• Title/Summary/Keyword: IT monitoring

Search Result 10,258, Processing Time 0.034 seconds

A Study of Multiplex RE Monitoring Method of Low-Price for Stand-Alone PV Power Generation System (독립형 태양광 발전 시스템을 위한 저가의 다중 무선 모니터링 기법에 관한 연구)

  • Oh Jin-Seok;Kwak Jun-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.579-586
    • /
    • 2005
  • Recently, it has demanded to the wireless monitoring system in stand-alone PV power generation system. We propose the multiplex monitoring method using RF unit of low-price. RF unit consists of RF modem and communication controller. It is also able to use by repeater to communicate long distance. In this paper. two algorithms were programmed by CCS-C and C++ for multiplex monitoring method, The algorithm of choosing unit was used 'select and poll method' and the course assignment algorithm was embodied with 'Bellman-Ford algorithm'. The good result was achieved in the actual test without communication-data lose. The proposed method will be applied such as monitoring system of PV light on the wayside, monitoring system of unmanned lighthouse, monitoring system of refrigeration container on vessel and so on. It can be applied in the field that various ocean energy system.

The Monitoring on Gradual Change of Seepage Blocking State with the Hydraulic Head Loss Rate Change According to Passage of time in Sea Dike Embankment (수두손실률의 경시변화에 의한 방조제 제체의 점진적인 차수상태 변화 감시)

  • Eam, Sung Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • In this study it was adopted on sea dike monitoring that the safety monitoring with statistical limits which was adapted usually on safety monitoring by measuring pressures, stresses or deformations. And also the hydraulic head loss rate change according to passage of time was calculated for the purpose of safety monitoring. Safety monitoring by setting the statistical limit on the measured pore water pressure graphs need to be supplemented with an additional method of monitoring because the difference between the rise and fall of the tide was irregular. Safety monitoring by the limits set from values predicted by linear regression and standard errors on the hydraulic head loss graph was not affected by irregularity of tide. But if the condition of an embankment is changed gradually and slowly, it will not be detected on the hydraulic head loss graph. The graph of hydraulic head loss rate for every 24 hours vs date showed clearly that the sea water blocking state was getting better or not even though it was changed gradually and slowly.

A Study on the Convergence of Monitoring and Control System with Geographic Information System (지리정보시스템과 관제시스템의 융합에 관한 연구)

  • Seo, Tae-Woong;Kim, Chang-Soo;Lee, Jae-Sung;Lee, Cheol-Won
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.5
    • /
    • pp.703-709
    • /
    • 2011
  • State-based infrastructure on IT-based network are prone to numerous cyber attack including subsequent hacking and internet infringement. These acts of terrorism are increasing because of the expanding IT convergence technology. Recently, the trend on cyber security monitoring and control researches focus on combining the general idea of security monitoring and control along with IT field and other control systems. This convergence trend has been increasing in both the use and importance. This research analyzes the state-based infrastructure monitoring and control system, its vulnerability as well as its improvement by incorporating the cyber convergence systems to existing systems. The subject of this research is for extensive use of CCTV systems which is expanded for 'CCTV Monitoring and Control Field' as well as 'Traffic Monitoring and Control Field' operated by 'Intelligent Traffic Information System' and Disaster Management Area which is studied in various fields. Eventually, the objective of the paper is to solve these issues, to apply related systems and to suggest improvement on the convergence system.

Development of a Portable Total-phosphorus Monitoring System for Preventing Eutrophication in Advance (부영양화 사전 예방을 위한 휴대용 총인 모니터링 시스템 개발)

  • Jung, Dong Geon;Kim, Seung Deok;Kwon, Soon Yeol;Lee, Jae Yong;Kim, Yu Seong;Lee, Junyeop;Kim, JaeKeon;Kim, Sae-Wan;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.342-347
    • /
    • 2020
  • In this study, a portable total-phosphorus (TP) monitoring system utilizing a photocatalytic-reaction-based pretreatment method is proposed, fabricated, and characterized. Commercial TP monitoring systems are only used in laboratories because of their complex monitoring procedure, bulk-size, and high-cost. In particular, pretreatment in commercial TP monitoring systems is performed at high temperatures (> 120 ℃) and pressure (> 1.1 kg cm-2) making it difficult to minimize the scale of the systems. The proposed TP monitoring system employs a pretreatment method with a photocatalytic reaction; thus, its size can be reduced, as photocatalytic reactions occur at room temperature and atmospheric pressure. Analytes with various TP concentrations are pretreated using the proposed portable TP monitoring system and are quantitatively measured with an LED and a photodiode.

Car Sealer Monitoring System Using ICT Technology (ICT 기술을 융합한 자동차 실러도포 공정 모니터링 시스템)

  • Kim, Ho Yeon;Park, Jong Seop;Park, Yo Han;Cho, Jae-Soo
    • Journal of Information Technology Services
    • /
    • v.17 no.3
    • /
    • pp.53-61
    • /
    • 2018
  • In this paper, we propose a car sealing monitoring system combined with ICT Technology. The automobile sealer is an adhesive used to bond inner and outer panels of doors, hoods and trunks of an automobile body. The proposed car sealer monitoring system is a system that can accurately and automatically inspect the condition of the automobile sealer coating process in the general often factory production line where the lighting change is very severe. The sealer inspection module checks the state of the applied sealer using an area scan camera. The vision inspection algorithm is adaptive to various lighting environments to determine whether the sealer is defective or not. The captured images and test results are configured to send the task results to the task manager in real-time as a smartphone app. Vision inspection algorithms in the plant outdoors are very vulnerable to time-varying external light sources and by configuring a monitoring system based on smart mobile equipment, it is possible to perform production monitoring regardless of time and place. The applicability of this method was verified by applying it to an actual automotive sealer application process.

