• Title/Summary/Keyword: IT evaluation

Search Result 30,395, Processing Time 0.07 seconds

Evaluation of Effective Dose in Dental Radiography (치과 방사선 검사에서 유효선량 평가)

  • Han, Su-Chul;Lee, Bo-Ram;Shin, Gwi-Soon;Choi, Jong-Hak;Park, Hyok;Park, Chang-Seo;Chang, Kye-Yong;Kim, Bo-Ram;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.27-33
    • /
    • 2011
  • Along with the developments of science technology, up-to-date medical radiation equipments are introduced. Those equipments has brought many progresses in diagnosing patients not only in the quantitative aspects but in the qualitative ones. Especially, in the case of dental radiography, patients can be exposed more than CT, cone beam computed tomography (CBCT). In this study, we used human phantom and TLD-100H to measure the organ dose in each dental radiography and computed the effective dose according to ICRP (International Committee for Radioactivity Prevention) 60, 103. We measured the effective dose to be 5.1 and $29.5{\mu}Sv$ in the panoramic radiography and 11.2 and $14.4{\mu}Sv$ in the cephalometric radiography respectively. We also executed the CBCT and CT test on the maxillaries and the mandibles and found the amounts of effective dose were 53.7, 209.6, 129, and $391.5{\mu}Sv$ respectively in the CBCT and $93.3{\mu}$, 139.5, 282.7 and $489.7{\mu}Sv$ in the CT test. Consequently, it was shown that the effective dose in the CBCT test was lower than one in the CT test, but was higher in both panoramic and cephalometric radiography.

A Study on the Evaluation of Patient Dose in Interventional Radiology (중재적방사선검사에서 환자 피폭선량에 관한 연구)

  • Park, Hyung-Sin;Lim, Cheong-Hwan;Kang, Byung-Sam;You, In-Gyu;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.299-308
    • /
    • 2012
  • To perform patient dose surveys in major interventional radiography procedures as a mean of inter-institutional comparison and of establishing reference dose levels with the ultimate goal of optimizing patient doses in the field of interventional radiography. We reviewed international patient dose survey data in the literature and measured patient dose in major interventional radiography procedures (TACE, AVF, PTBD, TFCA, GDC embolization). ESD(Entrance Skin Dose) was measured using TLD chips attached to the patient skin and ED(Effective Dose) was calculated using angiography unit-derived DAP. A survey of patient dose in interventional radiography procedures were also performed with a questionnaire for interventional radiologists and we proposed a guideline for optimizing patient doses in the field of interventional radiology. The patient dose survey data in interventional radiography procedures were very rare in literature compared with those in diagnostic radiography procedures. In TACE, the mean ED was 25.43 mSv and the mean ESD was 511.75 mGy. The mean ED of TACE was not high, but the cumulative dose should be checked, due to longer procedure TACE. In TFCA, the mean ED was 22.6 mSv and it was relatively high compared with data of other countries. In GDC embolization, the mean ED was not available, because GDC embolization was performed with old Image-Intensifier-type unit and there has no unit-installed ionization chamber. Also, the mean ESD of GDC embolization was up to 2,264 mGy and further studies are needed to calculate the net ED of GDC embolization. Patient dose occurred during interventional radiography procedures are high related with the difficulty of the procedure, fluoroscopy time, the number of angiographies and the treatment protocol. Therefore, continuous education and efforts should be made to optimize the patient dose in the field of interventional radiology.

Evaluation of Photoneutron Dose for Prostate Cancer Radiation Therapy by Using Optically Stimulated Luminescence Dosimeter (OSLD) (전립선암 방사선치료 시 광자극발광선량계를 이용한 광중성자선량 평가)

  • Lee, Joo-Ah;Back, Geum-Mun;Kim, Yeon-Soo;Son, Soon-Yong;Choi, Kwan-Woo;Yoo, Beong-Gyu;Jeong, Hoi-Woun;Jung, Jae-Hong;Kim, Ki-Won;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.125-134
    • /
    • 2014
  • This study is to provide basic information regarding photoneutron doses in terms of radiation treatment techniques and the number of portals in intensity-modulated radiation therapy (IMRT) by measuring the photoneutron doses. Subjects of experiment were 10 patients who were diagnosed with prostate cancer and have received radiation treatment for 5 months from September 2013 to January 2014 in the department of radiation oncology in S hospital located in Seoul. Thus, radiation treatment plans were created for 3-Dimensional Conformal Radiotherapy (3D-CRT), Volumetric-Modulated Arc Radiotherapy (VMAT), IMRT 5, 7, and 9 portals. The average difference of photoneutron dose was compared through descriptive statistics and variance analysis, and analyzed influence factors through correlation analysis and regression analysis. In summarized results, 3D-CRT showed the lowest average photoneutron dose, while IMRT caused the highest dose with statistically significance (p <.01). The photoneutron dose by number of portals of IMRT was $4.37{\pm}1.08mSv$ in average and statistically showed very significant difference among the number of portals (p <.01). Number of portals and photoneutron dose are shown that the correlation coefficient is 0.570, highly statistically significant positive correlation (p <.01). As a result of the linear regression analysis of number of portals and photoneutron dose, it showed that photoneutron dose significantly increased by 0.373 times in average as the number of portals increased by 1 stage. In conclusion, this study can be expected to be used as a quantitative basic data to select an appropriate IMRT plans regarding photoneutron dose in radiation treatment for prostate cancer.

