• Title/Summary/Keyword: IT evaluation

Search Result 30,546, Processing Time 0.057 seconds

The Research of Comparison Evaluation on the Decline in Artifact Using Respiratory Gating System in PET-CT (PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가)

  • Kim, Jin-Young;Lee, Seung Jae;jung, Suk;Park, Min-Soo;Kang, Chun-Goo;Im, Han-Sang;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.63-67
    • /
    • 2015
  • Purpose Among various causes that influence image quality degradation, various methods for decrease in Artifact occurred by respiration of patients are being used. Among them, this study intended to evaluate CTAC Shift correction method and additional scan compare to the Scan(Q static scan) using respiratory gated system. Materials and Methods This study was conducted on 10 patients, and used PET-CT Discovery 710 (GE Healthcare, MI, USA) and Varian's RPM system. 5.18 Mbq per kg of $^{18}F$-FDG was injected on patients, asked them to take a rest for 1 hour in the bed, and conducted test after urination. Images were visualized through Q static scan, CTAC Shift correction method, Additional scan based on the Whole body scan(WBS) with Artifact. Decrease in Artifact was compared in each image, conducted Gross Evalution, and measured changes of SUVmax. Results For image obtained through the CTAC Shift correction method through WBS with Artifact, 12~56%, Q static scan image showed 17~54% of change rate and Additional Scan showed -27~46% of change rate. In Blind Test, the CTAC Shift correction image showed the highest point with 4 points, Q static scan image showed 3.5 points, and Additional scan image showed 3.4 points. The standardized WBS scan through Oneway ANOVA and three types of Scan method showed significant difference(p<0.05), and did not show significant difference between the three Scan methods(p>0.05). However, the three Scan methods showed significant difference in Blind test. Conclusion Additional scan and Q static scan require more time than the CTAC Shift correction method, there is concern about excessive exposure to patients by CT rescan and Q static scan is difficult to apply on patients with inconsistent respiration or irregular respiration cycle due to pain. For CTAC Shift correction method, limited correction is possible and the range is limited as well. It is considered as a useful method of improving diagnostic value when hospitals use the system appropriately and develop various advantageous factors of each method.

  • PDF

Study for Automatic Exposure Control Technique (AEC) in SPECT/CT for Reducing Exposure Dose and Influencing Image Quality (SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰)

  • Yoon, Seok-Hwan;Lee, Sung-Hwan;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose Auto exposure control (AEC) in SPECT/CT automatically controls the exposure dose (mA) according to patient's shape and size. The aim of this study was to evaluate the effect of AEC in SPECT/CT on exposure dose reduction and image quality. Materials and Methods The model of SPECT/CT used in this study was Discovery 670 (GE, USA), Smart mA for AEC; and $^{99m}Tc$ as a radioisotope. To compare SPECT and CT images by CT exposure dose variation, we used a standard technique set at 80, 100, 120, 140 kVp, 10, 30, 50, 100, 150, 200, 250 mA, and AEC at 80, 100, 120, 140 kVp, 10-250 mA. To evaluate resolution and contrast of SPECT images, triple line phantom and flangeless Esser PET phantom were used. For CT images, noise and uniformity were checked by anthropomrphic chest phantom. For dose evaluation to find DLP value, anthropomorphic chest phantom was used and the CT protocol of torso was applied by standard technique (120 kVp, 100 mA) and AEC (120 kVp, 10-250 mA). Results When standard and AEC were applied, the resolutions at SPECT images with attenuation correction (AC) were the same as FWHM by center 3.65 mm, left 3.48 mm, right 3.61 mm. Contrasts of standard and AEC showed no significant difference: standard 53.5, 29.8, 22.5, 15.8, 6.0, AEC 53.5, 29.6, 22.4, 15.7, 6.1 In CT images, noise values at standard and AEC were 15.4 and 18.5 respectively. The application of AEC increases noise but the value of coefficient variation were 33.8, 24.9 respectively, obtaining uniform noise image. The values of DLP at standard and AEC were 426.78 and 352.09 each, which shows that the application of AEC decreases exposure dose more than standard by approximately 18%. Conclusion The results of our study show that there was no difference of AC in SPECT images based on the CT exposure dose variation at SPECT/CT images. It was found that the increased CT exposure dose leads to the improvement of CT image quality but also increases the exposure dose. Thus, the use of AEC in SPECT/CT contributes to obtaining equal AC SPECT images, and uniform noise in CT images while reducing exposure dose.

