• Title/Summary/Keyword: Illuminance Measurement

Search Result 79, Processing Time 0.027 seconds

Measurement and Forecast of the Visibility Range according to Illuminance and the Character Sizes (조도와 글자 크기에 따른 가시거리 측정과 예상)

  • Kim, Tae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.425-429
    • /
    • 2014
  • The visibility range is defined from where one can see. And it can be changed by illuminance, the character size, and eyesight and so on. In this paper the visibility range of 120 students is measured for 4 character sizes and 3 illuminations in a classroom. In order to forecast the visibility range of unmeasured data, using least square approximation theory, functions whose independent variable is illuminance and whose dependent variable is the visibility range is proposed. Because the visibility range is invariant according to illuminance, common logarithmic functions for 4 character sizes are used. The small difference between the postulated functions and the measured data verifies the accuracy of the functions.

A study on lighting Diffusion system of Daylight Duct System (광덕트방식 자연채광 시스템의 산광부에 대한 연구)

  • Song, Kyu-Ryol;Park, Gyeong-Woo;Ryu, Han-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.99-104
    • /
    • 2011
  • Daylighting system is an alternative to the energy crisis and environment change. And it is possible improvement system of Architectural Space Environment. Accordingly, it is very useful system. Because Daylight Duct System of Daylighting System gives high performance for its price, distribution rate is very high. But Daylighting Duct System is hard to accurate control. Accordingly, it is difficult to maintain continuously Daylight Environment in Interior Spaces. Lighting Diffusion System has been developed that it is Applying the principle of Reflector and prism diffuser for maximize the efficiency of lighting of Daylight Duct Systems through this study. And then compare lighting performance of Existing System and new Lighting Diffusion System through producing a mock-up. Thus, this study was carried out for the purpose of verification for excellence. It is that installed Each Daylighting Duct System for performance evaluation in a laboratory of width 4m, length 10m, height 2.5m. And illuminance was measured at noon on winter solstice(December 22) under clean sky. The actual measurement result was in the following. Newly developed lighting Diffusion system was measured maximum illuminance 399, minimum illuminance 221, average illuminance 141. Synthetically, daylight factor, uniformity factor and illuminance distribution were improved more than existing system. As a result, it was confirmed that was improved lighting Environment in Interior Spaces.

  • PDF

An Analysis of Classroom Illuminance with Simulation Program end Improvement of Classroom Illumination (시뮬레이션 프로그램을 활용한 교실조도 분식 및 개선안)

  • Shin, Hyun-Man;Jang, Woo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.14-23
    • /
    • 2009
  • The actual conditions of school illumination was investigated. The illumination state was classified by the number of installed luminaires per 1 classroom. The illuminance was measured and analyzed. The work surface illuminance was up to the standard, but the illuminance on blackboard was below standard when there was no local lighting. As a result of conducting a simulation based on the measurement of the reflection factors of the classroom finishing materials and lamp replacement and lamp cleaning, nine luminaires for general lighting and local lighting for the blackboard were required, and a design considering illumination maintenance was called for.

A study on the Comparison of Illuminace Simulations and Measured Values at the Stage Lighting (무대조명에서의 조도 시뮬레이션 결과와 실측값 비교 연구)

  • Lee, Jang-Weon;Yi, Chin-Woo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.230-234
    • /
    • 2009
  • In a planning of the Stage lighting, we carry out illumination simulation. After lighting construction we measured illuminance in order to compare the simulation results. And we study the errors between them.

  • PDF

A Study on Maintenance Planning for Efficient Urban Lighting in Wonju-si (원주시의 효율적인 도시조명을 위한 관리 계획에 관한 연구)

  • Lee, Yeon-So;Woo, Soo-Jin;Choi, Key-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.7-15
    • /
    • 2011
  • Based on the master plan, this study classified Wonju-si into five major regions and 19 areas by analyzing its night characteristics and deduced problems by analyzing quantitative light distribution of major points at the regions and areas through the measurement of illuminance and luminance and by surveying people's awareness. To develop eco-friendly night environment image of Wonju, Woju's identify was to be created by the planning for the 19 area and improvements for each type. Additionally, detailed items for maintenance were suggested by classifying them into illuminance, color temperature, luminance, lighting display, lighting time, light distribution type, and so forth.

