• Title/Summary/Keyword: IT Device

Search Result 12,082, Processing Time 0.046 seconds

A Study of Daesoon Jinrihoe's View of Time (I): Focusing on Time as Measured and Experienced (대순진리회의 시간관 연구 (I) - 측정되고 경험되는 시간을 중심으로 -)

  • Cha Seon-keun
    • Journal of the Daesoon Academy of Sciences
    • /
    • v.48
    • /
    • pp.1-40
    • /
    • 2024
  • Time can be the fundamental basis of religious doctrine and the foundation for a life of faith. Therefore, understanding a religion's interpretation of time and exploring its perception is accepted as one of the approaches to comprehending its principles. Based on this idea, this article delves into how chronos (measured time) and kairos (experienced time) are manifested in Daesoon Jinrihoe. In Daesoon Jinrihoe, the moment when chronos and kairos intersect is considered a moment of spiritual experience. Ethical codes are accomplished in the midst of the process of defining this time as the Heavenly Dao and adjusting human affairs accordingly. These ethics lead individuals towards a religious life. East Asian traditions also apply this logic, but Daesoon Jinrihoe differs in that it emphasizes reinterpreted ethics. Furthermore, Daesoon Jinrihoe posits that Degree Numbers (度數) are a device that ensures the transition from chronos to kairos. Degree Numbers, which are both a law of the universe's motion and a function of time, were emphasized by the Kang Jeungsan when he advocated for the discarding of old ways and the creation of the new ways. He thereby urged humans to live in accordance with time. Time is also facilitated in the dimension of ritual observances and participation, with examples including prayers, devotional offerings, and holy works (gongbu, 工夫). Those rituals of Daesoon Jinrihoe actively incorporate a unique basis of reason for this style of engagement with time, which is one of the aspects that is held to secure justification.

Optimization of 1.2 kV 4H-SiC MOSFETs with Vertical Variation Doping Structure (Vertical Variation Doping 구조를 도입한 1.2 kV 4H-SiC MOSFET 최적화)

  • Ye-Jin Kim;Seung-Hyun Park;Tae-Hee Lee;Ji-Soo Choi;Se-Rim Park;Geon-Hee Lee;Jong-Min Oh;Weon Ho Shin;Sang-Mo Koo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.332-336
    • /
    • 2024
  • High-energy bandgap material silicon carbide (SiC) is gaining attention as a next-generation power semiconductor material, and in particular, SiC-based MOSFETs are developed as representative power semiconductors to increase the breakdown voltage (BV) of conventional planar structures. However, as the size of SJ (Super Junction) MOSFET devices decreases and the depth of pillars increases, it becomes challenging to uniformly form the doping concentration of pillars. Therefore, a structure with different doping concentrations segmented within the pillar is being researched. Using Silvaco TCAD simulation, a SJ VVD (vertical variation doping profile) MOSFET with three different doping concentrations in the pillar was studied. Simulations were conducted for the width of the pillar and the doping concentration of N-epi, revealing that as the width of the pillar increases, the depletion region widens, leading to an increase in on-specific resistance (Ron,sp) and breakdown voltage (BV). Additionally, as the doping concentration of N-epi increases, the number of carriers increases, and the depletion region narrows, resulting in a decrease in Ron,sp and BV. The optimized SJ VVD MOSFET exhibits a very high figure of merit (BFOM) of 13,400 KW/cm2, indicating excellent performance characteristics and suggesting its potential as a next-generation highperformance power device suitable for practical applications.

Comparison of Muscle Strength between Dominant and Non-dominant Sides of College Students in Their 20s according to Contraction Type (수축 형태에 따른 20대 대학생의 우세 측과 비우세 측의 근력비교)

