• Title/Summary/Keyword: IT Device

Search Result 12,082, Processing Time 0.046 seconds

Scheme for Verification Between Mobile Devices in a Service with Expiration Time by Using Zero-knowledge Proof (영지식 증명을 이용한 가입기간이 정해진 서비스에서 이동 통신 기기간 인증 기법)

  • Park, Young-Hoon;Seo, Seung-Woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.23-32
    • /
    • 2013
  • As the mobile communication technology is developed, the services for communication between the mobile devices are provided, and the amount of usage is increasing tremendously. For the device-to-device communication, the device should be verified if it is a service member. The existing verification schemes include interactions with the third party, while this may cause the problems that the bandwidth is dissipated and the devices which are out of the communication range of the base station cannot communicate with other devices. To solve such problems, we propose a new scheme for verification between mobile devices without interaction of third party. For the proposed scheme, we develop and employ a new zero-knowledge proof protocol, which verifies the device's membership and its expiration time. Furthermore, the scheme guarantees privacy of the mobile device since it checks the encrypted verification message without decrypting, and protects replaying attack since it uses challenge-response method.

High Performance Electroluminescent Display Device with AION-TiON Insulator

  • Lim, Jung-Wook;Yun, Sun-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.932-934
    • /
    • 2003
  • For the insulator of inorganic thin film electroluminescent (TFEL), devices AlON combined with TiON was used and it exhibits higher luminance than AlON as well as $Al_{2}O_{3}$ insulator. Furthermore, using AlON with TiON film show better stability and higher luminance than that with $TiO_{2}$ grown by conventional atomic layer deposition (ALD) for the application of the insulator of ZnS:Mn TFEL device.

  • PDF

Field Test Results of a Spring Type Tensioning Device for Korea Railroad (한국형 스프링식 장력 장치의 현장 시험 결과)

  • Yoon Yong-Han;Yim Geum-Kwang
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.771-776
    • /
    • 2005
  • This paper presents field test results of a spring type tensioning device for Korea railroad. The wheel type tensioning device used in the Korea railroad requires much time and labor for maintenance including wire replacement and oil application. So, we found it necessary to develop a new type of maintenance-free tensioning device. In this paper, we introduced field test results of spring type tensioning devices for Korea railroad.

  • PDF

A CASE REPORT OF COMPLICATIONS DURING MANDIBULAR TRANSVERSE SYMPHYSIS WIDENING (하악 이부 확장술 시 나타나는 합병증의 치험례)

  • Suh, Chung-Whan;Kang, Kyung-Hwa;Choi, Moon-Gi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.480-488
    • /
    • 2008
  • Orthodontists often treat cases which are difficult to treat with conventional orthodontics. In such cases, it could be treated with surgical procedures with the help of an oral surgeon. Especially, transverse deficiency of the mandible can be corrected by widening the transverse width of mandibular symphysis, using distraction osteogenesis. Transverse widening of mandibular sympysis is known as a safe treatment but still complications could occur during the treatment. We are reporting some complications of cases that mandibular symphysis transverse widening were applied. Some cases showed complications because of the inappropriate osteotomy line. Since straight vertical osteotomy line was inclined to the left, only the left bony segment was likely to expand. According to bio-mechanical considerations, it will be better to perform a step osteotomy, cutting the eccentric area of the alveolar crest and the centric area of the basal symphyseal area. Complications could also occur by the failure of the distraction device. The tooth borne distraction device was attached on the lingual side of the tooth with composite resin. During the distraction period, it was impossible to obtain appropriate distraction speed and rhythm because of frequent fall off of the distraction device. Therefore, distraction device should be attached firmly with orthodontic band or bone screw, etc. Tooth mobility increasement could also occur as a complication. 'Walking teeth phenomenon' was observed during the distraction period, showing severe teeth mobility and pain during mastication. These symptoms fade out during the consolidation period. Since the patient could feel insecure and uncomfortable, it should be notified to the patient before the procedure. Finally, alveolar crestal bone loss could occur. Alveolar crestal bone loss occurred because of lack of distraction device firmness and teeth trauma caused by lower lip biting habit. Therefore, adequate firmness of the distraction device and habit control will be needed.

A Study on the Design of a Rotational Force Generator for Molten Metal (용탕 회전력 생성장치의 설계에 관한 연구)

  • Lee, Jun-Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.493-501
    • /
    • 2012
  • A rotational force generator for molten metal is developed using a linear motor design technology. Also, the developed device is applied to reproduce aluminum scraps and easy to control the rotate, stop, and forward and reverse rotation of molten metal. In addition, the developed device improves the melting speed and reproduction rate about 250 (%) and 96-99 (%), respectively, compared to the conventional handmade methods. Because it generates almost no dusts, it can improve working environments in a factory. Also, it has no losses in energy because it directly melts scraps. The device generates small amounts of the loss in refractory materials and aluminum caused by its oxidation because the molten metal is continuously rotated in which the loss and oxidized aluminum are the problems in the conventional melting and holding furnaces. Thus, it is possible to extend the life of furnaces and to produce high quality aluminum products.

