• Title/Summary/Keyword: Illuminating light

Search Result 332, Processing Time 0.026 seconds

Research of Optical Design Method for Prism Luminaire (조명기구용 프리즘의 광학 설계법에 관한 연구)

  • Seok, Dae-Il;Lee, Chang-Mo;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.19-25
    • /
    • 2007
  • We studied prism design method for actual light source that have bulk in order to accomplish particular intensity distribution. When we know incidence angle and try to send ray to given direction, numerical formula that yields prism vertical angle, and then vertical angles were calculated sequentially. After analyzing problem that supposing to point light source, supplemented this and derived applicable prism design method on bulk light source. The intensity distribution and efficiency that came out by each design results were compared and analyzed, we got improved results through supplemented design method.

Study on Development of Light Duct System for Perimeter Occupied Zone on Underground Space (지하대공간에 있어 Perimeter Occupied Zone에 대한 채광덕트 시스템 개발에 관한 연구)

  • 김회서;이성주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.21-26
    • /
    • 1999
  • Using daylight in underground spoce may significantly reduce electric lighting load and give a visually comfortable environment. This reper describes a fundaIrentaI study on light duct system to predict inter illuminance ratio on underground periIreter occupied zone level. As a result, integral equation for inter-reflection program are developed and by using optimize light duct system can gives daylight on deep underground space. space.

  • PDF

A Study on the Luminance Measuring Method and Regional Measured Results for Outdoor Signboards with Lighting Considering Light Pollution (빛공해를 고려한 옥외발광광고물의 휘도측정법 연구 및 지역별 측정결과)

  • Kim, Hyun-Ji;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.1-8
    • /
    • 2012
  • To suggest lighting regulations to prevent light pollution, domestic and international standards were analyzed and the luminance of outdoor signboards of main street at night was measured. In addition, to regulate the methods of luminance measurement, experiments on the measuring distance and direction from the signboards were conducted. The regulations were set as maximum luminance for outdoor signboard lightings of channel letter type, and limitations were suggested on each of the four lighting zones.

A Study of Lighting Environment to Improve the Visibility of Crosswalk in Rural Highway (지방부도로 횡단보도의 시인성 향상을 위한 조명환경에 관한 연구)

  • Lee, Mi-Ae;Lee, Suck-Ki;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.26-35
    • /
    • 2013
  • According to traffic accidents-related statistics, 57.6 percent of the fatality of vehicle-to-pedestrian accident, occurred on crosswalk in rural highways. Ministry of Land, Transport and Maritime Affairs in South Korea is conceiving to reduce in the number of the fatality. This study is to reestablish the criteria of implementing lighting through field experiments and to develop an effective alternative of crosswalk lighting.

Phase Contrast Projection Display Using Photopolymer

  • Piao, Mei-Lan;Kim, Nam;Park, Jae-Hyeung
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.319-325
    • /
    • 2008
  • We propose a phase contrast filter using photopolymer, for the phase contrast projection display. The photopolymer has high photosensitivity such that its optically induced refractive index change has a linear dependency on the illuminating light intensity. We implemented a phase contrast projection display using photopolymer as a phase contrast filter. By controlling the refractive index change of the photopolymer, we successfully convert an input phase image into a high contrast intensity image. We also investigated the effect of the photopolymer illumination condition on the quality of the displayed intensity image. As a projector, we achieved 82% phase to intensity conversion efficiency, which implies that the proposed method can potentially have much higher light efficiency than conventional projection display.

Effects of Correlated Color Temperature of LED Light Sources and a Flourescent Light Source on Visual Performance (LED광원과 형광광원의 상관색온도가 시작업 성능에 미치는 영향)

  • Baik, Seung-Heon;Jeong, In-Young;Shin, Hwa-Young;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.18-26
    • /
    • 2009
  • Recently, from an environmental conservative point of view, the need of high-efficiency lighting system, using LED(Light Emitting Diode) light sources have been increased. However, applied LED light sources without regard to its color and pattern provide visual discomfort to occupant. The objective of this study is not only to evaluate the performance of task work under different correlated color temperature condition, but also furnish the preliminary data as concerning its purpose and user of inner space. For the purpose of this study, two types of LED light sources and a fluorescent light source were selected. Thirty undergraduate students served as the participants. Two different task work sheets were conducted to evaluate the accuracy and duration of time. Results from subjective performance, task work of error modification showed that LED light sources were 2.5[%] higher in accuracy with 17.1[%] lower duration than a fluorescent light source. In the case of reading task work, It is presented 20.6[%] decrease with the LED light sources comparison with a fluorescent light source.