Superiority of Modifiled University of Wiscinsin Solution in the Prolonged Preservation of Isolated Rat Heart (적출 쥐 심장의 장시간 보존에 있어서 University of Wisconsin 수정 용액의 우수성)

  • Lee, Jae-Seong;Kim, Song-Myeong;Kim, Gyu-Tae
    • Journal of Chest Surgery
    • /
    • v.26 no.6
    • /
    • pp.427-440
    • /
    • 1993
  • The paucity of donor hearts for transplantation can be remedied by distant heart procurement. Prolonging donor heart preservation is essential for successful clinical cardiac transplantation. Thirty-two isolated rat hearts were perfused with Krebs-Henseleit buffer solution for 15 minutes, arrested and preserved at 4 oC for 4 hours, and then reperfused for 25 minutes. The following three groups were prepared and hemodynamic changes, creatine kinase-MB isoenzyme levels and ultrastructural changes of the myocardium were analysed before and after cardiac arrest. ; Group I : the heart was arrested with the cardioplegic solution [Plegisol, potassium : 16 mM, sodium : 120 mM] and then stored in a solution with ionic compositions of the extracellular fluid [Hartman, potassium : 4 mM, sodium : 130 mM] ; Group II : the heart was arrested with the cardioplegic solution and stored in a solution with ionic compositions of the intracellular fluid [Modified Euro-Collins, potassium : 108 mM, sodium : 10 mM] ; Group III : the heart was arrested with the cardioplegic solution containing adenosine 20 uM, and then stored in a solution with ionic compositions of the intracellular fluid [Modified University of Wisconsin solution, potassium : 119 mM, sodium: 23 mM]. Left ventricular developed pressure at 20 minutes of the reperfusion was significantly higher in group III [64.3 $\pm$ 3.12 mmHg, p<0.01] and group II [58.3 $\pm$ 1.55 mmHg, p<0.05] as compared with group I [51.4$\pm$ 2.78 mmHg]. The time to induce cardiac arrest after infusion of cardioplegic solution with adenosine 20 uM [5.3 $\pm$ 0.30 second, p<0.005] was significantly shorter than without adenosine [10.6$\pm$ 0.55 second]. Coronary flow at 20 minutes of the reperfusion was augmented significantly in group III [9.6$\pm$ 0.50 ml/min, p<0.05, p<0.05] as compared with group I [8.0 $\pm$ 0.41 ml/min] and group II [8.1$\pm$ 0.51 ml/min]. Percentage recovery of left ventricular developed pressure at 20 minutes of the reperfusion was significantly higher in group III [94.6$\pm$ 2.51 %, p<0.005] as compared with group II and in group II [83.1 $\pm$ 1.22 %, p<0.005] as compared with group I [69.9 $\pm$ 1.73 %], and also percentage recovery of coronary flow at 20 minutes of the reperfusion was significantly higher in group III [82.3 $\pm$ 3.86 %, p<0.05] as compared with group II [71.4 $\pm$ 3.46 %] but there was no significant difference between group I and group II. Measured level of creatine kinase-MB isoenzyme at 15 minutes of the reperfusion was significantly lower in group III [1.23 $\pm$ 0.16 ng/ml, p<0.025] and group II [1.42$\pm$ 0.10 ng/ml, p<0.05] as compared with group I [1.79 0.14 ng/ml]. In the semiquantitative evaluation of the ultrastructural changes of the myocardium, mitochondrial score was lower in group III [0.7 $\pm$ 0.21] than in group I [3.1$\pm$ 0.28] and group II [1.7 $\pm$ 0.19], and also the other structural score was lower in group III [2.7$\pm$ 0.99] than in group I [7.9 $\pm$ 0.89] and group II [5.0 $\pm$ 1.22]. In conclusion, the solution with ionic compositions of the intracellular fluid is appropriate for prolonged cardiac preservation, and it appears to be better preserving method for distant procurement when the donor heart is rapidly arrested with cardioplegic solution containing adenosine 20 uM, and then stored with Modified University of Wisconsin solution.

