• Title/Summary/Keyword: Illuminance

Search Result 561, Processing Time 0.019 seconds

Analyses on Daylight Variations for Optimum Controls of Daylight Dimming Systems in a Small Office (소규모 사무실에 적용된 조광제어 시스템의 최적제어를 위한 주광변화 분석)

  • Yoon, Youn-Ju;Baik, Yong-Kyu;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.433-442
    • /
    • 2012
  • The influence of outdoor sky conditions on photosensor signals were examined to determine an appropriate index that is effectively used for optimum illuminance fluctuation when a daylight dimming system is used for a small office. Field measurements were conducted under various sky conditions. Results indicate that the outdoor global and vertical illuminance fluctuated within narrow ranges under clear and overcast sky conditions. The fluctuation of sky ratio under partly-cloudy sky caused wide ranges of illumnance fluctuation. A partially-shielded photosensor at backwall produced 56% of light output from fixtures controlled by a photosensor at ceiling. This implies that the photosensor at backwall does not always guarantee target illuminance due to the less output. The fluctuation of light output from fixtures were insignificant under clear and overcast sky. The fluctuation range of photosensor illuminance under partly-cloudy sky caused wide fluctuation ranges of light output. Regression result implies that the outdoor vertical illuminance was recommended for an effective index that is used for control of light output.

A Experimental Study the Wall Lighting focus on Rate of Illuminance : in case of fluorescent lamp and hallogen lamp (조도 비를 중심으로 한 벽면진열대의 조명실험연구 : 형광램프와 할로겐램프를 중심으로)

  • 김현지;안옥희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.1-7
    • /
    • 2004
  • This experimental study investigates the wall display of shoes shops among the commercial space to suggest a desirable lighting by focusing on the lighting on the lighting surroundings. The important outcomes of this study are summarized below. The result of the experiment for the wall lighting: For the wall lighting, which needs a diversity, there should be various light source or bigger rate of illuminance between the ambient lighting and the local lighting. There is another possibility that is we can use the lower rate of illuminance with the ambient lighting and the local lighting or higher illuminance generally. The other wall lighting, which need a luminance and a emotional response, will be more effective as they take the lower rate of illuminance with the ambient lighting and the local lighting or higher illuminance generally.

A Study on the Emergency and Recovery AC/DC Combination Lamps in the Electric Substations (변전소의 AC/DC 겸용 비상 및 복구 등에 관한 연구)

  • Park, Joon-Yeol;An, Youn-Ki;Kim, Jong-Soo;Shin, Hye-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.27-34
    • /
    • 2010
  • This study is for the improvement in the equipment environment of the emergency and recovery lamps in electric substations. To solve problem about the weak illuminance of existing emergency lamps, the AC/DC combination lamps and switches are reviewed. And the improved illuminance standards that are divided each room's purpose are suggested. It is based on a nuclear power plant's Illuminance Standards and a safety lamp's Illuminance Standards of Illuminance Standards Korean Industrial Standards - KS A 3011 -, not just 5~10[%] in according with normal lamp's illuminance. Lastly, The experiments are conducted to prove the suggested contents on this study. Consequently, a battery capacity is not increased, but illuminance of emergency and recovery lamps can be increased.

Measurement and Computing Method of the Average Illuminance in Residential Areas (공동주택의 조도측정 및 평균조도 산출방법)

  • Joo, Keun-Tak;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.1-8
    • /
    • 2006
  • The Five Point Method of KS and Four Point Method of IES are generally used to measure and compute the average illuminance in residential areas. Such methods of measurement should be used exactly according to the characteristics of the space and activities. Therefore, this study evaluated computation methods of the average illuminance in terms of comparing the measured values with simulated ones. The Five Point Method of KS is very closed to evaluate task illuminancefor appreciating activities at the center while the Four Point Method of IES is very closed to a concept of the average illuminance over the space excluding the possible maximum and minimum illuminance values.

Analysis on Visual Perception and Mood for Color of Light in a Small Office (소규모 사무실의 조명 색 변화에 따른 시각적 감지 및 무드 변화 분석)

  • Kang, Min-Hye;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.287-296
    • /
    • 2011
  • This study examines the influences of correlated color temperature and illuminance on visual perception and temporary mood sensation in a small office. Field measurements and surveys were conducted in a full-scale mock-up model. Twenty subjects participated in the survey under six lighting conditions formed by three color temperature and two illuminance levels. Results indicate that 4000 K color temperature was effective to mitigate glare sensation from light source. Lamps with low color temperature such as 2700 K was not recommended for office lighting since they are likely to caused glare and visual discomfort. Preferred color temperature was 4000 K and 6500 K for 750 lx and 500 lx target illuminance respectively. The increase of illuminance was not an effective contributor to improve mood perception. The illuminance should be lower than 500 lx to achieve good mood, but the illuminance level in office space should be considered with visual performance simultaneously. This study suggests that fluorescent lighting fixtures with 4000 K lamps would be usefully used for office lighting since they formed friendly conditions for better visual performance.

