• 제목/요약/키워드: ITS device

검색결과 3,927건 처리시간 0.031초

New Material Architecture and Its Process Integration for a-Si TFT Array Manufacturing

  • Song, Jean-Ho;Park, Hong-Sick;Kim, Sang-Gab;Cho, Hong-Je;Jeong, Chang-Oh;Kang, Sung-Chul;Kim, Chi-Woo;Chung, Kyu-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.552-555
    • /
    • 2002
  • In order to achieve higher performance and low cost a-Si TFT-LCD panel, new material architecture and its process integration for a-Si TFT array manufacturing method were developed. Material combination of low resistant dry-etchable metal and new pixel electrode under currently adopted 4 mask process made it possible to get more-simplified manufacturing method and better device performance for the a-Si TFT-LCD application. Proposed 4 mask process architecture with optimized wet etchants and dry etching process was applicable to various devices such as notebook, monitor and TV.

  • PDF

New Graphene Electronic Device Structure for High Ion/Ioff Ratio

  • 정현종
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.112-112
    • /
    • 2012
  • Graphene has been considered as one of the potential post Si-materials due to its high mobility. [1] However, since graphene is semi-conductor with zero band gap, it is difficult to achieve high Ion/Ioff ratio, one of the most important requirements for commercial devices. There have been many attempts to open its band gap for high Ion/Ioff ratio, but most of them end up lowering the mobility. [2-5] Thus, we proposed and demonstrated a new device structure for graphene transistor based on one of the unique properties of graphene for high Ion/Ioff: using this approach, we were able to achieve the ratio over $10^5$. [6] Our device has several major advantages over previously proposed graphene based electronic devices. Since our device does not alter the given properties of graphene, such as opening the band gap, it has no fundamental issues on mobility degradations. In addition, our device is fully compatible with current Si technology and we were able to fabricate the devices with 6 inch wafer scale with CVD (Chemical Vapor Deposition) grown graphene. In this presentation, we will discuss about the details of our graphene device including the device structure and the detailed understanding of working mechanism. We will present device characteristics including I-V curves with $10^5$ on/off ratio. We will also present the performance of an inverter based on our devices. Finally, we will discuss the current issues and their potential solutions.

  • PDF

Make-up of a Simulator having the Same Brake Characteristics as Actual Elevator Emergency Stop Device

  • Nakagawa, Toshiko;Suzuki, Kazuo;Haga, Akira;Hayakawa, Naoya
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권4호
    • /
    • pp.454-459
    • /
    • 2013
  • The authors study a novel type of elevator emergency stop device which enables to soften impact force at an emergency halt. A new structure of emergency stop devices has been already proposed by our laboratory and also its characteristics has been already proposed by our laboratory and also its characteristics has been shown by digital simulations[1]. In order to confirm the actual effects of our proposed emergency stop device, we have made up a simulator having the same characteristics as the conventional emergency stop device to accomplish the experiments from now on. In this paper, this process is introduced.

형상기억합금을 이용한 회전공구 클램핑 장치 구현 (Implementation of the rotating tool clamping device using a shape memory alloy)

  • 정준모;박종권;이동주;신우철
    • 한국공작기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.16-20
    • /
    • 2008
  • This paper presents the construction of micro tool clamping device using a Ni-Ti shape memory alloy(SMA) ring. Clamping force of the device is produced by elastic force of the SMA reverted to its original shape in normal temperature. Phase transformation of the SMA was realized by temperature control using a peltier element. Prototype of the SMA tool clamping device was fabricated and examined its clamping force and clamping/unclamping operation.

소형 스핀들 시스템 적용을 위한 형상기억합금 기반 공구 클램핑 장치의 체결특성 고찰 (Investigation for Clamping Properties of the Tool Clamping Device Based on the Shape Memory Alloy for Application of a Micro Spindle System)

  • 신우철;노승국;박종권;이득우;정준모
    • 한국공작기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.9-14
    • /
    • 2007
  • In this paper, a rotating tool clamping device was developed based on a shape memory alloy(SMA) and its feasibility as a tool holder was experimentally explored. The SMA-based device was able to alter clamping to unclamping through temperature control within 1 second. The means and repeatability(${\sigma}$) of the tool clamping force were 185.5N and 6N respectively and its drifts were less than 3% for an hour. Considering the temperature hysteresis of the SMA-based tool clamping device, it is necessary to heat the SMA ring to around $50^{\circ}C$ after tool change to obtain more clamping force.

