• 제목/요약/키워드: IT건축

검색결과 9,516건 처리시간 0.031초

조선대학교 본관과 건축가 김한섭의 상관성에 관한 고찰: 1940~50년대를 중심으로 (A study of correlation between Architect, Kim Han-sup's Architecture and the main building of Chosun University in the 1940's to 1950's)

  • 김명선;김용춘
    • 건축역사연구
    • /
    • 제27권6호
    • /
    • pp.41-48
    • /
    • 2018
  • For the proper preservation and utilisation of Regional Modern Heritage Buildings, it is necessary to study the history of local modern architecture based on a broad understanding of the region and also to architectural history. The aim of this study is expand the awareness and multi-faceted interpretation of modern architecture in Kwangju in the 1940's to 1950's, by exploring the origin of regional modern architecture from new perspectives. As a part of the discussions of the perspectives, this study will be therefore explained with the regional correlations between the architect Kim Han-seop's works and activity, influential politicians, strong enthusiasm of education, architectural characteristics of the main building of Chosun University, architecture schools and association in Kwangju. Then, it will be finalised that Kim Han-seop and the main building of Chosun University are directly and indirectly correlated and affected each other strongly.

건축자산 진흥구역에서 결합건축 제도의 시행이 도시 형태에 미칠 영향에 관한 연구 (A Study on the Urban Morphological Implications by Implementation of the Conjoint Building Program within Architectural Heritage Promotion Districts)

  • 김도현;최춘웅
    • 대한건축학회논문집:계획계
    • /
    • 제34권2호
    • /
    • pp.107-118
    • /
    • 2018
  • A primary objective the Conjoint Building Program(CBP), as articulated in the legislation proceedings as to stimulate renewal and regeneration of old deteriorated districts. By allowing the transfer of development rights between two lots located within 100m radius or the same block surrounded by 12m wide streets, CBP encourages reconstruction of old buildings with low investment value by linking it to another lot that can buy its unused floor area ration. Most of the debates and studies prior to the introduction of the new legislation focused on possible abuse in financial terms, and little research has been done to illustrate possible merits of deficiencies in term of urban morphological influences. This study offers a visual prediction of the various ways CBP can influence an urban block by reshaping and reorganizing it thrown augmented development rights to assess the pros and cons of the current program.

생체모방의 건축적 적용을 위한 프로세스 (Process for the Architectural Application of Biomimicry)

  • 김종무;강철희;윤혜경
    • 대한건축학회논문집:계획계
    • /
    • 제34권12호
    • /
    • pp.77-84
    • /
    • 2018
  • Biomimicry architecture has been highlighted in recent years for the innovative ideas from the nature have provided main developments in many areas. The related studies in Korean architecture is entering the first step and are needed close attentions for its vitalizations. This study starts with the acknowledgement of necessity to establish the architectural application process. First of all, it is named as a 'Passive Cycle' if a problem-solving or a project has been through the analysis of process complexity and biomimicry application process in other areas. Then, the basic frame is structured as a 'Process-Cooperation,' which integrates process complexation with process circulation. The cooperative relationship starts from the beginning of the design with not only professionalists related with architecture but also ones in various areas when it is issued a difficult problem or high environmental performance not found in common architectural design processes. To make the architectural application good progress, the characteristics of bio-mimetic architectural applications are categorized as three areas; the expected effect, the application level, and application method. As a result, the organic complexity should be prioritized to have bio-mimetic application effectively while accessing the principles. Therefore, the process for the architectural application of biomimicry is suggested as 'Organic Cycle-Cooperation.'

D형 Durometer를 이용한 콘크리트의 미장용 모르타르의 응결시간 및 초기재령 압축강도 추정 (ing Durometer D type Evaluation of the possibility of Estimatingon of Setting Time and InitialEarly aAge Compressive Strength Using Durometer D type Durometer)

  • 한수환;한준희;현승용;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.57-58
    • /
    • 2021
  • This study is conducted an experiment to unifyprovide a method to estimate the method of measuring the condensationsetting time and estimating the initialearly age compressive strength using the existingD type ddurometer. into a single device and to adopt the best estimation guidelines of the estimator. As a result of the experiment, Test results indicated that it is analyzed that the use of D type Durometer attached with modified needle, which was designed to secure improved accuracy in setting and compressive strength, enables to estimate it is possible to estimate the condensationsetting time of mortar and estimate the compressive strength ofat early age. the initial age when the estimation No. 2 is adopted for the Durometer D type.

  • PDF

이미지 기반 건설현장 수치 측정 모델 기초연구 (Preliminary Study for Image-Based Measurement Model in a Construction Site)

  • 윤세빈;강민균;김창원;임현수;유위성;김태훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.287-288
    • /
    • 2023
  • The inspection work at construction sites is one of the important supervisory tasks, which involves verifying that the building is being constructed by the numerical values specified in the design drawings. The conventional measuring method for inspection involves using tools or equipment such as rulers directly by the personnel at the site, and it is usually confirmed by vision. Therefore, this study proposes an model to measure numerical values on images of the construction site. Through the case study to measure the installation interval of jack supports, the proposed algorithm was verified the effiect and validity. The results of this study suggest that it can support inspection work even in the office, which may have been overlooked by on-site inspectors, and contribute to the digitization of inspection work at construction sites.

