• Title/Summary/Keyword: Ideal image

Search Result 483, Processing Time 0.028 seconds

Studies of Character's Symbolism in (<동물농장>에 나타난 캐릭터의 상징성 연구)

  • Choi, Don-Ill
    • Cartoon and Animation Studies
    • /
    • s.38
    • /
    • pp.115-132
    • /
    • 2015
  • An animation is a tool to represent the consciousness of an author. It is a medium that converts his/her consciousness to time by the means of spaces. Image is the most inherent element among the elements of an animation. Character is the element that has the very core function among the elements of an image because a character is a shape that can deliver a story through various actions and facial expressions. In this context, is a representative satire animation that describes a ranked and unequal human society and selfishness and absurdity of human beings existed in the human society, based on the original work of George Orwell. Therefore, this study aims to study what the work tries to satirize through the meanings and symbols that the characters, animals, and spaces in the work. As a result of the study, it was found that the characters appeared in the work are metaphoric symbols that imply the meanings of each character, not just simple characters or spaces. In the work, the farm is a symbolic space that symbolizes a human world. John, a human being, is described as a dictator in an absolute Russian monarchy who suppresses people. Old Major, a pig, is described as an old pioneer that preaches the appropriation of a revolution while Snow Ball, a pig that follows the Major is described as a naive leader that dreams to establish a real socialist state where everybody lives equal, through successful revolution. Another pig, Napoleon is described as the more greedy dictator than human being. He killed Snow Ball for his private ambition and suppresses and exploits the same race, animals. That is, setting man and various animals in the relation of dominant class and subordinated class, the author generates conflicts among characters. Although the characters pursue an ideal society through revolution, it requires another revolution in the process, which expresses repetitive contradiction of human history in a symbolic and strong way.

PDA Transmission of Medical Images by CDMA (CDMA에 의한 의료영상의 PDA전송)

  • Lee, Myong-Ho;Lim, Jae-Dong;Ahn, Bung-Ju;Lee, Hwun-Jae;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.2
    • /
    • pp.13-22
    • /
    • 2007
  • The purpose of this study was to survey a development of the wireless transmission system of medical images for ubiquitous medicine. There have been many changes in medical equipments and medical record medical treatment and medical record within hospital and PACS(Picture Archiving Communication System) which is picture management system for patients can be typical cases. It is difficult to use these automated medical systems unless they are within hospital and in case of rapid image reading in the emergency cases or in absence of doctor, it is difficult to perform it immediately. The present study implemented an image transmission system using CDMA connection so that images in the server can be viewed at any time and in any place. Remote wireless diagnosis based on medical images using PDA is applicable to medical areas that require mobility, and the use of PDA can be an ideal alternative for point of care. The use of PDA enables prompt and accurate access to digital medical images, which in turn reduces medical accidents and improves the quality of medical services through high productivity and efficiency of medical practitioners' works. It also enables quick response to patients' demands and high-quality medical services and, consequently, patients' high satisfaction.

  • PDF

Usefulness Assessment of Automatic Analysis Program for Flangeless Esser PET Phantom Images (Flangeless Esser PET Phantom 영상 자동 분석 프로그램의 유용성 평가)

  • NamGung, Chang-Kyeong;Nam, Ki-Pyo;Kim, Kyeong-Sik;Kim, Jeong-Seon;Lim, Ki-Cheon;Shin, Sang-Ki;Cho, Shee-Man;Dong, Kyung-Rae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.63-66
    • /
    • 2009
  • Purpose: ACR (American College of Radiology) offers variable parameters to PET/CT quality control by using ACR Phantom. ACR Phantom was made to evaluate parameters which are uniformity, attenuation, scatter, contrast and resolution. Manual analysis method wasn't good for the use of QC because values of parameter were changed as it may user and it takes long time to analysis. Ki-Chun Lim, a nuclear scientist in AMC, developed program that automatically analysis values of parameter by using ACR Phantom to overcome above problems. In this study, we evaluated automatic analysis program's usability, through the comparing SUV of each method, reproducibility of SUV when repeated analysis and the time required. Materials and Methods: Using Flangeless Esser PET Phantom, the ideal ratio of 4 : 1 hot cylinder and BKG but it actually showed a ratio of 3.89 to 1 hot cylinder and BKG. SIEMENS Biograph True Point 40 was used in this study. We obtained images using ACR phantom at Fusion WB PET Scan condition (2 min/bed) and 120 kV, 100 mAs CT condition. Using True X method, 3 iterations, 14 subsets, Gaussian filter, FWHM 4 mm and Zoom Factor 1.0, $168{\times}168$ image size. We obtained Max. & Min. SUV and SUV Mean values at Cylinder (8, 12, 16, 25 mm, Air, Bone, Water, BKG) by automatic program and obtained SUV by manual method. After that, we compared manual and automatic method. we estimate the time required from opened the image data to final work sheet was completed. Results: Automatic program always showed same result and same the time required. At 8, 12, 16 and 25 m cylinder, manual method showed 6.69, 3.46, 2.59, 1.24 CV values. The larger cylinder size became, the smaller CV became. In manual method, bone, air, water's CV were over 9.9 except BKG (2.32). Obtained CV of Mean SUV showed BKG was low (0.85) and bone was high (7.52). The time required was 45 second, 882 second respectably. Conclusions: As a result of difference automatic method and manual method, automatic method showed always same result, manual method showed that the smaller hot cylinders became, the lager CV became. Hot cylinders mean region size, the smaller hot cylinder size becomes we had some trouble in doing ROI poison setting. And it means increase in variation of SUV. The Study showed the time required of automatic method was shorten then manual method.

