• 제목/요약/키워드: Image Detector

검색결과 922건 처리시간 0.035초

A method for underwater image analysis using bi-dimensional empirical mode decomposition technique

  • Liu, Bo;Lin, Yan
    • Ocean Systems Engineering
    • /
    • 제2권2호
    • /
    • pp.137-145
    • /
    • 2012
  • Recent developments in underwater image recognition methods have received large attention by the ocean engineering researchers. In this paper, an improved bi-dimensional empirical mode decomposition (BEMD) approach is employed to decompose the given underwater image into intrinsic mode functions (IMFs) and residual. We developed a joint algorithm based on BEMD and Canny operator to extract multi-pixel edge features at multiple scales in IMFs sub-images. So the multiple pixel edge extraction is an advantage of our approach; the other contribution of this method is the realization of the bi-dimensional sifting process, which is realized utilizing regional-based operators to detect local extreme points and constructing radial basis function for curve surface interpolation. The performance of the multi-pixel edge extraction algorithm for processing underwater image is demonstrated in the contrast experiment with both the proposed method and the phase congruency edge detection.

상관도 비교를 이용한 웨이블릿 기반 워터마킹 (Wavelet-based Watermarking using Correlation Comparison)

  • Lee, Hyun-Suk;Vivi Oktavia;Lee, Won-Hyung
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.217-220
    • /
    • 2003
  • This paper presents a wavelet-based digital watermarking scheme for color images. We insert watermarks in the DWI domain using spread-spectrum correlation-based watermarking in luminance component of the color image. The watermark, two pseudorandom patterns, is inserted by modifying the wavelet coefficients at subband HL2, LH2, HH2 according to message bits. To detect watermark, we calculate the correlation between the watermarked image and pseudorandom patterns. As compared with correlations, the watermark detector determines embedding message. Experimental results show that the scheme is not only invisible but also robust to various attacks such as JPEG compression, noise addition and so on.

  • PDF

이진 위상 홀로그램을 이용한 간섭성 영상 암호화 및 복원 (Interferometric Image Encryption and Decryption using Binary Phase Hologram)

  • 김종윤;김정우
    • 한국콘텐츠학회논문지
    • /
    • 제2권3호
    • /
    • pp.80-86
    • /
    • 2002
  • 본 논문에서는 이진 위상 홀로그램과 간섭원리를 이용하여 기존의 광 암호화 방법보다 암호영상 마스크를 제작 하기는 쉽고 암호 해독은 어려운 영상 암호 기법과 복원 및 인증 시스템을 제안하였다. 제안한 암호화 방법은 원영상의 홀로그램을 암호화하므로 원영상을 이중으로 암호화한다. 또한 암호화된 위상패턴을 위상카드로 제작할 경우 광세기 검출기로 볼 수 없을 뿐만 아니라 복제할 수도 없어서 개인 정보보호 및 인증시스템에 매우 유용하게 사 용될 수 있다.

  • PDF

회전 운동 잔여 효과의 확산 현상: 전역적 운동 탐지기의 순응에 대한 증거 (Spreading of motion aftereffect for rotational motion: Evidence of adaptation of global motion detector)

