• Title/Summary/Keyword: IT

Search Result 397,343, Processing Time 0.312 seconds

The Comparison of Quantitative Indices by Changing an Angle of LAO View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Ryu, Jae-Kwang;Kim, Seong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose: The multi-gated cardiac blood pool scan is to evaluate the function of left ventricle (LV) and usefully observe a value of ejection fraction (EF) for a patient who is receiving chemotherapy. To calculate LVEF, we should adjust an angle of left anterior oblique (LAO) view to separate both ventricles. And by overlapped ventricles, it is possible to affect LVEF. The purpose of this study is to investigate and compare quantitative indices by changing an angle of LAO view. Materials and methods: We analyzed the 49 patients who were examined by multi-gated cardiac blood pool scan in department of nuclear medicine at Asan Medical Center from June to September 2011. Firstly, we acquired "Best septal" view. And then, we got images by addition and subtraction of angle for LAO view to anterior and lateral. We compared three LAO views for 20 people by 5 degrees and 39 people by 10 degrees. And we analyzed quantitative indices, EF, end diastole and end systole counts, by automated and manual region of interest (ROI) modes. Results: Firstly, we analyzed quantitative indices by automated ROI mode. In case of 5 degrees, the averages of EF are $61.0{\pm}7.5$, $62.1{\pm}7.1$, $60.9{\pm}6.7%$ ($p$=0.841) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $62.4{\pm}9.5$, $62.3{\pm}10.8$, $61.6{\pm}.9.3%$ ($p$=0.938) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Secondly, we analyzed quantitative indices by manual ROI mode. In case of 5 degrees, the averages of EF are $62.8{\pm}7.1$, $63.6{\pm}7.5$, $62.7{\pm}7.3%$ ($p$=0.903) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $65.5{\pm}9.0$, $66.3{\pm}8.7$, $63.5{\pm}.9.3%$ (p=0.473) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Conclusion: When an image is nearly "Best septal" view, the difference of LAO angle would not affect to change LVEF. Although there was no difference in quantitative analysis, deviations could happen when to interpret wall motion qualitatively by reading physicians.

  • PDF

A Study on the Extraction Rate of Brain Tissues from a $^{99m}Tc$-HMPAO Cerebral Blood flow SPECT Examination of a Patient ($^{99m}Tc$-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰)

  • Kim, Hwa-San;Lee, Dong-Ho;Ahn, Byeong-Pil;Kim, Hyun-Ki;Jung, Jin-Yung;Lee, Hyung-Nam;Kim, Jung-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2012
  • Purpose: This study mainly focuses on the patients treated with chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO (d,l-hexamethylpropylene amine oxime) which yielded reduced image quality due to a decreased brain extraction rate. $^{99m}Tc$-HMPAO will be examined further to determine whether this product may be accounted as a factor for this cause. Material and Methods: From January 2010 until December 2010, out of 272 patients who were all subjected to $^{99m}Tc$-HMPAO brain blood flow SPECT scans resulting from Cerebral Infarction; 23 patients(ages $55.3{\pm}9$, 21 males, 3 females) with decreased tissue extraction rate were examined in detail. The radiopharmaceutical product $^{99m}Tc$-HMPAO was used on patients with normal brain tissue exchange rate as well as those with reduced rate in order to prove its' chemical stability. The patients' age, sex, blood pressure, existence of diabetes, drug use, current health status, known side effects from CT/MRI, examination of the patients' past SPECT before/after images were accounted to determine the factors and correlations affecting the rate of blood tissue extractions. Result: After multiple linear regression analysis, there were no unusual correlations between the 6 factors excluding sex, and before/after examination images. Male subjects showed reduced brain tissue extraction rate than the females ($p$ > 0.05) 91.3% male, 8.7% female. Wilcoxon Matched-Pairs Signed-Ranks Test was used on the before/after images which yielded a value of 0.06, which did not indicate a significant amount of difference on the 2 tests ($p$ > 0.05). As a result, the before/after images indicated similar brain tissue extraction rates, and there were variations depending on the individual patient. Conclusion: The effects of the chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO depended on the patient's personal characteristics and status, therefore was considered to be a factor in reducing brain tissue extraction rate. The related articles of $^{99m}Tc$-HMPAO cerebral blood flow SPECT speculates a cerebrovascular disease and factors resulting from portal veins, and it was not possible to pin point the exact cause of decreasing brain tissue extraction rate. However, the $^{99m}Tc$-HMPAO cerebral blood flow SPECT scan proved to be extremely useful in tracking and inspecting brain diseases, as well as offering accurate results from patients suffering from reduced brain tissue extraction rates.

