• Title/Summary/Keyword: IT Techniques

Search Result 13,815, Processing Time 0.057 seconds

Bionomics and a Lana Sampling Method of Coppery Wireworm, Selatosomus puncticollis (Motschulsky), (Coleoptera: Elateridae) in Potato Field (청동방아벌레(Selatosomus puncticollis Motschulsky)의 생태적 특성 및 감자포장내 유충밀도 조사법)

  • Kwon, Min;Park, Cheon-Soo;Lee, Seung-Hwan
    • Korean journal of applied entomology
    • /
    • v.43 no.3 s.136
    • /
    • pp.195-200
    • /
    • 2004
  • The occurrence pattern and bionomics of Selatosomus puncticollis (Motschulsky) were surveyed in three net house (6$\times$70m) in the field and in a laboratory ($20^{\circ}C$, RH$75\%$, L16/DB). Emergence of hibernated adults of S. puncricollis started from early May, reached peak at early June and diminished in late June. Occurrence rate to total number was $42.1\%$ in early June and $31.7\%$ in late May, when most of hibernated adults emerged at these periods. Adults started to oviposit from mid June, and eggs hatched from early July Larvae turned into pupae from mid July and emerged to adults from mid August. Egg-period was 23 days and pupal period was 21 days. It is estimated that preovipositional period and larval period were approximately 10 months and 30 months, respectively. Wireworms were distributed at the soil depth of 10-5 cm, $56.8\%$ in 1997 and $45.8\%$ in 1998. To establish bait techniques to attract wireworms in the soil, six baits: pieces of potato, carrot, and sweet potato, wheat grains, corns, and flour dough wrapped with gauze, were buried at 15 cm of soil depth, and collected after 5 and 10 days. The numbers of wireworms attracted by potato pieces, wheat grains and sweet potato pieces after 10 days were 1.8, 1.6, and 1.4/bait, respectively. Therefore, burying potato pieces at 15 cm of soil depth and collected after 10 days could be recommended as a wireworm baiting technique.

Quantitative Micro-CT Evaluation of Microleakage in Composite Resin Restorations (Micro-CT를 이용한 복합 레진 수복물 미세 누출도의 정량 분석)

  • Lee, Sang-Ik;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.222-233
    • /
    • 2007
  • One of the most important and basic test of dental restorative materials is the evaluation of microleakage into the tooth-restorative interface. There are many techniques to test microleakage, but most of them have several disadvantages. Recently developed microtomography(micro-CT) can provide the three dimensional image and information about the internal component in non-destructive way, therefore using micro-CT, it is possible to evaluate microleakage exactly in quantitative manner. The purpose of this study is to find a new method for quantitative and non-destructive evaluation of microleakage in composite resin restorations using micro-CT and to compare the new method with conventional dye penetration method. Thus, microleakages of two kinds of dentin bonding systems were evaluated with above two methods. 40 extracted sound human premolars were randomly divided into two groups consisting of 20 samples and restored accordingly. Group 1 : Class V resin restorations with $Adper^{TM}$ Singe Bond Group, 2 : Class V resin restorations with $Adper^{TM}\;Promp^{TM}$ L-pop. The $Filtek^{TM}$ Supreme was applied to the Class V cavities of all teeth. After that, 10 teeth from each group were applied to evaluation of microleakage using micro-CT, and other 10 teeth from each group were using conventional dye penetration method. The conclusions of this study were as follow : 1 Using micro-CT, Group 1 showed significantly less microleakage than Group 2 and there was statistically significant difference(p<0.01) between two groups. 2. Using conventional dye penetration method, Group 1 leaked less than Group 2 and there was statistically significant difference(p<0.01) between two groups 3. The difference between two groups is more evident in the method using micro-CT. 4. In all two methods, microleakage appeared more into the cavities to dentinal margins than enamel margins.

