• 제목/요약/키워드: ISO Standard Fire

검색결과 110건 처리시간 0.022초

국제 표준화 기구의 내화공학설계 연구동향 (Research Trends on Fire Engineering Design of ISO)

  • 권인규
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.73-75
    • /
    • 2008
  • Fire engineering design method based on structural performance of buildings has been developed through all of the worlds since the early 1960's. But recently the worlds have been changed rapidly in aspects of global community and mutural free trade circumstances. Therefore the concepts of fire design on structural performance need to harmonize among countries that have their own unique regulations and ISO TC 92 and SC 4 have worked in order to make the united international standard.

  • PDF

건축물 내화성능평가 표준화 로드맵 개발 (Development of Road-Map on Evaluation of Fire Resistance Performance)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.50-58
    • /
    • 2009
  • 건축물 화재로 인하여 매년 수많은 인명과 재산 그리고 환경적 피해가 발생되고 있으며, 이의 최소화를 위하여 각 국가별로 분야별 화재안전 전략을 개발하고 있다. 건축물 화재안전의 글로벌적 전략 개발은 국제표준화기구(ISO)를 중심으로 이루어지고 있으며, 본 논문에서는 국제표준화기구에서 이루어지고 있는 화재안전 전략의 현황과 기술개발 동향 및 국내의 대응방안 분석 등을 통하여 국내의 건축물 내화성능평가 표준화 로드맵을 제시하고자 한다.

ISO 13784-1 시험 방법에 의한 국제 상호비교 평가 분석 (Analysis on International Round Robin Test's Result by ISO 13784-1 Standard)

  • 박계원;정재군
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.201-204
    • /
    • 2011
  • ISO 13784-1 sandwich panel tests were conducted by FILK, KICT in Korea, SP in Sweden and CSIRO in Australia. Sandwich panels composed of steel sheets, EPS and glass wool supplied by FILK were tested. Mainly heat release rate was compared and equality of distribution also analyzed on the point of statistical view based on ISO.

  • PDF

FDS 열분해 모델을 이용한 콘칼로리미터(ISO 5660) 화재 시뮬레이션 (Fire Simulation by Pyrolysis Method of FDS for the Small Cone Calorimeter (ISO 5660))

  • 양성진;장정훈;강찬용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.206-212
    • /
    • 2009
  • Chemical behaviors of each surface material for interior facilities affect to fire initiation and growth in general fire situation. These chemical behaviors were characterized by thermal properties (Heat release rate, Pyrolysis rate, specific heat, etc) which could be derived from experimental test. Especially, Heat release rate which indicates aspect of fire size is one of the most important property to asses fire hazard and protection needs. The cone calorimeter test (ISO 5660) has recently assumed to a dominant role in bench scale fire testing to obtain the Heat release rate of materials. This value could be calculated by the 'Oxygen Consumption Method' under various producing irradiances to each surface of materials. In this study, Process of the cone calorimeter test was simulated by Pyrolysis model of FDS (Fire Dynamics Simulator by NIST) base on the ISO 5660 international standard. Then, we could estimate the simulation method of FDS in case of single materials through the comparative study with test results.

  • PDF

지하주차장의 내화성능 평가를 위한 차량연소실험 (The combustion test of assuming in parking space for fire resistance)

  • 강승구;김동준;이재영;原田和典;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.48-50
    • /
    • 2013
  • In this study, Car fire for test using ISO 9705 10MW Large Scale Calorimeter. Especially, study on the underground parking for the fire resistance performance. The underground parking lot of the fire resistance regulations in according to with the standard heating curve in Korea. Because of this burning car through experiments to the propose a new heating curve.

