• Title/Summary/Keyword: Ice load

Search Result 148, Processing Time 0.034 seconds

A Feasibility Study for the Application of the Cold-heat Storage System Considering the Real Operation Status of the Showcase (쇼케이스의 실제 운전상태를 고려한 축냉시스템 적용 가능성 평가 기초 연구)

  • Lee, Dong-Won;Kim, Jeongbae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.52-58
    • /
    • 2012
  • Experimental study was performed to understand the real operation conditions of a showcase working usually in a convenient store and discount store. The purpose of this study was to show the possibility for practical use of cold-heat storage systems being operated for the showcase. To do that, evaporator and condenser temperatures were measured and the compressor electric power consumption were measured simultaneously. To use the ice storage system, the ice making process was typically operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was subcooled using the stored cold-heat after being discharged from the condenser during daytime. So, the cooling performance was increased with the sub-cooling of refrigerant during daytime,hence the actual running time of the compressor could be effectively decreased. Through the experiments, this study showed that the compressor electric power consumption during daytime could be transferred to nighttime for applying the refrigerant sub-cooling. So, for the convenient store, the maximum load transfer rates for each working cooler and showcase were estimated about 31.1% and 19.9% respectively. And for the discount store, the maximum load transfer rates for each refrigeration and freezing showcase were estimated about 34.1% and 49.0% respectively.

Development of MK $III^{TM}$ Type Large Arctic LNG Carrier

  • Suh, Yong-Suk;Jang, Ki-Bok;Ito, Hisashi;Park, Seung-Mun;Chung, Sung-Wook;Han, Sung-Yong
    • Journal of Ship and Ocean Technology
    • /
    • v.11 no.3
    • /
    • pp.24-38
    • /
    • 2007
  • It is a very challenging work to design large Arctic LNG carrier, since LNG carrier requires high reliability for the structural safety and the environment of Arctic region is known to be very severe. Therefore, special attention should be paid for the verifying the structural safety of LNG career particularly with regard to LNG leakage. In this paper, the safety of the hull structure and cargo containment system of 208K MK $III^{TM}$ type LNG carriers with Arc4 is investigated based on the direct calculation of ice loads as well as wave loads. From the whole investigation, it is clear that the developed vessel - 208K MK $III^{TM}$ type LNG carrier with RMRS Ice class Arc4 - has enough strength and is safe to be operated in Arctic region.

An Evaluation of Chiller Control Strategy in Ice Storage System for Cost-Saving Operation (운전비 절감을 위한 빙축열시스템 냉동기 운전기법 평가)

  • Lee, Kyoung-Ho;Choi, Byoung-Youn;Lee, Sang-Ryoul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2008
  • This paper presents simulated and experimental test results of optimal control algorithm for an encapsulated ice thermal storage system with full capacity chiller operation. The algorithm finds an optimal combination of a chiller and/or a storage tank operation for the minimum total operation cost through a cycle of charging and discharging. Dynamic programming is used to find the optimal control schedule. The conventional control strategy of chiller-priority is the baseline case for comparing with the optimal control strategy through simulation and experimental test. Simulation shows that operating cost for the optimal control with chiller on-off operation is not so different from that with chiller part load capacity control. As a result from the experimental test, the optimal control operation according to the simulated operation schedule showed about 14 % of cost saving compared with the chiller-priority control.

Vibration control for serviceability enhancement of offshore platforms against environmental loadings

  • Lin, Chih-Shiuan;Liu, Feifei;Zhang, Jigang;Wang, Jer-Fu;Lin, Chi-Chang
    • Smart Structures and Systems
    • /
    • v.24 no.3
    • /
    • pp.403-414
    • /
    • 2019
  • Offshore drilling has become a key process for obtaining oil. Offshore platforms have many applications, including oil exploration and production, navigation, ship loading and unloading, and bridge and causeway support. However, vibration problems caused by severe environmental loads, such as ice, wave, wind, and seismic loads, threaten the functionality of platform facilities and the comfort of workers. These concerns may result in piping failures, unsatisfactory equipment reliability, and safety concerns. Therefore, the vibration control of offshore platforms is essential for assuring structural safety, equipment functionality, and human comfort. In this study, an optimal multiple tuned mass damper (MTMD) system was proposed to mitigate the excessive vibration of a three-dimensional offshore platform under ice and earthquake loadings. The MTMD system was designed to control the first few dominant coupled modes. The optimal placement and system parameters of the MTMD are determined based on controlled modal properties. Numerical simulation results show that the proposed MTMD system can effectively reduce the displacement and acceleration responses of the offshore platform, thus improving safety and serviceability. Moreover, this study proposes an optimal design procedure for the MTMD system to determine the optimal location, moving direction, and system parameters of each unit of the tuned mass damper.