  • PDF

Application of Westgard Multi-Rules for Improving Nuclear Medicine Blood Test Quality Control (핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용)

  • Jung, Heung-Soo;Bae, Jin-Soo;Shin, Yong-Hwan;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.115-118
    • /
    • 2012
  • Purpose: The Levey-Jennings chart controlled measurement values that deviated from the tolerance value (mean ${\pm}2SD$ or ${\pm}3SD$). On the other hand, the upgraded Westgard Multi-Rules are actively recommended as a more efficient, specialized form of hospital certification in relation to Internal Quality Control. To apply Westgard Multi-Rules in quality control, credible quality control substance and target value are required. However, as physical examinations commonly use quality control substances provided within the test kit, there are many difficulties presented in the calculation of target value in relation to frequent changes in concentration value and insufficient credibility of quality control substance. This study attempts to improve the professionalism and credibility of quality control by applying Westgard Multi-Rules and calculating credible target value by using a commercialized quality control substance. Materials and Methods : This study used Immunoassay Plus Control Level 1, 2, 3 of Company B as the quality control substance of Total T3, which is the thyroid test implemented at the relevant hospital. Target value was established as the mean value of 295 cases collected for 1 month, excluding values that deviated from ${\pm}2SD$. The hospital quality control calculation program was used to enter target value. 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T of Westgard Multi-Rules were applied in the Total T3 experiment, which was conducted 194 times for 20 days in August. Based on the applied rules, this study classified data into random error and systemic error for analysis. Results: Quality control substances 1, 2, and 3 were each established as 84.2 ng/$dl$, 156.7 ng/$dl$, 242.4 ng/$dl$ for target values of Total T3, with the standard deviation established as 11.22 ng/$dl$, 14.52 ng/$dl$, 14.52 ng/$dl$ respectively. According to error type analysis achieved after applying Westgard Multi-Rules based on established target values, the following results were obtained for Random error, 12s was analyzed 48 times, 13s was analyzed 13 times, R4s was analyzed 6 times, for Systemic error, 22s was analyzed 10 times, 41s was analyzed 11 times, 2 of 32s was analyzed 17 times, $10\bar{x}$ was analyzed 10 times, and 7T was not applied. For uncontrollable Random error types, the entire experimental process was rechecked and greater emphasis was placed on re-testing. For controllable Systemic error types, this study searched the cause of error, recorded the relevant cause in the action form and reported the information to the Internal Quality Control committee if necessary. Conclusions : This study applied Westgard Multi-Rules by using commercialized substance as quality control substance and establishing target values. In result, precise analysis of Random error and Systemic error was achieved through the analysis of 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T rules. Furthermore, ideal quality control was achieved through analysis conducted on all data presented within the range of ${\pm}3SD$. In this regard, it can be said that the quality control method formed based on the systematic application of Westgard Multi-Rules is more effective than the Levey-Jennings chart and can maximize error detection.

