• Title/Summary/Keyword: IV

Search Result 7,865, Processing Time 0.045 seconds

Assessment of Fire Risk Rating for Wood Species in Fire Event (화재 발생 시 목재 수종의 화재위험성 등급 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.423-430
    • /
    • 2021
  • In order to evaluate the fire risk and fire risk rating of wood for construction materials, this study focused on fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) according to Chung's equations-III and -IV. Western red cedar, needle fir, ash, and maple were used as the specimens. The fire characteristics were investigated using a cone calorimeter (ISO 5660-1) equipment on the specimen. The FPI-III measured after the combustion reaction was 0.86 to 12.77 based on polymethylmethacrylate (PMMA). The FGI-III was found to be 0.63 to 5.26 based on PMMA. The fire rating according to the FRI-IV, which is the fire rating index, was 0.05 to 6.12, and the western red cedar was 122.4 times higher than that of the maple. The fire risk rating according to the FRI-IV increased in the order of maple, ash, needle fir, PMMA and western red cedar. The CO peak concentration of all specimens was measured as 103 to 162 ppm, and it was 2.1 to 3.2 times higher than 50 ppm, the permissible exposure limits of the US occupational safety and health administration. Materials such as western red cedar, which have a low bulk density and contain a large amount of volatile organic substances, have a low FPI-III and a high FGI-III, so they have a high fire risk rating.

Synthesis and Characterization of Homo Binuclear Macrocyclic Complexes of UO2(VI), Th(IV), ZrO(IV) and VO(IV) with Schiff-Bases Derived from Ethylene diamine/Orthophenylene Diamine, Benzilmonohydrazone and Acetyl Acetone

  • Mohapatra, R.K.;Ghosh, S.;Naik, P.;Mishra, S.K.;Mahapatra, A.;Dash, D.C.
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.1
    • /
    • pp.62-67
    • /
    • 2012
  • A series of homo binuclear complexs of the type $[M_2(L/L^')(NO_3)n].mH_2O$, [where $M=U{O_2}^{2+},\;Th^{4+},\;ZrO^{2+}$] and $[(VO)_2(L/L^')(SO_4)_2]{\cdot}2H_2O$, L=1,5,6,9,12,15,16,20 octaaza-7,813,14-tetraphenyl-2,4,17,19-tetramethyl-1,4,6,8,12,14,16,19-docosaoctene (OTTDO) or L'=10:11;21:22-dibenzo-1,5,6,9,12,15,16,20-octaaza-7,813,14-tetraphenyl-2,4,17,19-tetramethyl-1,4,6,8,12,14,16,19-docosaoctene (DOTTOT), n=4 for $U{O_2}^{2+}$, $ZrO^{2+}$ n=8 for $Th^{4+}$ m=1,2,3 respectively, have been synthesized in template method from ethylenediamine/orthophenylene diamine, benzil monohydrazone and acetyl acetone and characterized on the basis of elemental analysis, thermal analysis, molar conductivity, magnetic moment, electronic, infrared, $^1H$-NMR studies. The results indicate that the VO(IV) ion is penta co-ordinated yielding paramagnetic complexes; $UO_2(VI)$, ZrO(IV) ions are hexa co-ordinated where as Th(IV) ion is octa co-ordinated yielding diamagnetic complexes of above composition. The fungi toxicity of the ZrO(IV) and VO(IV) complexes against some fungal pathogen has been studied.

