• Title/Summary/Keyword: IT/IS

Search Result 319,331, Processing Time 0.286 seconds

The effectiveness of biochemical indexes for evaluating the nutrition states of children (소아에서 영양평가로서 생화학적 지표의 유용성)

  • Kim, Jae Kwang;Jin, Hyun Seong;Han, Myung Ki;Kim, Bong Seong;Cha, Choong Hwan;Park, Kie Young
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.2
    • /
    • pp.167-175
    • /
    • 2009
  • Purpose : This study has been conducted to analyze whether the biochemical nutrition indexes might be useful and effective for evaluating the nutrition states of children. Methods : We evaluated 269 children, aged 3-9 years old, who had visited Gangneung Asan Hospital for elective surgery from January 2006 to December 2007, and examined their anthropometric and preoperative laboratory data with retrospective analysis. The children were classified into underweight, normal weight, overweight, and obese groups according to body mass index (BMI). The biochemical nutrition indexes (total lymphocyte count (TLC), hemoglobin, hematocrit, serum albumin, cholesterol, et al) of each group were then analyzed statistically. Results : None of the groups showed statistically significant differences in TLC. Serum albumin decreased significantly in the underweight group. Red blood cell (RBC) count, hemoglobin, hematocrit, and serum total cholesterol in the obese group were higher than in the normal weight group. None of the groups showed statistically significant increase in mean corpuscular volume or mean corpuscular hemoglobin, and it seems that the increase of hemoglobin and RBC count in the overweight and obese groups is due to the enhancement of erythropoiesis rather than iron metabolism. However, in females, almost all nutrition indexes except albumin were statistically significantly poor. Conclusion : Serum albumin, total cholesterol, RBC count, hemoglobin, and hematocrit were useful as nutrition indexes. However, except for albumin, these indexes were significantly poor for females. More control studies are needed to confirm the effectiveness of biochemical indexes for evaluating the nutritional state of children.

Analysis of the Relation of the Positive Inotropic Action of Several Cardiotonics and Aconiti Tuber Butanol Fraction to the Frequency of Contraction of Heart Muscle (수축빈도에 따른 수종 강심약물 및 부자 부타놀 분획의 강심효과의 분석)

  • Lim, J.K.;Kim, M.S.;Shin, S.G.;Park, C.W.
    • The Korean Journal of Pharmacology
    • /
    • v.13 no.2
    • /
    • pp.1-9
    • /
    • 1977
  • The effects of extracellular calcium concentrations and several concentration of Aconiti tuber butanol fraction, norepinephrine, ouabain on the force of isometric contraction of isolated atrial preparations obtained from rabbits were determined at $11{\sim}14$ different frequencies of contraction. Qualitatively similar results were obtained in all preparations. In most preparations, rested-state contraction was induced at the range of $120{\sim}400$ seconds stimulation interval. Over the range of intervals from 120 to 10 seconds negative inotropic effect of activation (NIEA) was predominant, so the steady-state contractile force progressively declined. At the intervals of 3 seconds, changes in the cumulated negative and positive isotropic effect of activation (PIEA) practically cancelled each other under steady-state conditions. At the interval from 3 seconds to 0.25 seconds, the additional cumulation of PIEA was greater than that of the NIEA. When the intervals between contractions were shorter than 0.25 seconds, the cumulation of the NIEA was again predominant. The positive inotropic effect of cardiac glycoside resulted at least in large part from increase in the rested-state contraction. No significant effect on the PIEA was found. The decay of the NIEA was apparently greatly accelerated in the presence of high concentration of ouabain, but this may also be a reflection of their action on the state determining the strength of the rested-state contraction. In the case of extracellular calcium concentration increment, the similar results with the ouabain treatment were obtained. Norepinephrine produced more powerful inotropic effect at shorter stimulation interval than long. The rested-state contraction and the decay of the NIEA were not significantly altered in the presence of norepinephrine, but cumulated PIEA and the amount of PIEA produced by each contraction were significantly increased. Aconiti tuber butanol fraction showed similar results with that of norepinephrine. The increment of contractile force at various contraction frequency were dose-responsive in the presence of Aconiti tuber butanol fraction. It is suggested that the positive inotropic effect of Aconiti tuber butanol fraction at various contraction frequency may be due to increase of the cumulation of PIEA and the amount of PIEA produced by each beat.

