• Title/Summary/Keyword: Image Detector

Search Result 918, Processing Time 0.024 seconds

Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning (3차원 안모분석을 위한 저선량 Multi-detector CT 영상의 유효선량 및 화질 평가)

  • Chung, Gi-Chung;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.15-23
    • /
    • 2010
  • Purpose : This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. Materials and Methods : 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Results : Effective doses in ${\mu}Sv$ ($E_{2007}$) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. Conclusion : From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

Characterizing Overlap Area of KOMPSAT-3 (다목적실용위성 3호 Overlap 영역의 특성분석)

  • Seo, Doo-Chun;Kim, Hee-Seob
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.154-162
    • /
    • 2011
  • The KOrea Multi-Purpose Satellite-3 (KOMPSAT-3) provides 0.7 m Ground Sample Distance (GSD) panchromatic image and 2.8 m GSD multi-spectral image data for various applications. The KOMPSAT-3 system data will be applied in the field of earth observations, covering land, sea, coastal zones, and Geographic Information Systems (GIS). In order to keep the swath width of 15km at nadir view of KOMPSAT-3, CCD consist of approximately 24,020 pixels excluding 20 dark pixels at both sides and has overlap region. Because there are no CCD-line sensors with a pixel size of $7{\mu}m$, the field of view is separated into 2 parts and imaged on 2 detectors, each with 12,080 pixels. Therefore, 2 detectors have different geometric characteristic. This paper provides image simulation for geometric characteristics analysis of overlapping area of KOMPSAT-3 using KOMPSAT-2 image data.

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF

DOI Detector Design using Different Sized Scintillators in Each Layer (각 층의 서로 다른 크기의 섬광체를 사용한 반응 깊이 측정 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.11-16
    • /
    • 2023
  • In preclinical positron emisson tomography(PET), spatial resolution degradation occurs outside the field of view(FOV). To solve this problem, a depth of interaction(DOI) detector was developed that measures the position where gamma rays and the scintillator interact. There are a method in which a scintillation pixel array is composed of multiple layers, a method in which photosensors are arranged at both ends of a single layer, a method in which a scintillation pixel array is constituted in several layers and a photosensor is arranged in each layer. In this study, a new type of DOI detector was designed by analyzing the characteristics of the previously developed detectors. In the two-layer detector, different sizes of scintillation pixels were used for each layer, and the array size was configured differently. When configured in this form, the positions of the scintillation pixels for each layer are arranged to be shifted from each other, so that they are imaged at different positions in a flood image. DETECT2000 simulation was performed to confirm the possibility of measuring the depth of interaction of the designed detector. A flood image was reconstructed from a light signal acquired by a gamma-ray event generated at the center of each scintillation pixel. As a result, it was confirmed that all scintillation pixels for each layer were separated from the reconstructed flood image and imaged to measure the interaction depth. When this detector is applied to preclinical PET, it is considered that excellent images can be obtained by improving spatial resolution.

Center Determination for Cone-Beam X-ray Tomography

  • Narkbuakaew, W.;Ngamanekrat, S.;Withayachumnankul, W.;Pintavirooj, C.;Sangworasil, M.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1885-1888
    • /
    • 2004
  • In order to render 3D model of the bone, the stack of cross-sectional images must be reconstructed from a series of X-ray radiographs, served as the projections. In the case where the distance between x-ray source and detector is not infinite, image reconstruction from projection based on parallel-beam geometry provides an error in the cross-sectional image. In such case, image reconstruction from projection based on conebeam geometry must be exercised instead. This paper is devoted to the determination of detector center for SART conebeam Technique which is critically effect the performance of the resulting 3D modeling.

  • PDF

FEASIBILITY OF IMAGE PROCESSING TECHNIQUES FOR LAKE LEVEL EXTRACTION WITH C-BAND SRTM DEM

  • Bhang, Kon-Joon;Schwartz, Franklin Walter;Park, Seok-Soon
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.173-176
    • /
    • 2008
  • Lake studies play an important role in water management, ecology, and other environmental issues. Typically, monitoring lake levels is the first step on the lake studies. However, for the Prairie Pothole Region (PPR) of North America having millions of small lakes and potholes, on-site measurement for lake levels is almost impossible with the conventional gage stations. Therefore, we employed Geographic Information System (GIS) and remote sensing approach with the Shuttle Radar Topography Mission data to extract lake levels. Several image processing techniques were used to extract lake levels for January, 2000 as a one-time snapshot which will be useful in historic lake level reconstruction. This study is associated with other remote sensing datasets such as Landsat imagery and Digital Orthophoto Quadrangle (DOQ). In this research, firstly, image processing techniques like FFT filtering, Lee-sigma, masking with Canny Edge Detector, and contouring were tested for lake level estimation. The semi-automated contouring technique was developed to accomplish the bulk processing for large amount of lakes in this region. Also, effectiveness of each method for bulk processing was evaluated.