  • PDF

Utility of $^{99m}Tc$-MAG3 Perfusion Indices in the Evaluation of Renal Transplant Function During Early Post-transplantation Period (이식 초기 이식신 기능 평가에서 $^{99m}Tc$-MAG3 신관류 지표의 유용성)

  • Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.497-507
    • /
    • 2000
  • Purpose: We have examined the utility of $^{99m}Tc$-MAG3 perfusion indices for assessing renal graft function in early post-transplantation period. Materials and Methods: Our study included 80 renal transplant recipients (48 men and 32 women, mean age: 40.3 years). Diagnosis was based on biopsy, laboratory data and clinical course. Renal scintigraphy (RS) was obtained using 100 MBq of $^{99m}Tc$-MAG3 from 11 days to 23 days of kidney transplantation. We measured 5 indices in whole-kidney (WK) and cortical (C) renograms; Hilson's perfusion index (PI), transplant perfusion index (TP) and transplant function index (TF) as perfusion parameter, and the time to peak activity (Tmax) and the ratio of renal counts at 20 min to that at 3 min (K20/3) as functional parameter. Results: The diagnoses at the day of RS were normal graft (NG) in 44, acute rejection (AR) in 14, acute tubular necrosis (ATN) in 10, and Cyclosporine A nephrotoxicity (CsA) in 12. TP and TF were significantly decreased in AR, ATN and CsA, compared to those in NG. K20/3 of AR and ATN wore significantly greater than that of NG. WK-Tmax of AR was significantly longer than that of NG. K20/3 of AR and C-K20/3 of ATN were significantly prolonged relative to those of CsA. There were no statistically significant perfusion indices among complication groups. Conclusion: TP and TF reflecting microperfusion and initial tubular extraction are reliable in assessing graft function. However, it is required to correlate perfusion indices with functional indices and clinical course in differentiating from one another among complication groups.

  • PDF

In Vitro Uptakes of Radiolabeled IVDU and IVFRU in Herpes Simplex Virus Type-1 Thymidine Kinase (HSV1-tk) Gene Transduced Morris Hepatoma Cell Line (단순 헤르페스 제 1형 티미딘 키나제 유전자 이입 간암세포주에서 방사표지 IVDU와 IVFRU의 섭취 평가)

  • Lee, Tae-Sup;Choi, Tae-Hyun;Ahn, Soon-Hyuk;Woo, Kwang-Sun;Jeong, Wee-Sup;Kwon, Hee-Chung;Awh, Ok-Doo;Choi, Chang-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.62-73
    • /
    • 2004
  • Purpose: The herpes simplex virus type 1 thymidine kinase gene(HSV1-tk) is an attractive candidate as a reporter gene in noninvasive reporter gene monitoring system. The HSV1-tk gene was chosen as a reporter gene, because it has been extensively studied, and there are appropriate reporter probes, substrates of HSV1-tk gene product, to apply for HSV1-tk gene imaging. We used radiolabeled 5-iodovinyl-2'-deoxyuridine (IVDU) and 5-iodovinyl-2'-fluoro-2'-deoxyuridine (IVFRU) as reporter probes for HSV1-tk gene monitoring system. Materials and Methods: We prepared HSV1-tk gene transduced Morris hepatoma cell line using retroviral vector, MOLTEN containing HSV1-tk gene. And we confirmed the HSV1-tk gene expression by Northern blotting and Western blotting. We compared in vitro uptakes of radioiodinated IVDU and IVFRU to monitor HSV1-tk gene expression in Morris hepatoma cell line (MCA) and HSV1-tk gene tranduced MCA (MCA-tk) cells until 480 minutes. We also peformed correlation analysis between percentage of HSV1-tk gene tranduced MCA cell % (MCA-tk%) and uptakes of radiolabeled IVDU or IVFRU. Results: MCA-tk cell expressed HSV1-tk mRNA and HSV1-TK protein. Two compounds showed minimal uptake in MCA, but increased uptake was observed in MCA-tk. IVDU showed 4-fold higher accumulation than IVFRU at 480 min in MCA-tk (p<0.01). Both IVDU and IVFRU uptake were linearly correlated ($R^2>0.96$) with increasing MCA-tk%. Conclusion: The radiolabeld IVDU and IVFRU showed higher specific accumulation in retrovirally HSV1-tk gene transfected Morris hepatoma cell line. Both IVDU and IVFRU could be used as good substrates for evaluation of HSV1-tk gene expression.

