Evaluation of Coated Tube CA19-9 IRMA kit (Coated tube를 사용한 CA19-9 측정용 IRMA 시약의 평가)

  • Lee, Hyun-Ju;Jang, Hyun-Young;Shin, Sun-Young;Kim, Hee-Sun;Kim, Tae-Hoon;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.208-211
    • /
    • 2010
  • Purpose: $TFB^{(R)}$ CA19-9 IRMA kit uses beads coated with CA19-9 antibody. However, this mathod can not use automated equipment, and requires a long time test. Recently, CA19-9 IRMA kit developed by $TFB^{(R)}$ is coated with CA19-9 antibody to the polystyrene test tube and reaction at room temperature, and also reduced test time. This study evaluated the performance of a newly developed $TFB^{(R)}$ CA19-9 IRMA kit. Materials and Methods: This study were measured by using 56 patients sample of Boramae Medical Center and Seoul National University Hospital. We evaluated intra-and inter-assay precision, recovery rate, linearity, sensitivity and high dose hook effect of coated tube CA19-9 IRMA kit developed by $TFB^{(R)}$. The values of CA19-9 measured by $TFB^{(R)}$ bead kit were compared with those measured by $TFB^{(R)}$ coated tube kit. Results: ntra-assay coefficients of variation on three different levels were 4.1%, 4.0% and 4.2%. Inter-assay coefficients of variation were 7.6%, 4.3% and 7.8%. Recovery tests on all three different levels showed within $100{\pm}10%$. Linearity was good and sensitivity was 0.3 U/mL. High dose hook effect is not observed. There was strong correlation between bead kit and coated tube kit by $TFB^{(R)}$ CA19-9 IRMA kit. (y=0.9185x-0.953, $R^2$=0.9779) Conclusion: Coated tube CA19-9 IRMA kit developed by $TFB^{(R)}$ showed satisfactory precision, recovery rate, linearity, sensitivity and high dose hook effect.

  • PDF

Basic Evaluation of Analytical Performance and Clinical Utility of Immunoradiometric TSH Assay (면역방사 계수측정법 (Immunoradiometric, Assay)에 의한 혈청 TSH 측정의 기본적 검토 및 임상적 의의)

  • Suh, Kyo-Il;Cho, Bo-Youn;Lee, Hong-Kyu;Koh, Chang-Soon;Min, Hun-Ki;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.143-150
    • /
    • 1987
  • To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit $(Abott^{(R)}\;and\;Daichi^{(R)})$. Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 voluteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intra assay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/l respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU/l. Mean recoveray rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/l and 2.85-30.8 mU/l repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function.

  • PDF

The Evaluation of Domestic Immunoradiometric Assay Kit for Alpha-fetoprotein (Alpha-fetoprotein 측정용 국산 방사면역측정법 시약의 평가)

  • Won, Kyoung-Sook;Ryu, Jin-Sook;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.353-359
    • /
    • 2000
  • Purpose: Although ${\alpha}$-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for ${\alpha}$-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for ${\alpha}$-fetoprotein (Riakey AFP IRMA $CT^R$, Sin-Jin Medics, Seoul, Korea). Materials and Methods: We evaluated intra- and inter-assay precision, recovery rate, parallelism, and sensitivity of serum ${\alpha}$-fetoprotein measurement using Riakey AFP IRMA $CT^R$ kit. The values of ${\alpha}$-fetoprotein measured by Riakey AFP IRMA $CT^R$ kit were compared with those measured by two foreign commercial kits (${\alpha}$-fetoproteina of Radim and ${\alpha}$-feto.riabead of Abbott). Results: Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within $100{\pm}10%$. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of ${\alpha}$-fetoprotein by Riakey AFP IRMA $CT^R$ and that by two foreign commercial kits(r=0.98). Conclusion: The first Korean domestic immunoradiometric kit for ${\alpha}$-fetoprotein, Riakey AFP IRMA $CT^R$, performed well for clinical use.

  • PDF

The Assessment of Ultrasensitive HBsAg kit's Sensitivity level and Performance in Detection of Mutant Forms (Ultra-sensitive HBsAg IRMA 키트의 민감도 및 변이형 검출능 평가)