  • Jong-Hyup Lee;Seung-Kyu Lee;Young-Sun Na;Jeong-Woo Jeon;Jae-Ho Yu;Ji-Heon Hong;Jin-Seop Kim;Dong-Yeop Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.2
    • /
    • pp.47-53
    • /
    • 2024
  • Purpose : This study investigated the effects of concentric and eccentric contractions on muscle strength using an isokinetic dynamometer (ID) in college students in their 20s. It aimed to understand the impact of differences between the dominant and non-dominant sides on strength asymmetry and to elucidate the clinical implications of these differences to establish an appropriate posture and environment for patients. Methods : The experiment was conducted with 30 healthy adult participants. Prior to the experiment, participants underwent a warm-up targeting the shoulders, and efforts were made to eliminate factors that could potentially influence the measurement results. Subsequently, the maximum safe range of motion of shoulder joint abduction, extension, and flexion was measured using an isokinetic muscle function testing device. Muscle strength was assessed using concentric and eccentric contractions alternating between the dominant and non-dominant sides, and paired sample t-tests were used for the analysis. Results : There was no significant difference between bilateral peak torques for eccentric contraction in shoulder joint abduction, extension, and flexion (p>0.05). There was also no significant difference between bilateral peak torques for concentric contraction in shoulder joint abduction, extension and flexion (p>0.05). Conclusion : This study found no statistically significant difference in muscle strength between the dominant and non-dominant sides during concentric and eccentric contractions. However, previous studies have shown significant differences between the dominant and non-dominant sides during eccentric and concentric contractions during internal shoulder rotation in the general population, as well as significant differences in the upper trapezius muscle. Therefore, further research is needed to support the application of different intensities for bilateral muscle strengthening exercises in clinical practice.

Association between receiving work communications outside of work hours via telecommunication devices and work-related headaches and eyestrain: a cross-sectional analysis of the 6th Korean Working Conditions Survey

  • Yoon-Soo Jang;Jae-Han Lee;Na-Rae Lee;Dong-Woo Kim;June-Hee Lee;Kyung-Jae Lee
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.50.1-50.11
    • /
    • 2023
  • Background: The rise in telecommuting or non-face-to-face work owing to the coronavirus disease 2019 pandemic has fueled conversations regarding the "right to disconnect." Although evidence suggests that receiving work-related communications through telecommunication devices outside of work hours may lead to various symptoms and illnesses, limited research has been undertaken on these symptoms. This study therefore aims to investigate the correlation between receiving work communications through telecommunication devices after work hours and the occurrence of work-related headaches and eyestrain in full-time, non-shift white-collar workers. Methods: This study used data from the 6th Korean Working Conditions Survey. The frequency of using telecommunication devices for work purposes outside of working hours was divided into five categories: "Every day," "Several times a week," "Several times a month," "Rarely," and "Never." Work-related headaches and eyestrain were categorized based on a "yes" or "no" response to the survey questions. Descriptive statistics, χ2 tests, and multiple logistic regression analyses were performed using SPSS 27.0. Results: After adjusting for sex, age, income level, education, occupation, workplace size, work hours, and sleep disorders, the odds ratio (OR) of work-related headaches and eyestrain based on frequency of telecommunication device usage were as follows: "rarely" (OR: 1.292; 95% confidence interval [CI]: 1.111-1.503), "several times a month" (OR: 1.551; 95% CI: 1.249-1.926), "several times a week" (OR: 1.474; 95% CI: 1.217-1.784), and "every day" (OR: 1.548; 95% CI: 1.321-1.813). Conclusions: Employees who use telecommunication devices for work after regular hours are more susceptible to experiencing work-related headaches and eyestrain compared to those who do not. However, there is a dearth of research examining the physical and mental health impacts of using telecommunication devices for after-hours work. Furthermore, the existing preventative measures in Korea are insufficient. Consequently, it is imperative to develop effective measures and conduct additional research to address this issue.

A Study on X-ray Radiography for the Diagnosis of Screw Insertion Operation of Odontoid Fracture Patients in Cervical (목뼈 치아돌기 골절 환자의 나사못 삽입수술 진단을 위한 X-Ray 촬영법 연구)

  • Byung-Ju-Ahn;In-Soo Kim;Jong-Nam Song;Jae-Bok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.309-315
    • /
    • 2024
  • The Study In order to obtain a Clear Image of fractures in Atlas and Axis of Cervical Spin, this Study obtained Images examined using a Cervical Spin Pantom and a Radiation device, and then Commissioned five Radiologists and three Orthopedic Regent Doctors for Subjective Psychological ROC (Receiver, Operation, Characteristic) Evaluation. As aRresult, the X-ray Tube was Tilted 15° toward the leg to Receive a high score of 29 Points during the Eamination, and the Objective Evaluation Signal-to-noise Ratio (SNR) was 6.032 points, which was high. In Addition, by Tilting the X-ray tube 10° toward the head, it received a high score of 33 points during the Examination, and a high score of 7.840 Points in the objective evaluation. And as a result of Subjectively and Objectively Statistically Evaluating the Examined Images, the Cronbach Alpha value was Calculated as 0.791. Since the Cronbach Alpha value was 0.7 or higher, the Reliability could be Evaluated as 'very good', and the significance probability (p) was Statistically Significant at 0.042 points.