  • PDF

In vivo Tracking of Transplanted Bone Marrow-Derived Mesenchymal Stem Cells in a Murine Model of Stroke by Bioluminescence Imaging

  • Jang, Kyung-Sool;Lee, Kwan-Sung;Yang, Seung-Ho;Jeun, Sin-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.5
    • /
    • pp.391-398
    • /
    • 2010
  • Objective : This study was designed to validate the cell trafficking efficiency of the in vivo bioluminescence image (BLI) study in the setting of transplantation of the luciferase expressing bone marrow-derived mesenchymal stem cells (BMSC), which were delivered at each different time after transient middle cerebral artery occlusion (MCAO) in a mouse model. Methods : Transplanting donor BMSC were prepared by primary cell culture from transgenic mouse expressing luciferase (LUC). Transient focal infarcts were induced in 4-6-week-old male nude mice. The experiment mice were divided into five groups by the time of MSC transplantation : 1) sham-operation group, 2) 2-h group, 3) 1-day group, 4) 3-day group, and 5) 1-week group. BLI for detection of spatial distribution of transplanted MSC was performed by detecting emitted photons. Migration of the transplanted cells to the infarcted area was confirmed by histological examinations. Differences between groups were evaluated by paired t-test. Results : A focal spot of bioluminescence was observed at the injection site on the next day after transplantation by Signal intensity of bioluminescence. After 4 weeks, the mean signal intensities of 2-h, 1-day, 3-day, and 1-week group were $2.6{\times}10^7{\pm}7.4{\times}10^6$. $6.1{\times}10^6{\pm}1.2{\times}10^6$, $1.7{\times}10^6{\pm}4.4{\times}10^5$, and $8.9{\times}10^6{\pm}9.5{\times}10^5$, respectively. The 2-h group showed significantly higher signal intensity (p<0.01). The engrafted BMSC showed around the infarct border zones on immunohistochemical examination. The counts of LUC-positive cells revealed the highest number in the 2-h group, in agreement with the results of BLI experiments (p<0.01). Conclusion : In this study, the results suggested that the transplanted BMSC migrated to the infarct border zone in BLI study and the higher signal intensity of LUC-positive cells seen in 2 hrs after MSC transplantation in MCAO mouse model. In addition, noninvasive imaging in real time is an ideal method for tracking stem cell transplantation. This method can be widely applied to various research fields of cell transplantation therapy.

A Study on the Franchise identity design (프랜차이즈 아이덴티티 디자인에 관한 연구)

  • Kim, Hun
    • Archives of design research
    • /
    • v.15 no.1
    • /
    • pp.349-358
    • /
    • 2002
  • CIP, or Corporate Identity Program is a program to standardize, conforming to a set of regulations, various visual media which form a corporate environment based on the concepts drawn from the corporate strategies in order to actively create a planned but ideal corporate image. However, both the recent corporate renovation and the emergence of a new type of corporations prompted by a rapid change in an corporate environment caused the existing corporate concepts to be adapted to such a change. Particularly various visual media related to a corporate image are getting digitalized, and the emergence of a new and varied type of visual media give rise to a new pattern of the identity design accommodating such changes. It may be improper and insufficient for the existing CIP to be applied on the franchising business which is considered most suitable for the new corporate environment. Business firm's office work has long been operated in an computing environment where the computer does all the work, and an individual home as well as small business began widely using the computer. It may therefore be necessary that the corporate identity design for the franchising business should include not only the use of visual media but new, ultramodern information media as well, departing from the CIP heavily centered on the usual print media. This study, for this reason, separates the identity design for the franchising business from the existing CIP to call it FIP, or Franchise Identity Program, and discusses its concept and details.