Transient Torsional Vibration Analysis of Ice-class Propulsion Shafting System Driven by Electric Motor (전기 모터 구동 대빙급 추진 시스템의 과도 비틀림 진동 분석)

  • Barro, Ronald D.;Lee, Don Chool
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.9
    • /
    • pp.667-674
    • /
    • 2014
  • A ship's propulsion shafting system is subjected to varying magnitudes of intermittent loadings that pose great risks such as failure. Consequently, the dynamic characteristic of a propulsion shafting system must be designed to withstand the resonance that occurs during operation. This resonance results from hydrodynamic interaction between the propeller and fluid. For ice-class vessels, this interaction takes place between the propeller and ice. Producing load- and resonance-induced stresses, the propeller-ice interaction is the primary source of excitation, making it a major focus in the design requirements of propulsion shafting systems. This paper examines the transient torsional vibration response of the propulsion shafting system of an ice-class research vessel. The propulsion train is composed of an electric motor, flexible coupling, spherical gears, and a propeller configuration. In this paper, the theoretical analysis of transient torsional vibration and propeller-ice interaction loading is first discussed, followed by an explanation of the actual transient torsional vibration measurements. Measurement data for the analysis were compared with an applied estimation factor for the propulsion shafting design torque limit, and they were evaluated using an existing international standard. Addressing the transient torsional vibration of a propulsion shafting system with an electric motor, this paper also illustrates the influence of flexible coupling stiffness design on resulting resonance. Lastly, the paper concludes with a proposal to further study the existence of negative torque on a gear train and its overall effect on propulsion shafting systems.

Ice Melting Capacity Evaluation of Applicable Materials of De-icing Fluid for High Speed Railway Rolling Stock (고속철도차량용 제빙액으로의 적용가능물질에 대한 융빙성능 평가)

  • Park, Gyoung-Won;Lee, Jun-Ku;Lee, Hong-Ki
    • Applied Chemistry for Engineering
    • /
    • v.30 no.3
    • /
    • pp.384-388
    • /
    • 2019
  • In winter season, the snow and ice accretion on the bottom of the high speed railway rolling stock and boogie part has fallen at a high speed from the ballast section (gravel section for the transmission of the rolling stock load received by sleepers and fixing sleepers), causing the gravel to be scattered, thereby damaging the railway rolling stock structures and facilities. In order to solve these problems, the gravel scattering prevention net, manual de-icing, and movable hot air machine were used, but their efficiency was low. For the more efficient de-icing than ever before, an optimum material for de-icing fluid for high speed railway rolling stock was developed by evaluating the ice melting capacity, kinematic viscosity, evaporation of the material used as a chemical de-icing fluid. Four kinds of organic acid salts (sodium formate, sodium acetate, potassium formate and potassium acetate) and two different alcohols (propylene glycol, glycerol) were used as evaluation materials. Potassium formate, potassium acetate, and propylene glycol had similar ice melting capacities in the indoor test, but the propylene glycol showed the best ice melting capacity in spraying the system simulation test. This is because the kinematic viscosity of propylene glycol was 2.989029 St, which is higher than those of other materials therefore, it could stay longer on the ice and de-icing. In addition, potassium formate and potassium acetate were difficult to be used since the crystals precipitated and adversely affected the appearance of the rolling stock. The propylene glycol is the most optimum as an de-icing fluid for the high speed railway rolling stock.

