• Title/Summary/Keyword: ITS

Search Result 145,424, Processing Time 0.137 seconds

Characterization of Cellulases from Schizophyllum commune for Hydrolysis of Cellulosic Biomass (Schizophyllum commune에 의한 Cellulase 생산 및 섬유소계 바이오매스의 당화를 위한 효소적 특성)

  • Kim, Hyun-Jung;Kim, Yoon-Hee;Cho, Moon-Jung;Shin, Keum;Lee, Dong-Heub;Kim, Tae-Jong;Kim, Yeong-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.547-560
    • /
    • 2010
  • The optimum culture condition of Schizophyllum commune for the cellulase production and its enzymatic characteristics for saccharification of cellulosic biomass were analyzed. S. commune secrets ${\beta}$-1,4-xylosidase (BXL) and cellulases, including endo-${\beta}$-1,4-glucanase (EG), cellobiohydrolase (CBH), and ${\beta}$-glucosidase (BGL). The optimum reaction temperature for all cellulases was $50^{\circ}C$ and the thermostable range was $30{\sim}40^{\circ}C$C. The optimum reaction pH for all cellulases was 5.5 in a range of temperature from $0^{\circ}C$ to $55^{\circ}C$. The best nutritions for the cellulase production of S. commune among tested nutrients were 2% cellulose for the carbon source and corn steep liquor or peptone/yeast extract for the nitrogen source without vitamins. The environmental culture condition for the cellulase production was 5.5~6.0 for pH at $25{\sim}30^{\circ}C$. The enzyme activities of EG, BGL, CBH, and BXL were 3670.5, 631.9, 398.5, and 15.2 U/$m{\ell}$, respectively, after concentration forty times from the culture broth of S. commune which was grown at the optimized culture condition. Alternative filter paper unit assay showed 11 FPU/$m{\ell}$ enzyme activity. The saccharification tests using cellulase of S. commune showed the low saccharification rate on tested hardwoods but a high value of 50.5% on cellulose, respectively. The saccharification rate (50.5%) of cellulose by cellulase produced in this work is higher than 45.7% in the commercial enzyme (Celluclast 1.5L, 30 FPU/g, glucan).

Development of Heat Exchanger for Fermentation Heat Utilization from Waste Woody Biomass (목질계 폐바이오메스의 발효열이용 열교환기의 개발)

  • Cho, Nam-Seok;Choi, Tae-Ho;Kim, Hong-Eun;Lee, Suk-Ho;Lee, Chung-Koo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.94-104
    • /
    • 2009
  • It is urgently required to develop the production of fermentation-heat energy from the waste agricultural and forest biomass and its effective heat exchanging system for the supply of warm water to rural households and greenhouses. In this study 3 helical-type and 1 plate-type heat exchangers using 3 different waste biomasses [e.g. hardwood (HW) sawdust (100%), softwood (SW) sawdust : HW sawdust (50 : 50) and HW sawdust : grass (90 : 10)] were applied in order to find out the best heat recovery system. The heat exchanger was basically considered to improve the overall heat recovery efficiency, to minimize heat loss and to simplify manufacturing, assembling and breaking up the fermenting beds. The helical-type heat exchanger (HX-H3) installed in fermenting bed of HW sawdust : grass (90 : 10) showed relatively higher temperature profiles, in particular mid- and upper-parts than lower and surface parts during 45-day fermentation process. The maximum temperature was ranged from $40^{\circ}C$ to $65^{\circ}C$ with average $60^{\circ}C$. The water temperature of tank outlet was ranged to $33{\sim}48^{\circ}C$ during whole measuring periods. By the way plate-type one (HX-P) installed in same biomass compositional fermenting bed showed $64.5{\sim}76.5^{\circ}C$ at center part, and $43{\sim}56^{\circ}C$ and $42{\sim}58^{\circ}C$, water tank and tank outlet temperatures, respectively, during 100 day measurement. It could be concluded that the plate-type heat exchanger (HX-P) provides not only the effective heating for the rural households and greenhouses, but also having the best heat recovery performance, easy manufacturing, assembling and breaking up the systems.

