• Title/Summary/Keyword: IT Field

Search Result 30,841, Processing Time 0.053 seconds

The Development of Magnetic Field Measurement System of 3 Axis (3축 자계 측정 시스템의 개발)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.253-257
    • /
    • 2017
  • Nowadays, it is increasingly important to detect whether cables are live for the operator's safety if there is a sudden power failure. It is especially hard to detect the electrical field of an underground line because of shielding. This paper on detection of live-line states in cables studied the detection characteristics of the change in the magnetic field and axis as the frequency, voltage, and distance at the same load are changed using 3 axes. A search coil type was used as a magnetic field sensor with non-contact. We found that magnetic fields decrease proportionally to the square of the distance and the decrease of rated voltage with load effected to magnetic field. The magnetic field was detected by 3-axis sensors given correct proximity, but appeared as noise components beyond a distance of 2 cm.

Alternating Magnetic Field Crystallization of Amorphous Si Films

  • Kang, K.H.;Park, S.H.;Lee, S.J.;Nam, S.E.;Kim, H.J.
    • Journal of Information Display
    • /
    • v.4 no.1
    • /
    • pp.34-37
    • /
    • 2003
  • We investigate the solid phase crystallization of amorphous Si films on glass substrates under alternating magnetic field induction. The kinetics of crystallization are found to be greatly enhanced by alternating magnetic field. While complete crystallization takes heat treatment of more than 14 hours at 570$^{\circ}C$, it can be reduced by applying the megnetic field to 20 minutes. It is assumed that the enhancement of crystallization is associated with an electromotive force voltage generated by alternating magnetic field. This electric field applied in the amorphous Si may possibly be the reason for acceleration of the atomic mobility of crystallization through the modification of atomic potentials

Development of The New field Analysis System (차세대 전재해석 시스템의 개발)

  • 강종성;고광철;강형부
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.237-241
    • /
    • 1997
  • It is necessary to know the accurate field distribution around the high power apparatus, in designing it. To calculate the field around electrodes, we use the Charge Simulation Method(CSM) among several numerical methods and develop the new \"Field Analysis System\", by which we can draw the shape of electrodes, save the drawing in ascii code and apply CSM on the data. In the Field Analysis System, we try several rules for arrangement of simulation charge on CSM and consider their accuracy. At firs we simulate the case with simple electrode geometry and consider the adequacy of the rules. With tole field Analysis System applied the rules, we simulate the main electrode of load switchgear. As a result of the simulation, equipotential line, flux line and field strength on male electrode are drawn.

  • PDF

3-Dimensional Magnetic Field Analysis of Coil Using Biot-Savart Law Considering Singularity (특이점이 고려된 비오-사바르법을 이용한 3차원 코일의 자계 해석)

  • Song, Ho-Jun;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.104-106
    • /
    • 2005
  • In this paper, 3-dimensional magnetic field of coil is analyzed by using biot-sarvart law considering singularity. The RMSP(reduced magnetic scalar potential) arc employed in order to reduce the number of unknown variables in FEM(Finte Element Analysis) or BEM(Boundary Element Method). It Is necessary to calculate magnetic field of souce current when RMSP is used. Biot-savart law is generally used. it is difficult to calculate the field when the source point is in inside the coil. To integrate using gaussian quadrature, the cross section of coil is divided considering the position of field point when field point is inside coil. The proposed method shows good agreement of magnetic field compared with FEMLAB, OPERA3D.

  • PDF

Experimental study for characteristics of diffuse sound field formed by sound source directivity (음원의 지향성이 확산음장 형성에 미치는 영향에 관한 실험연구)

  • Shin, Il-Seop;Cha, Kwang-Seok;Cho, Chang-Geun;Lee, Dae-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1002-1006
    • /
    • 2000
  • It is diffuse sound field that measuring condition of absorption ratio and sound transmission loss for material consist of building are measured in reverberartion room and on-site. In this study, for upkeeping diffuse sound field in reverberation room, it is measured and etimated that sound field is effected according to sound source lacation and characteristics of emission directivity for sound source.

  • PDF

Magnetic Field correction Using Magnetized Shims (자화 철편을 이용한 초전도 마그넷의 자장 보정)

  • 심기덕;배준한;진홍범;고락길;권영길;류강식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.143-146
    • /
    • 2000
  • Generally, two methods can be used to correct the undesirable magnetic field of MRI. One is active shimming method and the other is passive shimming. Passive shimming method uses many magnetized shims to correct the field. And it involves hardwared for supporting shim trays and a software to calculate a field map and optimaze the locations of the shims[1]. The software is the most important part of the passive shimming system. We made a prototype of the software and tested it in a virtual situation.