  • PDF

A Background Image Generation Method for Image Detector Using Detected Vehicle Information (차량 탐지 정보를 이용한 영상 검지기의 배경 영상 생성 방법)

  • Kwon, Young Tak;Kim, Yoon Jin;Park, Chul Hong;Kim, Hee Jeong;Soh, Young Sung
    • Journal of Advanced Navigation Technology
    • /
    • v.3 no.1
    • /
    • pp.60-68
    • /
    • 1999
  • In this paper, we propose a new background generation method for image detector for traffic information collection. Conventional methods result in bad performance when there are frequent traffic jams due to heavy traffic. To improve on this, we use high level information from vehicle detection. Only part of the image that is not considered as vehicle is used in background generation. The proposed method finds background more robustly than that of the conventional methods even in the presence of heavy traffic.

  • PDF

The Development for Vision-Based Realtime Speed Measuring Algorithm (영상처리를 이용한 여행시간 및 속도 계측 알고리즘의 개발)

  • 오영태;조형기;정의환
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.4
    • /
    • pp.107-129
    • /
    • 1996
  • Recently, surveillance system designed to collect various trsffic information are becoming new areas of development . Among these, the image detector is a ayatem which can measure the travel time and speed in realtime and this is emerging as the most effcient tool to be available in future related areas. But in measuring wide-area information in realtime, the image detector are yet full of problem in its accuracy. The aim of this ahesis is to develop an algorithms which can collect wide-area information such as travel time and travel speed in urban networks and freeways in realtime. The information on wide-area such as travel time and travel speed is important in accomplishing strategic function in traffic control. The algorithm developed from this study is based on the image tracking model which tracks a moving vehicle form image datas collected continuously, and is constructed to perform realtime measurement. To evaluate the performance of the developed algorithms, 600 ind vidual vehicles in total were used as data for the study, and this evaluation was carried out with the differenciation of day and night condition at the access roads in front of AJou University, In the statistical analysis results, the error rate was recorded as 5.69% and it has proved to be applicable on the field in both day and noght conditions.

  • PDF

Character Detection in Complex Scene Image using Harris Corner Detector (해리스 코너 검출기를 이용한 배경 영상에서의 문자 검출)

  • Kim, Min-ha;Kim, Mi-kyung;Cha, Eui-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.97-100
    • /
    • 2013
  • In this paper, we propose a detection method of the character rather than cursive, containing many components of the vertical and horizontal direction in complex background image. The characters have many dense corners but the background has few sparse corners. So we use harris corner detector and cluster the corners by using the position of the detected corners for detecting character regions. To merge or filter character regions, we analysis a histogram of gray image of character regions. In each improved region, we compare histograms of R, G, B channels to detect characters.

  • PDF

Development of a multi-modal imaging system for single-gamma and fluorescence fusion images

  • Young Been Han;Seong Jong Hong;Ho-Young Lee;Seong Hyun Song
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3844-3853
    • /
    • 2023
  • Although radiation and chemotherapy methods for cancer therapy have advanced significantly, surgical resection is still recommended for most cancers. Therefore, intraoperative imaging studies have emerged as a surgical tool for identifying tumor margins. Intraoperative imaging has been examined using conventional imaging devices, such as optical near-infrared probes, gamma probes, and ultrasound devices. However, each modality has its limitations, such as depth penetration and spatial resolution. To overcome these limitations, hybrid imaging modalities and tracer studies are being developed. In a previous study, a multi-modal laparoscope with silicon photo-multiplier (SiPM)-based gamma detection acquired a 1 s interval gamma image. However, improvements in the near-infrared fluorophore (NIRF) signal intensity and gamma image central defects are needed to further evaluate the usefulness of multi-modal systems. In this study, an attempt was made to change the NIRF image acquisition method and the SiPM-based gamma detector to improve the source detection ability and reduce the image acquisition time. The performance of the multi-modal system using a complementary metal oxide semiconductor and modified SiPM gamma detector was evaluated in a phantom test. In future studies, a multi-modal system will be further optimized for pilot preclinical studies.