELOPMENT OF 3-D POSITION DETECTING TECHNIQUE BY PAN/TILT

  • Son, J.R.;Kang, C.H.;Han, K.S.;Jung, S.R.;Kwon, K.Y.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.698-706
    • /
    • 2000
  • It is very difficult to mechanize tomato harvesting because identifying a tomato partly covered with leaves and stalks is not easy. This research was conducted to develop tomato harvesting robot which can identify a target tomato, determine its three dimensional position, and harvest it in a limited time. Followings were major findings in this study. The first visual system of the harvesting robot was composed of two CCD cameras, however, this could not detect tomatoes which are not seen on the view finder of the camera especially those partly covered by leaves or stalks. The second visual device, combined with two CCD cameras and pan/tilt procedures was designed to minimize the positioning errors within ${\pm}10mm$, but this is still not enough to detect tomatoes partly covered with leaves etc. Finally, laser distance detector was added to the visual system that could reduce the position detecting errors within 10mm in X-Y direction and 5mm in Z direction for the partly covered tomatoes.

  • PDF