  • PDF

Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image (뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가)

  • Lee, Choong Woon;You, Yeon Wook;Kim, Yong Keun;Weon, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.23-27
    • /
    • 2018
  • Purpose The introduction of bone scan has been reported as a useful tool in the diagnosis, treatment, and treatment response of skeletal disease. The purpose of this study is to improve the anatomical information and tolerance of the bone by combining bone scan and pelvic X-ray without additional radiation exposure. Materials and Methods From November 2015 to August 2016, 236 patients(64 men and 172 women, average age $50.96{\pm}15.39years$) take Bone scan and Pelvis AP(Anteroposterior) X-ray scan at the National Cancer Center. The scan equipment was a gamma camera, Symbia Ecam (SIEMENS, Germany), and a digital x-ray, DRS-800 (Listem, Korea). Osirix version 3.8.1 (Osirix, USA) and Stata/SE version 14.0 (StataCorp, USA) were used for image combination and analysis. The patient was intravenously injected with $^{99m}Tc-DPD$ (740 MBq), and the scan was performed 2 to 4 hours later. Gamma camera image acquisition were Matrix size $256{\times}1024$, Zoom 1.00, and scan speed 17 cm/min. The digital X-ray was made with a collimator size of $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp (60 to 97 kVp) and an average of 30 mAs (20 to 48). ASIS and pubic symphysis Select virtual points then Combine three virtual points and pelvic contour lines. The acquired images were evaluated by three radiologists who worked for more than 5 years in the nuclear medicine department. Results Of the total 236 patients, 216 (91.53%) were matched. The median and range (min~max) of the age were 67 (46~81) years old in the unmatched group and 52 (22~87) years old in the matched group, The Wilcoxon rank-sum test was performed to determine whether age was different between the two groups. As a result, the age difference between the two groups was statistically significant at p < 0.0001. Of the 64 men, 60 (93.75%) were match and of the 172 women, 156 (93.75%) were match. There was no statistically significant difference according to gender(p = 0.4542). Of the 54 patients without pelvic lesions, 54 (100.00%) were match, and 162 (89.01%) of 182 patients with pelvic lesions were match. There was a statistically significant difference according to the presence of pelvic lesions. Conclusion There are many variables in the combination of bone scan and pelvic X-ray imaging, and the patient's age and pelvic lesion may have some effect on the image combination. This study is expected to be useful for the diagnosis of pelvic osteosarcoma of children without radiation exposure. It is expected that this combination of images will help to develop the nuclear medicine image.

Congenital Urinary Tract Anomalies Associated with Urinary Tract Infection in Infants and Children (요로감염증과 연관된 방광요관역류 이외의 선천성 요로계 이상에 관한 고찰)

  • Chung So-Hee;Kim Jung-Sim;Kim Hyun-Jung;Lee Mi-Na;Uhm Mee-Ryung;Jin Dong-Kyu;Shin Hwa-Sook
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.180-186
    • /
    • 1999
  • Purpose : It has been well known that urinary tract infection(UTI) in infants and children is frequently associated with vesicoureteral reflux(VUR). However, the publishied papers dealing with congenital anomalies associated with UTI emphasized the importance of VUR only. The aim of our study was to evaluate the type, incidence and spectrum of urologic anomalies associated with UTI. Methods : Medical records of clinical, bacteriologic and radiologic study were assessed retrospectively in 65 infants or children with documented UTI who were admitted to the Department of Pediatrics, Samsung Seoul Hospital from March 1996 to February 1998. Results : Spectrum of anomalies were associated with UTI as follows: VUR(n=23), both ectopic kidney(n=1), ureterovesical junction(UVJ) obstruction(n=1), multicystic dysplastic kidney(n=1), ureteropelvic junction(UPJ) obstruction with hydronephrosis(n=1), hutch diverticulum(n=1), UPJ stenosis(n=1), posterior urethral valve(n=1), urachal remnant(n=1) and bladder diverticula(n=1). Congenital urinary anomalies other than VUR were detected in 9 children among 65 patients with UTI(13.8%). 4 children among 9 congenital urinary anomalies other than VUR were combined with VUR. Sex distribution with congenital urinary anomalies other than VUR was more prevalent in male than female (7 males : 2 females). Age distribution at the time of UTI was less than 5 years in most patient (under 1 year in 1 patient, 1-2 year in 5 patients, 3-5 year in 1 patient, and above 5 year in 2 patients). And age distribution at the time of UTl associated with VUR was less than 5 years in most patient (under 1 year in 6 patients, 1-2 year in 8 patients, 3-5 year in 5 patients, and above 5 year in 4 patients), too Conclusion : Because congenital urinary anomalies other than VUR are seen in as high as 13.8% of patients, more careful evaluation of all possible congenital urinary anomalies as well as VUR is mandatory in pediatric patient with UTI.