  • PDF

Fabrication of Vertically Aligned GaN Nanostructures and Their Field Emission Property

  • Jo, Jong-Hoe;Kim, Je-Hyeong;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.281-281
    • /
    • 2014
  • The field emission properties of GaN are reported in the present study. To be a good field emitter, it requires a low work function, high aspect ratio, and strong mechanical stability. In the case of GaN, it has a quite low work function (4.1eV) and strong chemical/mechanical/thermal stabilities. However, so far, it was difficult to fabricate vertical GaN nanostructures with a high aspect ratio. In this study, we successfully achieved vertically well aligned GaN nanostructures with chemical vapor-phase etching methods [1] (Fig. 1). In this method, we chemically etched the GaN film using hydrogen chloride and ammonia gases at high temperature around $900^{\circ}C$. This process effectively forms vertical nanostructures without patterning procedure. This favorable shape of GaN nanostructures for electron emitting results in excellent field emission properties such as a low turn-on field and long term stability. In addition, we observed a uniform fluorescence image from a phosphor film attached at the anode part. The turn-on field for the GaN nanostructures is found to be about $0.8V/{\mu}m$ at current density of $20{\mu}A$/cm^2. This value is even lower than that of typical carbon nanotubes ($1V/{\mu}m$). Moreover, threshold field is $1.8V/{\mu}m$ at current density of $1mA$/cm^2. The GaN nanostructures achieved a high current density within a small applied field range. We believe that our chemically etched vertical nanostructures are the promising structures for various field emitting devices.

  • PDF

Measurement of Variability of Chlorophyll Contents in Paddy Fields Using Two Kinds of Chlorophyll Meter (2종의 엽록소 측정기를 이용한 포장내 벼의 엽록소 함량 분포 측정)

  • 성제훈;서상룡;박우풍;정인규;김상철;이충근
    • Journal of Biosystems Engineering
    • /
    • v.28 no.3
    • /
    • pp.245-252
    • /
    • 2003
  • This study was investigated the possibility of measuring chlorophyll in paddy crops using two kinds of chlorophyll meters(SPAD-502, Field Scout). The results of correlation analysis showed the 0.7758(r$^2$) relationship between the chlorophyll contents of paddy leaves measured by SPAD and spectrophotometer. It indicates that chlorophyll content in paddy crops could be measured using the SPAD. Considering the data of the SPAD and Field Scout there was significant difference between their chlorophyll contents measured by the SPAD and Field Scout. Likewise, such results were consistent with the corrected data using light intensity. According to the results, it can be concluded that it is difficult to describe the rice chlorophyll measured by the Field Scout more accurately than the SPAD when using one standard spectrum and another spectrum for reflectance measuring. The chlorophyll variance measured at a research institute and a farmer's field revealed that the output of SPAD was more reliable than that of the Field Scout.

Calculation method for settlement of micropile installed in rock layers through field tests

  • Hwang, TaeHyun;Cho, JungMin;Lee, YeongSaeng
    • Geomechanics and Engineering
    • /
    • v.31 no.2
    • /
    • pp.197-208
    • /
    • 2022
  • Micropiles consisting of steel bars and grouts are commonly used in underpinning methods to reinforce supports or to suppress the subsidence of existing structures. Recently, applications in the field of geotechnical engineering have expanded. Despite the increasing use of micropiles are used, the PHC or steel pile formula is still applied for the settlement amount of micropiles. Compared with field test results, the amount of micropile subsidence obtained from the existing method may result in a very large error in the displacement of the micropile. Therefore, it is difficult to utilize micropiles effectively. Hence, to solve this problem, this study evaluated the behaviors and support characteristics of micropiles through field compression and tensile tests, and proposed a method for predicting the amounts of their subsidence. To confirm the appropriateness of the proposed method, field test results and the results obtained using the proposed method were compared. It was found that the settlement amounts of the micropiles as predicted through the existing method were significantly overestimated (error ≈ 50-80%) relative to the field test results, whereas the settlement errors of the piles predicted through the proposed method decreased (error ≈6-32%). Thus, it is possible to reduce the previously overestimated amount of settlement, and the modified method of this study allows more efficient design than the conventional method.

The Study on Development and Applicability of Shotcrete Shotting Test Machine (숏크리트 타설시험기 개발 및 적용성 검토)

  • Kang, Eun-Gu;Ma, Sang-Joon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1333-1342
    • /
    • 2010
  • It required excessive cost and effort to evaluate the quality of shotcrete mix for field test. Also, due to a myriad of field variables, it is difficult to get a standardized result for field test. And it is impossible to simulate the shotting process for indoor test. In this study, in order to overcome these problems, we developed a standardized Shotcrete Shotting Test Machine. Using this machine we performed shotcrete quality test and estimated the applicability of developed Shotcrete Shotting Test Machine by comparing with the results of field test.

  • PDF