A Study on a Novel LED Lighting Fixture for Crosswalk Having Two Different Light Distributions (두 가지 배광을 갖는 LED 횡단보도 조명장치에 관한 연구)

  • Kim, Hyeong Jin;Lee, Dong Kyu;Kwak, Joon Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.9
    • /
    • pp.606-611
    • /
    • 2014
  • Recently, LED lighting fixtures for crosswalk become popular in order to recognize the pedestrians at crosswalk, which can enhance the safety of the pedestrian at crosswalk. However, there are several problems related to the LED lighting fixtures for crosswalk, such as a lot of energy consumption due to a constant illumination during night and glaring of pedestrians at the opposite side of crosswalk. In this study, in order to overcome these problems, we have investigated a novel LED lighting fixture for crosswalk, which has two modules with different angles ($60^{\circ}$, $120^{\circ}$). Illuminance of min and max at four-line city street crosswalk shown 50 Lux, 125 Lux, respectively. Illuminance of min and max at eight-line city street crosswalk shown 150 Lux, 200 Lux, respectively. Simulation investigation was optimized design using optical program. Prototype was verified measurement by goniometer system.

Development of Optical System for 50W LED Security Lamp (50W급 LED 보안등용 조명광학계 개발)

  • Jung, Byoung-Jo;Jang, Sung-Whan;Roh, Yong-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.296-305
    • /
    • 2012
  • In this paper, we develop about glare phenomenon at security light caused by light source's straight characteristic, maintaining uniformity ratio of illuminance as high, have long light distribution not by symmetry of rotation but a single axis. we develop second lens for security light that lack of light distribution phenomenon at each of security light can be solved. Our developed light system design satisfies lighting standard of security light's and shape of lens is single lens. so our lens optimizes designing or analysis by using lighting design and interpretation program. Making a Mock-up to do real measure, we have intensity of illumination and maintaining uniformity ratio of illuminance measurement data.

Modeling and Actual Investigation of Roadway Lighting in Jejusi (제주시 도로조명 실태조사 및 모델링)

  • Oh, Seong-Bo;Kim, Eel-Hwan;Lee, Sang-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.7
    • /
    • pp.1-5
    • /
    • 2006
  • Fixed lighting of public ways for both drivers and pedestrians can create a nighttime environment in which people can see comfortably and can quickly and accurately identify objects on the roadway being travelled. Roadway lighting can improve traffic safety, achieve efficient traffic movement and promote the general use of the facility during darkness. The design of a roadway lighting system involves consideration of visibility, economics, esthetics, safety and environmental conditions. This paper shows estimation of horizontal illuminance and uniformity ratio by actual measurement of roadway lighting at main streets in Jejusi and evaluation of Jejusi roadway lighting conditions for modeling by computer simulation.

Crime Prevention Through Environmental Design of Underground Parking in Commercial Facilities - Field survey of Underground Parking Spaces in Department stores, Large Discount Mart and Mixed Used Commercial Facilities - (상업시설 지하주차장의 CPTED계획요소에 관한 연구 - 대형마트와 백화점, 복합상업시설 지하주차장 현장조사 -)

  • Min, Young Hee;Kwon, Ju-Young;Ha, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.3
    • /
    • pp.129-137
    • /
    • 2016
  • Dark and desolate underground parking spaces in commercial facilities are optimal spaces for crime. First, this study reviewed 15 precedent CPTED guidelines and related literatures, and as a result extracted 45 CPTED planning criteria for underground parking facilities. Secondly by field survey, we investigated six parking spaces in commercial facilities whether they were planned properly based on 45 checklist items, in six categories of CPTED principles. In result, target facilities showed average 46.8% relevance ratio, which means less than a half of 45 items of CPTED planning factors were not applied. Guidelines suggest desirable illuminance level of more than 100 lux, however the measurement of illuminance levels in some parking spaces showed below 50 lux. Relatively department stores were keeping CPTED guidelines better than large discount mart and mixed used facilities. Definition of territory of loading dock and customer area should be clarified, clear signage and color scheme in different zones should be represented with higher level of territorial responsibilities and surveillance in mixed used facilities for further improvement.

Analysis of Scientific and Subjective Sleeping Measurements and Environmental Factors that Influence Sleep Efficiency of Seafarers (선원의 과학적 및 주관적 수면측정과 수면효율성에 영향을 주는 환경요인 분석)

  • Kwon, Young-Tae;Kim, Byeong-Jo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.3
    • /
    • pp.185-198
    • /
    • 2022
  • Purpose : We conducted a study to propose comparing subjective sleeping states data that was collected through scientifically measuring by using smartwatch and surveys for seafarers. In addition, we conducted a study to provide sleep though analysis of the environmental factors that influence the sleep efficiency of seafarers. Methods : For scientific measurement of seafarers' sleeping states, we measured the sleep hours and sleep efficiency for at least 3 days by using the healthcare function of smartwatches which are wearable devices. As for subjective sleeping states, we collected data on sleep hours and satisfaction rates on the quality of sleep through a survey. Lastly, as for the environmental factors that affect the sleep efficiency which is measured by smartwatches such as physical environment, bedroom space, bedroom furniture, bedding, a survey by self-evaluation method was conducted. Results : There were significant differences in the scientific sleep hours measurement values for all seafarers and the average sleep hours in the subjective survey. There were significant differences in the scientific sleep efficiency measurements of all the seafarers and the sleep satisfaction of the subjective survey, and there was no correlation between the scientific sleep efficiency and the subjective sleep satisfaction of all the seafarers. Among the environmental factors affecting the sleep efficiency of the seafarers, humidity variable had the most influence, and vibration and illuminance variables were also shown to have a very significant effect. Conclusion : We propose the measuring method that can analyze the quantitative and qualitative sleep states of the seafarers by using small activity recorders. In addition, it is very important to control humidity, vibration, and illuminance among ship environmental factors, and comfort, noise and bedroom size should also be reflected.

