The Effects of the Band Type Foot Drop Device (밴드형 첨족예방기구의 효과와 유용성)

  • Kang Hyun-Sook;Kim Won-Ock;Lee Hya-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.3
    • /
    • pp.391-400
    • /
    • 2000
  • A long-term bed rest results in an inevitable foot drop. Yet preventive device such as a foot board and high-neck tennis shoes, are not widely used. This study was conducted to compare the effects of a pillow-type foot board with that of the band-type device. The band-type device of a resonable price is designed for an effective prevention of foot drop, and the convenience for it use. Among the non-equivalent control group design, foot drop preventive effects, usefulness of the device, as well as its cost effectiveness were examined. The study was carried out for four months from December 1999, and its subject had been patients and nurses of two intensive care units at K medical center in Seoul. According to the study purpose, the data collected were analyzed by $x^2-test$ and t-test. The results are as follow : 1. The ROM of ankle joint is promoted in the experimental group with a band-type device comparing the control group with a pillow type one. Dorsiflexion is particularly increased in the experimental group as compared with the control group, while planterflexion hardly shows any change. 2. The usefulness score of the experimental group nurses using the band-type device (23.97) is higher than that of the control group nurses (18.88). 3. In an aspect of the unit production cost, band-type devices are low-priced compare with pillow-type or other foot board (wooden) or high-neck tennis shoes. In summary, the newly developed band-type device is both useful and preventive for a foot drop. It is also desirable regarding to the production cost and the cost effectiveness. This fact proves that the new anti-foot drop device could be practical both for clinical care and home care. Yet the results were obtained by some subjects, it should be used after a further examination. More effective nursing intervention could be observed throughout general studies, including proper positioning and foot and ankle exercises which are the important variables of the foot drop prevention.

  • PDF

Study on KTX driver assistance terminal's hardware and device development (KTX 운전자지원 단말기의 하드웨어와 장치개발에 대한 연구)

  • Jung, Sung-Youn;Kim, Hyung-In;Kang, Ki-Sok;Kim, Hyun-Sic;Jung, Do-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.498-508
    • /
    • 2008
  • TECA(Terminal Cabin) has train information, fault display, maintenance function and training function for driver, as sub-device of Seoul-Pusan Express train's on-board computerized device. Concerning KTX train's driving, signal driving is required for high speed driving, and it is true that we have difficulty in troubleshooting and acquisition of basic information through long train and one-man driving. Therefore, rapid and correct processing about various information and TECA device for maintenance are indispensable for its utilization. But there is not study example in hardware, maintenance about this device and device development according to new requirements. Therefore, this study will help understanding of driver assistance terminal device's maintenance performance development, describing TECA's basic functions necessary for device development and its requirements. Accordingly, I suppose that this thesis will be utilized to complete specification, necessary for new driver assistance terminal device development.

  • PDF

On-site Evaluation of Rainwater Harvesting Device for Securing Irrigation Water in Small Fields (소규모 밭 관개용수 확보를 위한 소류천 빗물 집수장치의 현장 평가)

  • Choi, Yonghun;Kim, Youngjin;Kim, Minyoung;Jeon, Jonggil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.1
    • /
    • pp.31-36
    • /
    • 2018
  • A rainwater harvesting device was developed for runoff flow harvesting in a small stream or channel and its performance was evaluated in small fields. The rainwater harvesting device has slits on its side of cylindrical volume in 15 cm diameter and 70 cm length, which is designed to increase its water flow harvesting capacity. The maximum collectable water quantity was about 0.0022 ton/sec (130 L/min). Rainwater harvesting device were installed in two locations (P1, P2). P1 is a point for rainfall runoff flow harvesting. P2 is a point for ordinary flow harvesting. During this study, total rainfall depth was 334.5 mm. Runoff of 1,722 ton and 7,984 ton occurred in P1 and P2, and 273 ton and 125 ton were collected by this rainwater harvesting device. Harvesting efficiency was calculated as 15.85 % and 1.57 % in P1 and P2. Clogging of screen filter media in the cylinder due to soil and suspended solids has lowered the harvesting efficiency. However, it was possible to harvest 30 ton/month of rainwater harvesting and it is expected that it will help to solve short-term water shortage.

Design of Spent Fuel Rod Slitting Device of an Actual Proof (실증용 사용후핵연료봉 Slitting 장치 설계)

  • Jung J. H.;Yoon J. S.;Hong D. H.;Kim Y. H.;Jin J. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.05a
    • /
    • pp.109-113
    • /
    • 2004
  • Slitting device is equipment to separate spent fuel of 250 mm rod cut pellets and hull in order to supply required $UO_2$ pellets through the dry pulverizing/mixing device. For development of its device, We have analyzed slitting programs so that the existing device is modified an appropriate scale in the advanced spent fuel conditioning process. The results of the analysis, we added the automatic separation function of pellets and hull, After slitting. Also, we have concentrated on reducing the operation time so that the support and the body of a slitting blade could have been established in the single structure to be easily maintained. It is based on a design and manufacture of a testing device and we have performed an efficiency evaluation. We have analyzed the results of efficiency tests of the slitting device and get the specification of the slitting device. we complete the basic design of the slitting device by using of these data. Therefore, We apply to a basic data when manufacturing a slitting device.