  • PDF

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

  • PDF

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

A Clinical Study of Acute Poststreptococcal Glomerulonephritis with Nephrotic Syndrome (신증후군을 동반한 연쇄상구균 감염후 급성사구체신염의 임상적 고찰)

  • Moon Sang-Ae;Yook Jin-Won;Kim Ji-Hong;Lee Jae-Seung;Jeong Hyun-Joo;Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.123-129
    • /
    • 1999
  • Purpose: Acute poststreptococcal glomerulonephritis(APSGN) is a renal disease which is characterized by glomerular proliferation and inflammatory changes due to immune reaction. Although the 95% of patients with APSGN seems to recover fully and present as benign course, the remaining patients show poor prognosis. Therefore comparative retrograde study between APSGN with and without nephrotic syndrome was done to find out the any prognostic indicator to predict the outcome in patients with APSGN. Methods: We had retrospectively analyzed seventy-one patients who were diagnosed as APSGN clinically from Mar.1989 to Feb.1999 in Yonsei university medical center. Sixty-four of the patients was APSGN without nephrotic syndrome(Group A) and seven patients were in APSGN with nephrotic syndrome(Group B). Results: Patients who were diagnosed as APSGN with nephrotic syndrome were seven(9.9%) out of seventy-one. In the comparative study, sex ratio was 1:1 in group A and 1.9: 1 in group B, onset mean age was $8.9{\pm}2.6$ in group A and $8.8{\pm}2.6$ in group B. Following clinical profiles were compared but there were no significant difference between these two groups: WBC count($9413{\pm}2964\;vs\;9368{\pm}2650(/mm^3)$), hemoglobin($10.6{\pm}1.2\;vs\;10.0{\pm}0.9(gm/dL)$), ASO($746.1{\pm}640.7\;vs\;614.9{\pm}475.9(IU/ml)$), $C_3(20.1{\pm}17.0\;vs\;16.9{\pm}13.1(mg/dL)$), $C_4(22.8{\pm}9.5\;vs\;22.6{\pm}6.9(mg/dL)$), BUN($25.8{\pm}26.1\;vs\;28.1{\pm}14.5(mg/dL)$), creatinin($0.8{\pm}0.3\;vs\;0.8{\pm}0.3(mg/dL)$), $C_{cr}(80.6{\pm}28.8{\pm}62.4{\pm}31.4(ml/min/1.73\;m^2$)), the duration of edma, gross hematuria, and hypertension. However, we found that there were a significant difference in the duration of proteinuria($1.95{\pm}2.27\;vs\;13.3{\pm}21.1(months)$)(P<0.05), decreased $C_3$ duration($1.9{\pm}2.9\;vs\;7.3{\pm}5.0(weeks)$)(P<0.05) and especially it was proloned according to the amount of early urine protein excretion. Conclusion: Our study showed markedly prolonged duration of proteinuria and decreased $C_3$ duration in patients with APSGN with nephrotic syndrome. We were not able to find the definite prognostic factor that will guide the outcome of patients with APSGN accompaning nephrotic syndrome, but above findings seemed to represent as a relative indication of the outcome of the disease. All patients recovered completely and we did not experience any cases that progressed into the renal failure.

  • PDF

Asymptomatic Primary Hematuria in Children (소아의 무증상성 일차성 혈뇨에 관한 고찰)