  • 감기택
    • 인지과학
    • /
    • 제16권1호
    • /
    • pp.17-27
    • /
    • 2005
  • 움직이는 패턴을 오랫동안 본 후에 정지된 패턴을 보면. 정지된 패턴이 운동 패턴의 반대 방향으로 움직이는 것으로 지각되는 운동 잔여 효과(motion aftereffect: MAE)가 발생된다. 이 현상에 대한 고전적인 설명과는 달리 복잡운동의 MAE는 운동 순응이 발생되지 않은 영역에까지 확산된다. 본 연구에서는 시각 정보 처리 과정에서 MAE의 확산 현상이 발생되는 신경기제의 상대적인 위치를 알아보기 위해서 하모닉 나선형 패턴을 운동 순응 자극으로 사용하여 고리모양의 창에 제시한 후, 순응이 발생된 고리영역과 순응이 발생되지 않은 안쪽 영역 모두에서 MAE를 측정하였다. 순응자극과 동일한 영상과 거울상을 각각 검사자극으로 사용하여 MAE를 측정하고 두 조건에서 발견된 MAE를 비교하였다. 하모닉 나선형 자극의 특징은 동일 영역에 제시된 원영상과 거울상의 윤곽 방위의 차이가 90도라는 점이다. 이러한 특징에 의해 거울상의 경우 국소 운동 정보를 추출하는 탐지기 수준에서는 순응효과를 기대하기 어렵다. 실험 결과 순응된 영역에서의 MAE 지속시간은 동일상 조건이 거울상 조건보다 더 길게 나타났지만, 운동 순응이 없었던 영역(운동 잔여효과의 확산 영역)에서는 두 조건간 유의한 차이가 발생되지 않았다. 이러한 결과는 복잡운동(complex motion)의 MAE 화산은 국소 운동 정보가 추출되는 V1과 같은 초기 단계에 있는 신경세포의 순응이 아니라 복잡 운동이 처리되는 MSTd 에 있는 신경세포들의 순응에 의해서 발생됨을 시사한다.

  • PDF

광센서 크기에 따른 섬광 픽셀 배열의 최대화 연구 (A Study on the Maximization of Scintillation Pixel Array According to the Size of the Photosensor)

  • 이승재
    • 한국방사선학회논문지
    • /
    • 제16권2호
    • /
    • pp.157-162
    • /
    • 2022
  • 전임상용 양전자방출단층촬영기기는 인체에 비해 매우 작은 소동물을 대상으로 촬영이 이루어지므로, 우수한 공간분해능을 지닌 검출기가 필요하다. 이를 위해 작은 섬광 픽셀을 사용한 검출기를 사용하여 시스템을 구성하였다. 현재 개발되어 사용되는 광센서의 크기는 한정되어 있으므로, 이에 맞는 최소한의 섬광 픽셀과 최대의 배열로 구성할 경우 우수한 공간분해능을 얻을 수 있다. 본 연구에서는 광센서의 크기를 고정하고, 이에 맞는 다양한 섬광 픽셀의 배열을 구성하여 평면 영상에서 겹침이 발생하지 않고, 모든 섬광 픽셀들이 구분이 되는 최대의 섬광 픽셀 배열을 찾고자 한다. 이를 위해 섬광체와 광센서로 이루어진 검출기 모듈의 시뮬레이션이 가능한 DETECT2000을 사용하였다. 3 mm × 3 mm 픽셀이 4 × 4 배열로 이루어진 광센서를 사용하였으며, 섬광 픽셀 배열은 8 × 8에서부터 13 × 13까지 구성하여 시뮬레이션을 수행하였다. 광센서 픽셀에서 획득된 데이터를 통해 평면 영상을 구성하였으며, 평면 영상과 프로파일을 통해 영상의 겹침이 발생하지 않는 최대의 섬광 픽셀 배열을 찾았다. 그 결과 평면 영상에서 서로 겹침이 발생하지 않고 모든 섬광 픽셀들이 영상화되는 섬광 픽셀 배열의 크기는 11 × 11이었다.

An adaptive method of multi-scale edge detection for underwater image

  • Bo, Liu
    • Ocean Systems Engineering
    • /
    • 제6권3호
    • /
    • pp.217-231
    • /
    • 2016
  • This paper presents a new approach for underwater image analysis using the bi-dimensional empirical mode decomposition (BEMD) technique and the phase congruency information. The BEMD algorithm, fully unsupervised, it is mainly applied to texture extraction and image filtering, which are widely recognized as a difficult and challenging machine vision problem. The phase information is the very stability feature of image. Recent developments in analysis methods on the phase congruency information have received large attention by the image researchers. In this paper, the proposed method is called the EP model that inherits the advantages of the first two algorithms, so this model is suitable for processing underwater image. Moreover, the receiver operating characteristic (ROC) curve is presented in this paper to solve the problem that the threshold is greatly affected by personal experience when underwater image edge detection is performed using the EP model. The EP images are computed using combinations of the Canny detector parameters, and the binaryzation image results are generated accordingly. The ideal EP edge feature extractive maps are estimated using correspondence threshold which is optimized by ROC analysis. The experimental results show that the proposed algorithm is able to avoid the operation error caused by manual setting of the detection threshold, and to adaptively set the image feature detection threshold. The proposed method has been proved to be accuracy and effectiveness by the underwater image processing examples.