The Study on Intelligent Cooling Load Forecast of Ice-storage System (빙축열 시스템의 지능형 냉방부하예측에 관한 연구)

  • Koh, Taek-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1539-1540
    • /
    • 2008
  • 운전자의 경험과 판단에 전적으로 의존하는 빙축열 시스템의 기존 운전방식에서는 운전자의 그릇된 판단과 미숙한 운전으로 인해 과잉 축열이나 냉방공급량 부족현상이 자주 초래된다. 본 논문에서는 경제적이고 효율적인 빙축열 시스템의 운용을 위해 다음날의 구간별 온도, 습도와 냉방부하를 예측하는 자기구성퍼지모델 구축방안을 제안한다. 제안된 방법의 성능과 실제 적용가능성을 검증학기 위하여 한국전력 속초 생활연수원을 대상으로 제안된 방법과 신경회로망, 퍼지모델, 선형회귀모델 등을 이용한 기존의 방법을 적용하여 구한 냉방부하, 온도, 습도의 예측정확도를 비교 분석한다.

  • PDF

Analysis of Door Height Difference and Door Flatness Difference of Built-in Side-by-Side Refrigerator Using Cabinet-Door Integrated Model (캐비닛-도어 통합모델을 이용한 빌트인 양문형 냉장고의 도어 상하단차와 앞뒤단차 해석)

  • Lee, Boo-Youn
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.76-83
    • /
    • 2018
  • A cabinet-door integrated finite element model was constructed for a built-in side-by-side refrigerator with an ice dispenser, and its deformation was analyzed using the ANSYS finite element software. As loads, the food load needed to fill in the cabinet and doors and the thermal load occurring during normal operation conditions were taken into consideration. The door height difference (DHD) and door flatness difference (DFD) between the two doors of the freezing and refrigerating compartments were derived. The DHD and DFD under the assembled condition without applied loads satisfied the acceptance criteria specified by the refrigerator manufacturer. It appeared that the food load increases the DFD slightly. The thermal load tends to increase the differences because of the thermal deformation, especially the DFD, of the cabinet and doors.

Cracking of S2 Ice by Spherical Indentation (구형관입에 의한 S2 얼음의 균열)

  • Ko, Sang-Ryong
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.3 s.29
    • /
    • pp.42-48
    • /
    • 1998
  • 구형 관입시험에 의한 얼음의 균열을 연구 하였다. $-10^{circ}C$에서 S2 기둥얼음의 시편(152mm X 152mm X 152mm)에 stainless 강으로 된 구(지름 25.4mm)로 하중을 가하였다. 구형indentor는 얼음 시편의 장축인 기둥방향에 수직으로 하중을 가하였으며 이때 변위율은 0.038mm/s로 하여 단조증가 하중 시험을 하였다. 하중을 가하기 시작하면 indentor 하부에서 crushing 이 발생하고, 하중이 증가함에 따라서 방사선 균열 또는 횡균열이 성장하여 splitting 또는 spallation이 발생하였다. 단조증가 하중 때와 동일한 indentor를 사용하여 하중 및 비하중율 0.5KN/s로 맥박하중을 가할 때 이들 방사선 균열 및 횡 균열이 발생 성장하였다. 첫 맥박 하중의 크기는 1KN으로 하고 그 뒤 계속 이어지는 시험은 맥박 하중의 크기를 증가시킨 뒤 행하였으며 균열 길이는 맥박과 맥박 사이에서 계측 하였다. 기타 취성고체에서 관찰 되었던 것과 같이 방사선 균열 및 측면균열의 길이는 impression 반지름과 하나의 지수법칙이 성립함을 보여주었다.

  • PDF

A Study on the Deicing Performance of Cement Mortar through the Addition of Water-repellent (발수제 혼입에 따른 시멘트 모르타르의 표면 얼음 제거성능에 관한 연구)

  • Kang, Suk-Pyo;Hong, Seong-Uk;In, Byung-Eun;Kim, Sang-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.597-606
    • /
    • 2022
  • This paper examined the effect of water repellent type and addition among various factors on the deicing performance of cement mortar surface according to incorporation. As a result, the compressive strength of the water repellentcement mortar compared to the cement mortar, and the compressive strength of the oligomer-based water repellent mortar was higher than that of the monomer-based water repellent. The contact angle of the water-repellent mortar was increased compared to the additive mortar, and the oligomer water-repellent agent compared to the monomer-based water-repellent. As a result of measuring the ice formation time of cement mortar due to the mixing of the water repellent, the ice formation was delayed until 25 minutes for mortar to which the water repellent was added. the measurement of the ice attachment load mortar without water repellent with water repellentwhen the water repellent was added to mortar, deicing performance was increased.