The Development of Real-Time Harmonic Analysis Algorithm in Distribution Transformer (배전용 변압기의 실시간 고조파 분석 알고리즘 개발)

  • Park, Chul-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.43-49
    • /
    • 2013
  • Recently harmonics flowing into power system is increasing as the usage of semiconductor equipments and switching mode power equipments are increasing. Harmonics cause problems such as heat increasing and reduction in capacity of transformers, especially the harmonics flowing into a distribution transformer can lead to the lifetime reduction of transformer. In this paper, we are about to develop a device that can monitor harmonics in real-time as it is affixed to a distribution transformer. Unlike the existing expensive harmonic analysis device, a new harmonic analysis algorithm is proposed in order to implement low-cost equipment. The real-time harmonic analysis algorithm proposed in this paper allows implementation on low performance microcontrollers, thus it can monitor the harmonic in real-time as it is individually affixed to the transformer. Therefore, it would improve the reliability of the transformer and stable power system operation would be possible as it can prevent the transformer accidents in advance.

A Study on the Application of Risk Management for Medical Device Software Test (의료기기 소프트웨어 테스트 위험관리 적용 방안 연구)

  • Kim, S.H.;Lee, jong-rok;Jeong, Dong-Hun;Park, Hui-Byeong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.495-497
    • /
    • 2012
  • Development of application risk management for medical device software test. First, Through questionnaires, Medical device manufacturers, Analysis of software validation and risk management status. Second, Analyzed by comparing the difference between black box testing and white box testing. Third, After analyzing the potential for software analysis tools using code derived factors were quantified, Finally, Medical device risk management process so that it can be applied to build the framework by FMEA(Failure Mode and Effect Analysis) technique. Through this Difficult to build software validation and risk management processes for manufacturers to take advantage of support in medical device GMP(Good Manufacture Practice).

  • PDF

New Material Architecture and Its Process Integration for a-Si TFT Array Manufacturing

  • Song, Jean-Ho;Park, Hong-Sick;Kim, Sang-Gab;Cho, Hong-Je;Jeong, Chang-Oh;Kang, Sung-Chul;Kim, Chi-Woo;Chung, Kyu-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.552-555
    • /
    • 2002
  • In order to achieve higher performance and low cost a-Si TFT-LCD panel, new material architecture and its process integration for a-Si TFT array manufacturing method were developed. Material combination of low resistant dry-etchable metal and new pixel electrode under currently adopted 4 mask process made it possible to get more-simplified manufacturing method and better device performance for the a-Si TFT-LCD application. Proposed 4 mask process architecture with optimized wet etchants and dry etching process was applicable to various devices such as notebook, monitor and TV.

  • PDF

Comparison and Evaluation of Real Industry Color(RIC) Device and Spectrophotometer for the Colors of Dyed Fabrics (염색물의 Color에 따른 Real Industry Color(RIC) Device와 측색기의 비교분석 및 평가)

  • Bin, Soyoung;Hwang, Hyejin;Kim, Dongkwon;Park, Yooncheol;Park, Soonyoung;Jang, Eun-Hye;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.26 no.1
    • /
    • pp.39-44
    • /
    • 2014
  • To confirm the performance and benefit of the developed online E-commerce Real Industrial Color(RIC) device, cotton and polyester were dyed with selected 39 colors. The captured images of dyed cotton and polyester by using RIC device were compared with original samples and confirmed ${\Delta}E$ using a spectrophotometer and RIC device. Overall, visual comparison of the captured images was similar to the real dyed samples. In high concentration of dyeings, the color consistency between real samples and captured images was better than in lower color concentration of dyeings. Similarly, the result was almost the same when the developed RIC device was used since ${\Delta}E$ values of RIC device were smaller compared with spectrophotometer. In this regards, the RIC device developed up to date can be assumed that it is more influenced by the color rather than fabric materials.

A New Approach to On-Line Monitoring Device for ZnO Surge Arresters

  • Lee Bok-Hee;Gil Hyoung-Jun;Kang Sung-Man
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.131-137
    • /
    • 2005
  • This paper describes a new approach to the algorithm and fundamental characteristics of the device for monitoring the leakage currents flowing through zinc oxide (ZnO) surge arresters. In order to obtain a technique for a new on-line monitoring device that can be used in the deterioration diagnosis of ZnO surge arresters, the new algorithm and on-line leakage current detection device for extracting the resistive and capacitive currents using the phase shift addition method were proposed. The computer-based on-line monitoring device can sense accurately the power frequency leakage currents flowing through ZnO surge arresters. The on-line leakage current monitoring device of ZnO surge arresters proposed in this work has the high sensitivity compared to the third harmonic leakage current detection devices. As a consequence, it was found that the proposed leakage current monitoring device would be useful for forecasting the defects and degradation of ZnO surge arresters.