  • PDF

Efficacy and Cost Benefits of Rapid Antigen Detection Test for Group A Streptococci Obtained from Acute Pharyngitis in Children (소아 세균성 인두 편도염의 진단에 있어 신속 항원 검출 검사의 유용성과 비용 효과의 평가)

  • Youn, Suk;Chung, Hye-Jeon;Kim, Yun-Ho;Choi, Jin-Dong;Lee, Sang-Hoon;Min, Jung-Sik;Jung, Sang-Young;Jung, Sung-Ki;Ahn, Byung-Moon;Lee, Hee-Joo;Cha, Sung-Ho
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.2
    • /
    • pp.124-134
    • /
    • 2005
  • Purpose : It has been known that the diagnostic confirmation of group A streptococcal pharyngitis is accompanied with the results of throat culture and/or rapid antigen detection test(RADT). This study was designed to evaluate the usefulness and cost benefits of the RADT in patients with a sore throat compared the empirical antibiotic treated group without using RADT or throat culture with the antibiotic treated group according to the results of RADT test and/or throat culture. Methods : From April 2003 to August 2003, total 369 patients were enrolled this study. They were redistributed into two groups. In one group, the RADT test and throat culture were used and the patients received antibiotic treatment according to the results of test and in the other group, no diagnostic examinations were used and the patients were treated with antibiotics which were chosen empirically. The flow sheet with questionnaire was drawing up and obtained the clinical symptoms, signs and the name of antibiotics that were administered. Results : A total of 244 patients were treated after the throat culture and/or RADT, and 125 patients were treated empirically. The prevalence of bacteriologically confirmed group A streptococcal pharyngitis was 20.1%. The sensitivity and specificity of RADT were 89.8% and 86.1%, respectively. Positive predictive value and negative predictive value were 62.0% and 97.1%, respectively. The rate of antibiotic use was high in both groups. Because the physician used the antibiotics even if the result of RADT was negative. So about 37% of reduction of antibiotics use might be possible if we used antibiotics according to the results of RADT. There were no cost differences between the RADT applied group and the empirically treated antibiotic group if we could reduce the price of RADT to 63% of the current price. Conclusion : The RADT could be applied for the easy and rapid diagnosis and prompt treatment for group A streptococcal pharyngitis, and RADT could reduced the number of antibiotics used if the price of RADT was reduced to 63% of current price. For accurate evaluation of efficacy and cost effect, further controlled study is needed.

  • PDF

The Study of IgG subclasses in Acute stage of Kawasaki Disease (급성기 가와사끼병 환아의 IgG 아형항체에 대한 연구)