Evaluation of Albumin Creatinine Ratio as an Early Urinary Biomarker for Chronic Kidney Disease in Dogs

  • Hyun-Min Kang;Heyong-Seok Kim;Min-Hee Kang;Jong-Won Kim;Dong-Jae Kang;Woong-Bin Ro;Doo-Won Song;Ga-Won Lee;Hee-Myung Park;Hwi-Yool Kim
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.399-407
    • /
    • 2023
  • Chronic kidney disease (CKD) occurs in more than 15% of the dogs over 10 years of age and causes irreversible renal function deterioration. Therefore, it is important to diagnose CKD early and treat the disease properly. The purpose of this study aimed to to evaluate the clinical utility of urine albumin/creatinine ratio (ACR) using POC (point-of-care) device as an early detection urinary biomarker in CKD dogs and to confirm the correlation between ACR and other known CKD biomarkers. Urine and serum samples were obtained from 50 healthy dogs and 50 dogs with CKD. Serum blood urea nitrogen (BUN), creatinine, and symmetric dimethylarginine (SDMA) concentrations, and urine protein creatinine ratio (UPC) were measured. Urine specific gravity (USG) was evaluated using refractometer, and ACR was measured using an i-SENS A1Care analyzer. The ACR values of dogs with CKD were significantly different from those of healthy dogs (p < 0.001), as with other renal biomarkers. ACR showed significant differences between healthy dogs and dogs with CKD at every IRIS stage (p < 0.005), whereas no significant differences were observed between dogs with CKD IRIS stage I and healthy dogs with UPC. There are significant positive correlation between ACR and BUN (r = 0.611, p < 0.001), creatinine (r = 0.788, p < 0.001), SDMA (r = 0.747, p < 0.001), and UPC (r = 0.784, p < 0.001), and significant negative correlation between ACR and USG (r = -0.700, p < 0.001). In receiver operator characteristic curve analysis, the area under the curve (AUC) was 0.982 (95% CI 0.963-1.000, p < 0.001), with an optimal cut-off value of 64.20 mg/g (94% sensitivity and 94% specificity). Thus, ACR is a useful urinary biomarker for the early diagnosis of proteinuria in CKD and combined use of ACR and other renal biomarkers may be helpful for early diagnosis and prevention of CKD in dogs.

Analytical Evaluation of PPG Blood Glucose Monitoring System - researcher clinical trial (PPG 혈당 모니터링 시스템의 분석적 평가 - 연구자 임상)

  • Cheol-Gu Park;Sang-Ki Choi;Seong-Geun Jo;Kwon-Min Kim
    • Journal of Digital Convergence
    • /
    • v.21 no.3
    • /
    • pp.33-39
    • /
    • 2023
  • This study is a performance evaluation of a blood sugar monitoring system that combines a PPG sensor, which is an evaluation device for blood glucose monitoring, and a DNN algorithm when monitoring capillary blood glucose. The study is a researcher-led clinical trial conducted on participants from September 2023 to November 2023. PPG-BGMS compared predicted blood sugar levels for evaluation using 1-minute heart rate and heart rate variability information and the DNN prediction algorithm with capillary blood glucose levels measured with a blood glucose meter of the standard personal blood sugar management system. Of the 100 participants, 50 had type 2 diabetes (T2DM), and the average age was 67 years (range, 28 to 89 years). It was found that 100% of the predicted blood sugar level of PPG-BGMS was distributed in the A+B area of the Clarke error grid and Parker(Consensus) error grid. The MARD value of PPG-BGMS predicted blood glucose is 5.3 ± 4.0%. Consequentially, the non-blood-based PPG-BGMS was found to be non-inferior to the instantaneous blood sugar level of the clinical standard blood-based personal blood glucose measurement system.

Relationship Between Amyloid Positivity and Sleep Characteristics in the Elderly With Subjective Cognitive Decline