  • PDF

A Study on the symbols of bamboo icon in bamboo paintings - Focused on 'bamboo' Ti-hua-shi(題畵詩) in 『Sheng-hua-ji(聲畵集)』 (송대 '대나무' 도상의 상징에 대한 고찰 - 『성화집(聲畵集)』의 '대나무' 제화시를 중심으로 -)

  • Seo, Eun-Sook
    • (The)Study of the Eastern Classic
    • /
    • no.35
    • /
    • pp.471-498
    • /
    • 2009
  • The aim of this study is to see how bamboo paintings developed and what is the iconographical meaning of them through bamboo Ti-hua-shi(poems on paintings) found in Sheng-Hua-Ji, a leading compilation of Ti-hua-shi(poems on paintings) of Song Dynasty. Bamboo paintings give shapes in a simpler and more direct way in drawing, which means bamboo paintings reveal concretely more characteristics of Ti-hua-shi (poems on paintings). Bamboo paintings, which flourished during Northern Song Dynasty, often had the image of the dragon, specially a lying dragon or a winding dragon, which suggests a great man in obscurity. Snow-laden bamboos were also a symbol of a great man, very wise man in Confucian tradition. This shows Confucian ideal examples were embodied through bamboo paintings. Another aspect of bamboo paintings is that bamboo paintings were regarded as a means of self-expression, which identified Confucian sadaebu (scholar-officials) who advocated simplicity and austerity in their life. Contrary to professional painters, who added color and decoration to their paintings, Confucian scholars of Song Dynasty reduced color and embellishment in their bamboo paintings in black-and-white to reveal their own identity, focusing on spirituality rather than the image itself. Therefore, drawing and appreciating bamboo paintings were highly respectable pastime among the literati of Song Dynasty. In short, Bamboo paintings in Song Dynasty were not only a Confucian symbol of a wise and virtuous man but also reflected the taste of Song sadaebu class who thought of bamboo as a symbol for moral and cultural responsibility of Confucian society.

A Study on Counselor's Selfobject Role for Pathological Narcissism (병리적 나르시시즘에 대한 상담자의 자기대상 역할 연구)

  • Yoon, Seok-Min
    • Industry Promotion Research
    • /
    • v.7 no.4
    • /
    • pp.45-52
    • /
    • 2022
  • Based on the Kohut's theory, this study carries out an investigation into the counselor's self object role in pathological narcissism. The theological understandings deal with narcissism, pathology, and self object. Narcissism and pathology can be seen as the failure of the formation of cohesive self. Early infant self, by feeling proper sympathy and love, usually forms integrated cohesive self. In other words, narcissistic personalities, when failing to receive sympathy and accommodation, can result in forming helpless and vulnerable self, which is filled with resentment. In addition, narcissistic characters are afraid of the world and maintain the grandiose image of self to protect themselves from feeling helplessness and emptiness. On the other hand, when they experience accommodation and admiration provided by self object, they can strengthen the image of grandiose self and demonstrate creative abilities as well. An infant remains as a fragmented self, when his or her relationship experience with self object is to be damaged. This study suggests the following conclusions: The counselor's self object role for pathological narcissism should be sympathetic self object so that the counselee will be able to form his or her own healthy cohesive self. Additionally, self object should play a kind role to guide infant desires for ideal models, which eventually help infants to pursue healthy ideas and maintain early states of narcissistic balances.