  • PDF

Screening of effective control agents against bacterial soft rot on Chinese cabbage in alpine area (고랭지 배추 무름병 방제를 위한 우수약제 선발)

  • Chung, Eun-Kyoung;Zhang, Xuan-Zhe;Yeoung, Young-Rog;Kim, Byung-Sup
    • The Korean Journal of Pesticide Science
    • /
    • v.7 no.1
    • /
    • pp.32-37
    • /
    • 2003
  • Bacterial soft rot by Erwinia carotovora subsp. carotovora is one of the diseases causing the biggest problem in Chinese cabbage. Chemical screening was conducted to select effective agents for controlling bacterial soft rot. Control effect of antibiotics, plant activator, and Biokeeper (avirulent Erwinia) to soft rot were tested by in vitro assay, nursery test, and field experiment. The in vitro assay was done by paper disc method and potato slice method. The nursery test was performed by using mineral oil inoculation method with consistent disease induction. The in vitro assay showed that streptomycin, oxolinic acid, bronopol, and copper hydroxide significantly suppressed the growth of pathogenic bacterium and the decomposition of potato slice. However, plant activators including acibenzolar-S-methyl did not show the suppressive effect on the growth of pathogenic bacterium and the decomposition of potato slice. When applied by the nursery test condition using mineral oil inoculation method with Chinese cabbage 'Kangruckyeurum', Biokeeper, oxolinic acid, antibiotics streptomycin, validamycin, and copper compound provided 83.5%, 95.2%, 91.2%, 57.5% and 79.9% in control efficacy, respectively. However, the control effect of acibenzolar-S-methyl showed to be low to cause phytotoxicity. Also acibenzolar-S-methyl showed a significant control effect in the field experiment with Chinese cabbage 'Sanchon' in 2000, but the field experiment with Chinese cabbage 'Kangruckyeurum' in 2001 revealed it had phytotoxicity to Chinese cabbage. Such a difference was considered to be caused by differences in phytotoxic reaction of Chinese cabbage cultivars to the chemical. Streptomycin+copper, copper hydroxide and Biokeeper showed 79.7%, 71.9% and 60.9% in control efficacy, respectively, in the field experiment with Chinese cabbage 'Sanchon' in 2002.

Change of Residual Deltamethrin Sprayed in the Stream Water according to Wind Speed and Diffusion (풍속 및 수중확산에 따른 방역용 Deltamethrin의 수중 잔류변화)

  • Cho, Kyung-Won;Pak, Jae-Hun;Lim, Jong-Sung;Yoon, Ji-Yeong;Moon, Hye-Ree;Lee, Yong-Ju;Lee, Sung-Kyu;Lee, Kyu-Seung
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.2
    • /
    • pp.126-132
    • /
    • 2013
  • The objectives of this study were to provide the basic data of the residue of deltamethrin in the stream water. Deltamethrin was treated on side of Ban-Suk stream and Juk-Dong ditch for hygienic purpose by air spray. The drift concentration of deltamethrin was investigated with different wind speed condition on Ban-Suk stream (A), and the change of residue with time course on Juck-dong ford (B). Also we found the residual change of deltamethrin until 48 hour in Yu-Seong stream confluence (C) where two streams join. Maximum residues of A were $0.17{\mu}g/L$ (5 min, 200 m) at strong wind speed and $4.42{\mu}g/L$ (0 min, 25 m) at moderate wind speed according to different wind velocity. Residues of B were $0.15{\sim}0.26{\mu}g/L$ (0~480 min) after spraying, and decreased to a non-detected level after 720 min. Residues of C were $0.15{\mu}g/L$ (0 min), $0.11{\mu}g/L$ (1 min) and $0.10{\mu}g/L$ (12 hr) after spraying, and no residues were detected in any other samples. From these results, it is concluded that deltamethrin residues in water should be rapidly diluted into stream water and affected negligible toxic effect to stream ecosystem.