  • Kim, Minshik;Kim, Youngsook;Cho, Namji;Kim, Kyungsook
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.1
    • /
    • pp.140-149
    • /
    • 1997
  • Purpose : Kawasaki Disease(KD) is a febrile disease with acute multisystemic vasculitis which is seen commonly in early childhood. The cause and etiologic agents are still unknown to identify using ordinary bacterial and viral culture, but the clinical labaratory studies suggest that KD is one of autoimmune disorder caused by infectious agents, but that is not proved yet. The study was performed to investigate the IgG subclasses in acute stage of KB before treatment of IVIG(Intravenous immunoglobulin). Method : The 35 cases in acute stage of KD before treatment of IVIG who were hospitalized from jan. 1995 to dec. 1996. The obtained sera were measured level of total IgG, IgM, IgA, IgE and IgG subclasses IgGl, IgG2, IgG3, IgG4 by using EIA and SRID method. Results : 1) The sex ratio is male to female is 1.5: 1.0, and male is prone to infected. 2) Total IgG, IgM, IgA and IgE level is normal range with age adjusted, but few cases are shown slight high level of total IgG compare to normal range of age adjusted. 3) acute phage reactants such as CRP, C3, ESR are all increased in acute stage of cases. 4) IgG subclasses IgGl, IgG2, IgG3 are shown normal range of age adjusted, but remarkably low level of IgG4 in all of cases. Conclusions : The low level of IgG4 is able to increasing the incidence of KD, and may use early diagnostic tools combine with other clinical symptoms and signs. But the resulsts of reported studies are different to each other, so it needs more times and cases to get final evaluation of changes of serum immnunoglobulin levels correlate to increase the incidence of high risk group of KD patients.

  • PDF

Improved Image Quality and Radiation Dose Reduction in Liver Dynamic CT Scan with the Protocol Change (Liver CT 검사에서 프로토콜 변화에 따른 선량 감소와 영상의 질 개선에 관한 연구)

  • Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.107-114
    • /
    • 2015
  • The purpose is reducing radiation dose while maintaining of image quality in liver dynamic CT(LDCT) scan, by protocols generally used and the tube voltage set at a low level protocol compared to the radiation dose and image quality. The target is body mass index, 18.5~24 patients out of 40 patients who underwent the ACT(abdominal CT). Group A(tube voltage : 120kVp, SAFIRE strength 1) of 20 people among 40 people, to apply the general abdominal CT scan protocol, group B(tube voltage : 100kVp, apply SAFIRE strength 0~5) was 20 people, set a lower tube voltage. Image quality evaluation was setting a region of interest(ROI) in the liver parenchyma, aorta, superior mesenteric artery (SMA), celiac trunk, visceral fat of arterial phase. In the ROI were compared by measuring the noise, signal to noise ratio(SNR), contrast to noise ratio(CNR), CT number. In addition, qualitative assessments to evaluate two people in the rich professional experience in Radiology by 0-3 points. We compared the total radiation dose, dose length product(DLP) and effective dose, volume computed tomography dose index(CTDIvol). The higher SAFIRE in the tube voltage 100 kVp, noise is reduced, CT number was increased. Thus, SNR and CNR was increased higher the SAFIRE step. Compared with the tube voltage 120kVp, noise, SNR, CNR was most similar in SAFIRE strength 2 and 3. Qualitative assessment SAFIRE strength 2 is the most common SAFIRE strength 2 the most common qualitative assessment, if the tube voltage of 100kVp when the quality of the images better evaluated was SAFIRE strength 1. Dose was reduced from 21.69%, in 100kVp than 120kVp. In the case of a relatively high BMI is not LDCT scan, When it is shipped from the factory tube voltage is set higher, unnecessary radiation exposure when considering the reality that is concerned, when according to the results of this study, set a lower tube voltage and adjust the SAFIRE strength to 1 or 2, the radiation without compromising image quality amount also is thought to be able to be reduced.

Developing a Model for Crime Prevention Hardware Performance Test and Certification System (방범하드웨어의 침입범죄 저항성능 시험·인증 체계에 관한 모형 연구)

  • Park, Hyeon-ho
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.255-292
    • /
    • 2013
  • Burglary (also called breaking and entering and sometimes housebreaking) is a crime, the essence of which is illegal entry into a building for the purposes of committing an offence. It is one of the most common types of crime and also a serious issue for every society. A house that is left insecure is an accessible and attractive target for burglars and therefore burglary resistance test & certification system for doors and windows has been developed in many countries. This paper explores several advanced foreign burglary resistance test/certifcation cases (the British SBD, the Dutch KOMO SKH/SKG, the Japanese CP mark, the Australian Standard Certification) for security products and domestic test/certification systems for fire safety products as a comparative study so that any improvement points can be gained for South Korea in the field of security product performance. The comparative analysis results show that South Korea is far behind the security product certification system and needs a lot of improvement in the system by benchmarking foreign cases. The domestic test/certification systems for fire safety products also give some insights for burglary-related security products' performance certification system in Korea. Overall, the need for relevant rules and regulations, the establishment of standards regarding testing and certification, including certified security +hardware product in building security certification system, performance testing as well as production testing (i.e. quality management system evaluation), the basic competency of testers, incentive system for certified/high quality security products were suggested in order to make an optimal model for the security production performance testing and certification system in Korea.