  • Kyung Joon Jo;SeongHee Ho;Yun Jeong Hong;Jee Hyang Jeong;SangYun Kim;Min Jeong Wang;Seong Hye Choi;SeungHyun Han;Dong Won Yang;Kee Hyung Park
    • Dementia and Neurocognitive Disorders
    • /
    • v.23 no.1
    • /
    • pp.22-29
    • /
    • 2024
  • Background and Purpose: Alzheimer's disease (AD) is a neurodegenerative disease characterized by a progressive decline in cognition and performance of daily activities. Recent studies have attempted to establish the relationship between AD and sleep. It is believed that patients with AD pathology show altered sleep characteristics years before clinical symptoms appear. This study evaluated the differences in sleep characteristics between cognitively asymptomatic patients with and without some amyloid burden. Methods: Sleep characteristics of 76 subjects aged 60 years or older who were diagnosed with subjective cognitive decline (SCD) but not mild cognitive impairment (MCI) or AD were measured using Fitbit® Alta HR, a wristwatch-shaped wearable device. Amyloid deposition was evaluated using brain amyloid plaque load (BAPL) and global standardized uptake value ratio (SUVR) from fluorine-18 florbetaben positron emission tomography. Each component of measured sleep characteristics was analyzed for statistically significant differences between the amyloid-positive group and the amyloid-negative group. Results: Of the 76 subjects included in this study, 49 (64.5%) were female. The average age of the subjects was 70.72±6.09 years when the study started. 15 subjects were classified as amyloid-positive based on BAPL. The average global SUVR was 1.598±0.263 in the amyloid-positive group and 1.187±0.100 in the amyloid-negative group. Time spent in slow-wave sleep (SWS) was significantly lower in the amyloid-positive group (39.4±13.1 minutes) than in the amyloid-negative group (49.5±13.1 minutes) (p=0.009). Conclusions: This study showed that SWS is different between the elderly SCD population with and without amyloid positivity. How SWS affects AD pathology requires further research.

In-Situ Gamma Spectrometry Research Analysis and Radiation Efficiency Sensitivity Evaluation (감마핵종 In-Situ 측정 연구 동향 분석 및 방사능 측정 효율 민감도 평가)

  • Hyun Jun Na;Hyeok Jae Kim;Seong Yeon Lee;Min Woo Kwak;Kwang Pyo Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Since a large amount of radioactive waste is expected to be generated due to permanent shutdown of many nuclear power plants, it is necessary to prepare efficient management methods for radioactive waste. Therefore, there is a need for a based study to apply the In-Situ gamma spectrometry, which can simplify the measurement procedure. The purpose of this study is to analyze research cases of In-Situ gamma spectrometry and to analyze the sensitivity of measurement according to influencing factors on In-Situ gamma spectrometry. Research cases of five institutions, including the CERN and the Imperial College Reactor Centre (ICRC), were selected as the institutions to be investigated. Research on the In-Situ gamma spectrometry was conducted on the satisfaction of the acceptance criteria for radioactive waste and the analysis of residual radioactivity in the site. In-Situ Objective Counting System (ISOCS) was used as a major measuring device. Sampling and computer code were used to verify the analysis results. For evaluation of measuring sensitivity according to influencing factors on In-Situ gamma spectrometry, the thickness of the measurement target, the distance between the detector and the target, the angle of the collimator, and the contamination location were performed using ISOCS's Geometry Composer. In every case, based on 122 keV, the efficiency decreased as the energy increased in the high energy region, and the efficiency decreased as the energy decreased in the low energy region. As the target thickness increased, the efficiency decreased, and as the distance between target and detector increased, the efficiency decreased. As the distance between contamination and detector increased, the efficiency decreased, and as the angle of the collimator increased, the measurement efficiency increased. However, when simulating the measurement situation using Geometry Composer, the background is not considered, and the probability of incident in the background increases as the angle increases, so further research needs to be conducted in consideration of these. This study can be utilized when applying the In-Situ gamma spectrometry of radioactive waste clearance in the future.

Analysis of the application of image quality assessment method for mobile tunnel scanning system (이동식 터널 스캐닝 시스템의 이미지 품질 평가 기법의 적용성 분석)

  • Chulhee Lee;Dongku Kim;Donggyou Kim
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.4
    • /
    • pp.365-384
    • /
    • 2024
  • The development of scanning technology is accelerating for safer and more efficient automated inspection than human-based inspection. Research on automatically detecting facility damage from images collected using computer vision technology is also increasing. The pixel size, quality, and quantity of an image can affect the performance of deep learning or image processing for automatic damage detection. This study is a basic to acquire high-quality raw image data and camera performance of a mobile tunnel scanning system for automatic detection of damage based on deep learning, and proposes a method to quantitatively evaluate image quality. A test chart was attached to a panel device capable of simulating a moving speed of 40 km/h, and an indoor test was performed using the international standard ISO 12233 method. Existing image quality evaluation methods were applied to evaluate the quality of images obtained in indoor experiments. It was determined that the shutter speed of the camera is closely related to the motion blur that occurs in the image. Modulation transfer function (MTF), one of the image quality evaluation method, can objectively evaluate image quality and was judged to be consistent with visual observation.