• Title/Summary/Keyword: IS-801

Search Result 514, Processing Time 0.04 seconds

Clinical Value of a Desktop Spirometer (HI-801) for Spirometry Screening (선별 검사를 위한 탁상용 폐활량기 (HI-801)의 임상적 유용성에 관한 고찰)

  • Choi, Hye Sook;Choi, Cheon Woong;Park, Myung Jae;Kang, Hong Mo;Yoo, Hong Ji
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.4
    • /
    • pp.276-283
    • /
    • 2007
  • Background: A national health care initiative recommends routine spirometry screening of all smokers over age 45 or patients with respiratory symptoms. In response to the recommendation, new, simple, and inexpensive desktop spirometers for the purpose of promoting widespread spirometric screening were marketed. The performance of these spirometers was evaluated in vivo testing with healthy subjects. However, the clinical setting allows spirometric assessment of various pathologic combinations of flow and volume. Objective: The aim of this study was to compare the accuracy of a desktop spirometer to a standard laboratory spirometer, in a clinical setting with pathologic pulmonary function. Method: In a health check-up center, where screening pulmonary funct test was performed using the HI-801 spirometer. Subjects who revealed the ventilation defect in screening spirometry, performed the spirometry again using the standard Vmax spectra 22d spirometer in a tertiary care hospital pulmonary function laboratory. Pulmonary function test with both spirometer was performed according to the guidelines of the American Thoracic Society. Results: 109 patients were enrolled. Pulmonary function measurements (FVC, $FEV_1$, PEFR, FEF25%-75%) from the HI-801 correlated closely (r=0.94, 0.93, 0.81, 0.84, respectively) with those performed with the Vmax spectra 22d and showed the good limits of agreement and differences between the 2 devices; FVC +0.35 L, $FEV_1$ +0.16 L, PEFR +1.85 L/s, FEF25%-75%-0.13 L/s. With the exception of $FEV_1$, FEF25%-75%, these differences were significant(p<0.05) but small. Conclusion: The HI-801 spirometer is comparable to the standard laboratory spirometer, Vmax spectra 22d, with high accurary for $FEV_1$ and FVC and acceptable differences for clinical use.

Effects of Pilocarpine and Kainic Acid on EEG and Behavior Activity in Freely Behaving Rats

  • Choi, Byung-Ju;Cho, Jin-Hwa;Lee, Maangee-G.
    • Biomolecules & Therapeutics
    • /
    • v.4 no.2
    • /
    • pp.167-173
    • /
    • 1996
  • This study was undertaken to evaluate a behavior-electroencephalogram (EEG) pattern relationship in pilocarpine- and kainic acid-induced convulsions of rats. Also we intended to examine the effect of a noncompetitive N-methyl-D-aspartate (NMDA) receptor antagonist, MK-801, and diazepam on the pilocarpine-induced behavioral and electrical seizures in rats. The electrical activities at frontal and hippocampal areas and behavior activities were measured in freely moving rats. At the beginning of the experiments, the rats displayed an exploratory behavior. This awake and moving phase with a low amplitude, irregular, 4-10 Hz wave was followed by a still phase. Pilocarpine (400 mg/kg, i.p.) and kainic acid (0.5 mg/kg, i.c.v.) induced tonic and clonic seizures. The pilocarpine-induced change in electrical activities exhibited a weak correlation with behavioral convulsion at all stages. The amplitude and duration of the electrical response were not linear with the degree of behavioral score. An application of MK-801 (dizocilpine, 7.5 mg/kg) did not affect the amplitudes of the convulsant-induced electrical activities, though the same dose of this drug caused the deformation of the electrical pattern. There was no effect of MK-801 on the behavioral and electrical activities as expected. Diazepam (1 mg/kg) did not affect the amplitude of the electrical activities induced by pilocarpine but changed the pattern of these activities. Our study shows that there is no linear relationship between degree of behavior and amplitude of electrical activities of convulsants. This may indicate that the NMDA receptor stimulation can be processed by the neocortical or hippocampal network in a different way between behavioral and electrical activities.

