• Title/Summary/Keyword: Illuminance change

Search Result 64, Processing Time 0.028 seconds

Psycho-physicological Effects of the Dynamic lighting on VDT workers (조명환경의 변동이 작업자에게 미치는 심리.생리적 영향)

  • 엄기수;박근상
    • Proceedings of the ESK Conference
    • /
    • 1998.04a
    • /
    • pp.194-199
    • /
    • 1998
  • The purpose of this study is conducted to evaluate the psycho-physiological effects of the dynamic lighting on VDT workers and to establish the dynamic lighting design guides. The main experimental factors are changes of illuminance. There were five conditions including 1) ripid change, 2) slow change at 300lx .approx. 500lx, 3) a static illuminance level at 300lx, and 4) rapid chante, 5) slow change at 200lx .approx. 300lx. The ranges of change were set typical illuminance level for the simple visual task requirement and reasonable to a VDT task ; 200-300-500lx. The psycho-physiological measurements used were EEG, R-R interval, CFF, near point accommodation, feeling perceived fatigue, and work performance. Analysis of psycho-physiological factors shows that higher illumination level conditions are more affirmative effects than lower on VDT workers under 500lx except for the results of feeling perceived fatigue. And about the speed of changes of illuminance level. The conditions of slow change were better than the others in terms of the work performance as well as psycho-physiological results.

  • PDF

The design and the analysis of a LED illumination lens using the overlapped model (중첩모델을 이용한 조명용 LED 렌즈설계 및 분석)

  • You, Ilhyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.157-164
    • /
    • 2017
  • In this research, the overlapped illumination model was used for designing a freeform LED lens with a uniform illuminance distribution on its illuminating plane, and their performances and tolerances were compared. And, the illuminations on a illumination plane was measures for change with average illuminance and illuminance uniformity. As a result of the tolerance analysis about z-axis direction change, thickness change in lens and tilt change of light emission and characteristic change in LED source, overlapped model and divergent illumination model are similar to the performance about Z-axis direction change of light emission in LED source. but the uniformity illumination value in this overlapped model is more remarkably value than it in divergent illumination model about thickness change in LED lens. Also, even though the lens based on a divergent illumination model showed good performance compare to the lens based on an overlapped illumination model, the latter was less the deviation to variation of LED beam radiation ability.

A Study on the Extraction of Correlated Color Temperature, Illuminance, Control Speed under Controllable LED Lighting in the Kitchen Space (제어가능한 부엌공간 LED조명에서의 색온도, 조도, 제어속도 추출에 관한 연구)

  • Lee, Jin-Sook;Jeong, Chan-Ung;Park, Ji-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.1-14
    • /
    • 2014
  • This study has found out appropriate scopes of correlated color temperature and illuminance value with regard to general diffused lighting and work in the kitchen. It also has presented appropriate photometric quantity control speed for behavioral change with the following results. 1)For general diffused lighting, the appropriate photometric quantity has turned out to be 4,000 to 4,500K in color temperature and illuminance value of 300 to 400lx. And 300lx at 4,500K has proven to be the most comfortable, behavior-appropriate, and preferred pair. 2)As far as appropriate photometric quantity for work is concerned, color temperature of 4,000 to 5,000K and illuminance value of 600 to 800lx are appropriate, while 700lx at 4,500 to 5,000K are the most comfortable, behavior-appropriate, and preferred set. 3)As for appropriate photometric quantity control speed in behavioral change, 3 to 5 seconds has proven the most comfortable, appropriate, and preferred for behavioral change from entry to general areas and 1 to 3 seconds for change from general to work.

The design and the analysis of a LED lens for forming a uniform illumination on an illuminating plane (균일한 조도를 위한 LED 조명용 렌즈 설계 및 분석)

  • You, Ilhyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.954-964
    • /
    • 2015
  • In this research, an overlapped illumination model was newly proposed for designing a freeform LED lens with a uniform illuminance distribution on its illuminating plane. Based on the proposed model and conventional illumination models, freeform lenses were designed and their performances and tolerances were compared. As a result of the tolerance analysis about thickness change in lens, position, size change, central direction change of light emission and characteristic change in LED source. This proposed model and divergent illumination model are similar to the performance about central direction change of light emission in LED source. but the uniformity illumination value in this proposed model is more remarkably value than it in divergent illumination model about characteristic change in LED source.

A Study On the Design of Balaced Illuminance Using Lumen Flux Method (광속법을 이용한 등배치 설계에 관한 연구)

  • 최홍규;최병숙;정성윤;김진성
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.175-180
    • /
    • 1999
  • This paper presents the effective design of the change of average illuminance and the arrangement of lamps by changing the form of working area and adjusting the distance between the wall and light. This study is intended to simplify the complex calculation of illuminance through the development of application program. It's plan to study application programs that can attain the value of advanced uniformly-distributed illuminance and average illuminance by changing the distance between the horizontal/vertical wall and lamp and between the horizontal/vertical lamp and lamp.