The Clinical Comparision of Amrinone and Dopamine after Open Heart Surgery (개심술후 암리논과 도파민의 효과에 대한 임상 비교)

  • 이성호;이현재
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.191-198
    • /
    • 1996
  • Amrinone is a non-glycosidic, non-adrenergic positive inotropic agent with peripheral and coronary vasodilator effect. It inhibits phosphodiesterase F-III, the cardiac cyclic-AMP specific phosphodiesterase, selectively and potently. In this study, the effects of IV administered amrinone and dopamine were compared in 40 patients who had open heart surgery. Amrinone was administered as a bolus of 1 5~2mglkg for several minutes, followed by continuous infusion at 5~1 Oug/kg/min. The hemodynamic measurements including heart rate, systolic and diastolic pressure, cardiac index, pulmonary wedge pressure, and systemic vascular resistance were recorded immediately for 12~24 hours awl 7th day following operation. In amrinone group, cardiac index increased from 3.73$\pm$1.39 L/min/m2 to 5.44$\pm$2.65 L/min/m2 at the time of posterative 48 hours (n=20, p< 0.05). The decrease in systemic vascular resistance from 1237.5 $\pm$ 637.7 dyne/sec/cm2 to 1000.8 $\pm$ 608.5 dyne/sec/cm2(p<0.05). In Dopamine group, the heart rate increased from 92.1 $\pm$ 13.0/min to 101.0 $\pm$ 13.1/min and the cardiac index decreased from 3.40 $\pm$ 0.50 L/min/m2 to 2.53 $\pm$ 1.15 L/min/m2 at the time of postoperative 12 hours(p<0.05). Systemic vascular resistance increased from 1058.5 $\pm$ 234.6 dyne/sec/cm2 to 1979.7 $\pm$ 759.2 dynelsec/cm2 The comparison of the hemodynamic effects of amrinone and dopamine, both drugs improved cardiac performance. But the administration of amrinone results in a higher cardiac index, diastolic blood pressure and lower systemic vascular resistance than those achieved with dopamine (p<0.05). The uniqueness of the action of amrinone on the heart and its sustained hemodynamic effect suggest it has clinical promise, pos operative care of cardiac surgery

  • PDF

Surgical Treatment of Ventricular Tachycardia After Total Correction of Tetralogy of Fallot- Report of a case (TOF 완전교정술후 발생한 심실빈맥의 외과적 절제술 -치험1례보고-)

  • 장병철;김정택
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.639-645
    • /
    • 1996
  • A 14-year-old male patient with previous surgical repair of tetralogy of Fallot was admitted with hemodynamically significant ventricular tachycardia (VT). On preoperative electrophysiologic study (EPS), the morphology of documented VT was RBBB of vertical axis with 320 msec cycle length. The endocardial mapping during VT delineated the origin of VT at right ventricular outflow tract (RVOT), where the patch was attached. The clinical VT had a clockwise reentry circuit around the patch with the earliest activation at the same site seen during the preoperative EPS. The previously placed right ventricular outflow patch and fibrous tissue were removed. During a postoperative EPS, it was no longer possible to induce the VT. Ventricular tachycardia following repair of tetralogy of Fallot seen in this patient was caused by a macro-reentry around the right ventricular outflow patch. We were able to ablate the VT with the aid of a detailed mapping of its epicardial activation sequence.

  • PDF

Protective Effects of Adenosine-enriched Cardioplegic Solution in Ischemic Myocardium (Adenosine을 함유한 심정지액의 심근보호 효과)

  • 이호철;정태은
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.199-207
    • /
    • 1996
  • Ischemic myocardial damage is inevitable to cardiac surgery. Myocardial damage after initiation of reperfusion through the coronary arteries is one of the most important determinants of a successful surgery. Adenosine is a potent vasodilator, and is also known to induce rapid cardioplegic arrest by its property of antagonizing cardiac calcium channels and activating the potassium channel. Thus, we initiated this study with adenosine to improve postischemic recovery in the isolated rat heart. We tested the hypothesis that adenosine could be more effective than potassium in inducing rapid cardiac arrest and enhancing postischemlc hemodynamic recovery. Isolated rat hearts, connected to the Langendorff appratus, were perfused with Krebs-Henseleit buffer and all hearts were subjected to arrest for 60 minutes. Three groups of hearts were studied according to the composition of cardioplegic solutions : Group A (n=10), adenosine 10mmo1/L+potassium free modified St. Thomas cardioplegia : Group B (n=10), adenosine 400mo1/L+S1. Thomas cardioplegia:Group C(control, n=10), St. Thomas cardioplegia. Adenosine-treated groups (group A & B) resulted in more rapid cardiac arrest than control group (C) (p< 0.01). There was greater improvement in recovery of coronary blood flow at 20 and 30 minutes of reperfusion in group A and at 20 minutes in group B when compared with control group(p<0.01). Recovery of systolic blood pressure at 10 minutes after reperfusion in group A and B was significantly superior to that in group C (p<0.01). Recovery of dp/dt at 10 minute after reperfusion in group A was also significantly superior to group C (p<0.05). Group A and B showed better recovery rates than control group in aortic blood flow, cardiac output, and heart rate, but there were no statistical differences. CPK levels of coronary flow in group A were significantly low (p< 0.01). We concluded that adenosine-enriched cardioplegic solutions have better effects on rapid cardiac arrest and postischemic recovery when compared with potassium cardioplegia.