  • PDF

A Study on Characteristics of Hydraulic Conductivity in the Soil-Bentonite Mixed Soils with Compaction Energy and Swelling in the Landfill (폐기물매립장에서 다짐에너지와 팽윤도에 의한 토양-벤토나이트 혼합토의 투수계수 특성에 관한 연구)

  • 이종민;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.61-72
    • /
    • 2001
  • A barrier liner system is placed at the bottom and side slope in landfill to protect a leaking of leachate that the hydraulic conductivity of this system should be less than It 107cm/sec. In this study, the soil-bentonite mixture for the bottom liner system was evaluated in two point of views : changing characteristics of the hydraulic conductivity according to the different mixing ratio of soil-bentonite with the effect of bentonite swelling and the difference method (A & D type) of compaction on the hydraulic conductivity. As the results, maximum dry density (${\gamma}$$_{dmax}$) of SC group mixture was higher than of CL group mixture. However, the result of optimum moisture contents(OMC) of both groups were the contrary. In case of ${\gamma}$$_{dmax}$ by different compaction method, D type was higher than A. But the OMC were the contrary. The difference of ${\gamma}$$_{dmax}$ according to the Compaction energy, “SC” group mixture W3S higher than the “CL” group. In case of OMC of “CL” group was higher than “SC” group. The effecting of swelling was a little bit different on the two factors. According to the result of compaction test, the use of site soil only could not meet the criteria on hydraulic conductivity, but could find a solution for the mixing ratio of bentonite mixture were satisfied to the standard of barriation. The increased in bentonite mixing ratio and degree of swelling, the values of hydraulic conductivity were decreased. Especially the “CL” group with “D” type compaction measured the lowest value with the same conditions. Also, the bentonite mixing ratio has more influenced on the hydraulic conductivity compare with swelling effect. The “SC” group mixture with “A” typo compaction got a big difference from others. The evaluation of economic for the construction cost on the two cases, the lower bentonite mixing ratio of soil-bentonite mixed soil is more economically because of bentonite cost.

  • PDF

Evaluation of CO2 Emission to Changes of Soil Water Content, Soil Temperature and Mineral N with Different Soil Texture in Pepper Cultivation (고추재배에서 토성별 토양수분, 토양온도, 무기태질소 변화에 따른 CO2 배출량 평가)

  • Kim, Gun-Yeob;Song, Beom-Heon;Hong, Suk-Young;Ko, Byong-Gu;Roh, Kee-An;Shim, Kyo-Moon;Zhang, Yong-Seon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.6
    • /
    • pp.393-398
    • /
    • 2008
  • Several researchers have proposed models or equations to predict soil $CO_2$ flux from more readily available biotic and abiotic measurement. Tree commonly used abiotic variables were N mineral and soil temperature and soil water content. This study was conducted to determine $CO_2$ emission to mineral N, soil water content and soil temperature with clay loam and sandy loam in pepper cultivation in 2004~2005. $CO_2$ flux in the upland with different levels of soil water potential was measured at least once in two weeks during the cropping period in the pepper cultivation plots. Soil water potential in the clay loam and sandy loam soils was established at -30kPa and -50kPa by measuring the soil gravimetric water content with two replications. $CO_2$ emission rate from the differently managed plots was highly correlation coefficient to between the mineral N ($R=0.830^{**}$, $0.876^{**}$) and soil temperature ($r^2=0.793^{**}$, $0.804^{**}$) in the clay loam and sandy loam, respectively. However, the relationships between $CO_2$ emission and soil water content were non-significant. $CO_2$ emissions at sandy loam soils was lower to 21~37% than at clay loam soils for both soil water conditions without differences in yield. At difference levels of soil water conditions, $CO_2$ emission at -50kPa decreased to 37.5% in comparison with that at -30kPa. From the path analysis as to contribution factors of GHGs, it appeared that contribution rate was in the order of soil temperature (54.9%), mineral N (32.7%), and soil moisture content (12.4%).