The Role of Hepatobiliary Scintiuaphy and Oral Cholecystography in Predicting the Performance of Laparoscopic Cholecystectomy (복강경담낭절제술에서 수술전 간담도신티그라피와 경구담낭조영술의 의의)

  • Won, Kyoung-Sook;Moon, Dae-Hyuk;Yang, Seoung-Oh;Han, Dong-Bok;Park, Cheol-Min;Lee, Moon-Gyu;Lee, Hee-Kyung;Park, Kwang-Min;Lee, Sung-Gyu;Ryu, Jin-Sook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.102-107
    • /
    • 1997
  • Laparoscopic cholecystectorny can be performed safely in most patients with symptomatic cholelithiasis. Preoperative evaluation should assess the potential problems that affect the performance of laparoscopic cholecystectomy. Hepatobiliary scintigraphy or oral cholecystography can assess the gallbladder function and nonvisualization of gallbladder usually indicates acute or severe chronic cholecystitis. The purpose of this study was to evaluate the role of preoperative hepatobiliary scintigraphy or oral cholecystography in predicting the performance of laparoscopic cholecystectorny. The study group consists of 176 patients who underwent both hepatobiliary scintigraphy with Tc-99m DISIDA and oral cholecystography within one month before laparoscopic cholecystectomy. Nonvisualization of gallbladder was defined as persistent nonvisualization of gallbladder until 4 hours on hepatobiliary scintigraphy or 12 hours on oral cholecystography. Among 176 patients, gallbladder was not visualized in 38 patients on hepatobiliary scintigraphy and 41 patients on oral cholecystography. Concordance rate between hepatobiliary scintigraphy and oral cholecystography was 89.2%. The conversion rate to open cholocystectomy was significantly higher in patients with nonvisualization of gallbladder than in patients with gallbladder visualization(15.8% vs 2.9% on hepatobiliary scintigraphy, 12.2% vs 3.7% on oral cholecystography p<0.01 and p<0.05 respectively). The operative complication rate was also significantly higher in patients with nonvisualization of gallbladder (13.2% vs 2.9% on hepatobiliary scintigraphy, 14.6% vs 2.2% on oral cholecystography p<0.01 and p<0.001, respectively). Similarly, operation time was significantly prolonged in patients with nonvisualization of gallbladder ($88.8{\pm}41.9min$ vs $62.5{\pm}23.6min$ on hepatobiliary scintigraphy : p<0.001, $89.4{\pm}41.3$ min vs $61.8{\pm}22.8$ min on oral cholecystography : p<0.001). It is concluded that nonvisualization of gallbladder on hepatobiliary scintigraphy or oral cholecystography is a valuable preoperative clinical risk factor in predicting increased conversion rate to open cholecystectomy, increased operative complication and prolonged operation time.

  • PDF

The Evaluation of Resolution Recovery Based Reconstruction Method, Astonish (Resolution Recovery 기반의 Astonish 영상 재구성 기법의 평가)

  • Seung, Jong-Min;Lee, Hyeong-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Kim, Joong-Hyun;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.58-64
    • /
    • 2011
  • Objective: The 3-dimensional reconstruction method with resolution recovery modeling has advantages of high spatial resolution and contrast because of its precise modeling of spatial blurring according to the distance from detector plane. The aim of this study was to evaluate one of the resolution recovery reconstruction methods (Astonish, Philips Medical), compare it to other iterative reconstructions, and verify its clinical usefulness. Materials and Methods: NEMA IEC PET body phantom and Flanges Jaszczak ECT phantom (Data Spectrum Corp., USA) studies were performed using Skylight SPECT (Philips) system under four different conditions; short or long (2 times of short) radius, and half or full (40 kcts/frame) acquisition counts. Astonish reconstruction method was compared with two other iterative reconstructions; MLEM and 3D-OSEM which vendor supplied. For quantitative analysis, the contrast ratios obtained from IEC phantom test were compared. Reconstruction parameters were determined by optimization study using graph of contrast ratio versus background variability. The qualitative comparison was performed with Jaszczak ECT phantom and human myocardial data. Results: The overall contrast ratio was higher with Astonish than the others. For the largest hot sphere of 37 mm diameter, Astonish showed about 27.1% and 17.4% higher contrast ratio than MLEM and 3D-OSEM, in short radius study. For long radius, Astonish showed about 40.5% and 32.6% higher contrast ratio than MLEM and 3D-OSEM. The effect of acquired counts was insignificant. In the qualitative studies with Jaszczak phantom and human myocardial data, Astonish showed the best image quality. Conclusion: In this study, we have found out that Astonish can provide more reliable clinical results by better image quality compared to other iterative reconstruction methods. Although further clinical studies are required, Astonish would be used in clinics with confidence for enhancement of images.

