• 제목/요약/키워드: Illumination System

검색결과 1,043건 처리시간 0.025초

광학스캐닝 메커니즘 및 근적외선 카메라 광학계를 이용한 태양전지 웨이퍼 검사장치 개발 (Development of Inspection System With Optical Scanning Mechanism and Near-Infrared Camera Optics for Solar Cell Wafer)

  • 김경범
    • 반도체디스플레이기술학회지
    • /
    • 제11권3호
    • /
    • pp.1-6
    • /
    • 2012
  • In this paper, inspection system based on optical scanning mechanism is designed and developed for solar cell wafer. It consists of optical scanning mechanism, NIR camera optics, machinery and control system, algorithm of defect detection and software. Optical scanning mechanism is composed of geometrical camera optics and structured hybrid illumination system. It is used to inspection of surface defects. NIR camera optics is used for inspection of defects inside solar cell wafer. It is shown that surface and internal micro defects can be detected in developed inspection system for solar cell wafer.

착용형 시선 추적 장치의 스포츠 분야 적용을 위한 적외선 조명 변화 최소화에 관한 연구 (A Study on an Infrared Illumination Stabilization Method in a Head Mounted Eye Tracking System for Sport Applications)

  • 이상철
    • 제어로봇시스템학회논문지
    • /
    • 제15권3호
    • /
    • pp.265-272
    • /
    • 2009
  • In this paper, a simple optical method that uses an infrared(IR) cut filter is proposed to minimize variation of eye image by external infrared(IR) sources in a video based head mounted eye tracking system that is used in the field of sports. For this, the IR cut filter is attached to a head mount of the eye tracking system, and the camera with an IR LED is located between the IR cut filter and eye. In this structure, external IR is blocked by the IR cut filter, and the IR intensity on the eye can be controlled by the IR LED. Therefore, the illumination condition of the camera to capture the eye can be stable without being affected by external IR illuminations. To verify the proposed idea, variation of the eye image and intensity of the IR with/without the IR cut filter is measured under various illumination conditions. The measured data show that the IR cut filter method can block external IR effectively, and complex pupil detection algorithms can be replaced by a simple binarized method.

원격 디밍제어 기반 LED 가시광통신 시스템의 수신 특성 분석 (A Study on Receiving Characteristic Analysis of LED Visible Light Communication System based on Remote Dimming Control)

  • 홍근빈;장태수;김용갑
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권3호
    • /
    • pp.153-157
    • /
    • 2011
  • 본 논문에서는 고휘도, 신뢰성, 저 전력 소비, 긴 수명의 장점을 가진 조명으로 사용되는 LED를 이용한 실내 조명제어 가시광통신 시스템을 구현하기 위한 연구를 수행하였으며, 현재 가속화 되고 있는 유비쿼터스 등의 다양한 응용분야의 적용 가능성을 확인하고자 한다. 이러한 시스템을 구현하기 위해 컴퓨터 프로그래밍 언어를 사용하여 Date 신호를 전송하는 가시광 통신 송 수신기를 설계하여 통신 성능 실험을 하였다. 이번 연구 결과 원활한 Date의 송 수신이 이루어지는 실내 조명제어 가시광통신 구현이 가능함을 확인하였다.

LED 광원을 이용한 마스트 항해등 조명광학계 개발 (Optical Illumination System Design for LED Masthead Navigation Light)

  • 맹필재;장재현;김근율;유영문;김종수;김종태
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.24-31
    • /
    • 2014
  • This paper dealt with the LED optical illumination system design for the Masthead navigation light to replace halogen lamps. We made Fresnel lens satisfy luminous intensity distribution of "Convention on the International Regulation for Preventing Collisions at Sea(COLREG)". The optical system is designed by classifying three parts: light source, lens, and cut off plate. The source of light has been made to have the uniform horizontal and vertical light distribution by placing 6 LEDs at intervals of $54^{\circ}$, and as the cylindrical Fresnel lens, the lens has been designed to achieve the uniform horizontal and vertical light distribution in the range of plain light. Finally, the cover has been designed to block the light from the outside of plain light and ultimately met the standards for light distribution of navigation lights. In addition, the validity of design has been verified with manufacturing a trial product.

데오도라이트 시스템의 측정 오차 요인에 관한 연구 (A Study on Measurement Error Factors of Theodolite System)

  • 박홍철;윤용식;최석원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.272-275
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is 0.5 mm or better for distance 0 ~ 100 m. And the system is used for the measurement of a product for middle and large scale. This study was performed for finding the measurement error factors of the system. We could know that the main error factors are temperature, illumination and expertness. And we could find the measurement errors are $\pm$ 0.045 mm at temperature conditions is 2$0^{\circ}C$ and $\pm$ 0.012 mm at illumination condition is 300 lux. Also the results had significant differences by combinations of operator's expertness.