  • PDF

Development and experimental verification of vortex typed nonfilter nonpoint source pollution reduction device (와류형 미필터 비점오염저감장치의 개발과 실험적 검증)

  • Jang, Suk Hwan;Lee, Jae-Kyoung;Lee, Hae-Kwang;Hwang, Sung-Gyu
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.4
    • /
    • pp.265-277
    • /
    • 2019
  • The objective of this study was to develop and verify an effective vortex typed nonfilter nonpoint source pollution reduction device. To verify this pollution reduction device, a total of twelves scenarios (three rainfall intensities${\times}$two states${\times}$two steps) of experiments were conducted using pollutants. First, simulated inflow (rainfall intensity 2.5 mm/hr: $0.00152m^3/s$, rainfall intensity 3.395 mm/hr: $0.00206m^3/s$, rainfall intensity 6.870 mm/hr: $0.00326m^3/s$) was calculated. Second, pollutants (mixture of 25% of four particle sizes) were selected and injected. Third, pollutant removal efficiencies of this device at its initial state and operating states were measured. As a result of analysis based on rainfall intensity, the concentration of pollutants was decreased by the device at initial and operating states at all rainfall intensities. Its pollutant removal efficiency was more than 80%, the standard set by the Ministry of Environment. Its pollutant removal efficiency was gradually increased over time, reaching approximately 90%. Its pollutant removal efficiency was higher in its operating state than that in its initial state. Therefore, nonpoint source pollutants can be effectively removed by this vortex typed nonpoint source pollution reduction device developed in this study.

Development and Evaluation of the Application for Maintenance of Photovoltaic Device(3kW) (주택용 태양광발전설비 유지관리용 애플리케이션 개발)

  • Kim, Jae-Yeob
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.105-112
    • /
    • 2018
  • The purpose of this study is to develop an application that supports a user in the maintenance of small photovoltaic device. To this end, this study analyzed the maintenance status, related regulations and existing application contents in Korea. According to the analysis results, most users did not maintain device for themselves. In addition, the maintenance market has not been activated due to its low profitability. Regulations on the maintenance of photovoltaic device prescribed by the KESCO and Japanese counterpart were analyzed to establish the standards for photovoltaic device inspection, and an application was developed based on the existing applications and research results. In order to evaluate the completeness and satisfaction of the developed application, it surveyed 52 users and 22 experts. The survey results showed that the completeness was calculated to be 90 points, and the level of satisfaction was 93 points on a 100-point scale. Therefore, it is expected that the maintenance application developed in this study will be useful for users to maintain the photovoltaic device.

A Study on the Design Direction of the Panic Device (패닉디바이스 디자인 방향성에 관한 연구)

  • Kang, Soon-Ok;Lim, Bo-Hyeok;Lee, Joo-Won;Lee, Hae-Yeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.209-210
    • /
    • 2023
  • A panic device is a type of door lock that opens when pressed or pushed by the body, so it is an emergency escape device designed to easily open the door and escape in an emergency situation such as fire or earthquake. It is an ideal door handle for an emergency exit. Because many people move quickly and it is easy to use, it is common in Europe and North America, but in Korea, the product is expensive, so it is used on a limited basis in luxury buildings such as hotels, but its use is gradually increasing. East Asian countries such as Korea, China, and Japan mainly prefer the North American type. The design of the penic device used in is a uniform and universal design, and research and development of a new design of the penic device was required to develop a new design type product considering the aesthetics of the building.

  • PDF

A Development of Automation System of Auto-Recognition for Device Modules using Micro-Processing Unit (MPU를 이용한 디바이스 모듈 자동 인식 자동화 시스템의 개발)

  • Lin, Chi-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.5 no.3 s.11
    • /
    • pp.24-28
    • /
    • 2006
  • This paper proposed design and implementation of automation system that recognize device module boards automatically that are connected on main control board. The system of this paper is divided to main board and device module boards, and the main board is designed a board by slot structure. The slot structure is possible a extension for upgrade and addition of board ability. Besides, it is easier a establishment and disjointing because it recognizes automatically a device board. The proposed system in this paper compares with K10S1 PLC. The result shows an advantage of extensibility and ability, and it is reduced expense and period for development.

  • PDF

Evaluation Method of Hairstyling Materials and its Application to Cosmetic Preparations

  • Abe, Hidetoshi;Iida, Ichiro;Someya, Takao
    • Proceedings of the SCSK Conference
    • /
    • 2003.09a
    • /
    • pp.1-12
    • /
    • 2003
  • Instead of sensory evaluation, we designed an evaluation method of the setting function of hairstyling products, based on an original theory focusing on changes in bending stress observed when a load with continuous bending is applied to human hair. Specifically, we developed a device to measure bending stress to quickly and objectively evaluate the condition of human hair, particularly its dynamic properties such as the setting function, following the application of hairstyling products. This device generates a load with continuous bending while applying a pendulum motion to a hair tress, one end of which is anchored. The setting function and holding power of resins of various molecular weight and ionic properties were evaluated using this device. The results demonstrated a close correlation with those obtained by experts' sensory evaluation. The evaluation results of bending stress and holding rate confirmed that the combined use of two different resins could improve the function of setting preparations. Evaluation using this device was able to substitute for sensory evaluation, and offers quick objective evaluation and detection of changes in the holding power of hairstyling products over time. We conclude that evaluation using this device is a promising new method.