An Analysis of Illuminance Distribution in Fine Art Museum with Girdle Skylight Type (미술관에서의 상부 띠형 천창의 채광분포에 관한 연구)

  • Choi, Man-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.93-100
    • /
    • 2005
  • Character and illuminance distribution of daylighting is very important for the architectural plan in museum. Those data show bases for exhibition space design with daylighting and play a decisive role in visual perception of articles and space aesthetic. The goal of this paper was therefore to analyze the illuminance distribution in fine art museum with 3 typical girdle skylight types which are devided according to the art of protection from glare. This Experiment proved that they had a striking contrast with regard to the ratio of daylight illumination and illuminance distribution in spite of the same purpose of those development. The girdle skylight with a translucent glass showed the strongest value of the ratio of daylight illumination, but inequable illuminance distribution in space, excepting the area of the wall. However, the latticed reflector of light refracted daylight in the direction of wall and made illuminance distribution very equable in whole space. The ratio of daylight illumination at the girdle skylight which was located at the verge of the ceiling, was highest at the upper part of the wall and was reduced gradually from there, by way of the middle and under part of the wall, to the center of space.

A Study on the Illuminance Measurement and Improvement of Public Libraries in Daegu City (공공도서관 조도분석 및 개선방안 연구 - 대구지역을 중심으로 -)

  • Yoon, Hee-Yoon
    • Journal of Korean Library and Information Science Society
    • /
    • v.48 no.4
    • /
    • pp.1-20
    • /
    • 2017
  • The most important identity of public library is local public goods that guarantee access and use of knowledge and information of local residents. To justify this, the library must create an optimal lighting environment. Particularly, since the perception rate of information through vision is over 80%, it is necessary to secure proper illuminance. This study measured the illuminance level of public libraries in Daegu. Based on the results, this study suggested a desirable illuminance level for each space and proposed plans to secure and maintain proper illuminance(prospective revision of the KS A 3011, setting the illuminance range for each space of the local government, replacing the existing lighting fixtures with LED, enhance supervision of lighting management, establishment of basic principles for proper lighting and detailed plans for each space of the library, investigation and reflection on users' complaints and satisfaction, etc.)

A Study on the application of appropriate level of illuminance to the Cathedral based on lighting principles (조명원리를 기반으로 한 성당조도의 적정수준 적용분석 연구)

  • Bahn, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.685-696
    • /
    • 2017
  • In the spatial image composition of a cathedral, light is the most important element of changing the mind through vision. The religious meaning of light and its impact on human sensibility are believed to be very large. Therefore, in this study, 'Illuminance' is the most important research subject of a cathedral's worship space lighting plan elements. Illuminance is expressed by giving the clarity and form of space through a subtle spatial composition difference. The role of illuminance is essential for confirming the existence of space, and lighting controls the spatial atmosphere at an appropriate level. The standard and range of illuminance are set through the synthesis and analysis of related standards. Based on this, a related case study was conducted on cathedrals built in the Gangnam area of Seoul in the 1980s. The lighting-related factors were analyzed and the illuminance of the liturgical space and worship area were measured. The appropriate level of applicability was confirmed by comparison analysis. A plan for the illuminance application levels and elements applied in the cathedral lighting design is proposed.

A Study for Color and Illuminance Control Algorithm of Broadcast LED Lighting (방송용 LED 조명의 광색과 조도 제어 알고리즘에 대한 연구)

  • Shin, Dong-Seok;Park, Chul-Hyung;Park, Chong-Yeun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.6-17
    • /
    • 2015
  • In this paper, colors of broadcast lightings composed of Red, Green, and Blue LED(Light Emitted Diode) can be linearly and quantitatively controlled in low illuminance. Because LED cannot emit uniform illuminance in low illuminance, the colors of RGB LED are unmixable. Furthermore, the illuminances are nonlinear with the dimming values of the RGB LED due to the nonlinearity of the output illuminance with the current through the LED. This nonlinearity generated errors of the target colors and illuminances. The proposed algorithm set up the target colors, which is expressed by the color coordinates in CIE 1931 color space, and the target illuminances. Then the illuminances of RGB LED were calculated using color mixing theory. The calculated illuminances determined the dimming values of the RGB LED for transmission via DMX512 communication. After the broadcasting lighting received the dimming values of the RGB LED via DMX512 communication,.RGB LED can emit target color and illuminance, and be controlled by calculating the PWM(Pulse Width Modulation) duty ratio of the hybrid LED driver which be considered the nonlinearity for the illuminances of the LED. As a result, the proposed algorithm can linearly and quantitatively control the colors and illuminances in full range of illuminance. Then we verify experimentally that the errors of the emitted color coordination x, y and illuminance are 2.27%, 3.6% and 1.5%, respectively.

A Study on the Proper Illuminance Considering the Task Amenity of the Occupant in the Office Space (사무공간의 재실자의 작업면 쾌적성을 고려한 적정조도 도출)

  • Kim, In-Hye;Kim, Sung-Kyung;Hong, Won-Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.3
    • /
    • pp.159-167
    • /
    • 2020
  • For modern people who spend most of their time indoors, the indoor environment is very important. The efficiency of work depends on the amenity level of the occupants who use the office space. Therefore, the experiment was conducted to derive the proper illuminance according to the amenity level of the occupants. The experiment was conducted in an office in Chilgok County for 6 days. The illuminance of the indoor was changed every day, the feeling brightness of the occupants was measured every 10 minutes, the eye fatigue was measured every 30 minutes, and the overall illuminance and the work surface illuminance were measured every hour. Experimental results show that the feeling brightness is different depending on the position of the occupants. Also, it was found that the brightness survey preferred by the occupants required more proper illuminance than the brightness. In addition, it is considered that there is a correlation with indoor temperature and humidity as the eye fatigue of occupants. Brightness preference by time of day was analysis from feeling brightness of occupants and preference brightness of occupants, and then it was analyzed like eye fatigue to derive proper illuminance per hour. Based on these results, it can be utilized for improvement of eye amenity existing office space.