Optimization of Dual Layer Phoswich Detector for Small Animal PET using Monte Carlo Simulation

  • Y.H. Chung;Park, Y.;G. Cho;Y.S. Choe;Lee, K.H.;Kim, S.E.;Kim, B.T.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.44-44
    • /
    • 2003
  • As a basic measurement tool in the areas of animal models of human disease, gene expression and therapy, and drug discovery and development, small animal PET imaging is being used increasingly. An ideal small animal PET should have high sensitivity and high and uniform resolution across the field of view to achieve high image quality. However, the combination of long narrow pixellated crystal array and small ring diameter of small animal PET leads to the degradation of spatial resolution for the source located at off center. This degradation of resolution can be improved by determining the depth of interaction (DOI) in the crystal and by taking into account the information in sorting the coincident events. Among a number of 001 identification schemes, dual layer phsowich detector has been widely investigated by many research groups due to its practicability and effectiveness on extracting DOI information. However, the effects of each crystal length composing dual layer phoswich detector on DOI measurements and image qualities were not fully characterized. In order to minimize the DOI effect, the length of each layer of phoswich detector should be optimized. The aim of this study was to perform simulations using a simulation tool, GATE to design the optimum lengths of crystals composing a dual layer phoswich detector. The simulated small PET system employed LSO front layer LuYAP back layer phoswich detector modules and the module consisted of 8${\times}$8 arrays of dual layer crystals with 2 mm ${\times}$ 2 mm sensitive area coupled to a Hamamatsu R7600 00 M64 PSPMT. Sensitivities and variation of radial resolutions were simulated by varying the length of LSO front layer from 0 to 10 mm while the total length (LSO + LuYAP) was fixed to 20 mm for 10 cm diameter ring scanner. The radial resolution uniformity was markedly improved by using DOI information. There existed the optimal lengths of crystal layers to minimize the variation of radial resolutions. In 10 cm ring scanner configuration, the radial resolution was kept below 3.4 mm over 8 cm FOV while the sensitivity was higher than 7.4% for LSO 5 mm : LuYAP 15 mm phoswich detector. In this study, the optimal length of dual layer phoswich detector was derived to achieve high and uniform radial resolution.

  • PDF

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Reviewing the Concept of Gender Equality and Femininity in Daesoon Thought: Focusing on Meritorious Deeds and Implementing a Practice on the Based on the Resolution of Grievances for Women (대순사상의 남녀평등이념과 여성성 재조명 - 여성해원의 원리로 본 공덕과 실천을 중심으로 -)

  • Park, Min-mi;Hwang, Hee-yeon;Park, Yong-cheol
    • Journal of the Daesoon Academy of Sciences
    • /
    • v.29
    • /
    • pp.209-239
    • /
    • 2017
  • This study focuses on reviewing the concepts, roles, meanings, and values ascribed to females and femininity as observable in Daesoon thought and in Feminist theory. Especially with regards to the process of achieving gender equality through the resolution of grievance for females in Daesoon thought, the study draws positive and desirable roles within this practice by specifically examining good deeds performed by females and practical roles that females play. By doing so, this study finds a way to go from the world of mutual contention to the world of resolving grievances that have arisen due to the oppression of yin and the encouragement of yang. First wave feminism can be summarized as the inclination for equality. In Daesoon thought concerning this and from standpoint of females, the most ideal image of woman is one of a female Perfected Being who is unified with Dao and has thereby achieved perfection of her humanity apart from gender. In the Later World (Hucheon), people can get results based on their hard work regardless of gender. The enlightenment of Dao is such that it is not important to distinguish between males and females. Both of them can be 'unified with dao'. Therefore, despite the similarity, the concepts of equality in first wave feminism and the resolution of grievance for women have differences in terms of their ideal vision of equality. The representative claim in second wave feminism is 'consideration' and, in this context, 'consideration' has pronounced feminine characteristics. In Daesoon thought, this sense of 'consideration' is related to the concept of 'Jamojijeong', a term that refers to motherly affection. However, it is not simply a virtue of females and mothers, but rather the value of 'Yin (pronounced in Sino-Korean as 'Eum')' called 'Eumdeok (hidden virtue)'. Jamojijeong means that people should behave in a modest way and this helps them achieve their aims. It is also closely related with 'femininity' in the sense of Eum. One of processes spreading it socially is to propagate virtue (Podeok) and if harmony is achieved through it, then 'right yin and right yang' emerge as the precondition by which Pyeong Do (Pacification of Tao) can be realized. Furthermore, because the aspect of Pyeong is a cosmic process, it has distinct differences from the social aims of feminism and the worldly aims of other numerous ideologies. In proceeding from the Former World (Seoncheon), an era of mutual contention, to the Later World, an era of mutual beneficence, it is essential to emphasize the connection between 'harmony (Hwa)' and 'propagating virtue' as the starting point from which the perspective of Daesoon thought aiming at the principle of 'Pyeong' and 'Hwa' emerges. Herein one can discover that the realization of Daesoon thought is based on the vitalization of the feminine value of 'Jamojijeong'.