  • PDF

[${^3H}MK-801$ Binding to the Synaptic Membranes of Rat Forebrains: Age-related Regulation by Glutamate, Glycine and Spermine

  • Cho, Jung-Sook;Kong, Jae-Yang
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.2
    • /
    • pp.117-125
    • /
    • 1997
  • The N-methyl-D-aspartate (NMDA) receptor-mediated glutamatergic neurotransmission is involved in synaptic plasticity, developmental processes, learning and memory and many neuropathological disorders including age-related diseases. In the present study, regulation of the NMDA receptor properties by various ligands was investigated using $[^3H]MK-801$ binding studies in the synaptic membranes of young and aged rat forebrains. The binding in the presence of glutamate and glycine increased dramatically with growth between 1 and 6 weeks old, and thereafter declined gradually with aging. Glutamate, glycine or spermine respectively increased the binding with growth. Glutamate maintained the binding during aging, while glycine or spermine significantly decreased the binding in the aged brain. The maximum stimulation by glycine varied depending on the ages of brains. Greater sensitivity to glycine was observed at 1 week and 3 months and the sensitivity was significantly reduced in the aged brain. In contrast, spermine showed similar stimulation patterns in young and aged rats. These results indicated that the functional properties of the NMDA receptor-ion channel complex in young and aged rat forebrains are differentially regulated by agonists, and the reduction of the receptor function with normal aging may be, in some degree, due to the reduction of the receptor sensitivity to glycine.

  • PDF

A study on development of Power Cable countermeasuring EFT IEC801-4 (EFT IEC801-4 대책용 전원케이블의 개발에 관한 연구)

  • 김형근;배대환;민경찬;김동일
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.2
    • /
    • pp.107-113
    • /
    • 1995
  • Since the most of the mal-functions in the industrial equipments controlled by processors have been occured by the Electrical Fast Transient(EFT), the International Electrotechnical Commision(IEC) prepare the dummy signal to test the immunity level of the equipments controlled by processors and recommend it for the measuring. In this paper, the defined dummy EFT signal by IEC are analyzed by the spectrum analyzer in the frequency domain and studied the developed countermeasuring parts. The new developed parts are consist of the feedthrough capacitors ( $C_y$ type ) in the input and materials with high permeaility which was wound or inserted in the second layer of the Power Cable in order to increase Common Mode inductance. And it is compared inserted Permalloy to material with high permeability increasing Common Mode inductance. We could gotten a excellent insertion loss on the wide band against EFT signal. Especially, we confirm that countermeasuring Power Cable have been an excellent dynamic characteristics in computer system above the 3.6Kv. This new parts could be effectively used for industrial, MIL, and medical equipments to reduce a mal-functions on the site. Furthermore, these parts also have a good characteristics for EMI countermeasuring over the 60MHz up to several GHz band, they are also expected to be used for all kind of EMS test with IEC801-2, 3, 5 and 6 on the power distributed line.

  • PDF

Model Updating Using the Closed-loop Natural Frequency (폐루프 공진 주파수를 이용한 모델 개선법)

  • Jung Hunsang;Park Youngjin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.801-810
    • /
    • 2004
  • Parameter modification of a linear finite element model(FEM) based on modal sensitivity matrix is usually performed through an effort to match FEM modal data to experimental ones. However, there are cases where this method can't be applied successfully; lack of reliable modal data and ill-conditioning of the modal sensitivity matrix constitute such cases. In this research, a novel concept of introducing feedback loops to the conventional modal test setup is proposed. This method uses closed-loop natural frequency data for parameter modification to overcome the problems associated with the conventional method based on modal sensitivity matrix. We proposed the whole procedure of parameter modification using the closed-loop natural frequency data including the modal sensitivity modification and controller design method. Proposed controller design method is efficient in changing modes. Numerical simulation of parameter estimation based on time-domain input/output data is provided to demonstrate the estimation performance of the proposed method.

Turbidimetric Measurement for On-line Monitoring of SiO2 Particles

  • Kim, In-Sook;Kim, Yang-Sun;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.801-805
    • /
    • 2004
  • In this work, the fundamental study of on-line monitoring of $SiO_2$ particles in the size range of 40 nm to 725 nm was carried out using turbidimetry. The size of particle was measured using a field emission scanning electron microscope (FE-SEM). The factors affecting on the turbidity were discussed, for example, wavelength, size, and concentration. In order to observe the dependence of turbidity on the wavelength, a turbidimetric system equipped with charged coupled detector (CCD) was built. The shape of the transmitted peak was changed and the peak maximum was shifted to the red when the concentration of particle was increased. This result indicates that the turbidity is related to the wavelength, which corresponds to the characteristic of the Mie extinction coefficient, Q, that is a function of not only particle diameter and refractive index but also wavelength. It is clear that a linear calibration curve for each particle in different size can be obtained at an optimized wavelength.

