Study on Dosimetry Used TLD Dosimeter and Body Mass Index at Total Body Irradiation

전신조사방사선치료에서 열형광선량계를 이용한 선량 측정과 체질량지수에 관한 고찰

  • Seo, Dong-Rin (Department of Radiation Oncology, Asan Medical Center) ;
  • Kim, Yeon-Soo (Department of Radiation Oncology, Asan Medical Center) ;
  • Kim, Dae-Sup (Department of Radiation Oncology, Asan Medical Center) ;
  • Yoon, Hwa-Ryong (Department of Radiation Oncology, Asan Medical Center) ;
  • Back, Geum-Mun (Department of Radiation Oncology, Asan Medical Center) ;
  • Kwak, Jung-Won (Department of Radiation Oncology, Asan Medical Center)
  • 서동린 (서울아산병원 방사선종양학과) ;
  • 김연수 (서울아산병원 방사선종양학과) ;
  • 김대섭 (서울아산병원 방사선종양학과) ;
  • 윤화룡 (서울아산병원 방사선종양학과) ;
  • 백금문 (서울아산병원 방사선종양학과) ;
  • 곽정원 (서울아산병원 방사선종양학과)
  • Received : 2011.05.20
  • Accepted : 2011.07.28
  • Published : 2011.09.30

Abstract

Purpose: The aim of study is to expose a more uniform dose depending on the relationship between a body mass index in patients who underwent radiation therapy and an acquired dosimetric information by using a thermoluminescent dosimeter. Materials and Methods: Since 2006 to August 2011 we investigated 28 people who underwent radiation therapy were enrolled in AMC. Each patient was measured on the head, neck, chest, abdomen, pelvis, thigh, knee joint, and ankle joint using the thermoluminescent dosimeter. The measurement value of each points compared with the prescribed center point, abdominal point, and dose measurements of points on which to base the abdomen and the patient's body mass index (BMI) were compared with reference point, abdomen dose. Results: 28 patients on prescribed dose in the abdomen by which the center point, an average dose was $100.6{\pm}5.5%$, and the other seven measuring points with the average maximum difference among the head, neck, chest, pelvic, thigh, knee, and ankle were $92.8{\pm}4.2%$, $97.6{\pm}6.2%$, $96.4{\pm}5.5%$, $102.6{\pm}5.3%$, $103.4{\pm}7.9%$, $95.8{\pm}5.9%$, $96.1{\pm}5.5%$. The relationship of abdominal point dose and the patient's body mass index (BMI) was analyzed a scatter plot, and the result of linear relationship analysis by regression method, the regression of the dose (y) was -1.009 BMI (x) plus 123.3 and coefficient of determination ($R^2$) was represented 0.697. Conclusion: The total body irradiation treatment process was evaluated the dose deviation and then the prescribed dose by which the average abdominal dose was satisfied with $100.6{\pm}5.5%$. Results of the relationship analysis between BMI and dose, if we apply the correction value for each patients, it can be achieved more uniform dose delivery.

목 적: 전신조사방사선치료를 시행한 환자에서 체질량지수와 열형광선량계를 이용한 선량측정 정보를 비교 분석하여 환자에게 보다 균등한 선량을 조사하고자 한다. 대상 및 방법: 2006년부터 2011년 8월까지 전신조사방사선치료를 시행한 환자 28명을 대상으로 하였다. 각 환자는 열형광선량계를 이용하여 두부, 경부, 흉부, 복부, 골반부, 대퇴부, 슬관절부, 족관절부에서 선량을 측정하였다. 각각의 환자에 대하여 처방 중심점인 복부점과 각 측정점에서의 선량측정치를 비교하였고, 선량기준이 되는 복부점의 측정값과 환자의 체질량지수를 비교 분석하였다. 결 과: 28명 환자에서 처방에 기준이 되는 중심점인 복부선량은 평균 $100.6{\pm}5.5%$이었고, 복부점과 다른 7개의 측정점 평균값과의 최대 차이는 두부, 경부, 흉부, 골반부, 대퇴부, 슬관절부, 족관절부에서 각각 $92.8{\pm}4.2%$, $97.6{\pm}6.2%$, $96.4{\pm}5.5%$, $102.6{\pm}5.3%$, $103.4{\pm}7.9%$, $95.8{\pm}5.9%$, $96.1{\pm}5.5%$였다. 각각의 환자에 대하여 복부점의 선량과 환자의 체질량지수와 관계를 산점도(scatter plot)로 나타내고 선형관계를 회귀분석 한 결과, 회귀직선은 선량(y)=-1.009 BMI (x)+123.3이고 $R^2$값은 0.697로 나타났다. 결 론: 전신방사선치료시 열형광선량계로 측정된 자료를 바탕으로 선량을 평가하였고 분석 결과 처방 선량에 대하여 기준이 되는 복부선량은 평균 $100.6%{\pm}5.5%$로 만족하였다. 본 실험결과 체질량지수와 선량과의 관계 분석을 통하여 얻은 정보에 따라 체질량지수가 높은 환자에 대하여 보정 값을 적용한다면 보다 균등한 선량을 달성할 수 있을 것으로 사료된다.