SIFT를 이용한 내시경 영상에서의 특징점 추출 (Feature Extraction for Endoscopic Image by using the Scale Invariant Feature Transform(SIFT))

  • 오장석;김호철;김형률;구자민;김민기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.6-8
    • /
    • 2005
  • Study that uses geometrical information in computer vision is lively. Problem that should be preceded is matching problem before studying. Feature point should be extracted for well matching. There are a lot of methods that extract feature point from former days are studied. Because problem does not exist algorithm that is applied for all images, it is a hot water. Specially, it is not easy to find feature point in endoscope image. The big problem can not decide easily a point that is predicted feature point as can know even if see endoscope image as eyes. Also, accuracy of matching problem can be decided after number of feature points is enough and also distributed on whole image. In this paper studied algorithm that can apply to endoscope image. SIFT method displayed excellent performance when compared with alternative way (Affine invariant point detector etc.) in general image but SIFT parameter that used in general image can't apply to endoscope image. The gual of this paper is abstraction of feature point on endoscope image that controlled by contrast threshold and curvature threshold among the parameters for applying SIFT method on endoscope image. Studied about method that feature points can have good distribution and control number of feature point than traditional alternative way by controlling the parameters on experiment result.

  • PDF

MDCT 장치의 z-축 기하학적 선량효율에 관한 연구 (Research of z-axis geometric dose efficiency in multi-detector computed tomography)

  • 김유현;김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.167-175
    • /
    • 2006
  • 최근의 나선형 CT와 MDCT는 기존의 고식적 CT보다 X-선 조사시의 겹침 현상과 영상 재구성에 있어서의 보간삽입처리로 인해 보다 높은 선량을 환자에게 주게 되었다. MDCT와 나선형 CT장치가 보다 많은 의학적 정보를 제공하는 것에도 불구하고 환자가 받는 방사선 노출은 기존의 고식적 CT검사에 비해 $2{\sim}4$배 정도로 증가되고 있는 실정이므로, 그 잠재적 위험성을 아무리 강조해도 지나침이 없다. CT장치에서의 보다 많은 X-선에 관련된 자료들, 특히 선량효율적 디자인이나 X-선 조절 소프트웨어에 대한 자료들이 필요하다. 왜냐하면 CT장치의 디자인 요소는 임상적 진단에 있어서 환자선량을 성공적으로 줄일 수 있는 중요한 요소이기 때문이다. 이에 본 연구에서는 최근 급격히 확산되어 사용되고 있는 여러 단계의 MDCT의 z-축 선량효율을 측정하여 SDCT와 비교하였다. 그리고 MDCT에서 스캔 시 채택하는 focal spot size와 beam collimation, 검출기 조합 등을 비롯한 파라메터들의 변화에 따른 z-축 선량효율을 파악하여 다음과 같은 결과를 얻었다. 1. SDCT가 z-축 기하학적 선량효율이 가장 높았고, 4 슬라이스 MDCT가 가장 낮았다. MDCT 중에서는 small beam collimation 적용 시 64 MDCT가 기하학적 선량효율이 가장 높았고 16, 8, 4 슬라이스 MDCT 순이었으며, large beam collimation 적용 시에는 small focal spot에서는 8 MDCT가, large focal spot에서는 16 MDCT가 가장 높았다. 2. MDCT의 경우 large focal spot에 비해 small focal spot의 z-축 기하학적 선량효율이 최저 0.67%에서 최대 13.62%의 범위에서 높았다. 3. MDCT의 경우 small beam collimation에 비해 large beam collimation의 z-축 기하학적 선량효율이 $3.13{\sim}51.52%$의 범위에서 높았다. 4. 동일한 focal spot size와 beam collimation을 채택한 상태에서 detector combination 차이에 따른 z-축 기하학적 선량효율은 4 슬라이스 MDCT의 모든 경우와 8 슬라이스 MDCT의 large beam collimation에서 일정하였다. 하지만 8 슬라이스 MDCT의 small beam collimation과 16 슬라이스 MDCT에서는 z-축 기하학적 선량효율이 차이를 보였으며 변화의 일률성은 없었다. 5. 동일한 스캔 파라메터를 적용시 나선형 스캔과 고식적 스캔 모드의 z-축 기하학적 선량효율은 동일하였으며, pitch를 변화시키거나 영상재구성 시 슬라이스 두께와 간격을 변화시켜도 z-축 기하학적 선량효율은 변화가 없었다. 결론적으로, CT검사 시 환자가 받는 X-선 피폭선량을 줄이기 위해 연구자는 CT장치의 선량효율에 대해 각별히 주의하여야 하며, Z-축 선량효율성을 높이는 동시에 최적의 임상적 정보를 보존할 수 있는 스캔 파라메터를 선택하여야 한다.