A Message Monitoring Framework for Tracing Messages on JBI-based Enterprise Service Bus (JBI 기반 ESB 환경에서 효과적인 메시지 추적을 위한 메시지모니터링 프레임워크)

  • Choi, Jae-Hyun;Park, Jae-Won;Lee, Nam-Yong
    • Journal of Information Technology Services
    • /
    • v.9 no.2
    • /
    • pp.179-192
    • /
    • 2010
  • In order to resolve the problems of traditional Enterprise Application Integration (EAI) for system integration and to establish flexible enterprise IT environments, Enterprise Service Bus(ESB) which have distributed architecture and support Service Oriented Architecture(SOA) has introduced. Particularly, JBI which developed by the Java Community Process is most widely used to implement ESB for advantages of Java technology. In ESB based on JBI, reliable message delivery is very important to ensure stability of services and systems because it is a message driven architecture. But, it is difficult to verify messages and trace messages when system fault or service error occurred because JBI specification is not enough to address them. In this paper we has proposed the Message Monitoring Framework for JBI-based ESBs which for using in monitoring messages efficiently. It provides foundations for gathering and tracing message-related information about component installation, message exchange, service deploy by using proxy-based change tracking and delegation mechanism for data processing. The proxy which used in our solutions collects data about message automatically when it changed, and the delegation mechanism provides users flexibility for data processing. Also, we describe the performance evaluation results of our solution which is acceptable. We expect to it enables users to ensure reliability and stability of the JBI-based ESB by systematic monitoring and managing messages being used to interact among components.

A Study on the Correlation of Condition Monitoring Parameters of Functional Machine Failures. (기계시스템 파손에 따른 상태진단 파라미터의 상관관계 해석에 관한 연구)

  • 장래혁;강기홍;공호성;최동훈
    • Tribology and Lubricants
    • /
    • v.18 no.4
    • /
    • pp.285-290
    • /
    • 2002
  • Integrated condition monitoring is required to monitor effectively the machine conditions since machine failures could not be monitored accurately by any single measurement parameter. Application of various condition monitoring techniques is therefore preferred in many cases in order to diagnosis the machine condition. However it inevitably requires lots of maintenance cost and sometimes it could be proved to over-maintenance unnecessarily. This could happen especially when one measurement parameter closely correlates to another. Therefore correlation analysis of various monitoring parameters has to be performed to improve the reliability of diagnosis. In this work, Pearson correlation coefficient was used to analyze the correlation between condition monitoring parameters of an over-loaded machine system where the vibration, wear and temperature were monitored simultaneously. The result showed that Pearson correlation coefficient could be regarded as a good measure for evaluating the availability of condition monitoring technology.

The Development of a remote monitoring and control system for a Fire Protection of Chemical Factory (화학공장의 소방안전을 위한 원격감시 제어시스템 개발)

  • Kim, Hyung-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.151-160
    • /
    • 2009
  • At this study, we are developing a possible control system through remote monitoring for fire protection in various chemical factory facilities. It's possible to do real time confirmation of a normal operation presence of the various equipment installed in a chemical factory through the internet network at a fire fighting head office, an area fire department and a chemical factory situation room using this remote monitoring control system. When occurring, abnormal operation is the remote monitoring control system, which can check this immediately and notify the situation room administrator. After it was tested using developed remote monitoring control system, the remote monitoring for which the internet network was used confirmed possible.

A Study on the Correlation of Condition Monitoring Parameters of Functional Machine Failures. (기계시스템 파손에 따른 상태진단 파라미터의 상관관계 해석에 관한 연구)

  • 장래혁;강기홍;공호성;최동훈
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.252-259
    • /
    • 2001
  • Integrated condition monitoring is required to monitor effectively the machine conditions since machine failures could not be monitored accurately by any single measurement parameter. Application of various condition monitoring techniques is therefore preferred in many cases in order to diagnosis the machine condition. However it inevitably requires lots of maintenance cost and sometimes it could be proved to over-maintenance unnecessarily. This could happen especially when one measurement parameter closely correlates to another. Therefore correlation analysis of various monitoring parameters has to be performed to improve the reliability of diagnosis. In this work, Pearson correlation coefficient was used to analyze the correlation between condition monitoring parameters of an over-loaded machine system where the vibration, wear and temperature were monitored simultaneously. The result showed that Pearson correlation coefficient could be regarded as a good measure for evaluating the availability of condition monitoring technology.

  • PDF

A MODEL OF CONSTRUCTION WORKER'S PERCEPTIONS ON ELECTRONIC MONITORING

  • Bill L.P. Lee;Stephen Mak
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.190-195
    • /
    • 2009
  • With the growth of information and communication technologies adoption in construction projects, it could be anticipated that more property owners and construction firms will attempt to use electronic gears and gadgets for site monitoring or surveillance purposes. As the construction workers may be the major group of project team members being monitored, from managerial perspectives and for ethical reasons, it is essential to investigate their degree of acceptance on site monitoring systems. Indeed studies on office workplace monitoring suggest that a monitoring system could shape or control the behaviors of employees. With adequate refinements, their research models could be applicable in the construction industry. This paper presents a model for analyzing the antecedences that affect workers' acceptance level on electronic monitoring, and investigating if there is any behavioral change.

  • PDF