• 제목/요약/키워드: ISO Standard Fire

검색결과 110건 처리시간 0.03초

도로터널 라이닝 화재조건 콘크리트 라이닝 공극압력 특성에 관한 연구 (A Study on Pore Pressure Evaluation of Concrete Lining in Road Tunnel Fire)

  • 박경훈;김흥열;유용호;이철호;김형준
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.484-489
    • /
    • 2008
  • We carried out a one-way heating experiment on the PC panel manufactured by changing the filling depths(20,30,40,50mm) of concrete regarding the fire strength in order to measure the inner concrete pressure which is a direct cause of concrete spalling. This fire experiment was conducted under the fire strength conditions of ISO 834 Standard, Modified Hydrocarbon and the maximum value of Pore Pressure was measured. As a result of analyzing the time it took to reach maximum pressure, it showed that the time rising to the maximum pressure of high strength concrete of 40MPa is slower than that of a 24MPa tunnel lining. In case of ISO fire conditions, spalling damage might take place in heating period of $20{\sim}40$ minutes in the range of $100{\sim}200^{\circ}C$ temperature. In case of MHC fire conditions, the area damaged by fire can appear after a lapse of $25{\sim}50$ minutes in the range of $150{\sim}250^{\circ}C$ temperature.

  • PDF

질소와 노벡 혼합가스를 이용한 청정소화약제의 소화성능에 관한 연구 (A Study on Clean Agent Fire Extinguishing Ability Using Nitrogen and Novec Mixtures Gas)

  • 임우섭;정종진;남동군;사공성호;김종원;최근주
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.76-83
    • /
    • 2008
  • In the course of increasing in human and material damage caused by fire, it is an important research field to develop clean extinguishing agent which does no harm to global environment as well as has a good extinguishing efficiency. This research is a basic step to develop a new clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using nitrogen and Novec mixtures gas which are inert gas and new clean extinguishing agent. We used Cup Burner Test made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test, and the fuels used in the test are n-heptane, methanol, ethanol, iso-propanol and 1-butanol. The experimental results of flame extinguishing concentration are n-heptane 6.54%, methanol 8.47%, ethanol 6.98%, isopropanol 6.10% and butanol 6.54% by pure Novec agent. So the finding is that a new clean agent, Novec has an efficient extinguishing ability in a state of gas. Also, in a test as to mixtures gas of nitrogen and Novec, it has a good result for minimum oxygen concentration is under 16%.

반밀폐된 ISO 9705 화재실에서 비정상 화재특성 예측을 위한 FDS의 성능평가 (Performance Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed ISO 9705 Room)

  • 문선여;황철홍
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.21-28
    • /
    • 2012
  • 비정상(unsteady) 화재성장이 발생되는 반밀폐된 구획에서 환기부족화재의 열 및 화학적 특성에 관한 FDS(Fire Dynamics Simulator)의 예측성능 평가가 수행되었다. 이를 위해 실규모 ISO 9705 표준 화재실의 출입구 폭이 0.1 m로 축소되었으며, spray 노즐을 통해 Heptane 연료유량은 선형적으로 증가되었다. 수치계산에 대한 신뢰도 확보를 위하여 동일 조건에서 수행된 실험결과와의 상세한 비교가 이루어졌다. 적절한 격자계를 이용한 FDS의 결과는 구획 내부의 온도 및 열유속(heat flux)은 비교적 잘 예측하지만, 비정상 CO 및 $CO_2$ 생성특성은 적절히 예측하지 못함을 확인하였다. 이러한 결과는 최근 수행된 유사조건의 정상상태 환기부족 구획화재에 대한 FDS 예측결과와 상반된 것으로서, 반밀폐된 구획화재 모델링에서 FDS를 이용한 비정상 CO 생성특성 예측에 상당한 주위가 요구됨을 확인하였다.

화재피해를 입은 RC 슬래브의 재하실험에 관한 연구 (A Study on the loading test for of slab by Fire damaged)

  • 이규민;강승구;김동준;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.50-51
    • /
    • 2013
  • In case of Korea, it goes frequently that underground parks has been burned. Based on standard temperature time curve(ISO-834), gerber, walls, slab of structures are constructed. However, Standard temperature time Curve is not considered that buildings are affected by vehicle fire. that is why it has the hazard that makes building reinforcement feeble. Based on the result that got from vehicle experiment before, we made four RC slab in this experiment and set the fire severity. according to the loading experiment after heating, we measured the effects that makes reinforcement and shape changes. Furthermore, we examined the safty of the structure by comparing before and after heating.

  • PDF

한국 소방용 방화복의 치수체계 개발 (Sizing System Development of Korean Structural Firefighting Protective Clothing)

  • 한설아;남윤자;최영림
    • 한국의류학회지
    • /
    • 제33권5호
    • /
    • pp.827-839
    • /
    • 2009
  • Sizing system of Korean structural firefighting protective clothing that is national approved should be met for specification of structural firefighting protective clothing that is identified by Ministry of Public Administration and Security(MOPAS). However if you look over the specification of sizing system, the standard is based on only 'height' and the others are indicated as the size of completed product. KS K ISO 13688 and EN 340 which is met on ISO 13688 which indicates sizing system about protective clothing has the standards of height, chest and waist circumference. Also NFPA 1971 that has standards of sizing system is based on chest circumference, cervical to wrist length, waist circumference and inseam. That is different from Korean standards. Therefore, fire fighting protective clothing standards which is based on only height should be compensated and not be relied on foreign standards like ISO. It is indispensable for developing our own sizing system of structural fire fighting protective clothing. In this studying, Korean new sizing system of structural fire fighting protective clothing was developed for providing basic information of ergonomic structural fire fighting protective clothing. The analyzed target age was between 20 and 59 years old fire fighter who extinguish the fire. And it was analyzed by 3D measurement among data of the $5^{th}$ Size Korea. On conclusion, in case of structural fire fighting protective clothing coat, physical dimension was to be chest circumference, cervical to wrist length. Three dimensions as 5cm space of circumference and four dimensions as 2.5cm space of cervical to wrist length were derived, which means that totally 12 dimensions were defined. Dimension standards of pants was based on the analysis of waist circumference and crotch height. Six dimensions as 5cm space of waist circumference and three dimensions as 5cm space of crotch height were derived, which means that totally 14 dimensions were defined.

배관용 보온재의 난연 성능 시험방법에 따른 최대 발열량 분석 (Analysis of the Maximum Heat Release Rate in Accordance with the Test Method of the Flame Retardant Performance for Pipe Insulation)

  • 유우준;박정욱;신연제;박형규;임옥근
    • 한국화재소방학회논문지
    • /
    • 제34권1호
    • /
    • pp.18-25
    • /
    • 2020
  • 본 연구에서는 보온재의 설치 상태를 고려한 ISO 20632와 NFPA 274 시험 기준에 따른 발열량 산출 결과를 분석하였다. 이를 위해서 보온재 총 6종(은박 발포폴리에틸렌(PE(S)), 무은박 발포폴리에틸렌폼(PE(N)), 고무발포(Rubber), 일본-폴리에틸렌폼(PE(J)), 일본-폴리우레탄폼(PU(J)) 그리고 일본-스티로폼(ST(J)))에 대해서 EN 13501-1과 화재성장곡선에 따른 난연 등급을 구분하였다. 그 결과 PU(J), PE(J) 그리고 PE(N)는 Class E 및 Ultra-fast, NFPA 274 시험기준에 의한 PE(S)는 Class D 및 Fast, ISO 20632에 의한 PE(S)는 Class C 및 Slow, 그리고 Rubber와 ST(J)는 Class B 및 Slow로 나타났다. 하지만, 난연 등급 평가 기준인 최대 발열량에 대한 시간평균 기울기는 시험 방법에 따라서 동일 보온재에 대하여 다르게 나타났으며, 보다 정확한 원인을 분석하기 위한 기초 연구가 필요한 것으로 판단된다.

비재하 가열에 의한 무내화피복 CFT 기둥의 잔존내력 예측에 관한 연구 (A Study on the Prediction of Residual Strength of Concrete Filled Steel Tube Column without Fire Protective Coating by Unstressed Heating)

  • 김규용;이형준;이태규;김영선;강선종
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.31-39
    • /
    • 2009
  • 최근 고층건물의 화재안전성에 대한 문제점이 사회적으로 부각되어지고 있으며, 이러한 고층 건물에 다수 사용되고 있는 CFT기둥 부재에 대한 내화성능을 정량적으로 평가하는 방법이나 기준들이 마련되지 않은 상황이다. 이에 본 연구에서는 고강도 콘크리트를 충전한 CFT 단주를 제작하여 내화실험을 실시하고, 화재시 내화성능평가 및 비정상온도분포해석을 이용한 해석을 수행하여 온도분포해석의 모델링을 제안할 수 있었다. 이것을 기초로 CFT Stub Column의 고온특성 평가결과를 활용하여 화재시 내화시간에 따른 CFT기둥의 잔존내력 예측식을 유도할 수 있었다.

화재 시 하중 재하 조건에 따른 중공슬래브의 내화거동 및 잔존성능 (Fire Resistance Behavior and Residual Capacity of Voided Slab Subjected to Fire According to Loading Condition)

  • 최현기;배백일;정형석;최창식;정주홍
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.99-106
    • /
    • 2018
  • 본 연구는 하중 조건에 따른 화해를 입은 중공슬래브의 잔류성능에 대한 실험적 연구이다. 이를 평가하기 위하여, 하중조건을 변수로 하는 2개의 중공슬래브 실험체를 제작하여 ISO 834 표준화재 곡선에 따라 120분간 가열하였으며, 이를 상온으로 냉각하여 잔류 휨 성능을 평가하였다. 실험결과 하중조건에 따라 중공슬래브의 온도분포가 상이한 것으로 나타났으며, 재하 실험체가 비재하 실험체에 비해 전단면에 걸쳐 온도가 빠르게 상승하는 경향을 보임을 확인하였다. 고온으로 가열 후 냉각한 중공슬래브의 잔류 휨 강도의 경우 화해를 입지 않은 중공슬래브에 비해 34%~40% 감소하는 것으로 나타났으며, 휨 강성의 경우 15%~23% 감소하는 것으로 나타났다. 하중을 재하 한 중공슬래브의 경우 재하하지 않고 가열한 중공슬래브에 비해 약 10%의 강도 저감이 발생하였으며, 휨 강성의 경우 15% 감소한 것으로 나타났다. 이러한 결과는 하중 재하에 따른 휨 균열에 의해 슬래브의 하부 주인장 철근의 온도가 비재하 실험체에 비해 높아지며, 하부철근 피복의 박리현상이 가속화되기 때문인 것으로 판단된다.

제지 슬러지-목재 파티클 혼합보드의 내화성과 기계적 성질 (Fire Retardancy and Mechanical Properties of Paper Sludge-Wood Particle Mixed Board)

  • 손정일;이필우
    • Journal of the Korean Wood Science and Technology
    • /
    • 제22권1호
    • /
    • pp.54-65
    • /
    • 1994
  • This research carried out to investigate the effects of inorganic materials in paper sludge on the thermal degradation and of paper sludge addition on physical and mechanical properties of paper sludge-wood particle mixed boards in comparison with unmodified particleboards. Also these unmodified particleboards and paper sludge-wood particle mixed boards were soaked in aqueous solutions of fire-retardant chemicals(diammonium phosphate and zinc chloride), and their fire retardancy were tested by oxygen index method and ISO ignition test to determine the feasibility of paper sludge, industrial waste, as a recyclable resource in fabrication of fire-resisting panels for building material. Since the redrying of fire-retardant treated particleboards and paper sludge-wood particle mixed boards were made by press drying method, this process was a simple and effective method. On the other hand, flexural bending strength and internal bonding strength were also analysed to evaluate mechanical properties through standard method.

  • PDF

환기부족 구획화재에 대한 FDS 해석 및 검증 (FDS Simulation and Validation on the Under-Ventilated Compartment Fires)

  • 고권현;김성찬;;유홍선
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.103-109
    • /
    • 2009
  • 본 연구에서는 환기부족 조건의 구획화재에 대하여 FDS(Ver. 5.2)를 이용하여 수치해석을 수행하였고 열적 특성 및 연소 가스 생성 특성에 대한 예측성능을 평가하였다. ISO-9705 표준화재실의 2/5 크기 모형에 대한 메탄 및 헵탄, 톨루엔 화재를 모사하였으며 고온 상층부의 온도, 연소가스 농도 등에 대하여 기존의 실험 결과와 비교하였다. 실험결과와의 비교를 통해 FDS가 천정의 온도와 과환기 조건의 혼합분율의 예측에 있어서 좋은 성능을 보임을 확인할 수 있었다. 그러나 화재 크기에 비해 산소의 유입량이 충분치 않은 환기부족 조건에서는 일산화탄소 및 그을름의 발생량을 실험값에 비해 크게 하향 예측하였다.