Effect of Observation Window at Peripheral Intravenous Catheter Site on Early Recognition of Infiltration among Hospitalized Children (아동의 말초정맥관 삽입 부위 관찰창 확보가 침윤조기감지에 미치는 효과)

  • Jeong, Ihn Sook;Park, Soon Mi;Park, Kyung Ju
    • Journal of Korean Academy of Nursing
    • /
    • v.46 no.4
    • /
    • pp.534-541
    • /
    • 2016
  • Purpose: The aim of this study was to identify the effect of an observation window (OW) at peripheral intravenous (IV) catheter sites on early detection of IV infiltration among hospitalized children. Methods: This was a retrospective observational study with history control group design. Participants were children who had IV infiltration after peripheral catheterization when hospitalized from January to May, 2014 and January to May, 2015 at a children's hospital located in Yangsan city, Korea. The 193 patients, who were hospitalized from January to May, 2014 formed the control group and did not have OW, and the 167 patients, who were hospitalized from January to May, 2015 formed the window group and had OW. Data were analyzed using ${\chi}^2$-test, independent samples t-test and multiple logistic regression. Results: First stage IV infiltration was 39.5% for the window group and 25.9% for the control group, which was significantly different (p=.007). The likelihood of $2^{nd}$ stage and above IV infiltration decreased by 44% in the window group, which was significantly different (p=.014). Conclusion: OW at the peripheral IV catheter site was found to be an effective measure in early recognition of IV infiltration. Considering the effect of OW, we recommend that nurses should make an OW with transparent dressing during stabilization of the IV catheter site in hospitalized children in clinical settings.

The Investigation of a Novel Indicator System for Trace Determination and Speciation of Selenium in Natural Water Samples by Kinetic Spectrophotometric Detection

  • Gurkan, Ramazan;Ulusoy, Halil Ibrahim
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1907-1914
    • /
    • 2010
  • A novel catalytic kinetic method is proposed for the determination of Se(IV), Se(VI) and total inorganic selenium in water based on the catalytic effect of Se(IV) on the reduction of bromate by p-nitrophenylhydrazine at pH 3.0. The generated bromine, $Br_2$ or $Cl_2$ plus $Br_2$ in 0.1 M NaCl (or NaBr) environment efficiently decolorized Calmagite and the reaction was monitored spectrophotometrically at 523 nm as a function of time. In this indicator reaction, bromide acted as an activator for the catalysis of selenium (IV) and a reducing agent for selenium (VI) at pH 3.0, which allowed the determination of total selenium. The fixed time method was adopted for the determination and speciation of inorganic selenium. Under the optimum conditions, the calibration graph are linear in the range 1 - 35 ${\mu}gL^{-1}$ of Se(IV) for the fixed time method at $25^{\circ}C$. The detection limit based on statistical $3S_{blank}$/m-criterion was 0.215 ${\mu}gL^{-1}$ for the fixed time method (7 min). All of the variables that affect the sensitivity at 523 nm were investigated, and the optimum conditions were established. The interference effect of various cations and anions on the Se (IV) determination was also studied. The selectivity of the selenium determination was greatly improved with the use of the strongly cation exchange resin such as Amberlite IR120 plus. The proposed kinetic method was validated statistically and through recovery studies in natural water samples. The RSDs for ten replicate measurements of 5, 15 and 25 ${\mu}gL^{-1}$ of Se(IV) and Se(VI) was changed between 2.1 - 4.85%. Analyses of a certified standard reference material (NIST SRM 1643e) for selenium using the fixed-time method showed that the proposed kinetic method has good accuracy. Se(IV), Se(VI) and total inorganic selenium in environmental water samples have been successfully determined by this method after selective reduction of Se(VI) to Se(IV).

Study on Sensory Papillae of Metagonimus yokogawai Cercaria (Metagonimus yokogawai 세르카리아의 감각유두에 관한 연구)