  • Lee, Jung-Mi;Park, Woo-Saeng;Ko, Cheol-Woo;Koo, Ja-Hoon;Kwak, Jung-Sik
    • Childhood Kidney Diseases
    • /
    • v.4 no.1
    • /
    • pp.25-32
    • /
    • 2000
  • Purpose: This retrospective study of 126 children with symptomless primary hematuria was undertaken to determine the distribution of various histologic types by renal biopsy, clinical outcome according to the biopsy findings and also to find out feasibility of performing renal biopsy in these children. Patients and Methods : Study population consisted of 126 children with symptom-less primary hematuria who have been admitted to the pediatric department of Kyung-poot National University Hospital for the past 11 years from 1987 to 1998 and renal biopsy was performed percutaneously. Hematuric children with duration of less than 6 months, evidences of systemic illness such as SLE or Henoch-Schonlein purpura, urinary tract infection, and idiopathic hypercalciuria were excluded from the study. Results : Mean age of presentation was 9.2${\pm}$3.3 years (range ; 1.5-15.3 years) and male preponderance was noted with male to female ratio of 2:1. IgA nephropathy was the most common biopsy finding occuring in 60 children ($47.6\%$), followed by MsPGN in 13 ($10.3\%$), MPGN in 5 ($3.9\%$), TGBM in 6 ($4.7\%$), Alport syndrome in 2 ($1.6\%$), FSGS in 1 ($0.8\%$), and in 39 children ($30.9\%$), 'normal' glomeruli were noted. Recurrent gross hematuria was more common than persistent microscopic hematuria (84 versus 42), and especially in IgA nephropathy, recurrent gross hematuria was the most prevalent pattern of hematuria. In 58 out of 126 cases ($46.0\%$), hematuria was isolated without accompa-nying proteinuria and this was especially true In cases of MsPGN and 'normal' glomer-uli by biopsy finding. Normalization of urinalysis (disappearance of hematuria) in IgA nephropathy, MsPGN and 'normal' glomuli group were similar and it was $14\%,\;27\%\;and\;21\%$ respectively during 1-2 years of follow-up period, and $37.1\%,\;40\%\;and\;35\%$ respectively during 3-4 years of follow-up periods. However, abnormal urinalysis persi-sted in the majority of children with MPGN, TGBM. Alport syndrome and FSGS. Renal function deteriorated progressively in 6 cases (3 with IgA nephropathy, 2 with Alport syndrome and 1 with TGBM). Conclusion : In summary, present study demonstrates that in 126 children with symptomless primary hematuria, IgA nephropathy was the most common biopsy findings followed by MsPGN, MPGN, TGBM, Alport syndrome and FSGS, and 'normal glomeruli' was also seen in 39 cases ($30.9\%$). Renal histology could not be predictable on the clinical findings, so that to establish appropriate long-term planning for these children, we would recommend to obtain precise histologic diagnosis by renal biopsy.

  • PDF

A Clinical and Pathological Analysis of Children with Membranoproliferative Glomerulonephritis According to the Clinical Manifestations at Presentation (발견 양상에 따른 소아 막증식성 사구체신염의 임상적 및 병리조직학적분석)

  • Jeon Chang-Ho;Kang Mi-Seon;Chung Woo-Yeong
    • Childhood Kidney Diseases
    • /
    • v.8 no.2
    • /
    • pp.186-194
    • /
    • 2004
  • Purpose: Membranoproliferative glomeulonephritis(MPGN) has been diagnosed in an increasing number of asymptomatic cases. These cases have been detected by school urinary screening test even though the total cases of MPGN show a decreasing trend. We have analyzed the clinical and pathological characteristics of children with MPGN according to the clinical manifestations at the time of disease presentation. Methods: A total of 18 patients who had been diagnosed with idiopathic MPGN by percutaneous renal biopsy from January 1990 to February 2004 were involved in our study. The patients were divided into 2 groups as the school urinary screening(A) group and the symptomatic(S) group according to the clinical manifestations at the time of disease presentation. Results: Out of the total 18 patients, 8(44.4%) were in the S group and 10(55.6%) were in the A group. The mean serum total protein, albumin and $C_3$ levels in the S group were significantly lower than those levels of the A group, respectively($4.9{\pm}1.2\;g/dL,\;vs\;7.0{\pm}0.5\;g/dL\;P=0.002,\;2.8{\pm}0.9\;g/dL\;vs.\;4.1{\pm}0.3\;g/dL\;P=0.002,\;63.9{\pm}36.4\;mg/dL\;vs.\;100.8{\pm}39.5\;g/dL\;P=0.041$). The mean total protein amount of 24 hour collected urine in the S group were significantly higher than that of the A group($3684.0{\pm}2601.3\;mg/m^2\;vs.\;559.4{\pm}4.6.9\;mg/m^2$, respectively, P=0.001). Hypocomplementemia was observed in 11(61.1%) out of 18 patients at the time of disease onset, 7(87.5%) in the S group and 4(40%) in the A group. However the hypocomplementemia was decreased in 6(33.3%) out of 18 patients at the time of final follow-up, 3(37.5%) in the S group and 3(30%) in the A group. According to the pathologic type, hypocomplementemia was observed 8 patients(61.5%) with type I disease, 1 patients (100%) with type II disease, 2 patients(50%) in type III disease at the disease onset, but 4 patients(30.8%) in type I disease, 1 patient(100%) in type II disease, 1 patient(33.3%) with type III disease at the time of last follow-up. The incidence of cellular crescent formation and tubular atropy. as observed on light microscopy, were higher in the S group compared to the A group. Mean grade of capillary wall thickening and, mesangial proliferation were significantly higher in the S group. Conclusion: MPGN, as diagnosed in patients with only asymptomatic urinary abnormalities, has been increasing, it is more frequent in asymptomatic patients than in patients with presenting symptoms. Our result suggests that MPGN should be considered in the renal biopsy diagnosis regardless of serum $C_3$ level when urinary abnormalities are found by school urinary screening test.

