• 제목/요약/키워드: Ice Thermal-Storage System

검색결과 77건 처리시간 0.024초

수용액의 교반/냉각을 동반한 슬러리 얼음의 빙부착 (Adhesion of Ice Slurry in an Aqueous Solution Cooling with Stirring)

  • 강채동;손권;백종현;홍희기
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1071-1077
    • /
    • 2002
  • Ice adhesion on cooling wall is very important in continuous ice formation. The purpose of the present study is to investigate the possibilities of a three-component aqueous solution as a thermal storage material for the continuous ice formation. By freezing under stirring the solution of 300 mL in a stainless steel vessel which was immersed and cooled in a temperature controlled bath, an ice slurry was formed experimentally with measuring the temperature and stirring load variation. From the experiment, the ice adhesion was suppressed when the supercooling degree decreased and the concentration of aqueous solution increased.

Characteristic of the Formation and Adhesion of Ice on a Cooling Surface by a Stirring Aqueous Solution

  • Kang, Chae-Dong;Seung, Hyun;Hong, Hi-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권3호
    • /
    • pp.110-117
    • /
    • 2006
  • Ice adhesion or cohesion leads to the decrease of the performance of ice making system, especially to dynamic type ice thermal storage system (DISS) which mainly forms ice from the flow of an aqueous solution. The ice adhesion is influenced by various parameters associated with operating or geometric condition. In this study, the influence on an adhesion of ice to the characteristic of cooling surface and to composition of an aqueous solution was fundamentally observed by using batch type cooling device,. a beaker. Three patterns of solution in each beaker were cooled with brine. Moreover, the characteristic of cooling surface on each beaker was distinguished to coating materials. Stirring power as a degree of the ice adhesion was measured. The stirring power to cooling heat transfer rate in each beaker was compared. As a result, the lowest stirring power of 8.9 W with non-adhesion of ice, was shown in the case of the aqueous solution of EG(4) + PG(1.5) + 1,6HD(1.5). in PE coating beaker.

LNG 냉열 에너지의 지역 냉방 시스템에 관한 기반 연구 (A Basic Study on the District Cooling System of LNG Cold Thermal Energy)

  • 김청균
    • 한국가스학회지
    • /
    • 제7권4호
    • /
    • pp.36-43
    • /
    • 2003
  • 본 논문에서는 LNG 냉열 에너지를 활용한 지역 냉방 시스템 가능성에 대해 고찰하고자 한다. 액상의 LNG는 기상의 가스로 변환하는 과정에서 많은 냉열 에너지를 발생한다. 최근에 빙축열을 이용한 건물의 냉방 시스템 구축과 심층수를 이용한 지역 냉방 시스템이 도심지의 기존 사무실 건물이나 대규모 건물의 냉방장치로 도입되고 있는 상황이다. LNG의 냉열 에너지는 기존의 냉매에 의존한 개별 냉방 시스템을 대체하는 새로운 냉열 에너지 공정으로 쾌적한 공간을 제공하는 천연의 대규모 냉각매체로 재사용될 수 있다. 버려지는 냉열 에너지는 낮은 코스트로 운영될 수 있는 중요한 청정 에너지원이기 때문에 냉방 시스템으로 개발되면, 기존의 에어콘 시스템에 견주어 볼 때 공기중에 유해한 오염원의 발생과 환경적으로 유해한 냉매 방출을 대폭적으로 줄일 수 있는 우수한 냉방 시스템이 될 것이다. 따라서, 본 연구에서는 냉열 에너지를 활용한 지역 냉방 시스템에 대한 환경 친화적 기본적 설계 개념, 여러 가지 냉방 시스템 성능에 대한 유익한 기반적 정보를 제공하고자 한다.

  • PDF

계면활성제 첨가수용액의 제빙에 관한 기초연구 (Study on Ice Making Behavior of Water Solution with Surfactant)

  • 박기원
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1175-1183
    • /
    • 2001
  • Recently, a great attention has been paid to the ice thermal storage system for the purpose of energy saving and reduction in peak electrical demand. In the present study, it has been investigated the freezing behavior of several kinds of water solutions with nonionic surfactant. In order to prevent ice blockage in a cooled pipe, the amount and wall adhesion behavior of ice of the test fluids were observed experimentally under different concentration of water solution with surfactant, temperature of cooled wall, and the shear velocity of test fluids. The results showed that the size of ice crystal became smaller at higher shear velocity at wall. And the lowest limit of wall adhesion of ice in water solution with surfactant was found at 230 W/$m^2$ of heat flux.