  • PDF

Microassisted Fertilization of Human Oocytes with Intracytoplasmic Sperm Injection in IVF-ET Patients with History of Failure in Fertilization or Extremely Low Fertilization Rate in Previous Cycles (미수정 및 저수정율의 기왕력을 지닌 체외수정시술 환자에서의 난자 세포질내 정자 주입술을 이용한 미세보조 수정술에 관한 연구)

  • Moon, Shin-Yong;Kim, Seok-Hyun;Chae, Hee-Dong;Kim, Kwang-Rye;Lee, Jae-Hoon;Kim, Hee-Sun;Ryu, Buom-Yong;Oh, Sun-Kyung;Suh, Chang-Suk;Choi, Young-Min;Kim, Jung-Gu;Lee, Jin-Yong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.1
    • /
    • pp.83-93
    • /
    • 1997
  • Although IVF-ET is widely applied in the treatment of couples with male factor infertility, it may fail in many infertile couples with normal semen parameters, and certain couples cannot be accepted for standard IVF-ET due to unfertilization or extremely low fertilization rate of oocytes. Recently, several procedures of microassisted fertilization (MAF) using micromanipulation have been introduced, and pregnancies and births have been obtained after partial zona dissection (PZD), subzonal insertion (SUZI), and intracytoplasmic sperm injection (ICSI). This clinical study was performed to develop and establish ICSI as an effective procedure of MAF in infertile couples who could not undergo standard IVF-ET repetitively because of failure in fertilization or extremely low fertilization rate of oocytes with the conventional fertilization technique in the previous IVF-ET cycles. From March, 1995 to May, 1996, 27 cycles of IVF-ET with ICSI in 19 infertile patients were included in study group, and the outcomes of ICSI were analyzed according to fertilization rate, cumulative embryo score (CES), and pregnancy rate. The number of oocytes retrieved after controlled ovarian hyperstimulation (COH) was $10.50{\pm}6.13$ in 30 previous cycles, and $10.57{\pm}5.53$ in 27 ICSI cycles. In ICSI cycles, the number of oocytes optimal for ICSI procedure was $7.89{\pm}4.30$, and the fertilization rate of $67.9{\pm}20.2%$ could be obtained after ICSI. The number of embryos transferred was $1.43{\pm}2.40$ in previous cycles, and $4.36{\pm}1.77$ with the mean CES of $41.8{\pm}27.4$ in ICSI cycles. In ICSI cycles, the overall pregnancy rate was 29.6% (8/27) per cycle and 42.1% (8/19) per patient with the clinical pregnancy rate of 22.2% (6/27) per cycle and 31.6% (6/19) per patient. In conclusion, MAF of human oocytes with ICSI is a promising fertilization method for IVF-ET patients, especially with the past history of failure in fertilization or low fertilization rate of oocytes in the previous IVF-ET cycles, and ICSI using micromanipulation procedures applied to human oocytes will provide a range of novel techniques which may dramatically improve the pregnancy rate in IVF-ET program and contribute much to effective management of infertile couples.

  • PDF

Arthroscopic Retrieval Analysis for Intra-articular Foreign Body of the Knee Joint (슬관절내 이물질에 대한 관절경적 제거술식의 분석)

  • Lee, Byung-Ill;Choi, Hyung-Suk;Jo, Joo-Hyoung;Kwon, Sai-Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.211-216
    • /
    • 2008
  • Purpose: The frequency of foreign body in the knee joint is not as high, but it sometimes required wide or multiple arthrotomy in order to remove, which can baffle the surgeon in some ways. Our study is to evaluate for effectiveness of arthroscopic retrieval for intra-articular foreign body in the knee joint. Materials and Methods: The 22 patients(16 males, 6 females) had received arthroscopic foreign body retrieval in the knee joint from March 1983 to September 2006. The causes of foreign bodies of the knee joint were 7 of trauma (31.9%) related cases, 13 of surgery related cases (59.0%), 2 found during follow up after operation (8.1%) in pathologies of foreign body. Results: There were 15 of metal showed the most percentage (68.1%), 7 of non-metal (31.9%) in types of foreign bodies, and others included bullet, suture material, pencil lead, broken wire etc. All cases were used by arthroscopic techniques. All foreign bodies were removed easily and were showed no complication such as postoperative joint stiffness. Conclusion: Arthroscopic foreign body retrieval in the knee joint is effective surgery in terms of easy access to foreign body and less postoperative complication.