  • PDF

Clinical Application of Compressed Spectral Array During Deep Hypothermia (초저체온하 대동맥수술 환자에서 완전 순환차단의 안전한 체온 및 기간에 대한 연구 - 뇌파 Compressed Spectral Array의 임상적 응용 -)

  • 장병철;유선국
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.752-759
    • /
    • 1997
  • Profound hypothermia protects . cerebral function during total circulatory arrest(TCA) in the surgical treatment of a variety of cardiac and aortic diseases. Despite its importance, there is no ideal technique to monitor the brain injury from ischemia. Since 1994, we have developed compressed spectral array(CSA) of electroencephalography(EEG) and monitored cerebral activity to reduce ischemic injury. The purposes of this study are to analyse the efficacy of CSA and to establish objective criteria to consistently identify the safe level of temperature and arrest time. We studied 6 patients with aortic dissection(AD, n=3) or aortic arch aneurysm(n=3, ruptured in 2). Body temperatures from rectum and esophagus and the EEG were monitored continuously during cooling and rewarming period. TCA with cerebral ischemia was performed in 3 patients and TCA with selective cerebral perfusion was performed in 3 patients. Total ischemic time was 30, 36 and 56 minutes respectively for TCA group and selective perfusion time was 41, 56 and 92 minutes respectively for selective perfusion group. The rectal temperatures for flat EEG were between 16.1 and 22. $1^{\circ}C$ (mean: 18.4 $\pm$ 2.0): the esophageal temperatures between 12.7 and $16.4^{\circ}C$ (mean $14.7\pm1.6).$ The temperatures at which EEG reappeared $5~15.4^{\circ}C$ for esophagus. There was no neurological defic t and no surgical mortality in this series. In summary, the electrical cerebral activity Teappeared within 23 minutes at the temperature less than $16^{\circ}C$ for rectum. It seemed that $15^{\circ}C$ of esophageal temperature was not safe for 20 minutes of TCA and continuous monitoring the EEG with CSA to identify the electrocerebral silence was useful.

  • PDF

Early and Midterm Results of the Extracardiac Fontan Operation and the Change of Internal Diameter of the Conduit (심외도관 폰탄수술후 중단기 성적 및 심외도관의 내경의 변화)

  • 성시찬;김시호
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.177-181
    • /
    • 2002
  • Background: Follow-up studies have shown that although outcomes have improved substantially over time, results of the Fontan operation and its modifications remain suboptimal. In this study, we reviewed our experience with the extracardiac conduit Fontan operation, with a focus early and midterm change of internal diameter of PTFE conduit. Material and Method: Between April 1997 and July 2000 were reviewed. Twelve patients (M:6, F:6, mean age 42.04 $\pm$ 12.43months, mean body weight 13.80$\pm$ 1.94kg) underwent extracardiac conduit Fontan operation with expanded PTFE graft. Mean cardiopulmonary bypass time was 109.7$\pm$26.99minute and mean operation time was 455$\pm$89.51minute. Intraoperative fenestration was performed in 10 patients. The aortic cross clamping was not performed in all patients. Result: There was no early deaths and no postoperative dysrhythmia. Postoperative protein losing enteropathy and prolonged pleural effusion occurred in 1(8.3%) and 4 patients(33.3%). Conduit patency was evaluated by magnetic resonance imaging studies. A 9.84$\pm$3.84% mean reduction in conduit internal diameter and there was no statistical correlation between the change of internal diameter of conduit and the postoperative duration after partial correlation analysis(r=0.019, p=0.955). Conclusion: These results demonstrate that the extracardiac conduit Fontan operation provies good early and midterm results and may reduce the prevalence of late arrhythmia. And there is no correlation between the change of internal diameter of conduit and the postoperative duration after extracardiac conduit Fontan operation with the expanded PTFE graft conduit.