  • PDF

Melting of Ice on the Heating Plate with Split Fins

  • Hong, Hi-Ki;Kim, Moo-Geun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.1-7
    • /
    • 2001
  • One of the important applications of a contact melting process is a latent thermal energy storage system owing to its high heat flux and small temperature variation. In some previous works, the split fins have been employed in order to enhance the melting rate. In the present work, the direct contact melting was experimentally investigated using an ice as specimen for both split and non-split fins. It was shown that the contact melting by split fins increases the melting rate compared to that of non-split ones.

  • PDF

아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 성능에 관한 실험적 연구 (Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System)

  • 이동원;김정배
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.30-35
    • /
    • 2011
  • 2중관형과 판형 열교환기에 에틸렌 클리콜-물 수용액으로 만들어진 아이스슬러리를 적용하는 경우의 유동 및 열적 특성을 규명하기 위하여 실험을 수행하였다. 아이스슬러리의 질량유속과 얼음 분율은 각각 800에서 3500 kg/$m^2s$과 0에서 25%이었다. 실험을 통해, 압력강하와 열전달율은 질량유속과 얼음 분율에 따라 증가하였다. 그러나 얼음 분율의 효과는 높은 질량유속 영역에서는 크지 않은 것으로 나타났다. 낮은 질량유속에서는 압력강하와 열전달율의 급속한 증가가 질량 유속에 관계되는 것으로 나타났다.

제빙관의 형태변화에 따른 제빙특성 (Ice Making Characteristics According to Changing Shape of Ice Making Tube)

  • 정은호;박기원
    • 설비공학논문집
    • /
    • 제21권5호
    • /
    • pp.291-296
    • /
    • 2009
  • Ice accumulating system patterned ice-an-coil is the way of refrigerating regenerative materials on the surface of copper-tube inserted into the inside of ice-storage. The study experimented to understand ice-an-coil type ice making characteristics according to changing shape of ice making tube. The experiment were carried out under various conditions, that used brine temperature($-l0^{\circ}C$, $-6^{\circ}C$) brine flow rate(l.0m/s, 1.8m/s) and inlet water temperature($6^{\circ}C$, $12^{\circ}C$) etc. Mass of ice per making area increased according to the decrease of the brine temperature and inlet water temperature, but that was increased according to the increase of the brine flow rate. And I set up two hypotheses and compared the capacity of ice-making of the two cases; each had the same thermal area and one had an round-shaped copper tube but the other had an oval-shaped copper tube.

Investigation of amorphous material with ice for cold thermal storage

  • Kim, Jhongkwon;Park, Hyunjun;Bae, Junhyuk;Jeong, Sangkwon;Chang, Daejun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권1호
    • /
    • pp.40-44
    • /
    • 2019
  • This study investigates mixtures of water and cryoprotectant agents (CPAs) to store high-grade cold energy. Although water is an ideal material for a cold thermal storage (CTS) due to its high specific heat, undesirable volume expansion may cause structural stresses during freezing. The volume expansion can be alleviated by adding the CPAs to water. However, the CPA aqueous solutions not only have different thermal properties but also transit to amorphous state different from pure water. Therefore, these characteristics should be considered when using them as material of the CTS. In experiments, glycerol and dimethyl sulfoxide (DMSO) are selected as the candidate CPA. The volume expansion of the solution is measured by an in-situ strain gauge in low temperature region. The specific heat capacity of the solution is also measured by differential scanning calorimetry (DSC). Both the amount of volume expansion and the specific heat capacity of the CPA aqueous solution decrease in the case of higher concentration of CPA. These characteristics should be contemplated to select optimal aqueous solution for CTS for liquid air energy storage system (LAES). The CPA solutions have advantages of having wide temperature range to utilize the latent heat of water and higher sensible heat of the CPA. The CPA solutions which can satisfy the allowable stress of the structure are determined. Consequently, among the CPA solutions investigated, DMSO 20% w/w solution is the most suitable for the CTS.