  • Ha, Dong-Hyuk;Min, Kyung-Sun;Noh, Gyeong-Woon;Kim, Hyun-Ju
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.121-125
    • /
    • 2011
  • Purpose: The DNA-type virus HBV, discovered by D. Dane and others in 1976, is approximately 42nm big and known as the main cause of liver-related diseases around the world. HBsAg has 4 kinds of subtypes including adw, adr, ayw and ayr and besides common antigen factor a, there are d, y, r, w. From the methods of serologically testing HBV, IRMA, EIA and CLIa were developed for testing HBsAg and are being used in examining the surface antigen of HBV. In this study, among the methods for testing HBV, the recently developed RIAKEY Ultrasensitive HBsAg IRMA kit's sensitivity level and performance in detection of mutant forms were measured and compared with CLIA. Materials and methods: Two certified reference materials, which are WHO 1st International Standard 1985(80/549) and WHO 2nd International Standard 2003(00/588. subtype adw2, genotypeA), were used in the examination and the sensitivity level was measured by diluting these materials from 0.08 IU/ml to 0.005 IU/ml. The materials for examining the detection of mutant forms included 9 kinds of subtype 'ad' and one kind of subtype 'ay' purchased from DSI company. Also, with the use of positive and negative samples, they was compared with CLIA. Result: Ultrasensitive HBsAg kit based on IRMA method showed the detection of up to 0.01 IU/ml not only for WHO 1st International Standard 1985(80/549) but also for WHO 2nd International Standard 2003(00/588. subtype adw2, genotypeA) and the sensitivity level was measured as 0.01 IU/ml by WHO standard. In testing the performance for detection of mutant forms, the 9 kinds of subtype 'ad' and one kind of subtype 'ay' mutant materials were detected, demonstrating the capacity of detecting various types of mutant forms. Conclusions: With the clinical importance of sensitivity level and performance in detection of mutant forms increasing in the field of HBsAg diagnosis, the examination of IRMA's effectiveness using RIA method in the aspects of the sensitivity level and performance in detection of mutant forms was carried out and its result is as follows. The sensitivity level was measured as 0.01 IU/ml by WHO standard and it was possible to measure various types of mutant forms with high sensitivity. Thus it is suggested that more speedy and accurate reports could be produced from a nuclear medicine laboratory for clinical practitioners requiring results of various situations.

  • PDF

Analysis of HBeAg and HBV DNA Detection in Hepatitis B Patients Treated with Antiviral Therapy (항 바이러스 치료중인 B형 간염환자에서 HBeAg 및 HBV DNA 검출에 관한 분석)

  • Cheon, Jun Hong;Chae, Hong Ju;Park, Mi Sun;Lim, Soo Yeon;Yoo, Seon Hee;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose Hepatitis B virus (hepatitis B virus, HBV) infection is a worldwide major public health problem and it is known as a major cause of chronic hepatitis, liver cirrhosis and liver cancer. And serologic tests of hepatitis B virus is essential for diagnosing and treating these diseases. In addition, with the development of molecular diagnostics, the detection of HBV DNA in serum diagnoses HBV infection and is recognized as an important indicator for the antiviral agent treatment response assessment. We performed HBeAg assay using Immunoradiometric assay (IRMA) and Chemiluminescent Microparticle Immunoassay (CMIA) in hepatitis B patients treated with antiviral agents. The detection rate of HBV DNA in serum was measured and compared by RT-PCR (Real Time - Polymerase Chain Reaction) method Materials and Methods HBeAg serum examination and HBV DNA quantification test were conducted on 270 hepatitis B patients undergoing anti-virus treatment after diagnosis of hepatitis B virus infection. Two serologic tests (IRMA, CMIA) with different detection principles were applied for the HBeAg serum test. Serum HBV DNA was quantitatively measured by real-time polymerase chain reaction (RT-PCR) using the Abbott m2000 System. Results The detection rate of HBeAg was 24.1% (65/270) for IRMA and 82.2% (222/270) for CMIA. Detection rate of serum HBV DNA by real-time RT-PCR is 29.3% (79/270). The measured amount of serum HBV DNA concentration is $4.8{\times}10^7{\pm}1.9{\times}10^8IU/mL$($mean{\pm}SD$). The minimum value is 16IU/mL, the maximum value is $1.0{\times}10^9IU/mL$, and the reference value for quantitative detection limit is 15IU/mL. The detection rates and concentrations of HBV DNA by group according to the results of HBeAg serological (IRMA, CMIA)tests were as follows. 1) Group I (IRMA negative, CMIA positive, N = 169), HBV DNA detection rate of 17.7% (30/169), $6.8{\times}10^5{\pm}1.9{\times}10^6IU/mL$ 2) Group II (IRMA positive, CMIA positive, N = 53), HBV DNA detection rate 62.3% (33/53), $1.1{\times}10^8{\pm}2.8{\times}10^8IU/mL$ 3) Group III (IRMA negative, CMIA negative, N = 36), HBV DNA detection rate 36.1% (13/36), $3.0{\times}10^5{\pm}1.1{\times}10^6IU/mL$ 4) Group IV(IRMA positive, CMIA negative, N = 12), HBV DNA detection rate 25% (3/12), $1.3{\times}10^3{\pm}1.1{\times}10^3IU/mL$ Conclusion HBeAg detection rate according to the serological test showed a large difference. This difference is considered for a number of reasons such as characteristics of the Ab used for assay kit and epitope, HBV of genotype. Detection rate and the concentration of the group-specific HBV DNA classified serologic results confirmed the high detection rate and the concentration in Group II (IRMA-positive, CMIA positive, N = 53).