  • PDF

광발열 단열시트를 적용한콘크리트의 특성 (Performance of Heat Insulation Capability of the Concrete Applying Light Heat Generating Sheet)

  • 이현직;백성진;이승민;임군수;김종;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.169-170
    • /
    • 2023
  • In this study, light-heat generating materials were produced in two ways, and the performance of two light-generating insulation sheets was reviewed. As a result of the experiment, it was possible to confirm the improved heating performance of the light heating insulation sheet compared to the existing bubble sheet. The light heat insulation sheet (b) showed improved thermal properties compared to the existing bubble sheet, and it is believed that the temperature has increased due to the combined effect of initial hydration heat and heat generation after installation. In future studies additional experiments are needed to compensate for the insufficient insulation performance due to the single bubble sheet through the double bubble sheet and to adjust the amount of light-generating materials added as a consideration of the optimal heat-generating effect of the light-generating insulation sheet (b).

  • PDF

객체 탐지 딥러닝 기법을 활용한 필지별 조사 방안 연구 (Detecting high-resolution usage status of individual parcel of land using object detecting deep learning technique )

  • 전정배
    • 지적과 국토정보
    • /
    • 제54권1호
    • /
    • pp.19-32
    • /
    • 2024
  • 본 연구에서는 드론영상을 기반으로 YOLO 알고리즘을 통해 시설물과 농경지를 대상으로 객체탐지를 실시하고, 이를 법정지목과 비교를 수행하여 영상기반의 조사 가능성을 검토하였다. YOLO 알고리즘을 통해 객체를 탐지한 결과 건축물의 경우에는 기존 수치지형도에서 제공하고 있는 건축물 중 96.3%에 해당하는 객체를 탐지하는 것으로 분석되었다. 또한 수치지형도에서는 건축물이 위치하지 않지만, 영상에서 건축물이 존재하는 136개의 건축물을 추가로 탐지하는 것으로 나타나 정확도가 높은 것으로 나타났다. 비닐하우스의 경우에는 총 297개를 탐지했으나, 일부 과수형 비닐하우스의 경우에 탐지율이 낮은 것으로 분석되었다. 마지막으로 농경지는 가장 낮은 탐지율을 보였다. 농경지는 시설물 대비 넓은 면적과 불규칙한 형상으로 학습데이터의 일관성이 낮아 정확도가 시설물에 비해 작은 것으로 판단된다. 따라서 농경지의 경우에는 박스형태의 탐지가 아닌 Segmentation 탐지가 더욱 효과적으로 활용될 것으로 보인다. 마지막으로 탐지된 객체를 법정지목과 비교를 수행하였다. 그 결과 건축물이 입지가 어려운 농경지 및 임야에서 건축물이 존재하는 것으로 분석되었다. 그러나 이 건축물이 불법으로 활용됨을 파악하기 위해선 행정정보와 연계가 필요할 것으로 보여진다. 따라서 현재 수준에서는 건축물이 입지하기 어려운 필지에 건축물의 존재유무를 객관적으로 판단할 수 있는 수준까지 조사가 가능한 것으로 볼 수 있다.

르 꼬르뷔제 건축에 나타난 빛의 건축적 표현에 관한 연구 (A Study on the Architectural Expression of the light Appeared in the Works of Le Corbusier)

  • 김창성
    • KIEAE Journal
    • /
    • 제12권4호
    • /
    • pp.71-76
    • /
    • 2012
  • The light is one of the most important factors in architectural design. Especially, natural light is the valuable source of illumination that can be utilized for better indoor environment. Compared to artificial light, it is a sustainable energy source without the cost of electric energy and offers a more natural feeling to residents stayed in buildings. Natural light also creates light and shadow in building. It enables people to perceive the depth of space. Many architects have tried to suggest various technologies to create optimum indoor environment by using the natural light. Therefore, this paper tried to examine the works of Le Corbusier and to analyze how to control the light in his works and apply it to his design. It will help to know how he created different characteristics to spaces by using natural light.

국내(國內) 인텔리전트 사무소(事務所) 건물(建物)의 건축계획(建築計劃) 관련지표(關聯指標) 추이(推移) 분석(分析) (An Analysis of the Transition of Architectural Data on the Intelligent Office Building in Korea)

  • 변계성
    • 한국디지털건축인테리어학회논문집
    • /
    • 제2권1호
    • /
    • pp.24-31
    • /
    • 2002
  • The purpose of this study was to analyze the transition on architectural data such as valid indoor length, module, ratio of core, floor height, ceiling height and the type of structured cabling system according to the intelligent building grade through case study of the intelligent office buildings constructed in Korea since 1980. The results of this study were as follows. The average floor height was 3.80m, and it was higher in proportion to the IB grade. The average ceiling height was 2.57m, and it didn't have connection with the IB grade. The module of high frequency in application was $3.0{\times}3.0m$, and it showed 25% in the application frequency. The average valid indoor length was 12.27m. The average ratio of core was 24.49%. The type of high frequency in application for the structured cabling was Access Floor Type, and it showed 31% in the application frequency.

  • PDF

조선시대 지방 단유(壇壝)건축 신실(神室)의 유형과 변화 (A Study on the Types and Changes of Relationship between Local Altar Architectures and Sinsil in Joseon Dynasty)

  • 신혜원
    • 건축역사연구
    • /
    • 제26권6호
    • /
    • pp.7-18
    • /
    • 2017
  • Altar architecture is a kind of sacrificial building, mainly formed in altar. Central architecture of Altar architecture is relatively simple. However, various attached building are necessary for worship. Among them, Sinsil which is a place to seal a God's tablet, is very important. The central government of the Joseon Dynasty attempted to define the local sacrificial system and make it customary as a way to strengthen the centralization based on Confucianism. Nonetheless, the altar architecture of the province without detailed regulations, were managed and underwent repairs according to the political situation of the state and local circumstances. Sinsil, which is an important component of the altar architecture, best reflects this situation. Therefore, it was possible to grasp the situation of the altar architecture of the province in the Joseon Dynasty by analyzing the Sinsil through various documents. As a result of analysis, it was divided into six types. In addition, It is also found that there are temporal relation between these six types.