모터사이클 운전자 신체보호용 안전장치 개발 프로세스 (A Wearable Safety Device for the Body Protection of Motorcyclists)

  • 장동환
    • 한국기계가공학회지
    • /
    • 제20권1호
    • /
    • pp.25-33
    • /
    • 2021
  • This paper presents the development process for airbag safety devices fitted in motorcyclists' garments. Motorcycle riders often sustain multiple injuries in crashes since rider post-impact kinematics depend on several variables. This study proposes a newly inflatable safety system connected to the motorcycle by a cable. An airbag device with a mechanical triggering system is deployed when the cable detaches from its mounting clip. Airbag filling tests are performed to determine the mixing ratio of compressed gases with the severance of temperature. To estimate the airbag effectiveness to reduce riders' injuries, numerical analysis is performed using the finite element method. A comparative analysis (i.e., with and without the chosen device) was conducted to evaluate its protective efficacy. Prototype garments based on the proposed design have been created and have undergone sled tests. The proposed safety device could also be beneficial in accidents during other sports activities.

Effect of Vibration Suppression Device for GNSS/INS Integrated Navigation System Mounted on Self-Driving Vehicle

  • Park, Dong-Hyuk;Ahn, Sang-Hoon;Won, Jong-Hoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제11권2호
    • /
    • pp.119-126
    • /
    • 2022
  • This paper presents a method to reduce the vibration-induced noise effect of an inertial measurement device mounted on a self-driving vehicle. The inertial sensor used in the GNSS/INS integrated navigation system of a self-driving vehicle is fixed directly on the chassis of vehicle body so that its navigation output is affected by the vibration of the vehicle's engine, resulting in the degradation of the navigational performance. Therefore, these effects must be considered when mounting the inertial sensor. In order to solve this problem, this paper proposes to use an in-house manufactured vibration suppression device and analyzes its impact on reducing the vibration effect. Experimental test results in a static scenario show that the vibration-induced noise effect is more clearly observed in the lateral direction of the vehicle, but can be effectively suppressed by using the proposed vibration suppression device compared to the case without it. In addition, the dynamic positioning test scenario shows the position, speed, and posture errors are reduced to 74%, 67%, and 14% levels, respectively.

공간형 3 자유도 Haptic 메커니즘의 구현 (Implementation of A Spatial 3-DOF Haptic Mechanism)

  • 이재훈;이수강;이병주;이석희;이정헌;김희국
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.312-316
    • /
    • 2004
  • In this study, a spatial 3-dof haptic mechanism is implemented. The implemented mechanism does not employ the gear transmissions as velocity reducers for all three joints but uses wire-based transmissions, thereby it is able to minimize the frictions significantly. Also, by employing the structure of the four-bar mechanism to drive third joint from close to the base, the mechanism is able to minimize the inertia effect from the third actuator very effectively. Its kinematic analysis such as position and velocity analyses are performed first. Then, its operating software development, hardware implementation, and the related interfaces between a PC and the implemented Haptic device are completed. To evaluate its potential and its performance as a haptic device, a experiment generating a virtual constraint in a operational task space is conducted and preliminary results are discussed.

  • PDF

동기 발전기 시스템의 실시간 모니터링 기술 개발 (A Development of Real-time Monitoring Techniques for Synchronous Electric Generator Systems)

  • 조현철
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.182-187
    • /
    • 2017
  • Synchronous generators have been significantly applied in large-scale power plants and its monitoring systems are additionally established to sequentially observe states and outputs. We develop a computer based monitoring device for three-phase synchronous power generators in this paper. First, a test-bed of such generator system is created and then a interface board is constructed to transfer electric signals including the output voltage and the current from generators into a computer system via a data acquisition device. Its RMS(root-mean-square) values are continuously shown on a screen of computer systems and its time-histories graphs are additionally illustrated under a graphic user interface(GUI) mode. Lastly, we carry out real-time experiments using the generator system with the monitoring device to demonstrate its reliability and superiority by comparing results of a generic power analyzer which is well-used in measuring various power systems practically.

KSTAR 저온 및 구조 계측 시스템 운전 결과 (Operation result of the Cryogenic and Mechanical Measurement System for KSTAR)

  • 김영옥;추용;요네가와;방은남;이태구;백설희;홍재식;이상일;박갑래;오영국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.26-30
    • /
    • 2009
  • Korea Superconducting Tokamak Advanced Research(KSTAR) device is composed of 30 superconducting magnets, magnet structure, vacuum vessel, cryostat, current feeder system, and etc. KSTAR device is operated in the cryogenic temperature and high magnetic field. We install about 800 sensors - temperature sensors, stain gages, displacement gages, hall sensors - to monitor the thermal, mechanical, electrical status of KSTAR during operation. As a tremendous numbers of sensors should be installed for monitoring the KSTAR device, the method of effective installation was developed. The sensor test was successfully carried out to check its reliability and its reproduction in the cryogenic temperature. The sensor signal is processed by PXI-based DAQ system and communicated with central control system via machine network and is shown by Operator Interface(OPI) display in the main control room. In order to safely operate the device, any violations of mechanical & superconductive characteristic of the device components were informed to its operation system & operator. If the monitored values exceed the pre-set values, the protective action should be taken against the possible damage. In this paper, the system composition, operation criteria, operation result were presented.