Evaluation of Uncertainty of IMRT QA Using 2Dimensional Array Detector for Head & Neck Patients (두경부암에서 2차원 배열 검출기를 이용한 IMRT QA의 불확실성에 대한 연구)

  • Ban, Tae-Joon;Lee, Woo-Suk;Kim, Dae-Sup;Baek, Geum-Mun;Kwak, Jung-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.97-102
    • /
    • 2011
  • Purpose: IMRT QA using 2Dimensional array detector is carried out with condition for discrete dose distribution clinically. And it can affect uncertainty of evaluation using gamma method. We analyze gamma index variation according to grid size and suggest validate range of grid size for IMRT QA in Hospital. Materials and Methods: We performed QA using OniPro I'mRT system software version 1.7b on 10 patients (head and neck) for IMRT. The reference dose plane (grid size, 0.1 cm; location, [0, 0, 0]) from RTP was compared with the dose plane that has different grid size (0.1 cm, 0.5 cm, 1.0 cm, 2.0 cm, 4.0 cm) and different location (along Y-axis 0 cm, 0.2 cm, 0.5 cm, 1.0 cm). The gamma index variation was evaluated by observing the level of changes in Gamma pass rate, Average signal, Standard deviation for each case. Results: The average signal for each grid size showed difference levels of 0%, -0.19%, -0.04%, -0.46%, -8.32% and the standard deviation for each grid size showed difference levels of 0%, -0.30%, 1.24%, -0.70%, -7.99%. The gamma pass rate for each grid size showed difference levels of 0%, 0.27%, -1.43%, 5.32%, 5.60%. The gamma evaluation results according to distance in grid size range of 0.1 cm to 1.0 cm showed good agreement with reference condition (grid size 0.1 cm) within 1.5% and over 5% in case of the grid size was greater than 2.0 cm. Conclusion: We recognize that the grid size of gamma evaluation can make errors of IMRT QA. So we have to consider uncertainty of gamma evaluation according to the grid size and apply smaller than 2 cm grid size to reduce error and increase accuracy clinically.

  • PDF

Study on Dosimetry Used TLD Dosimeter and Body Mass Index at Total Body Irradiation (전신조사방사선치료에서 열형광선량계를 이용한 선량 측정과 체질량지수에 관한 고찰)

  • Seo, Dong-Rin;Kim, Yeon-Soo;Kim, Dae-Sup;Yoon, Hwa-Ryong;Back, Geum-Mun;Kwak, Jung-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • Purpose: The aim of study is to expose a more uniform dose depending on the relationship between a body mass index in patients who underwent radiation therapy and an acquired dosimetric information by using a thermoluminescent dosimeter. Materials and Methods: Since 2006 to August 2011 we investigated 28 people who underwent radiation therapy were enrolled in AMC. Each patient was measured on the head, neck, chest, abdomen, pelvis, thigh, knee joint, and ankle joint using the thermoluminescent dosimeter. The measurement value of each points compared with the prescribed center point, abdominal point, and dose measurements of points on which to base the abdomen and the patient's body mass index (BMI) were compared with reference point, abdomen dose. Results: 28 patients on prescribed dose in the abdomen by which the center point, an average dose was $100.6{\pm}5.5%$, and the other seven measuring points with the average maximum difference among the head, neck, chest, pelvic, thigh, knee, and ankle were $92.8{\pm}4.2%$, $97.6{\pm}6.2%$, $96.4{\pm}5.5%$, $102.6{\pm}5.3%$, $103.4{\pm}7.9%$, $95.8{\pm}5.9%$, $96.1{\pm}5.5%$. The relationship of abdominal point dose and the patient's body mass index (BMI) was analyzed a scatter plot, and the result of linear relationship analysis by regression method, the regression of the dose (y) was -1.009 BMI (x) plus 123.3 and coefficient of determination ($R^2$) was represented 0.697. Conclusion: The total body irradiation treatment process was evaluated the dose deviation and then the prescribed dose by which the average abdominal dose was satisfied with $100.6{\pm}5.5%$. Results of the relationship analysis between BMI and dose, if we apply the correction value for each patients, it can be achieved more uniform dose delivery.