  • PDF

Tracheal Reconstruction with Perichondrial Graft - An Experimental Study in Rabbits - (연골피막편 이식후 기관 결손부위의 재생에 관한 실험적 연구(제 1 보))

  • 이원상;서장수;이성은;홍원표;박찬일
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.10.3-11
    • /
    • 1982
  • Recently through the advancement of medical and surgical managements and the development of low pressure cuffed endotracheal tube, incidence of tracheal stenosis was decreased significantly. Though its incidence was decreased markedly, stenosis was developted unfortunately in the situations such as long term use of respirator, heavy infection, trauma of the trachea and long term intubation etc. Tracheal stenosis had been handled with various methods such as mechanical dilatation, tissue graft techniques, luminal augumentation and end to end anastomosis due to their individual advantages but their effects were not satisfactory. In 1959 Lester had been found the regenerated cartilage from the perichondrium of the rib incidentaly. Since then Skoog, Sohn and Ohlsen were reported chondrogenic potential of perichondrium through the animal experiments. Though many different materials have been tried to rebuild stenosis and gaping defect of trachea, tracheal reconstruction has been a perplexing clinical problems. We choose the perichondrium as the graft material because cartilage is the normal supporting matrix of that structure and it will be an obvious advantage to be able to position perichondrium over a defect and obtain new cartilage there. The young rabbits, which were selected as our experimental animals, were sacrified from two to eight weeks after surgery. The results of our experiment were as follows; 1) In control group, the defect site of trachea was covered with fibrosis and vessels but graft site was covered with hypertrophied perichondrium and vessels. 2) Respiratory mucosa was completely regenerated in defect sites both control and grafted groups. 3) The histologic changes of the grafted sites were as follows: 2 weeks- microvessel dilatation, inflammatory reaction, initiation of fibrosis 4 weeks- decreased microvessel engorgement, submucosal fibrosis, decreased inflammatory reaction immatured cartilage island was noted in the grafted perichondrium (one specimen) 6 weeks- mild degree vascular engorgement submucosal fibrosis. chronic inflamatory reaction cartilage island and endochondrial ossification was noted in the grafted perichondrium (Two specimens) 8 weeks- minute vascular engorgement dense submucosal fibrosis. loss of inflammatory reaction. cartilage island was noted in the grafted perichondrium (two specimens) 4) There was no significant differences in regeneration between active surface in and out groups. 5) We observed immatured cartilage islands and endochondrial ossification in the perichondrial grafted groups where as such findings were not noted in control groups except fibrosis. We concluded that perichondrium was the adequate material for the reconstruction of defected trachea but our results was not sufficient in the aspect of chondrogenic potential of perichondrium. So further research has indicated possibility of chondrogenic potential of perichondrium.

  • PDF

Removal Efficiency of Ammonia and Toluene using Mobile Scrubber (이동형 스크러버를 이용한 암모니아 및 톨루엔의 제거 효율)

  • Kim, Jae-Young;Kim, Jang-Yoon;Lee, Yeon Hee;Kim, Min Sun;Kim, Min-Su;Kim, Hyun Ji;Ryu, Tae In;Jeong, Jae Hyeong;Hwang, Seung-Ryul;Kim, Kyun;Lee, Jin Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2018
  • BACKGROUND: The mobile vortex wet scrubber was developed to remove the harmful chemicals from accidental releases. However, there was a disadvantage that it was limitedly used for volatile organic compounds (VOCs) such as toluene according to the physicochemical properties. This study compared the removal efficiencies of an improved mobile scrubber on toluene and ammonia by applying diverse adsorption and absorption methods. METHODS AND RESULTS: The removal efficiencies on harmful chemicals were examined using various adsorption and absorption methods of water vortex process (C), phosphoric acid-impregnated activated carbon adsorption (PCA), pH-controlled water (pH 2.5) vortex process absorption with sulfuric acid (SWA) after ammonia exposure, granular activated carbon adsorption (GCA), and activated carbon mat adsorption (CMA) after toluene exposure. As a result, the best removal efficiency was shown in the SWA for ammonia and GCA for toluene. Also, the SWA and GCA methods were compared with different concentration levels. In the case of ammonia exposure (5, 10 and 25%), there was no difference by concentration levels, and the concentration in the outlet gradually increased, with pH change from acid to base. In the case of toluene exposure (50, 75 and 100%), the outlet concentration was higher relative to the exposure concentration in the initial 10 min, but the outlet concentration was remained steady after 10 min. CONCLUSION: The newly improved mobile scrubber was also effective in removing VOCs through adsorption techniques (activated carbon, activated carbon fiber, carbon mat filter etc.), as well as removing acid-base harmful chemicals by neutralization reaction.