Lighting Analysis and Modeling on Jokcu Court (족구장 조명설비에 대한 해석 및 모델링)

  • Kim, Deog-Goo;Oh, Seong-Bo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.173-177
    • /
    • 2007
  • This paper describes the simulations on the actual measurement analysis and lighting design for recreational sports facility. Based on illumination requirements, sports may be divided into multidirectional sports and unidirectional sports. Typical multidirectional aerial sports include Jokcu. These sports require well distributed horizontal illumination and uniformity according to aiming. Therefore, this paper estimates horizontal illuminance and uniformity ratio by actual measurement of sports lighting at recreational Jokcu court in Cheju National University and evaluation of sports lighting conditions for optimal design by computer simulation.

  • PDF

A Study of HDR Software Reliability for the Luminance Map Creation (휘도맵의 작성을 위한 HDRI 생성 도구의 신뢰도에 관한 연구)

  • Hong, Sung-De
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.3
    • /
    • pp.81-89
    • /
    • 2012
  • Luminance is the most important quantity in lighting design and illuminating engineering. There are three methods for measuring luminance; using a conventional luminance meter, through the illuminance measurement and subsequent calculations and using digital imaging photometer. Recently, HDRI(High Dynamic Range Imaging) technique introduces a new method of capturing luminance values in a lighting environment. The radiance maps from HDRI are commonly used as visual environment maps for lighting analysis applications. For the HDRI, HDR software is needed to create HDR image. Currently, there is number of HDR software available. The purpose of this paper is to investigate whether a luminance map can be accurately captured by the various types of HDR software which include HDR Shop and Photoshop. To accomplish this goal a set of experiments was conducted. In order to assess the luminance values of the HDR image from HDR software, the values had to be compared to the ones obtained with conventional methods of luminance measurement.

Measurement and Characterization of Three Dimensional Luminous Flux (광원주위의 3차원 광선속 측정 및 평가)

  • 최종운;유문종
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.7
    • /
    • pp.314-318
    • /
    • 2003
  • This paper describes the construction, measurement, and characterization of an instrument for the distribution of luminous flux. This is done by measuring the flux around a light source while a detector and a source is rotating, and integrating it over an entire imaginary surface surrounding the source. We make a gonio radiometer to realize the scales of total luminous flux and geometrically integrate to get total spectral flux from standards of irradiance and illuminance. The uncertainties of a total flux in the gonioradiometry are 1.3%, and 0.4% below the standard lamps of NIST and NIM for each other.

Luminance Analysis of the Apartment Exterior Lighting using HDR Images (HDR이미지를 이용한 공동주택 외부조명의 휘도 분석)

  • Hong, Sung-De;Shin, Eun-Ju
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.2
    • /
    • pp.33-38
    • /
    • 2012
  • The purpose of luminance measurement in lighting design of urban scale is to prevent light trespass and light pollution, caused by over-bright. Specially, the illumination of road, tunnel and sports complex as urban infrastructure is measured by international standard for illuminance and luminance. It has been used the spot luminance meter and the image photometer to define the characteristics of qualitative and quantitative in exterior lighting. This study introduced the concept of HDR Image, procedure of HDR Image creation and analysis. Applications of HDR Image, particularly within the apartment building exterior lighting design analysis, have been demonstrated. The procedure proposed in this study is a affordable method that is useful for the assessment of luminance distribution in the scene with electric light. It also provides a measurement capability with the high resolution luminance data within a large field of view efficiently and quickly, which is not possible to achieve with a luminance meter.

Light Pollution Survey of Outdoor Lighting in Shopping Complex (쇼핑용 복합빌딩의 옥외조명으로 인한 광공해발생 실태조사)

  • Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.16-26
    • /
    • 2004
  • As the importance of outdoor lighting become more widely recognized, outdoor lighting has been installed in many buildings, plazas, landscape, and historical monuments in Korea, Outdoor lighting on showing complex, in particular, express its values as local landmarks. However, the excessive outdoor lighting in the large-scale shopping complex tends to cause light pollution. Many advanced countries are trying to create a comfortable lighting environment by the guidlines and regulations on outdoor lighting to prevent light pollution. For this research backgrounds, the light pollution of three showing complexes in Seoul have been investigated. For the purpose, luminance of building facade, horizontal illuminance, and vertical illuminance were measured with proper measurement instruments and compared the results with the CIE recommendations. The results of the study are as follows. As no cut-off luminaries are currently installed on pedestrian walks, some glare were occured partially. It also shows that the luminance of building facades are high to improve the degree of public awareness of buildings and advertisements. In other words, the luminance of the building facade, when compared with that of the CIE recommendations, is twice as high and the vatical illuminance of pedestrian walks is far higher than that of the CIE recommendations, which proves the existence of light pollution. As Korea has not yet provided proper regulations or guidelines for the control of light pollution, it is necessary to make appropriate codes for it.