  • PDF

Analysis on Longitudinal Dose according to Change of Field Width (선속 폭(Field Width) 변화에 따른 종축선량 분석)

  • Jung, Won-Seok;Back, Jong-Geal;Shin, Ryung-Mi;Oh, Byung-Cheon;Jo, Jun-Young;Kim, Gi-Chul;Choi, Tae-Gu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.109-117
    • /
    • 2011
  • Purpose: To analyze the accuracy of tumor volume dose following field width change, to check the difference of dose change by using self-made moving car, and to evaluate practical delivery tumor dose when tomotherapy in the treatment of organ influenced by breathing. Materials and Methods: By using self-made moving car, the difference of longitudinal movement (0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm) was applied and compared calculated dose with measured dose according to change of field width (1.05 cm, 2.50 cm, 5.02 cm) and apprehended margin of error. Then done comparative analysis in degree of photosensitivity of DQA film measured by using Gafchromic EBT film. Dose profile and Gamma histogram were used to measure degree of photosensitivity of DQA film. Results: When field width were 1.05 cm, 2.50 cm, 5.02 cm, margin of error of dose delivery coefficient was -2.00%, -0.39%, -2.55%. In dose profile of Gafchromic EBT film's analysis, the movement of moving car had greater motion toward longitudinal direction and as field width was narrower, big error increased considerably at high dose part compared to calculated dose. The more field width was narrowed, gamma index had a large considerable influence of moving at gamma histogram. Conclusion: We could check the difference of longitudinal dose of moving organ. In order to small field width and minimize organ moving due to breathing, it is thought to be needed to develop breathing control unit and fixation tool.

  • PDF

Feasibility of MatriXX for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료의 품질관리를 위한 이온전리함 매트릭스의 유용성 고찰)

  • Kang, Min-Young;Kim, Yoen-Lae;Park, Byung-Moon;Bae, Yong-Ki;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.91-97
    • /
    • 2007
  • Purpose: To evaluate the feasibility of a commercial ion chamber array for intensity modulated radiation therapy (IMRT) quality assurance (QA) was performed IMRT patient-specific QA Materials and Methods: A use of IMRT patient-specific QA was examined for nasopharyngeal patient by using 6MV photon beams. The MatriXX (Wellhofer Dosimetrie, Germany) was used for IMRT QA. The case of nasopharyngeal cancer was performed inverse treatment planning. A hybrid dose distribution made on the CT data of MatriXX and solid phantom all of the same gantry angle (0$^\circ$). The measurement was acquired with geometrical condition that equal to hybrid treatment planning. The $\gamma$-index (dose difference 3%, DTA 3 mm) histogram was used for quantitative analysis of dose discrepancies. An absolute dose was compared at the high dose low gradient region. Results: The dose distribution was shown a good agreement by gamma evaluation. A proportion of acceptance criteria was 95.8%, 97.52%, 96.28%, 98.20%, 97.78%, 96.64% and 92.70% for gantry angles were 0$^\circ$, 55$^\circ$, 110$^\circ$, 140$^\circ$, 220$^\circ$, 250$^\circ$ and 305$^\circ$, respectively. The absolute dose in high dose low gradient region was shown reasonable agreement with the RTP calculation within $\pm$3%. Conclusion: The MatriXX offers the dosimetric characteristics required for performing both relative and absolute measurements. If MatriXX use in the clinic, it could be simplified and reduced the IMRT patient-specific QA workload. Therefore, the MatriXX is evaluated as a reliable and convenient dosimeter for IMRT patient-specific QA.

  • PDF

A Study on the Relationship between Standardization and Technological Innovation: Panel Data and Canonical Correlation Analysis through the use of Standardization Data and Patent Data (표준과 기술혁신의 관계에 관한 연구: 표준 제정·보유정보와 특허정보를 이용한 패널데이터 분석 및 정준상관 분석)