Development of the Mobile Measuring System for Tunnel Lighting Luminance and Illuminance (차량을 이용한 터널조도 및 휘도 측정시스템 개발)

  • Kim, Dong-Jo;Jo, Duk-Soo;Suk, Dae-Il;Jung, Sueng-Kyun;Lee, Chang-Mo;Nam, Dong-Hoon;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.1-6
    • /
    • 2006
  • The tunnel is the place where brightness changes abruptly. It is important to grasp the road situation and the traffic situation of the tunnel accurately for safe and secure driving, and tunnel lighting installation should be well maintained. Luminance and illuminance of the tunnel inside should be measured periodically to maintain enough brightness. But traditional manual measurement could not guarantee the fastness and trustworthy of the measured values. In this paper, a mobile measuring system for tunnel lighting luminance and illuminance was developed and a result regarding the propriety of the system was derived.

A Study of Luminous Environment for Standard Illuminance in Residential Areas (주거공간의 실내공간별 조도기준을 위한 빛환경 연구)

  • Lee, Jung-Eun;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.1-9
    • /
    • 2005
  • Light is an important environmental element for people to live and do creative activities in residential areas. Especially, people are used to live under artificial light in artificial interior surroundings for the most times. Currently, the lighting quality of residential areas has been improved, but it still does not reach to the recommended level because the luminous environment of present residential areas is only based on the life behavior which puts its priority to clear vision. Therefore, it is necessary that proper standard illumination must be used for various uses and purposes. From this point of view, this paper investigated the essence of light in residential areas, and the luminous environment for apartments was measured This paper finally established well-coordinated standard illuminance, derived from the measurement and analysis of luminous environment from these cases.

Illuminance Uniformity of Beam Projector for Solar Cell Quantum Efficiency Distribution Measurement (태양전지 양자효율 분포측정을 위한 빔프로젝터의 광조도분포 균일화)

  • Yu, Jae-Geun;Kim, Seung-Gwan;Lee, Dong-Hun;Park, Cheol-Ung;Park, Seung-Nam
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.10a
    • /
    • pp.298-299
    • /
    • 2009
  • Use of a DLP-beam projector is proposed to measure solar cell quantum efficiency distribution. The measurement requires a good spatial uniformity of the beam from the projector. We measured the spectral power distribution of the beam projector and the spatial uniformity of the white beam. By changing the gray level of the white beam at the measured spatial points, we improved the spatial illuminance uniformity to be about 2 % which was otherwise as much as 400 %.

  • PDF

Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe (Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정)

  • Kim, Ji Min;Han, Ah Yung;Lee, Ha Young;Lee, So Ra;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.168-172
    • /
    • 2016
  • The purpose of the optimal environment of the MRI room to measured luminance and illuminance of the MRI room and the monitor. University Hospital (n = 6) of the MRI (n = 10) in the luminance and illuminance Light Probe Xi Unfors (Unfors Instruments AB, Billdal, Sweden) was measured by using the. Black luminance level and white level of illuminance is repeated three times in the middle of the side of the monitor to obtain the mean and standard deviation using a t-test statistical processing was of significance test. Monitor luminance and black level in the average $1.78cd/m^2$, the standard deviation was $0.85cd/m^2$, white level average of $43.58cd/m^2$, the standard deviation of $13.19cd/m^2$. Illuminance of MRI room was the lowest value measured in accordance with the 30.5 lux, the maximum value is 601.3 lux, mean was measured by a variety of 177.86 lux. Luminance and illuminance of the MRI room and monitor is found to have statistically significant difference (p < .05). In conclusion, refer to the recommended standard of MRI and room monitor luminance and illuminance and to create an optimal environment.

Lighting Plan for Outdoor Space Using Lighting Measurements and Simulations in Residential Areas (조명환경 실측과 시뮬레이션을 통한 주거단지 내 옥외공간 조명계획)

  • Park, Byoung-Chul;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.1-8
    • /
    • 2005
  • Outdoor spaces are used for recreation, rest area, and night activities of residents. By these tendency, outdoor space is recognized as a very important space in residental areas. However, outdoor space is frequently used at night but lighting plan for these spaces is not suited for the selection of luminairce, arrangement of luminaires and planing of illuminance. From this point of view, this paper investigated the essence of light in outdoor space, analyzed different outdoor luminous environment and performed simulations. This paper finally suggested recommended level of illuminance and lighting plan of such spaces.