  • PDF

Dietary Effects of an Animal Fat with High Free- Fatty Acid Content on Feed Utilization and Meat Quality in Broilers (고산가 동물성 지방의 첨가가 육계의 사료이용성과 육질에 미치는 영향)

  • 오미향;지규만;최인숙
    • Korean Journal of Poultry Science
    • /
    • v.12 no.1
    • /
    • pp.7-16
    • /
    • 1985
  • Present experiment was undertaken to compare the effects of two dietary fats whose free fatty acid content was quite different on performances and on meat quality of broilers. Yellow grease or animal fat (trade name) containing 15 or 38.6% free fatty acid, respectively, was added to the broiler starter and finisher diets at levels of 3.0 and 5,0%, respectively. A total of 108, day old, male Maniker(Chunho) broiler chicks was alloted to 3 dietary treatments with 3 replications per treatment and 12 chicks per replication Though control diet was not supplemented with fat, the three dietary groups were made isocaloric and isonitrogenous. All the chicks were ad libitum fed the test diets for 8 weeks. Feed intake and body weight were measured every other week. Shank color was measured at the end of feeding trial by Roche Color Fan. To evaluate meat quality, 7 chicks of mean body weight were selected from each treatment group after the trial. Measurements were made for abdominal fat content, organoleptic scores for thigh and breast, and for contents of total lipids, free fatty acids, iodine values and peroxide values of the breasts. During the period from 0 to 4 weeks of age, the broilers fed the diets added with fats performed the same as those fed the control diet. However, the body weight gam (25%), feed intake (10.8%) and feed efficiency (11.3%) of chicks fed the fat-supplemented diets, during the finisher period (5-8 weeks), appeared significantly improved compared to those of control group (p<0.05). During overall period of 8 weeks, body weight gain, feed intake, and feed efficiency of chicks fed the diets added with fats were, on the average, 16.2. 8.8 and 6.8%, respectively, better than, those of control Monwhile the performance between the chicks fed diets added with the two different fat sources appeared to be of the same tendency. Though the shank pigmentation was not statistically different among the treatments, the chicks fed the fat-supple ented diets tended to have slightly less pigments than the control. Organoleptic scores of thigh or breast of chicks fed the animal fat diet were of the same range as those of the other two groups. The contents of total lipids, free fatty acids, iodine values and peroxide values of breasts from broilers fed the various diets appeared to be in the same ranges among the treatments. The values for control, yellow grease and animal fat groups were 7.77, 6.66 and 6.32% for total lipids, 9.23, 9.7 and 9.31mg oleic acid/g fat for free fatty acids, 65.36, 63.89 and 59.25g/ 100g fat for iodine values, and 9.62, 10.46 and 8.79 meq/kg fat for peroxide values, respect vely. Changes of free fatty acids contents of breast during a storage for 10 da s at 4$^{\circ}C$ were also not different among the dietary groups. From the observations n. this experiment, it seems possible to conclude that the animal fat containing 38.6% free fatty acid can be used as efficiently as yellow grease in broiler diets without any adverse effects on meat quality.

  • PDF