Intraoperative Measurement and Analysis of Coronary Artery Bypass Graft Flow (수술중 측정한 관상동맥 우회도관 혈류량의 분석)

  • Park, Kye-Hyun;Chae, Hurn;Yun, Yang-Ku;Lee, Jae-Woong;Kim, Kwhan-Mien;Jun, Tae-Gook;Kim, Jhin-Gook;Shim, Young-Mog;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.760-769
    • /
    • 1997
  • This study aimed to determine factors that influence blood flow through coronary bypass grafts and to analyze relationship between the graft flow and postoperative outcome. Blood flow through 146 bypass grafts(GBF) was measured with transit-time ultrasound flowmeter during coronary artery bypass grafting operations in 50 patients. Single and multiple regression analyses were done for relationships between the GBF and four variables: internal diameter of recipient coronary artery, myocardial value of bypassed branch(es), type of graft, and finding of preoperative myocardial perfusion scan. The relationship between GBF and postoperative scan finding was also analyzed. 1. The mean GBF was significantly higher in sequential grafts than in single vein grafts or in internal thoracic artery grafts(61.5 vs. 46.9 and 42.5 ml/min). 2. Myocardial value and recipient artery diameter were found to be the factors determining GBF. There was no correlation between GHF and presence of perfusion defect in the preoperative scan. 3. Myocardial value was found to be more important than recipient artery diameter in determinintg GBF. 4. Reversible perfusion defects were more frequently found in the areas upplied by grafts with low GBP. But this fact had only mild statistical significance. These results suggest that blood flow through a bypass graft is more determined by the size of its supplyinf: myocardium than by the size of recipient artery. So, we can expect effective improvement in myocardial flow reserve after grafting of small(1~1.5mm) coronary arteries, if they supply substantial area of myocardium.

  • PDF

Development of $^{99m}Tc$-Transferrin as an Imaging Agent of Infectious Foci (감염병소 영상을 위한 $^{99m}Tc$-Transferrin 개발)

  • Kim, Seong-Min;Song, Ho-Chun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.177-185
    • /
    • 2006
  • Purpose: Purpose of this study is to synthesize $^{99m}Tc$-labeled transferrin for injection imaging and to compare it with $^{67}Ga$-titrate for the detection of infectious foci. Materials and methods: Succinimidyl 6-hydrazino-nicotinate hydrochloride-chitosan-transferrin (Transferrin) was synthesized and radiolabeled with $^{99m}Tc$. Labeling efficiencies of $^{99m}Tc$-Transferrin were determined at 10 min, 30 min, 1 hr, 2 hr, 4 hr and 8 hr. Biodistribution and imaging studies with $^{99m}Tc$-Transferrin and $^{67}Ga$-citrate were performed in a rat abscess model induced with approximately $2{\times}10^8$ colony forming unit of Staphylococcus aureus ATCC 25923. Results: Successful synthesis of Transferrin was confirmed by mass spectrometry. Labeling efficiency of $^{99m}Tc$-Transferrin was $96.2{\pm}0.7%,\;96.4{\pm}0.5%,\;96.6{\pm}1.0%,\;96.9{\pm}0.5%,\;97.0{\pm}0.7%\;and\;95.5{\pm}0.7%$ at 10 min, 30 min, 1 hr, 2 hr, 4 hr and 8 hr, respectively. The injected dose per tissue gram of $^{99m}Tc$-Transferrin was $0.18{\pm}0.01\;and\;0.18{\pm}0.01$ in the lesion and $0.05{\pm}0.01\;and\;0.04{\pm}0.01$ in the normal muscle, and lesion-to-normal muscle uptake ratio was $3.7{\pm}0.6\;and\;4.7{\pm}0.4$ at 30 min and 3 hr, respectively. On image, lesion-to-background ratio of $^{99m}Tc$-Transferrin was $2.18{\pm}0.03,\;2.56{\pm}0.11,\;3.08{\pm}0.18,\;3.77{\pm}0.17,\;4.70{\pm}0.45\;and\;5.59{\pm}0.40$ at 10 min, 30 min, 1 hr, 2 hr, 4 hr and 10 hr and those of $^{67}Ga$-citrate was $3.06{\pm}0.84,\;4.12{\pm}0.54\;and\;4.55{\pm}0.74 $ at 2 hr, 24 hr and 48 hr, respectively. Conclusion: Transferrin is successfully labeled with $^{99m}Tc$, and its labeling efficiency was higher than 95% and stable for 8 hours. $^{99m}Tc$-Transferrin scintigraphy showed higher image quality in shorter time compared to $^{67}Ga$-citrate image. $^{99m}Tc$-transferrin is supposed to be useful in the detection of the infectious foci.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF