프리스트레스트 콘크리트 슬래브의 내화성능 예측에 대한 해석적 연구 (Analytical Study on Fire Resistance Predictions of Prestressed Concrete Slabs)

  • 민정기;박민재;주영규
    • 한국공간구조학회논문집
    • /
    • 제17권1호
    • /
    • pp.69-75
    • /
    • 2017
  • In fire design for floors, the three criteria of stability, integrity and insulation are required for the specified fire resistance duration. Among these, stability is not easy to confirm. For solid prestressed concrete slabs of uniform thickness, Eurocode 2 provides tabulated data and specifies an axis distance to the centroid of strands to achieve particular fire resistance ratings, but it is not clear if this data can be used for a wide range of different prestressed slab profiles. In order to verify the current code-fire ratings for precast prestressed slabs, both simple and advanced calculation methods are investigated. This paper examines the use of calculation methods, accounting for the real behaviour of unprotected simply supported prestressed concrete slabs exposed to the standard ISO 834 fire. The calculated fire resistance of each prestressed concrete slab is compared with tabulated data in Eurocode part 1.2, with detailed discussion.

누전차단기 절연재료의 소손 특성에 관한 연구 (A Study on the Damage by Burning Characteristics of Insulating Materials of RCD)

  • 이춘하;김시국;옥경재;지승욱
    • 한국화재소방학회논문지
    • /
    • 제23권2호
    • /
    • pp.62-66
    • /
    • 2009
  • 본 연구는 국내에서 사용되고 있는 누전차단기 외함 절연재료의 소손 특성에 대하여 연구하였다. 시료는 3개 제조사의 누전차단기 외함 절연재료를 사용하였으며, 시료의 열분해특성, 연소특성, 트래킹 특성 등을 비교 분석하였다. 열분해특성은 TGA를 사용하였으며, 연소특성은 ISO5660(Fire Tests - Reaction to Fire, part 1)을 만족하는 Mass Loss Calorimeter(FTT 사)를 사용하였고, 트래킹 특성은 고체 절연재료의 내트래킹 및 비교트래킹 지수를 측정하는 실험인 KSC IEC 60112.의 기준에 따라 분석하였다. 연구결과 A제조사의 경우 내트래킹성이 가장 우수하였고, B제조사의 경우 내트래킹성이 가장 낮은 반면 $350^{\circ}C$ 이상의 고온에서 열안정성이 가장 우수하였으며, C제조사의 경우 $400^{\circ}C$ 이하의 온도에서 열안정성이 가장 우수한 것을 알 수 있었다.

섬유혼입된 50 MPa 고강도 콘크리트의 내화성능 (Fire Resistance Performance of Fiber-Cocktail Reinforced 50 MPa High Strength Concrete)

  • 염광수;전현규;박종헌
    • 한국재난관리표준학회지
    • /
    • 제2권3호
    • /
    • pp.55-60
    • /
    • 2009
  • 현재 많이 사용되고 있는 50MPa 고강도 콘크리트에 대해서 섬유혼입공법(폴리프로필렌섬유와 강섬유)을 적용하여 국토해양부 시행령에 따라 2가지 다른 섬유혼입량을 가진 총 4기의 시험체를 제작하여 ISO 834 표준내화곡선에 따라서 180분간 내화시험을 실시하여 폭렬발생여부, 철근과 콘크리트의 온도분포를 통해 내화성능을 평가하였다. 내화시험 후 모든 시험체에 폭렬은 발생하지 않았으며, 폭렬방지를 위해서 요구되는 최소 폴리프로필렌섬유량은 콘크리트 단위용적당 0.57 kg이상 이다. 섬유혼입량에 따른 콘크리트와 종방향철근의 온도분포를 비교한 결과, 섬유혼입량에 따른 차이는 없다고 판단된다.

  • PDF

Experimental studies on the behaviour of headed shear studs for composite beams in fire

  • Lim, Ohk Kun;Choi, Sengkwan;Kang, Sungwook;Kwon, Minjae;Choi, J. Yoon
    • Steel and Composite Structures
    • /
    • 제32권6호
    • /
    • pp.743-752
    • /
    • 2019
  • Steel and concrete composite structures are commonly applied in multi-story buildings as they maximise the material strength through composite action. Despite the popularity of employing a trapezoidal deck slab, limited experimental data are available under elevated temperatures. The behaviour of the headed shear stud embedded in a transverse trapezoidal deck and solid slab was investigated at both ambient and fire conditions. Twelve push-out tests were conducted according to the ISO 834 standard fire utilising a customised electric furnace. A stud shearing failure was observed in the solid slab specimen, whereas the failure mode was changed from a concrete-dominated failure to the stud shearing in the transverse deck specimen with an increase in temperature. Comparisons between the experimental observations and design requirements are presented. The Eurocode design guidance on the transverse deck slab gives a highly conservative estimate for shear resistance. A new design formula was proposed to determine the capacity of the shear connection regardless of the slab type when the stud shearing occurs at high temperatures.

Flexural performance of fire damaged and rehabilitated two span reinforced concrete slabs and beams

  • Yu, Jiang-Tao;Liu, Yuan;Lu, Zhou-Dao;Xiang, Kai
    • Structural Engineering and Mechanics
    • /
    • 제42권6호
    • /
    • pp.799-813
    • /
    • 2012
  • Five two-span reinforced concrete (RC) slabs and seven two-span RC beams were tested under the ISO 834 standard fire with different durations. CFRP strengthening was then applied to some of the specimens after the damaged concrete was removed from the specimens and replaced with polymer mortar. All the specimens were loaded to failure to investigate the influence of fire-damage and the effectiveness of strengthening methods. Test results indicated that the flexural capacities of specimens decrease with the fire duration increases. Moreover, fire exposure had more significant effect on the flexural rigidity than on the bearing capacity of the specimens. After rehabilitation, the bearing capacities of specimens reached or even exceeded that of the reference RC specimen, and the strengthening methods seemed to have limited effect on flexural rigidity recovery. From the analysis of moment redistribution of tested beams, elevated temperature is found having different impacts on sagging moment region and hogging moment region. The damage of RC continuous member is definitely a comprehensive response of different regions.

철도차량용 통로연결막 재료별 독성성분의 발생량 비교 (Occurrence quantity comparison of the toxic gases of the railway car's gangway materials using a Smoke Density-Chamber)

  • 이은경;이덕희;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1533-1539
    • /
    • 2007
  • It is mainly due to the toxic gases, produced from the material combustion, threatens human body in case of urban railway car like subway which passes through underground tunnel. In the field of railway industry, fire accidents was not frequent but occurs in each country and, the causes was investigated. The advanced country established the test standard (e.g., BS, EN) to measure the toxic gases quantitatively and, have applied to enhance the fire safety of railway car. We must also follow the procedures to use gangway material for railway car as stated the Safety regulation for the urban railway car. In this study, various gangway materials(silicon, synthtic rubber, soaltapulin) are used to investigate element of toxic gases when the fire occurs. The amount of toxic gases measured from the ISO 5659 chamber using cone heater was measured and compared the results for each materials.

  • PDF

유기 단열재의 화재위험성 등급 평가 (Fire Risk Rating Evaluation of Organic Insulation Materials)

  • 유지선;전남;정영진
    • 공업화학
    • /
    • 제32권4호
    • /
    • pp.417-422
    • /
    • 2021
  • 본 연구에서는 유기 단열재인 poly isocyanurate foam (PIR), poly urethane foam (PUR), phenol foam (PF)을 선정하여 ISO 5660-1의 기준에 따라 콘칼로리미터(cone calorimeter)를 이용하여 측정하였다. 화재위험성 평가를 표준화하기 위하여 기준물질(PMMA)을 사용하여 Chung's equations-III와 Chung's equation-IV에 의한 화재위험성을 등급화하여 평가하였다. Chung's equations-II의 화재성능지수-II 값은 PF가 14.77 s2/kW로 화재성능지수-II가 가장 높았고, PUR이 0.08 s2/kW로 화재성능지수-II가 가장 낮았다. 화재성장지수-II 값은 PF가 0.01 kW/s2로 화재성장지수-II가 가장 낮았고, PUR이 1.14 kW/s2로 화재성장지수-II가 가장 높았다. Chung's equations-III의 화재성능지수-III에서 PUR이 0.11로 화재성능지수-III가 가장 낮게 나타났고, PF가 20.23으로 화재성능지수-III가 가장 높았다. FGI-III에서는 PUR이 14.25로 화재성장지수-III가 가장 높게 나타났고, PF가 0.13으로 가장 안전한 물질로 판단하였다. 그리고 Chung's equation-IV의 화재위험성지수-IV는 PUR (130.03) >> PIR (19.13) > PMMA (1.00) > PF (0.01)의 순서로 나타났다. 따라서 PF가 화재위험성이 가장 낮고, PUR이 가장 높은 것으로 판단하였다.

공기층과 에어로젤을 이용한 특수방화복 경량화 연구 (Study on the Weight Reduction of Firefighter's Protective Clothing by Using Air Layer and Aerogels)

  • 김해형;박평규;김영수;홍승태
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.81-88
    • /
    • 2018
  • 공기와 초경량 소재인 에어로젤을 이용하여 소방용 특수방화복의 무게를 경량화하고자 하였다. 3겹(겉감, 중간층, 안감)으로 구성된 특수방화복을 경량화하기 위해서는 총무게에서 가장 큰 비중을 차지하는 안감을 신소재로 대체하는 것이 가장 효과적이었다. 열보호 성능시험은 대류 열원(ASTM D 4108), 복사 열원(KS K ISO 6942) 및 대류와 복사 혼합 열원(KS K ISO 17492)에 대해 수행하였다. 안감의 펠트를 공기층으로 대체하였을 경우 공기층이 최소 3 mm 이상일 때 열보호 성능이 KFI와 ISO 기준을 충족하였다. 그러나 공기층의 두께가 10 mm까지 늘어나도 열보호 성능이 기존 제품의 성능에 미치지 못했다. 안감의 펠트를 에어로젤로 대체하였을 경우 에어로젤의 두께가 2 mm일 때 TPP (ASTM D 4108) 값이 KFI 기준을 충족하였으며, 에어로젤의 두께가 3 mm일 때는 TPP 값이 기존 특수방화복보다 약 140% 향상되었다. 에어로젤을 사용할 경우 특수방화복의 경량화 뿐만 아니라 열보호 성능까지 향상됨을 확인하였다. 그러나 에어로젤은 부서지기 쉬운 성질이 있어서 특수방화복을 구성하는 층 사이에 일정한 두께로 고정시키는 방법이 향후 고려되어야 한다.

신형상 U형 하이브리드 합성보의 내화성능에 관한 연구 (Fire Resistance of U-shape Hybrid Composite Beam)

  • 김성배;김상섭;유덕수;최승관
    • 한국강구조학회 논문집
    • /
    • 제25권4호
    • /
    • pp.379-388
    • /
    • 2013
  • 본 연구에서는 신형상 U형 하이브리드 합성보의 내화성능평가를 실시하였다. 내화성능평가는 세라믹계의 뿜칠재와 내화페인트로 구분하여 내화시험을 수행하였다. 시험 변수는 피복재의 종류(뿜칠재와 페인트)와 내화시간(2시간, 3시간), 하중가력 유무(재하와 비재하), 뿜칠재 두께 등이다. 내화성능평가 합성보는 기존 철골보로 인정을 받은 제품에 비해 내화성능이 향상되는 것을 확인할 수 있다. 그러나 내화성능 향상에 대한 정량적인 평가는 합성보 형상과 관련한 다양한 변수가 조합되므로 지속적인 검토가 필요할 것으로 판단된다.

탄소재료의 적용 방법에 따른 파티클 보드의 연소 특성 (Evaluation of Fire Characteristics for Particle-board with Exfoliated Graphite Nanoplatelets Added)

  • 서현정;조정민;황욱;이민철
    • 한국연소학회지
    • /
    • 제22권4호
    • /
    • pp.1-8
    • /
    • 2017
  • This study was conducted to evaluate the fire retardant performance of exfoliated graphite nanoplatelets (xGnP) applied for particleboard. This work measured heat release rate(HRR), total heat release(THR) and smoke production rate(SPR) of xGnP added particleboard, using cone calorimeter to assess its fire characteristics according to the KS F ISO 5660-1 standard code. Heat release rates of all specimens treated by xGnP were less than the $200kW/m^2$ for a total experiment period of five minutes. Heat release rates of the specimens coated with xGnP were lower than those of the specimens made by mixing wood particles with xGnP directly. Meanwhile, the total heat release rates of xGnP coated specimen maintained quite lower level than the uncoated so the xGnP coating were effective in improving the fire retardant performance of particleboard. However, the smoke emission peaking problem at the initial combustion period, which was caused by adding base coating materials, should be resolved for further satisfaction as a fire retardant materials.