  • PDF

iTECH 합성보의 내화성능에 대한 실험연구 (Experimental Study on the Fire Resistance of the iTECH Composite Beam)

  • 이승재;강성덕;최승관;김명한;김상대
    • 한국강구조학회 논문집
    • /
    • 제18권5호
    • /
    • pp.643-654
    • /
    • 2006
  • 본 연구에서는 iTECH 합성보 실험체에 대한 온도와 변형에 대한 내화성능을 ISO834 표준화재와 BS476-20 및 KSF2257 기준에 근거하여 평가하였다. 국내외적으로 복합구조의 내화성능을 규명하기 위한 연구는 지극히 미흡한 실정이며, 따라서 본 연구에서는 iTECH 합성보의 내화성능을 평가하기 위해 1.5m의 슬래브를 포함한 4..7m의 스팬길이에 대하여 실험을 수행하였다. 변수는 실험체의 단면크기, 피복재 보강방법과 보강두께, 그리고 하중비로 하여 내화실험을 수행하였다.

위험관리정보 - 소화기의 선택과 배치

  • 유호정
    • 방재와보험
    • /
    • 통권106호
    • /
    • pp.59-63
    • /
    • 2005
  • 이 글에서는 ISO 11602-1, Fire Protection - Portable and Wheeled Fire Extinguishers - part 1 : Selection and installation(2000년판)과 NFPA 10, Standard for Portable Fire Extinguishers(2003년판)에 설명된 소화기 선택과 배치에 대한 개괄을 한다.

  • PDF

ISO 9705 - Full-scale Room Test 시험방법을 이용한 샌드위치 패널의 화재 특성 연구 (A Study on the Fire Characteristics of Sandwich Panels by ISO 9705 - Full-scale Room Test)

  • 권오상;유용호;김흥열;이정일
    • 한국화재소방학회논문지
    • /
    • 제23권6호
    • /
    • pp.39-45
    • /
    • 2009
  • 본 연구에서는 샌드위치패널의 종합적인 화재특성을 파악하기 위하여 스티로폼, 난연 스티로폼, 우레탄폼, 난연 우레탄폼, 그라스울 샌드위치패널에 대해 국제 화재 시험 규격인 ISO 9705 시험(Full-scale room test)을 실시하였다. 이를 바탕으로 EN 13501-1 및 Eurefic Research Program에서 제시하고 있는 분류기준에 적용하여 샌드위치패널의 종합적인 화재특성을 분석하였다. 그 결과 그라스울 샌드위치 패널은 A class, 난연 우레탄폼과 난연 스티로폼 샌드위치 패널은 B class로 나타났다. 플래시오버가 발생한 스티로폼, 우레탄폼 샌드위치 패널은 E class 로 나타났다.

콘칼로리미터 연소가스 FT-IR 분석을 위한 국제표준 초안의 비교시험 결과분석 (Results of a Round-Robin Test for the Draft International Standard on FT-IR Gas Analysis of Fire Effluents from a Cone Calorimeter)

  • 최정민;박계원;정재군
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.1-8
    • /
    • 2019
  • ISO TC 92에서는 콘칼로리미터의 연소가스를 FT-IR 방식의 가스분석기로 분석하기 위한 표준을 개발하고 있다. 2018년에는 표준 초안(WD 21397)의 절차에 따라 6개 기관이 참여하여 표준 초안의 반복성 및 재현성을 평가하였다. 시험대상 시료는 polymethyl methacrylate (PMMA), 경질 폴리우레탄 보드 및 PVC 장판이었고 콘칼로리미터 시험결과 중 착화시간(s), 최대 열방출률(kW·m-2), 총 방출열량(MJ·m-2) 및 유효연소열(MJ·m-2·kg-1)을, 그리고 FT-IR 가스분석결과 중 독성가스의 최대 농도(µL·L-1), 가스 발생량(g) 및 가스 수율(g·g-1)을 ISO 5725-2에 따라 통계 분석하여 정밀도를 평가하였다. 이상치(outlier)는 발견되지 않았으며 콘칼로리미터 시험의 반복성(sr/m)은 1.5%, 재현성(sR/m)은 9.8%로 나타났고 FT-IR 가스분석의 반복성은 12.9%, 재현성은 27.9%로 나타났다.