  • PDF

The Evaluation of Usefulness of Wide Beam Reconstruction Method on Segmental Perfusion and Regional Wall Motion in Myocardial Perfusion SPECT (심근관류 SPECT의 분절별 관류 및 국소벽 운동에서 Wide Beam Reconstruction기법의 유용성 평가)

  • Seong, Yong-Joon;Kim, Tae-Yeob;Moon, Il-Sang;Cho, Seong-Wook;Woo, Jae-Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • Purpose: The aim of this study is to identify clinical usefulness of Wide Beam Reconstruction (WBR) which is called Xpress.cardiac$^{TM}$ to confirm the agreement between segmental perfusion and regional wall motion in myocardium compared to conventional OSEM method. Materials and Methods: Subjects were separated two groups. First group was composed of 20 normal control group. Second group was composed of 10 patients (abnormal group) who had coronary artery disease. Subjects underwent myocardial perfusion SPECT ($^{201}Tl$ rest and $^{99m}Tc$-MIBI stress). Image acquisition and reconstruction were that rest stage was each step per 30, 15 seconds and stress stage was each step per 25, 13 seconds, OSEM and WBR methods were applied. Segmental perfusion and regional wall motion were applied 20-segment model of QPS, QGS algorithm in AutoQuant. Status of perfusion was composed of 5 point scoring system (0=normal, 1=mild, 2=moderate, 3=severe hypokinesia, 4=dyskinesia). Status of regional wall motion was also composed of 5 point scoring (0=normal, 1=mild, 2=moderate, 3=severe hypokinesia, 4=dyskinesia). We evaluated the agreement between conventional OSEM and WBR through automatic quantification value. Results: The agreement of rest segmental perfusion between conventional OSEM and WBR in normal patients was 99% (396/400, k=0.662, p<0.0001) and one of rest regional wall motion was 83.8% (335/400, k=0.283), the agreement of stress segmental perfusion was 95.8%(383/400, k=0.656), one of stress regional wall motion was 87.3% (349/400, k=0.390). The match rate of rest segmental perfusion in abnormal patients was 83% (166/200, k=0.605, p<0.0001) and one of rest regional wall motion was 55.5% (111/200, k=0.385), the agreement of stress segmental perfusion was 79.5% (159/200, k=0.682), one of stress regional wall motion was 63.5% (127/200, k=0.486). Conclusion: Compared to conventional OSEM, WBR method had a good agreement of segmental perfusion in myocardium in normal and abnormal groups. However regional wall motion showed meaningful low agreement. Although WBR offers high resolution and contrast ratio, it is not useful method for gated myocardial perfusion SPECT.

  • PDF

Development of Auto-aging System Built in Kimchi Refrigerator for Optimal Fermentation and Storage of Korean Cabbage Kimchi (배추김치의 최적발효 및 저장을 위한 김치냉장고의 자동숙성 시스템 개발)

  • Noh, Jeong-Sook;Seo, Hyun-Ju;Oh, Jung-Hwan;Lee, Myung-Ju;Kim, Myung-Hee;Cheigh, Hong-Sik;Song, Yeong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.432-437
    • /
    • 2007
  • In this study, we examined the conditions for an auto-aging system placed within a kimchi refrigerator for optimal fermentation, and to prolong the storage time of kimchi. Various characteristics of kimchi fermented at different temperatures ($5-23^{\circ}C$) were compared. We observed that the higher the fermentation temperature, the less desirable the overall acceptability of the product. To establish the time point in which to convert the fermentation mode to the storage mode, kimchi was stored at $-1^{\circ}C$ for 1 week once it reached the designated acidity (0.4, 0.6, and 0.8%). The results indicated that the lower the kimchi acidity, the higher the sensory score. The storage temperature of $-1^{\circ}C$ was not low enough to retard microorganism growth completely; however, the kimchi stored at $-2{\pm}0.5^{\circ}C$ became frozen. Accordingly, $15^{\circ}C$ and $-2{\pm}0.5^{\circ}C$ are suggested as the fermentation and storage temperatures for the kimchi refrigerator, respectively. A kimchi acidity of 0.4% can be used as an index for the time point to convert fermentation to storage. Subsequently, the time required for the fermentation course can be calculated based on this.