  • 김재진;민득영소진탁
    • Parasites, Hosts and Diseases
    • /
    • v.22 no.1
    • /
    • pp.11-20
    • /
    • 1984
  • A number of studies on the papillae of cercariae of trematodes reported that the papillar patterns (or chaetotaxy) of cercariae might be an excellent method to attain better understanding of the digenetic trematodes (Richard, 1971 ; Short and Cartrett, 1973; Bayssade-Dufour, 1979) . The present study was aimed to determine the number, distribution pattern and structure of the sensory papillae of Metagonimus yokogawai cercariae, and to elucidate the chaetotaxy of this digenetic trematode. M. yokogawai cercariae were pipetted from a vial in which infected snails (Semisulcospira libertina) had been kept for 3 hours. The snails were collected from an endemic area of M. yokogawai, Boseong river in west-southern part of Korea. Observations of papillae were based on light microscopy of those stained with silver nitrate, and on scanning electron microscopy The results are summarized as follows: 1, All papillae observed were uniciliated. 2. Cilia in anterior tip were shorter than the others in other portions. 3. The body papillae were arranged in essentially symmetrical patterns, Total number of the papillae was 126(63 pairs) in average; anterior tip 40(20 pairs), ventral 20(10 pairs), lateral 42(21 pairs), and caudal 8(4 pairs). 4. The chaetotany of M. yokogawai cercaria was: Ci cycle ($3+3C_{I}V,{\;}2+2C_{I}L,{\;}2+3C_{I}D),{\;}C_{II}{\;}cycle(2C_{II}V,{\;}1C_{II}L,{\;}2C_{II}D),{\;}C_{lll}{\;}cycle{\;}(1+lC_{III}V,{\;}1C_{IlI}L),{\;}C_{IV}{\;}cycle{\;}(1C_{IV}V,{\;}IC_{lV}L){\;}in{\;}cephalic{\;}region:{\;}A_I(1A_{IV}V,{\;}1+2A_{I}L,{\;}1A_{I}D),{\;}A_{II}(1A_{II}V,{\;}1+3A_{II}L,{\;}1A_{II}D),{\;}A_{III}(1A_{III}V,{\;}1+1A_{III}L,{\;}1A_{III}D){\;}and{\;}A_{IV}(1A_{IV}V,{\;}2A_{IV}L)$ in antacetabular region: $1M_{I}V{\;}and{\;}2M_{I}L$ in median: $1+1P_{I}L,{\;}1P_{II}L,{\;}1P_{II}D,{\;}1P_{III}L,{\;}1P_{IV}L{\;}and{\;}1P_{IV}D$ in postacetabular region: 2-2-2-2 in caudal region.

  • PDF

Application of Single-Compartment Bacterial Fuel Cell (SCBFC) Using Modified Electrodes with Metal Ions to Wastewater Treatment Reactor

  • PARK , DOO-HYUN;PARK, YONG-KEUN;EUI, CHOI
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.6
    • /
    • pp.1120-1128
    • /
    • 2004
  • The SCBFC was composed of bilayered cathode, the outside of which was modified with $Fe^{3+}$ (graphite-Fe(III) cathode) and the inside of which was porcelain membrane, and of an anode which was modified with $Mn^{4+}$ (graphite­Mn(lV) anode). The graphite-Fe(III), graphite-Mn(IV), and porcelain membrane were designed to have micropores. The outside of the cathode was exposed to the atmosphere and the inside was contacted with porcelain membrane. In all SCBFCS the graphite-Fe(III) was used as a cathode, and graphite-Mn(IV) and normal graphite were used as anodes, for comparison of the function between normal graphite and graphite-Mn(IV) anode. The potential difference between graphite-Mn(IV) anode and graphite-Fe(III) cathode was about 0.3 volt, which is the source for the electron driving force from anode to cathode. In chemical fuel cells composed of the graphite-Mn(IV) anode and graphite-Fe(III) cathode, a current of maximal 13 mA was produced coupled to oxidation of NADH to $NAD^{+}$ the current was not produced in SCBFC with normal graphite anode. When growing and resting cells of E. coli were applied to the SCBFC with graphite-Mn(IV) anode, the electricity production and substrate consumption were 6 to 7 times higher than in the SCBFC with normal graphite anode, and when we applied anaerobic sewage sludge to SCBFC with graphite-Mn(IV) anode, the electricity production and substrate consumption were 3 to 5 times higher than in the SCBFC with normal graphite anode. These results suggest that useful electric energy might possibly be produced from SCBFC without electron mediators, electrode-active bacteria, and extra energy consumption for the aeration of catholyte, but with wastewater as a fuel.