• Title/Summary/Keyword: ITS device

Search Result 3,955, Processing Time 0.035 seconds

Real-time urine monitoring system for intensive care patient using optical sensor (광센서를 이용한 실시간 중환자 요량감시 장치)

  • Kim, Jong-Myoung;Lee, Jin-Young;Hong, Joo-Hyun;Lim, Seung-Woon;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.81-85
    • /
    • 2008
  • This paper addressed real-time urine monitoring device for intensive care patients. The device was developed to detect and count each urine drop using optical sensor and calculate the current urine output volume and its hourly rate. In experiment, the water volume scale of drainage bottle was observed and compared with the count of the device so that the volume of each drop was found to vary with the dropping rate per minute. From this measurement, the relationship equation was derived to estimate the total water volume from the drop rate (correlation coefficient : r= 0.99). The developed device could be applied to count patient's urine drop successfully. Therefore, this device can be used to monitor intensive care patient's urine status in real-time.

Various Techniques for Improving of the Reliability of the Wireless Network Design/Optimization Simulation Tool (무선망 설계/최적화 시뮬레이션 툴 의 다양한 신뢰도 향상 기법)

  • Jeon Hyun-Cheol;Ryu Jae-Hyun;Park Sang-Jin;Park Joo-Yeoul;Kim Jung-Chul
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.39-42
    • /
    • 2006
  • There are various analysis functions(including prediction of path loss, analyzing of capacity and coverage, etc.) of simulation tool to design and optimize the mobile communication network. Its reliability absolutely effects the performance of mobile communication network. Especially as the wireless network highly advancing focused on data service, it more needs to research and develop on the standard establishment of reliability of the simulation tool. Also it is important the systematic research how to improve the reliability of simulation tool. In this paper, to give the concrete process and skill about how to improve reliability, we define the kinds of reliability at first. And then we explain the comparison results between real field measurement data and theoretic simulation data.

  • PDF

Inadvertent Complication of a Pipeline Embolization Device for Treatment with Vertebral Artery Dissecting Aneurysm : Distal Tip Fracture of Delivery Wire

  • Park, Jung Soo;Kwak, Hyo Sung;Lee, Jong Myong
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.521-524
    • /
    • 2016
  • Use of the Pipeline embolization device (PED) has increased based on studies about its safety and effectiveness, and new reports that describe perior postprocedural complications are now emerging. We report a rare periprocedural device-related complication that occurred during endovascular treatment with the pipeline embolization device for a dissecting aneurysm on the vertebral artery. A 55-year old woman was admitted due to left medullary infarction, and angiography showed a fusiform dilatation in the left vertebral artery that was suspicious for dissecting aneurysm. Endovascular treatment with PED was planned. Under general anesthesia, the procedure was performed without significant problems and a PED was deployed in an appropriate position. However, in the final step of the procedure, the distal tip of the PED delivery wire became engaged within a small branch of the posterior cerebral artery and fractured. Fortunately, imaging studies after the procedure revealed neither hemorrhagic nor ischemic stroke, and the patient recovered without neurological morbidities except initial symptoms.

Calibration of Parallel Manipulators using a New Measurement Device (새로운 측정장비를 이용한 병렬구조 로봇의 보정에 관한)

  • Rauf, Abdul;Kim, Sung-Gaun;Ryu, Je-Ha
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1494-1499
    • /
    • 2003
  • Kinematic calibration is a process whereby the actual values of geometric parameters are estimated so as to minimize the error in absolute positioning. Measuring all components of Cartesian posture, particularly the orientation, can be difficult. With partial pose measurements, all parameters may not be identifiable. This paper proposes a new device that can be used to identify all kinematic parameters with partial pose measurements. Study is performed for a six degree-of-freedom fully parallel Hexa Slide manipulator. The device, however, is general and can be used for other parallel manipulators. The proposed device consists of a link with U joints on both sides and is equipped with a rotary sensor and a biaxial inclinometer. When attached between the base and the mobile platform, the device restricts the end-effector's motion to five degree-of-freedom and can measure position of the end-effector and one of its rotations. Numerical analyses of the identification Jacobian reveal that all parameters are identifiable. Computer simulations show that the identification is robust for the errors in the initial guess and the measurement noise.

  • PDF

Hydrazine Doped Graphene and Its Stability

  • Song, MinHo;Shin, Somyeong;Kim, Taekwang;Du, Hyewon;Koo, Hyungjun;Kim, Nayoung;Lee, Eunkyu;Cho, Seungmin;Seo, Sunae
    • Applied Science and Convergence Technology
    • /
    • v.23 no.4
    • /
    • pp.192-199
    • /
    • 2014
  • The electronic property of graphene was investigated by hydrazine treatment. Hydrazine ($N_2H_4$) highly increases electron concentrations and up-shifts Fermi level of graphene based on significant shift of Dirac point to the negative gate voltage. We have observed contact resistance and channel length dependent mobility of graphene in the back-gated device after hydrazine monohydrate treatment and continuously monitored electrical characteristics under Nitrogen or air exposure. The contact resistance increases with hydrazine-treated and subsequent Nitrogen-exposed devices and reduces down in successive Air-exposed device to the similar level of pristine one. The channel conductance curve as a function of gate voltage in hole conduction regime keeps analogous value and shape even after Nitrogen/Air exposure specially whereas, in electron conduction regime change rate of conductance along with the level of conductance with gate voltage are decreased. Hydrazine could be utilized as the highly effective donor without degradation of mobility but the stability issue to be solved for future application.