The Subjective Evaluation on White Light Property and Color Appearance of Single Chip LED and RGB Multi Chip LED (단일칩 LED와 RGB 멀티칩 LED의 백색광 특성 및 색 보임에 대한 주관평가 연구)

  • Sim, Yun-Ju;Kim, In-Tae;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • To produce the white light, there are a single chip method using the blue light and phosphor coating, a multi chip method by mixing R, G, B light.. Multi chip method is proper for the smart lighting system by controling color and color temperature. And color rendering of single chip LED is good by even spectral distribution. To apply application technic like smart light system, this paper analyzed the properties of single chip LED and RGB multi chip LED, and implemented the 2 part subject evaluation for single chip LED and RGB multi chip LED. The first part is comparison of properties for single chip LED and RGB multi chip and second part is color appearance evaluation of 8 colors in each lighting environment.

A Basic Study on Performance Evaluation of Permanent Supplementary Artificial Lighting of Interior(PSALI) using a LED Light Source (LED광원을 이용한 실내상시보조인공조명(PSALI)의 성능평가에 관한 기초적 연구)

  • Lee, Jin-Sook;Kim, Byoung-Soo;Kim, So-Yeon;Jung, Young-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.16-23
    • /
    • 2011
  • Since the first lighting light source was invented, lighting has turned into superior-quality lighting considering the amenity of occupants, and the characteristics of a light source has developed rapidly. So this research confirmed the lighting performance of a dimmer control system and an ON-OFF control system via the existing light source, and analyzed the basic lighting environment of Permanent Supplementary Artificial Lighting of Interiors(PSALI) through the physical comparison and evaluation of a LED lamp substituted for a fluorescent lamp used in a dimmer control system, showing that the lighting physical quantity characteristics of an ON-OFF control system and a dimmer control system are similar to each other and that they are effective in terms of energy saving. Besides, it was shown that introducing a LED light source to a dimmer control system improves lighting environments and largely reduces energy consumption.

Effects of LED Lamps for Replacement of Metal Halide Lamp in Roadway Lighting Environment (LED램프와 메탈램프가 도로조명환경에 미치는 특성 비교평가)

  • Lee, Myung Gi;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.47-52
    • /
    • 2013
  • The problems of light pollution first became an issue in the 1970s when astronomers identified the degradation of the night sky due to the increase in lighting associated with development and growth. As more impacts to the environment by lighting have been identified, many attempts have been made for reducing light pollutions. To prevent light pollution and increase energy efficiency, Seoul Metropolitan Government(SMG) replaced metal halide road lighting to LED luminaire in four arterial highway in Seoul. The present study compared the lighting characteristics of metal halide and LED luminaire in terms of Korea Standard for road lighting(KS A 3701) and BUG rating from Illuminating Engineering Society of North America(IESNA). The results showed that LED luminaire increased road surface luminance up to 2 times in average compared to the metal halide environment. Also, LED luminaire reduced the glare value by 2 times and luminous flux over 50% than the metal halide luminaire. In comparison with the BUG ratings, LED luminaire rated 1 degree lower for the backlight ratings and 3-4 degrees lower for the uplight ratings. The measured values testified that the LED luminaire is effective for roadway lighting and light pollution reduction.

A Study on the Design Standard of Museum Display Lighting in Consideration of the Damage by Optical Rediant Energy from Light Sources (광방사 에너지에 의한 손상을 고려한 박물관 전시조명 설계기준 설정에 관한 연구)

  • 김홍범;권세혁
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.1
    • /
    • pp.29-36
    • /
    • 1994
  • Exhibitlon lighting design be done after due consideration of the photochemical reaction and heating effcts upon exposure to light In this study the balanced judgement is as follows. 'The most light-susceptible material should be illustrated less than 5O(lx](illumlnance-hours per year: 120,OOOlx.h)and the illuminance of moderately sensitive material is 200(lx] (illuminance hours per year: 480,OOOlx.h). Moreover to minimize damage the sources of light should not only contribute as little as heat possible but remove ultraviolt radiation by filters. Also the sources of light must have good color rendering and low color temperature.

  • PDF