  • Lee, Heesang;Kim, Sooncheon;Jeon, Yejun
    • Journal of Korea Technology Innovation Society
    • /
    • v.19 no.3
    • /
    • pp.465-482
    • /
    • 2016
  • Previous researches have introduced various ways to analyze the impact of standardization on innovation while the works are not only small in number but based on interview or case study. This paper addresses the impact of standardization activities within South Korean industries on technological innovation applying an empirical analysis of standardization activities and technological innovation. Drawing on Korean Industrial Standards Classification from panel data of 2003 to 2012, we employed corresponding data of each industrial classification: Number of standards, Accumulated number of standards, Number of patents applied in Korea, Sales, Operational profit, Intangible asset, and R&D invest. In the first model, we run panel data models employing the number of patents applied in Korea as an independent variable, and the number of standards, accumulated number of standards, sales, and operational profit as dependent variables to observe industrial impacts upon the relationship between standards and patents, along with time lagged consideration. The result shows that number of standards are revealed to have a negative influence on patent applications in the year of research, and no significant effect appears for the next two years while positive effect shows up on the third year. Meanwhie, accumulated number of standards turned out to have positive effects on patent applications in Korea. This implies it takes time for innovation subjects to embrace newly established standards while having a significant amount of positive effect on technological innovation in the long term. In the second model, we use canonical correlation analysis to find industrial-wide characteristics. The result of this model is equivalent to the result of panel data analysis except in a few industries, where some industry specific characteristics appear. The implications of our results present that Korean policy makers have to take account of industrial effects on standardization to promote technological innovation.

Relation of Ethanol and Calcium to Contractile and Electrical Activity of Cat Stomach (고양이 위(胃)의 수축 및 전기활동에 대한 에탄올과 칼슘의 관계)

  • Kim, Myung-Suk;Sim, Sang-Soo;Yoon, Shin-Hee;Han, Sang-Jun;Kim, Chung-Chin;Choi, Hyun
    • The Korean Journal of Physiology
    • /
    • v.21 no.2
    • /
    • pp.259-272
    • /
    • 1987
  • This was study carried out to investigate the effect of calcium on spontaneous contraction and electrical activity induced by ethanol in gastric smooth muscle. After peeling off the mucous membrane from the isolated whole stomach of 102 cats, two kinds of small muscle preparations $(2.0{\times}0.2\;cm)$, one longitudinal and the other circular, were excised from the fundus, the corpus and the antrum portion of each whole stomach specimen. The isometric contraction of the small muscle preparation was measured in a cylinder-shaped chamber filled with Krebs-Ringer-dextrose solution (pH 7.4, temperature $36{\pm}0.5^{\circ}C$) bubbling with 5% $CO_2$ in $O_2$. A large muscle preparation $(5.0{\times}1.2\;cm)$ was excised from the anterior wall of the corpus-antrum portion of the same specimen in 72 of 102 cats. The gastric electrical activity (slow wave and spike potential) was monopolarly recorded by four capillary electrodes (Ag-AgCl), of which two were placed on the corpus and two on the antrum, in a muscle chamber filled with the same solution as described above. Changes in the amplitude of the contraction, frequency of the gastric slow wave and the production of the spike potential were observed after adding ethanol and/or under the treatments with verapamil, $CaCl_2$ and Ca-free Krebs-Ringer-dextrose solution. The results were as follows: 1) After adding ethanol, the spontaneous phasic contraction of the corpus was reduced dose-dependently (0.125-2.0%), which was totally abolished by higher concentrations (2.0-8.0%) of ethanol. 2) The corporal phasic contraction was also completely abolished by verapamil $(3{\times}10^{-5}\;M)$ or Ca-free Krebs-Ringer-dextrose solution. The contraction was increased by $CaCl_2\;(1.8{\times}10^{-3}\;M)$, but the inhibitory effect of ethanol on the contraction persisted even under the treatment with $CaCl_2$. 3) At higher concentrations, ethanol caused tonic contraction of both preparations from the fundus, the corpus and the antrum in a dose-dependent manner. The tonic contraction of the fundus produced by ethanol was not influenced by $CaCl_2$ or verapamil, whereas the tonic contraction was not produced by ethanol in tile Ca-free solution. 4) Frequency of gastric slow wave was decreased dose-dependently by the addition of ethanol (0.25-1.0%), and tile slow wave was not produced by higher concentration of ethanol (2.0%). 5) The frequency of slow wave was significantly reduced by verapamil only and the inhibitory influence of ethanol on the slow wave frequency was reinforced by verapamil. 6) The treatment of $CaCl_2$ increased significantly the slow wave frequency, and attenuated the inhibitory effect of ethanol on the frequency. It is therefore suggested that ethanol regulates the phasic contraction and the production of slow wave by interfering with the transport of calcium in the stomach muscle of the cat.

  • PDF