  • PDF

Effect of Thermal Environment and Illuminance on the Occupants Works based on the Electroencephalogram and Electrocardiogram Analysis (뇌파와 심전도 분석을 기반으로 한 온열환경 및 조도가 재실자의 업무에 미치는 영향)

  • Kim, Hyung-Sun;Lim, Jae-Hyun;Kim, Hyoung-Tae;Kim, Hyoung-Sik;Kuwak, Won-Tack;Kim, Jin Ho
    • Science of Emotion and Sensibility
    • /
    • v.17 no.3
    • /
    • pp.95-106
    • /
    • 2014
  • This research analyzed biosignals associated with the change of emotion from lighting felt by the occupants and task type under various indoor thermal environments and illuminance, and examined the biosignals' impacts on work. To this end, the indoor thermal environment was constructed on the basis of PMV (predicted mean vote) index value, and various indoor environments were created by changing the brightness of LED stands. In this manner, a variety of indoor environments were constructed, and experiments were carried out. This research evaluates the sensibility response to lighting through a questionnaire survey in the given environment and incorporates different types of error searches. In this way, changes were analyzed by measuring electroencephalogram (EEG) and electrocardiograms (ECG). As a result, all biosignals on the task type showed significant differences from the thermal environment change. When PMV index value was 0.8 (temperature: $25^{\circ}C$, humidity: 50 %), concentration and attention were the most activated. However, the biosignals did not show significant differences from the illuminance change. Concentration on an occupant's work capability was confirmed to be closely related to the thermal environment. As for the subjective emotional response to lighting, the occupants felt comfort as illuminance was lower, while they felt discomfort as illuminance was higher. However, there were no significant differences from the thermal environment change.

A Study on Image Evaluation consequent on Lighting Environment in time of reading in Learning Space (학습공간에서의 독서 행위 시 조명환경에 따른 이미지평가 연구)

  • Lee, Jin-Sook;Park, Ji-Young;Seo, Eun-Ji
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.1-9
    • /
    • 2015
  • The aim of this study is to deduce color temperature and illuminance by conducting the preference & affective evaluation consequent on illuminance change of ambient light in case of the lighting method of ambient light mixed with task light in time of reading which is visual work action among the action in learning space. As a result of the prior survey on preferred lighting method in time of the act of reading targeting 20 experts before doing evaluation, the method of lighting mixed with ambient light and task light was found to be the highest. Such a result is analyzed to be attributable to the fact that the less the difference in illuminance of nearby space and work surface because of the mixed method of lighting, the less the glare, which makes a reader feels easy and concentrate on reading. On the basis of descriptive statistics of evaluation results and impact analysis by category, this study recommends the application of combinations of ambient light illuminance ranging from 40lx to 100lx with color temperature of 5500~6000K in case of the method of lighting mixed with general light and task light.

A study on lighting Diffusion system of Daylight Duct System (광덕트방식 자연채광 시스템의 산광부에 대한 연구)

  • Song, Kyu-Ryol;Park, Gyeong-Woo;Ryu, Han-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.99-104
    • /
    • 2011
  • Daylighting system is an alternative to the energy crisis and environment change. And it is possible improvement system of Architectural Space Environment. Accordingly, it is very useful system. Because Daylight Duct System of Daylighting System gives high performance for its price, distribution rate is very high. But Daylighting Duct System is hard to accurate control. Accordingly, it is difficult to maintain continuously Daylight Environment in Interior Spaces. Lighting Diffusion System has been developed that it is Applying the principle of Reflector and prism diffuser for maximize the efficiency of lighting of Daylight Duct Systems through this study. And then compare lighting performance of Existing System and new Lighting Diffusion System through producing a mock-up. Thus, this study was carried out for the purpose of verification for excellence. It is that installed Each Daylighting Duct System for performance evaluation in a laboratory of width 4m, length 10m, height 2.5m. And illuminance was measured at noon on winter solstice(December 22) under clean sky. The actual measurement result was in the following. Newly developed lighting Diffusion system was measured maximum illuminance 399, minimum illuminance 221, average illuminance 141. Synthetically, daylight factor, uniformity factor and illuminance distribution were improved more than existing system. As a result, it was confirmed that was improved lighting Environment in Interior Spaces.

  • PDF

The Characteristics of the winter season window and indoor temperature due to the indoor plant (동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구)

  • Yun, Young-Il;Cho, Ju-Young
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.

A Color Temperature and Illuminance Controllable LED Lighting System (색온도와 조도 제어가능한 LED 조명 시스템)

  • Kim, Hoon;Youm, Jea-Kyoung;Chung, Won-Sup;Kim, Hee-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.10-22
    • /
    • 2009
  • This paper presents an LED lighting system with an LED color control algorithm that can independently change its color temperature and illuminance. To show the validity of the proposed algorithm, it is proven that its solution always exists. The proposed algorithm was applied to the control of an LED module that is composed of red, green, blue, and white (RGBW) LEDs. Its color temperature variation ranged from 3,500~7,500[$^{\circ}K$], and its illuminance ranges from 500~1,500[lux]. Within these range, the color temperature and illuminance deviations are as low as $\pm0.8$[%] when the junction temperature of LEDs are maintained at 40[$^{\circ}C$]. In the range of 30~70[$^{\circ}C$], the measured illuminance and color temperature deviations are as low as 2.1[%] and 3.6[%], and the compensated ones are as low as 1[%] and 0.49[%], when the desired illuminance and color temperature are 1,000[lux] and 6,500[$^{\circ}K$], respectively.nyang.ac.kr).