Fusion of Gamma and Realistic Imaging (감마영상과 실사영상의 Fusion)

  • Kim, Yun-Cheol;Yu, Yeon-Uk;Seo, Young-Deok;Moon, Jong-Woon;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.78-82
    • /
    • 2010
  • Purpose: Recently, South Korea has seen a rapidly increased incidence of both breast and thyroid cancers. As a result, the I-131 scan and lymphoscintigraphy have been performed more frequently. Although this type of diagnostic imaging is prominent in that visualizes pathological conditions, which is similar to previous nuclear diagnostic imaging techniques, there is not much anatomical information obtained. Accordingly, it has been used in different ways to help find anatomical locations by transmission scan, however the results were unsatisfactory. Therefore, this study aims to realize an imaging technique which shows more anatomical information through the fusion of gamma and realistic imaging. Materials and Methods: We analyzed the data from patients who were examined by the lymphoscintigraphy and I-131 additional scan by Symbia Gamma camera (SIEMENS) in the nuclear medicine department of the National Cancer Center from April to July of 2009. First, we scanned the same location in patients by using a miniature camera (R-2000) in hyVISION. Afterwards, we scanned by gamma camera. The data we obtained was evaluated based on the scanning that measures an agreement of gamma and realistic imaging by the Gamma Ray Tool fusion program. Results: The amount of radiation technicians and patients were exposed was generated during the production process of flood source and applied transmission scan. During this time, the radiation exposure dose of technicians was an average of 14.1743 ${\mu}Sv$, while the radiation exposure dose of patients averaged 0.9037 ${\mu}Sv$. We also confirmed this to matching gamma and realistic markers in fusion imaging. Conclusion: Therefore, we found that we could provide imaging with more anatomical information to clinical doctors by fusion of system of gamma and realistic imaging. This has allowed us to perform an easier method in which to reduce the work process. In addition, we found that the radiation exposure can be reduced from the flood source. Eventually, we hope that this will be applicable in other nuclear medicine studies. Therefore, in order to respect the privacy of patients, this procedure will be performed only after the patient has agreed to the procedure after being given a detailed explanation about the process itself and its advantages.

  • PDF

The Usefulness of Q.Clear Technique in PET / CT (PET/CT 검사에서 Q.Clear 기법의 유용성에 대한 고찰)

  • Choi, Yong Hoon;Kim, Jung Yul;Choi, Young Sook;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.31-36
    • /
    • 2017
  • Purpose Recently, the performance of PET/CT scanner has been improved and various techniques have been developed to increase the image quality such as Sensitivity and Resolution. The purpose of this study is to evaluate the usefulness of Q.Clear (a fully convergent iterative reconstruction) technique of GE Discovery IQ equipment to enhance the image quality. Materials and Methods All scans were acquired by Discovery IQ (GE Healthcare, MI, USA). In NEMA IEC Body Phantom test, Background to Hot-sphere (10 mm, 13 mm, 17 mm, 22 mm) ratio was 1:4 and scan time was 3 minutes. The images were reconstructed by VPHDs (VUE Point High-Definition + SharpIR) and Q.Clear to evaluate each Contrast. We injected 18F-FDG 187 M㏃ to PET/SPECT Performance Phantom. And then it was scanned for 4 minutes to evaluate Resolution and Uniformity. T-test statistical analysis was performed on SUVmax of small lesions less than 2 cm in 100 clinical patients regardless of disease type. Results In the NEMA IEC Body Phantom, the Contrast was $63.6{\pm}5.7%$ (VPHDs) and $75{\pm}4.8%$ (Q.Clear). In the PET/SPECT Performance Phantom, the Resolution was 9.2 mm (VPHDs) and 7.3 mm (Q.Clear). Uniformity of Q.Clear was 10.8% better than VPHDs. T-test statistic of the clinical patients showed a significant difference of p value of 0.021. Conclusion Both the phantom test and the clinical results showed that the quality of the image was improved in Q.Clear was applied. The SUVmax was highly measured in Q.Clear and the lesions were clearly distinguished visually. Therefore Q.Clear can be useful in various aspects such as dose-reduction, patients evaluation and image analysis.

