• Title/Summary/Keyword: Ice storage

검색결과 299건 처리시간 0.023초

축열조를 이용한 냉매과냉각 시스템의 전력수요관리 효과에 대한 연구 (A Study on the DSM Effect of a Refrigerant-Subcooling Refrigeration System with an Ice Storage Tank)

  • 김정배;이은지;이동원
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.845-851
    • /
    • 2010
  • This study was experimentally performed to find the effects of refrigerant subcooling in the refrigeration system and to propose how to get the efficient use of energy. A refrigerant-subcooling refrigeration system consisted of a typical single vapor-compression refrigeration cycle, a subcooler, and an ice storage tank. The degree of subcooling at the exit of the condenser can be increased by the heat transfer between the subcooler and the ice storage tank. The cold heat in the ice storage tank was stored by using the refrigeration cycle during night time and then used to absorb the heat from the subcooler during daytime. The cooling capacity and COP of this system were higher than those of the conventional system due to the increase in the degree of subcooling. Typically, the refrigerant-subcooling system showed superior performance to the conventional refrigeration system and would also contribute to load leveling.

축냉시스템을 이용한 냉매과냉각형 냉동시스템의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of a Refrigerant-Subcooling Refrigeration System with an Ice Storage Tank)

  • 이은지;이동원;김용찬
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.369-374
    • /
    • 2010
  • A refrigerant-subcooling refrigeration system consisted of a typical single vapor-compression refrigeration cycle, a subcooler, and an ice storage tank. The degree of subcooling at the exit of the condenser can be increased by the heat exchange between the subcooler and the ice storage tank. The cold heat in the ice storage tank was stored by using the refrigeration cycle during night time and then used to absorb the heat from the subcooler during daytime. The performance of the refrigerant-subcooling refrigeration system was measured by varying the degree of subcooling. In addition, the performance characteristics of the present system were compared with those of a conventional refrigeration system. The mass flow rate of the present system was higher than that of the conventional system due to the increase in the degree of subcooling. Generally, the refrigerant-subcooling system showed superior performance to the conventional refrigeration system.

과냉각을 동반한 동결과정의 수치해석 (Numerical Analysis for Cooling and Freezing Processes with Subcooling)

  • 윤정인;김재돌;김성규
    • 설비공학논문집
    • /
    • 제8권4호
    • /
    • pp.451-462
    • /
    • 1996
  • In this study, which focuses on ice storage, a fundamental study in cooling and solidification was performed, including the interesting phenomena of density inversion, supercooling and dendritic ice. A numerical study was performed for natural convection and ice formation considering existence of subcooling and dendritic ice were analyzed numerically by using finite difference method and boundary fixing method. In the mesh, the solid fraction was introduced with adding as a term to the energy conservation equation. A flow in the dendrite was modelled as a flow in a porous medium, and the momentum conservation equation was modified to incorporate resistance forces involved in flows through porous media. A numerical solution of the time dependencies of dendrite area and dense ice front was successfully obtained, and the numerical results were good agreement with experimental results. Based on this methodology, a discussion was made of phenomena and characteristics of cooling and freezing processes under various conditions.

  • PDF

역전 유동층 내의 유동해석 및 슬러리아이스 생성에 관한 연구 (Flow pattern analysis and a study on formation of slurry ice in the reversing flow)

  • 오철;최영규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 전기공동학술대회 논문집
    • /
    • pp.202-202
    • /
    • 2011
  • Thermal energy storage(TES) cooling system using cheaper electricity of off-peak time has been applied to relief a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type thermal energy storage cooling system is one kind of more efficient ice-thermal energy storage cooling system than Ice-on-Coil type or Encapsulated type TES cooling system, even though, which are more popular TES system. This study is experimented to observe flow pattern and formation of slurry ice in reversing flow to improve efficiency of heat transfer between fluid and freezing tube.

  • PDF

극저온 지하저장고 주변 ice ring 생성 모델링을 위한 열-수리 해석 (Simulation of Ice Ring Formation around Cryogenic Underground Storage Cavern using Hydro-Thermal Coupling Method)

  • 정용복;박찬;정소걸;정우철;김호영
    • 터널과지하공간
    • /
    • 제16권3호
    • /
    • pp.241-250
    • /
    • 2006
  • LNG지하저장 핵심기술 중 하나인 ice ring 형성을 열-수리 역학 해석을 통해 분석하였다. ice ring은 극저온물질의 누출에 대한 이차방벽 역할과 지하수의 저장공동 침투에 대한 일차방벽역할을 수행한다. 따라서 ice ring의 두께와 위치는 콘크리트와 PU foam 및 멤브레인으로 구성된 일차방호재의 무결성 유지에 있어서 핵심인자가 된다. 수치해석을 통해 이러한 ice ring의 위치와 두께를 추정하였으며 온도와 지하수위 결과를 계측치와 비교하였다. 수치해석결과는 PU foam 열전도도의 온도의존성과 지하수의 상변화를 고려한 경우 파일럿 공동에서 측정한 계측치와 잘 일치하였다. 본 논문에서 제시한 수치해석 기법은 실규모 저장시설의 설계에 있어서 ice ring 형성을 모델링하는 데에 바로 사용될 수 있을 것으로 판단된다.

직사각형 휜이 부착된 관외착빙형 빙축열조에서 응고과정시 열전달 특성에 관한 연구 (An experimental study on heat transfer characteristics in the ice storage system of ice-on-coil type with rectangular finned tube during freezing process)

  • 권혁용;고재윤;정백영;임장순
    • 태양에너지
    • /
    • 제20권4호
    • /
    • pp.61-67
    • /
    • 2000
  • The purpose of this study is to improve heat transfer by attaching rectangular fins to tube. Experiments were carried out under the following conditions - Aspect ratio$(W_f/R_f)$ is 0.7, 1.2 and 1.8. Temperature conversion between high and low positions of water in the thermal storage appeared because maximum density point of water is about $4^{\circ}C$ and inlet direction of working fluid influenced conductive heat transfer Compared with the unfinned tube(bare tube), the rectangular tube increased the ice thermal storage energy and the ice thermal storage energy was increased as aspect ratio was increased.