  • PDF

구조물의 진동 해석을 위한 비접촉 레이저 계측 시스템 개발 (Development Non-contact Laser Measuring System for Vibration Analysis of Structures)

  • 정현철;김경석;최정석;김성식;강기수;정승택;최태호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.911-914
    • /
    • 2003
  • The non-contact laser measurement system what can be used for the vibration analysis of structures is discussed. There are few systems using laser speckle interferometer for vibration analysis. One of these systems is the Electronic Speckle Pattern Interferometer (ESPI). With ESPI system, one can obtain the vibration mode shape qualitatively and the maximum vibration amplitude quantitatively of the structure at each resonance frequency. In this paper, the phase-shifting ESPI system with stroboscopic illumination for measuring vibration mode shapes is constructed and the operating software is programmed. The results are compared with that of commercial ESPI system.

  • PDF

홀로그래피 입자속도 측정시스템의 개발과 분무 액적에의 적용 (Development of Holographic Particle Velocimetry System and Its Application to Spray Droplets)

  • 추연준;강보선
    • 한국분무공학회지
    • /
    • 제10권3호
    • /
    • pp.17-28
    • /
    • 2005
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. In this study, diffused illumination holographic system to measure the sizes and 3D velocities of moving particles based on automatic image processing was developed. First of all basic optical systems for pulse laser recording, continuous laser reconstruction, and image acquisition, were constructed. To determine the position of particles in the optical axis, new three auto-focusing parameters(AEP), namely, Correlation Coefficient, Sharpness Index, and Depth Intensity were introduced and verified. The developed system was applied to spray droplets to validate the capability of the system. Three dimensional positions of particles viewed from two sides were decided using AFP and then 3D velocities of Particles were extracted by particle tracking algorithm. Comparison of measurement results of sizes and 3D velocities of particles with those obtained by laser instrument, PDPA, showed good consistency of the developed holographic system.

  • PDF

라인 스캔 카메라를 위한 저가형 시 균일 조명장치 구현 (Development of a Low-cost Lighting System for Line-acan Camera)

  • 김홍갑;김형석
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권5호
    • /
    • pp.235-240
    • /
    • 2000
  • A low cost lighting system for line-scan cameras has been developed with 3-phase power. When exposure time of line-scan camera is shorter than fluctuation period of illumination, the average gray value of each acquired 1-D image varies. Detecting defects on the objects's surface under such illuminating environment is very difficult. The proposed lighting system is composed of low-cost fluorescent lights based on 3-phase power. The specially designed lighting pack and the properly selected lighting position enable to get the rippleless lighting. The principle of the proposed lighting system has been explained analytically. The lighting system has been tested for fabric inspection with line-scan camera and it's efficacy has been proved.

  • PDF

자동차 차체 적용을 위한 레이저-아크 하이브리드 용접의 동축 모니터링 시스템 개발 (Development of Coaxial Monitoring System in Laser Arc Hybrid Welding for Automotive Body Application)

  • 박영환;이세헌;김철희
    • Journal of Welding and Joining
    • /
    • 제27권6호
    • /
    • pp.9-16
    • /
    • 2009
  • In this paper, the coaxial monitoring system to capture image of weld pool was developed in laser-arc hybrid welding. In order to obtain the reliable image, green laser was used as a illumination system and measuring components such as band pass filter, ND (Neutral Density) filter and shutter speed was designed and optimized. Using this monitoring system, weld pool images were captured according to laser power, welding speed, welding current and interspace between laser and arc through the experiment. ANOVA (Analysis of Variation) was carried out to identify the influence of process variables on bead widths extracted from captured images of monitoring system. Welding speed and current were major factor to affect weld pool.

조명에 강인한 눈꺼풀 움직임 측정기반 운전자 감시 시스템 (An Illumination-Robust Driver Monitoring System Based on Eyelid Movement Measurement)

  • 박일권;김광수;박상철;변혜란
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제34권3호
    • /
    • pp.255-265
    • /
    • 2007
  • 본 논문은 지능형 자동차 개발을 위한 주간 및 야간 환경에서 차량 운전 시 발생할 수 있는 다양한 조명을 극복하고 운전자 졸음 상태를 단일 CCD(Charge Coupled Device) 카메라를 통해 감시하는 시스템을 제안한다. 운전 중 운전자 눈을 감시하여 졸음 상태를 판단하는 시스템에서 눈 검출 및 눈꺼풀 움직임 측정은 선행되어야 할 중요한 과정이다. 따라서 비전기반 시스템의 가장 큰 단점인 조명변화를 극복하며 눈 검출 성능을 높이고 실시간 처리가 가능한 간단한 조명 보정 알고리즘을 제안하였으며 또한 신뢰성 있는 졸음 판단을 위해 효율적인 눈꺼풀 움직임 측정 방법을 제안한다. 이러한 시스템은 실시간으로 처리되어야 하며 이를 위해 제안한 방법과 더불어 효율적인 눈 검증 방법으로 단계적 SVM(Cascaded Support Vector Machine)을 적용하였다. 한편, 제안한 알고리즘의 성능 측정을 위해 주간 및 야간의 다 양한 조명 변화 속에서 주행 중 수집된 운전자 동영상을 사용하였으며 자체 수집된 동영상에 대해 98% 이상의 눈 검출 성능 및 신뢰성 있는 눈꺼풀 움직임을 측정하였다. 최종 졸음판단 결과는 수집된 각각의 동 영상에 대한 PERCLOS(The percentage of eye-closed time during a period)를 비교함으로써 제안한 시스템의 성능 및 우수성을 보였다.