  • PDF

Motion Reduction Activities in Patients undergoing Myocardial Perfusion SPECT with the Discovery NM 530c(D530c) (Discovery NM 530c(D530c)에서 촬영한 심근관류 SPECT 환자의 움직임 감소활동을 위한 연구)

  • Lee, Dong Hun;Choi, Woo Jun;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.80-85
    • /
    • 2017
  • Purpose The D530c have cadmium zinc telluride(CZT) detectors that are arranged focus on the heart. This structural characteristic allows for quicker imaging without rotation, but this is sensitive to patient movement and can affect the test results. The aim of this study is to optimize the image quality by reducing patient movement during the examination. Materials and Methods We analyzed the patients' movements, and performed various activities such as provided patient education about correct breathing techniques and avoiding patient movements, and created breathing correction tools to minimize patient movement during exam. The 70 patients who underwent myocardial perfusion SPECT with D530c in November 2016 were categorized as the group before the corrective steps. Another 70 patients who underwent the procedure with D530c from February 14, 2017 to February 21, 2017 were categorized as the improvement group. Images acquired during stress and at rest were compared and analyzed by measuring the durations of heart movements over certain distances (4 mm, 8 mm, 12 mm, or more) noted on the x-, y-, and zaxes. Results After the activities, the durations of heart movements decreased in the images acquired both under stress and at rest. In particular, there were no large motions greater than 12 mm recorded in the stress images after the improvement. There was a significant difference (p<0.005) in the 4-mm and 8-mm fluctuations on the X-axis and the 8-mm fluctuations on the Z axis in the stress images, but there was no significant difference (p>0.005) in the other stress and rest intervals. Conclusion The decrease in the time of motion occurrence due to the 4 mm fluctuation distance that can occur through breathing can be understood as a result of the breathing being corrected through training and motion prevention tools. It is expected that the image quality will be improved by reducing the occurrence time according to the variation distance of 8 mm or 12 mm, which is expected as the actual movement of the patient other than the breathing.

  • PDF

A Role of Trial Radiation Therapy in the Pineal Region Tumors (송과체부 종양에서 시험적 방사선치료의 역할)

  • Kim, Yeon-Shil;Ryu, Mi-Ryung;Chung, Su-Mi;Kim, Moon-Chan;Yoon, Sei-Chul
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.100-107
    • /
    • 2002
  • Purpose : The aim of this retrospective study was to assess the treatment results of 30 patients with pineal region tumors who were underwent radiation therapy under the diagnosis by either CT or MRI. There was no histological verification. We analyzed the prognostic factors that have a significant effect on the overall survival (OS) and disease free survival (DFS) rates. Materials and Methods : A total 30 patients with pineal region tumors were treated between March 1983 and August 1995. After a trial radiation therapy of $20\~30\;Gy/2\~3$ weeks, the patients were evaluated for their clinical response and radiological response by either CT or MRI and the final treatment direction was then decided. According to their response to the trial radiation therapy and the involved site, radiation treatment was given in various fields i.e., local, ventricle, whole brain and craniospinal field. The radiation dose ranged from 40.8 to 59.4 Gy (Median 50.4 Gy). The median follow up was 36.5 months $(4\~172\;months)$. Results : An improvement or stability in the clinical symptoms was observed in 28 patients $(93.3\%)$ after the trial RT. Nineteen patients $(63.3\%)$ showed a partial or complete response by CT or MRI. The two-year and five-year survival rates of the patients were $66.7\%$ and $55.1\%$, respectively. No significant difference in the survival rates according to the degree of the radiological response was abserved after the trial RT. The results of univariate analysis showed that age, the primary site, the performance status $(KPS\geq70)$, the degree of response after completing RT and the RT field were significant prognostic factors affecting the survival and disease free survival rates (p<0.05). Conclusion : The clinical and histological characteristics of pineal region tumors are quite complex and diverse. Therefore, it is difficult to predict the histological diagnosis and the possibility of radiocurability only with the initial response to RT. We think that the development of less invasive histological diagnostic techniques and tailored treatment to the histological type of each tumor are needed.