Assay of Human Chorionic Gonadotropin in Urine of Athletes and Evaluation of Assay Kit Performance (운동선수들의 뇨 중 Human Chorionic Gonadotropin 분석 및 분석킷트 평가)

  • 최명자;이정란;김명수
    • Biomolecules & Therapeutics
    • /
    • v.10 no.3
    • /
    • pp.186-192
    • /
    • 2002
  • Special attention has been paid to human chorionic gonadotropin (hCG) for athlete doping control because it stimulates the endogenous production of testosterone and epitestosterone without increasing the T/E ratio which is a doping indicator for the exogenous administration of testosterone. Even though the IOC banned the use of hCG, a detection method has not been decided upon since there are a variety of immunoassay kits available on the market. We evaluated three kits in terms of their performance characteristics. The assay value of the control sample varied depending on the kit, resulting in 198 mIU/ml for the MAIA kit, 172mIU/ml for the IRMA kit, and 143 mIU/ml for the MEIA kit. Considering the IOC inter-lab distribution of results(55-312 mIU/ml) using 27 different kits and the mean value (178$\pm$56 mIU/ml), all three kits are within the range of -15.8% - +5.6% of the mean value, which proves them useful for the hCG assay. The MEIA kit resulted in lower hCG values because it detects only intact hCG molecules, in contrast to the other two kits which detect intact hCG and -hCG together. However, it is suitable for screening purposes because of its advantage of being an automated system. When 123 urine samples of athletes were analyzed in 22 batches using this system, the variation of control values fell within $\pm$ 10% of the mean values, and an specimens tested negative with hCG values less than the detection limit of 2 mIU/ml.

Evaluation of Usefulness for $Monototal^{TM}$ in Non Small Cell Lung Cancer (비소세포성폐암 환자의 $Monototal^{TM}$ 유용성 평가)

  • Kim, Dae-Woon;Seo, Hyo-Yeol;Jang, Hyun-Young;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.171-174
    • /
    • 2009
  • Purpose: Cancerous death rate 1 place from 2008 year domestic is the lung cancer. The body count which is caused by in the lung cancer every year is increasing. At this lung cancer is the most non small cell lung cancer. $Monototal^{TM}$ test is short reaction time. it is known as the experiment where the example standard of living is high about non small cell lung cancer. This is the study evaluate usefulness of $Monototal^{TM}$ kit. Materials and Methods: $Monototal^{TM}$ were measured using IRMA kit, using 40 CEA positive patients sample which are diagnosed NSCLC, 15 SCC positive patients sample which are diagnosed NSCLC, 40 Cyfra 21-1 positive sample, 20 negative sample in Seoul national university from March to April, 2009. Results: According to result of the $Monototal^{TM}$ test, which is benignancy rate 87.5% in CEA positive patients sample, 93.3% SCC positive patients sample and 100% Cyfra 21-1 positive sample Conclusions: We recommend that using of $Monototal^{TM}$ parallel with different tumor markers. It was useful that diagnosis and convalescence presumption of Non small cell lung cancer.

  • PDF

Expression of the Epidermal Growth Factor and Tumor Necrosis Factor-$\alpha$ in Lung Cancer (폐암에서 Epidermal growth factor와 Tumor Necrosis Factor-$\alpha$의 발현)