Design of Collective system of Automobile information in Korea (대한민국 표준 개인용 자동차 운행정보 수집 시스템 설계에 대한 연구)

  • Kim, Min-Young;Jang, Jong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.1923-1930
    • /
    • 2012
  • 'No-Automobile driving Day' is one of Special option of Automobile Insurance in Republic of Korea. It option is used a system for collect to automobile driving information. However, Its system gives discomfort to users of this system. A Discomfort of this system to users is the OBD device's(Personal Car Driving Check Device) installation. A frequent installation of this device provides this OBD device's breakage to the users of this system. In this paper, for a solve this problem, studied new system design to supplement the existing system using Smartphone and WPAN(Wireless Personal Area Network).

A Study on Real-Time Lightning Simulation for Smart Device (스마트기기 게임에 적합한 실시간 번개 시뮬레이션 연구)

  • Park, SungBae;Oh, GyuHwan
    • Journal of Korea Game Society
    • /
    • v.13 no.4
    • /
    • pp.35-46
    • /
    • 2013
  • In this paper, we show a real-time lightning simulation for smart device game. Our proposed method uses physically based Dielectric Breakdown Model to similar real world lightning path and we simplify the algorithm for real-time simulation in smart device. In addition, the rendering process can render multiple lightning and can real-time render in smart device. Finally, our lightning can support interactive with user. The simulation method will be effectively useful for a game that needs a real-time simulation as its game element in smart device environment.

Design of a Remote Controller for Dismantling Processes Using Excavator (굴삭기를 이용한 해체 장비용 원격 조종 장치 설계)

  • Kim, Dong-Nam;Oh, Kyeong-Won;Hong, Dae-Hie;Park, Jong-Hyup;Hong, Suk-Hie
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.7
    • /
    • pp.95-102
    • /
    • 2008
  • Since the processes of dismantling are very dangerous, there have been many studies to develop remote operating devices using joystick. In this paper, in order to improve the operability of the dismantling equipment that is usually an excavator, a novel concept of tole-operated device is proposed. Operators who use this device with additional environmental sensing devices can work safely away from the dangerous sites. First, based on the concept design of the remote controller, its workspace is analyzed and the workspace mapping from the device to the excavator is explored. Second, after 7 steps of the excavating processes are defined, the kinematics which deals with the conversion from the 3 dimensional position information of the device to the joint variable information of the backhoe is included in this paper. Lastly, 3D graphical simulation of both remote controller and the backhoe will be shown. This new design of the remote control device tan be easily manufactured and gives the workers very convenient and transparent remote control capability.

A study on the electrical switching properties of oxide metal (산화금속의 전기적 스위칭 특성 연구)

  • Choi, Sung-Jai;Lee, Won-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.3
    • /
    • pp.173-178
    • /
    • 2009
  • We have investigated the electrical properties of oxide metal thin film device. The device has been fabricated top-top electrode structure and its transport properties are measured in order to study the resistance change. Electrical properties with linear voltage sweep on a electrodes are used to show the variation of resistance of oxide metal thin film device. Fabricated oxide metal thin film device with MIM structure is changed from a low conductive Off-state to a high conductive On-state by the external linear voltage sweep. The $Si/SiO_2/MgO$ device is switched from a high resistance state to a low resistance state by forming. Consequently, we believe oxide metal is a promising material for a next-generation nonvolatile memory and other electrical applications.

  • PDF

Development of a Deterioration Diagnostic Device for ZnO Arrester by Leakage Current Detection (누설전류 검출에 의한 ZnO 피뢰기의 열화진단장치 개발)

  • Kim, Jae-Chul;Lee, Bo-Ho;Oh, Jung-Hwan;Lee, Young-Gil;Moon, Sun-Ho;Kim, Young-Chun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.3
    • /
    • pp.184-189
    • /
    • 1999
  • In this paper, we develope a diagnosis device for ZnO arrester by detecting the leakage current in service. To diagnose the deterioration of ZnO arrester, the device detects the total leakage current which flows between an arrester and ground, and analyzes the resistive current(third harmonic current) which is an indicator of deterioration of ZnO arrester. We use the optical cable which can transfer a detected data without a noise, also use a microprocessor for a data storage, processing, and trend analysis. Experiment are executed to verify its performance in laboratory and the results show that the diagnosis device exactly detects the total leakage current and the resistive current, so it can diagnose the deterioration of ZnO arrester. Also the leakage current of ZnO arrester is detected using the developed diagnostic device in field, these results are presented.

  • PDF