  • PDF

골반강 내 방사선 치료 환자에서 Electronic Portal Imaging Device(EPID)를 이용한 Portal Image의 유용성에 관한 연구 (Evaluation of Usefulness of Portal Image Using Electronic Portal Imaging Device (EPID) in the Patients Who Received Pelvic Radiation Therapy)

  • 김우철;박원;김현정;박성용;조영갑;노준규;서창옥;김귀언
    • Radiation Oncology Journal
    • /
    • 제16권4호
    • /
    • pp.497-504
    • /
    • 1998
  • 목적 : matrix ion chamber type의 EPID와 video camera based EPID를 이용한 portal image와 기존의 film을 이용한 port film의 영상의 질을 객관적으로 비교 평가하여 EPID의 유용성을 알아보고자 본 연구를 계획하였다. 대상 및 방법 : 1997년 4월부터 10월까지의 인하대 병원과 세브란스 병원에서 방사선 치료를 받은 골반강내 치료 환자 각 10명씩을 대상으로 환자 1명 당 5-10회의 port film과 EPID를 이용한 portal image를 동시에 얻어 비교하였다. 환자의 나이는 32세에서 79세이었고 2명의 AP영상을 제외하고는 모두 PA영상을 얻었다. 환자의 두께는 17cm에서 20cm으로 비교적 균일하였다. beam energy는 10MV X-ray를 사용하였고 dose rate은 100-300MU/min으로 2-10MU을 주어 영상을 얻었다. port film은 Kodak diagnostic film을 사용하였고 film을 넣는 cassette는 납을 전후에 부착한 것을 이용하였다. source to detector(film) distance는 140cm으로 하였다. 영상의 판독은 4명의 치료방사선과 의사에 의해서 시행되었으며 pelvic brim, sacrum, acetabulum, iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint를 각각 very clear(1), clear(2), visible(3), not clear(4), not visible(5) 다섯 단계로 나누어 점수를 주었다. 결과 : video camera based EPID를 이용하여 얻은 영상을 비교하여 보았을 때 film을 이용한 port film과 enhancement를 시행하지 않은 portal image는 각 해부학적 구조에서는 차이를 보이지 않았다. 그러나 portal image를 window level로 영상의 변화를 주었을 때는 sacrum과 obturator는 영상의 판독에 도움이 되었다. 또한 portal image를 CLAHE로 enhance를 하였을 때는 모든 해부학적 구조물의 판독이 film보다 용이한 것으로 나타났다. matrix ion chamber type의 EPID를 이용하여 얻은 영상에서도 역시 port film과 영상의 변화를 주지 않은 portal image간에는 커다란 차이를 보이지 않았으나, portal image를 window level로 변화를 주었을 경우는 portal film에 비하여 영상의 질이 더욱 좋아지을 알 수 있었다. 결론 : 방사선 치료를 받는 환자 중에서 골반강의 영상에서는 EPID의 영상의 질은 기존의 port film과 비교하여 차이가 없었으며, window level로 영상에 변화를 주거나 enhance를 하였을 경우는 port film보다 더 나은 영상을 얻을 수 있어 기존의 port film을 대체 할 수 있을 것으로 생각된다.

  • PDF