  • PDF

여름철 고온 환경 조건에서 참외(Cucumis melo var. makuwa)의 저장 중 선도유지를 위한 아이스 팩 처리 포장 박스 적용 연구 (Effect of the ice pack treatment in the corrugated box for improving the storage quality of the oriental melon (Cucumis melo var. makuwa) at high temperature conditions during summer)

  • 최우석;정대성;이윤석
    • 한국식품저장유통학회지
    • /
    • 제21권1호
    • /
    • pp.25-33
    • /
    • 2014
  • 본 연구는 저장 중 참외(Cucumis melo var. makuwa)의 품질 개선 효과를 보기 위하여 일반 골판지 박스로 포장한 무처리 대조구, 아이스 팩을 첨가하여 포장한 시험구, 및 아이스 팩과 알루미늄 코팅 보드로 처리된 박스로 포장한 시험구를 각각 사용하여 실험을 수행하였다. 참외의 품질변화는 $30^{\circ}C$의 저장 조건에서 21일 동안 저장 기간에 따른 참외의 호흡률, 중량감소율, 색도, 경도, 당도, 외관 품질 및 부패과 발생율로 관찰하였다. 저장 21일째 아이스 팩을 첨가한 포장 그리고 아이스 팩 및 알루미늄 코팅 보드를 적용한 포장으로 저장한 참외는 호흡률, 중량감소율, 및 색도, 및 경도 값의 지연으로 뛰어난 선도 유지 효과를 나타냈을 뿐만 아니라 특히 외관품질, 부패과 발생율을 감소시켜 상품성이 유지 효과를 보았다. 반면 참외의 가용성 고형분 함량 값은 각각 다른 형태로 적용한 포장에 의해 큰 영향을 받지 않았다. 아이스 팩과 알루미늄 코팅 보드를 적용한 박스로 포장한 참외는 아이스 팩으로 만 포장한 참외 보다 상대적으로 품질이 개선되는 것을 확인 할 수 있었다. 골판지 박스 내부에 아이스 팩의 적용은 참외 과실이 품고 있는 온도를 낮출 뿐만 아니라 알루미늄 코팅 보드는 외부 고온 환경으로 부터 온도 차단 효과로 포장 내부의 온도 상승에 따른 빠른 품질 변화를 막을 수 있는 역할을 한다고 판단된다.

판형 열교환기를 이용한 과냉각수용액에서 유동과냉도 및 냉각속도가 연속제빙에 미치는 영향 (Influence of the Supercooling Degree and Cooling Rate on a Continuous Ice Formation by a Supercooled Aqueous Solution in Flow Using a Plate Heat Exchanger)

  • 이동규;백종현;홍희기;강채동
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.647-653
    • /
    • 2007
  • In dynamic ice storage system(DISS), ice slurry is formed not only from solution freezing by mechanical removing parts but also supercooled solution. However, in order to perform continuous ice formation in the system without mechanical moving parts, supercooled aqueous solution should be formed stable through cooling heat exchanger and be dissolved uniformly in storage tank. In previous study, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

선도유지제(鮮度維持劑)(Ever-Fresh) 처리(處理)가 붕장어 학꽁치 및 새우의 선도(鮮度) 유지(維持)에 미치는 효과(效果) (Effect of Preservative, Ever-Fresh, on Fish and Shrimp Freshness during Ice Storage)

  • 이응호;강훈이;김정근;양승택;변재형
    • 한국식품영양과학회지
    • /
    • 제2권1호
    • /
    • pp.49-54
    • /
    • 1973
  • Ever-Fresh(주성분(主成分) : kusayate) 처리(處理)가 붕장어, 보리새우, 학꽁치, 빙장중(氷藏中)의 선도유지(鮮度維持)에 미치는 효과(效果)를 실험(實驗)한 결과(結果)를 요약(要約)하면 다음과 같다. 1. K치(値)는 붕장어, 학꽁치 및 보리새우의 사후(死後) 초기(初期)의 신선도(新鮮度)를 판정(判定)하는 좋은 지표(指標)가 될 수 있다. 2. 보리새우의 사후(死後) 초기(初期)의 선도판정(鮮度判定)에는 VB-N도 좋은 지표(指標)가 될 수 있다. 3. Ever-Fresh 처리(處理)는 붕장어, 학꽁치, 보리새우의 빙장(氷藏) 초기(初期)의 선도유지(鮮度維持)에 효과(效果)가 있었다. 4. Ever-Fresh 처리(處理)는 보리새우 빙장(氷藏) 초기(初期)의 산화방지(酸化防止) 효과(效果)가 있었다.

  • PDF

과냉각 축냉시스템을 적용한 쇼케이스의 운전 특성에 대한 실험적 연구 (Experimental Study on The Running Characteristics of Showcase Using Cold Storage System)

  • 이동원;김정배
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.22-28
    • /
    • 2012
  • The purpose of this study was to show how tomaintain high efficiency and to use reasonably when being applied the cold-heat storage systems to the showcase. An experimental study was performed to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that of the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. Using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using the stored cold-heat after being discharged from the air cooling condenser during the day time. Through the experiments, the load transfer rate for the showcase using inverter and ice storage was estimated about 30.0%. And showed that the total power consumption of the showcase with inverter could be reduced about 37% than that of the showcase without inverter.