Equivalent moment of inertia of a truss bridge with steel-concrete composite deck

  • Siekierski, Wojciech
    • Structural Engineering and Mechanics
    • /
    • v.55 no.4
    • /
    • pp.801-813
    • /
    • 2015
  • Flexural stiffness of bridge spans has become even more important parameter since Eurocode 1 introduced for railway bridges the serviceability limit state of resonance. For simply supported bridge spans it relies, in general, on accurate assessment of span moment of inertia that governs span flexural stiffness. The paper presents three methods of estimation of the equivalent moment of inertia for such spans: experimental, analytical and numerical. Test loading of the twin truss bridge spans and test results are presented. Recorded displacements and the method of least squares are used to find an "experimental" moment of inertia. Then it is computed according to the analytical method that accounts for joint action of truss girders and composite deck as well as limited span shear stiffness provided by diagonal bracing. Finally a 3D model of finite element method is created to assess the moment of inertia. Discussion of results is given. The comparative analysis proves efficiency of the analytical method.

Globalization and Consolidation in Maritime Transport and Its Implications for Container Port Business

  • Ryoo Dong-Keun
    • Journal of Navigation and Port Research
    • /
    • v.29 no.9
    • /
    • pp.801-806
    • /
    • 2005
  • The world of container shipping and container terminal business is changing and container ports need to know what the changes are in order to plan how to respond. In particular, the container transport industry has noticed two major developments such as globalization and consolidation. The purpose of this paper is to review the current trend towards globalization and consolidation of container liner shipping and container terminal business. It also investigates the impact of these market developments on container ports and presents its implications for port development, management and operation, and port competition policy. According to the discussion of this paper a greater exercise of market power of container terminal operators will have negative impacts on international trade and national economy, especially port users, including container lines, exporters and importers. An empirical evidence on the exercise of market power is required to develop competition rules on market dominance at a national and international level. This paper suggests 'port coopetition' as a solution for smaller and regional container terminal operators to survive in a competitive business environment.

Characterization of Aldolase from Methanococcus jannaschii by Gas Chromatography

  • NamShin, Jeong-E.;Kim, Mi-Jung;Choi, Ji-Ah;Chun, Keun-Ho
    • BMB Reports
    • /
    • v.40 no.5
    • /
    • pp.801-804
    • /
    • 2007
  • The products of reactions catalyzed by Methanococcus. jannaschii (Mj) aldolase using various substrates were identified by gas chromatography (GC). Although Mj aldolase is considered a fuculose-1-phosphate aldolase based on homology searching after gene sequencing, it has not been proven to be a fuculose-1-phosphate aldolase based on its reaction products. Mj aldolase was found to catalyze reactions between glycoaldehyde or D, L-glyceraldehyde and DHAP (dihydroxyacetone phosphate). Before performing GC the ketoses produced were converted into peracetylated alditol derivatives by sequential reactions, i.e., dephosphorylation, $NaBH_4$ reduction, and acetylation. By comparing the GC data of final products with those of standard alditol samples, it was found that the enzymatic reactions with glycoaldehyde, D-glyceraldehyde, and D, L-glyceraldehyde produced D-ribulose-1-phosphate, D-psicose-1-phosphate, and a mixture of D-psicose and L-tagatose-1-phosphate, respectively. These results provide direct evidence that Mj aldolase is a fuculose-1-phosphate aldolase.

Design and Implementation of Frequency Down Converter for Satellite Communication (위성 통신용 주파수 하향 변환기의 설계 및 제작)

  • Lee, Seung-Dae;Na, Sang-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.801-807
    • /
    • 2012
  • In this paper, design and implementation of frequency down converter based on LC filter technic. Single frequency down converter, designed a low-noise amplifier, mixer, IF amplifier, LC filter was configured. And it is composed of DC block capacitors and RF bypass capacitor. LC filter, replace it with the IC reduced the power and realized low cost. The gain of single down converter is about 10dBm and realized by 18MHz bandwidth at 70MHz band.