  • 장덕기;이충석;박성달;김송명
    • Journal of Chest Surgery
    • /
    • v.34 no.2
    • /
    • pp.138-147
    • /
    • 2001
  • 배경: 폐암발생에 EGF의 자가 분비는 암의 성장과정에 직, 간접적인 영향을 주고 있으며, TNF-$\alpha$는 면역 반응의 급성체로서 폐암의 발생을 억제하고 이미 발생한 폐암종의 치료에도 이용되고 있는 실정이다. 폐암 조직과 혈장에서 epidermal growth factor(EGF)와 tumor necrosis factor-$\alpha$(TNF-$\alpha$)를 면역 방사선 분석법을 이용하여 정량분석 하여 발현 정도를 분석해보고자 하였다. 대상 및 방법: 폐암환자 20례와 양성종양 및 육아종 환자 4례에 대해서 AJCCS에 의한 조직학적 분류와 TNM 분류에 따라 구분하여 절제수술을 받은 환자를 대상으로 수술전 혈액을 채취하고 수술직후 적출한 표본을 암이 없는 건강하다고 판단되는 대조조직과 폐암조직에서 일정량의 조직을 절취하여 액화질소 내에 실험시까지 급속 냉동보관 하였다. 수술후 혈액을 재 채취하여 혈장을 분리하여 냉동고에 검사시까지 보관하였다. EGF의 정량은 Human Epidermal Growth Factor kit(Amersham Phamacia Biotech, England)를 사용하였으며, TNF-$\alpha$ 정량은 TNF-$\alpha$ IRMA kit(Biosouce, Belgium)을 사용하여 IRMA 방법으로 각각 정량분석하여 표현유무를 연구한 결과 다음과 같은 결론을 얻었다. 결과: 1. 대조조직, 양성종양 및 육아종과 폐암 수술전후의 조직과 혈청 모두에서 EGF와 TNF-$\alpha$가 발현되었다. 2. EGF와 TNF-$\alpha$의 농도는 대조조직과 양성종양(0.11$\pm$0.06 ng/ml, 20,3$\pm$9.08 pg/ml)에 비하여 폐암조직(0.13$\pm$0.05 ng/ml, 34.34$\pm$47.74pg/ml)에서 유의하게 높은 농도가 발현되고 있었다. 3. 폐암중 선암조직에서 특히 TNF-$\alpha$(80.92$\pm$104.08 ng/ml)의 발현이 강하게 나타났다. 4. 혈청내의 EGF와 TNF-$\alpha$의 발현되는 양이 조직내의 양보다도 높았다. EGF는 5.7배정도 TNF는 1.3배정도 강하게 표현되었다. 5. 폐암의 조직학적 종류에 따라서 EGF는 거의 차이가 없었으나 TNF-$\alpha$ 정량치에는 차이가 있었다. 6. TNM stage가 진행함에 따라 EGF는 농도가 증가하였고 TNF-$\alpha$는 오히려 감소하는 반대되는 교차현상이 있었다. 7. 수술직후 EGF는 증가하였으나 TNF-$\alpha$는 오히려 감소하였다. 결론: 결론적으로 저자는 암조직과 대조조직간에 EGF와 TNF-$\alpha$의 표현량의 차이가 있음을 관찰하였으며 또한 조직과 혈청사이에도 표현량에 차이가 있으며 조직보다도 오히려 혈청내의 농도가 높다는 사실을 관찰하였다. EFG와 TNF-$\alpha$는 정상조직이나 양성조직과 폐암조직 모두에서 분비작용되는 cytokines으로 세포기능에 따라 다양하게 표현이 되며 계속적인 연구로서 밝혀야만 할 과제라고 판단된다.

  • PDF

Establishment of Reference Intervals of Osteocalcin according to Age in Women for Health Promotion Center (건강검진이 의뢰된 여성의 연령에 따른 Osteocalcin의 참고범위 설정)

  • Kang, Ji-Soon;Yoo, Byoung-Joo;Oh, Jung-Eun;Kim, Geon-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.104-111
    • /
    • 2009
  • Purpose: Osteocalcin is also known as the bone gamma-carboxyglutamic acid (Gla) protein (BGP), is noncollagenous bone protein synthesized by osteoblasts. Serum concentrations of Osteocalcin have been used as a biochemical marker of bone turnover. The reference intervals of Osteocalcin is categorized by kit corporation according to the age. However, each laboratory should establish its own reference intervals. In this study, the variation in the serum Osteocalcin level were used to find actual standard age-specific Osteocalcin reference intervals. Materials and Methods: We have selected 864 healthy females aged 20~80 years who visited a health promotion center between Aug. 2007 and Sep. 2008. The Osteocalcin IRMA Kit (OSTEO-RIACT, CIS Bio international, Gif-sur-Yvette, France) was used for the quantification. Each results were analyzed with the SPSS 12.0 statistical software. Results: The analyzed reference intervals of Osteocalcin by using Hoffmann method are from 8.8~39.4 ng/mL to 6.3~28.8 ng/mL for the case of the age from 20 to 30, from 7.7~31.9 ng/mL to 5.9~17.4 ng/mL for the case of the age from 31 to 40, and from 8.0~36.0 ng/mL to 5.5~20.1 ng/mL for the case of the age from 41 to 50, and from 8.0~50.5 ng/mL to 6.7~27.0 ng/mL for the case of the age from 51 to 60, and from 12.9~55.9 ng/mL to 7.5~27.5 ng/mL for the case of the age from 61 to 80. Reference intervals of Osteocalcin were not in agreement with those recommended by the manufacturers. Conclusions: Osteocalcin is used as an indication of metabolic bone diseases. So in our study we wanted to provide reference intervals of Osteocalcin that can be useful to a clinical decisions. Also, previous reference intervals should not be re-used and new intervals should be set by continuous analyzing.

  • PDF