• Title/Summary/Keyword: IR radiation

Search Result 361, Processing Time 0.024 seconds

The Preparation of a Thermally Responsive Surface by Ion Beam-induced Graft Polymerization

  • Jung, Chang-Hee;Kim, Wan-Joong;Jung, Chan-Hee;Hwang, In-Tae;Choi, Jae-Hak
    • Journal of Radiation Industry
    • /
    • v.6 no.4
    • /
    • pp.317-322
    • /
    • 2012
  • In this study, the preparation of a temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm)-grafted surface was performed using an eco-friendly and biocompatible ion beam-induced surface graft polymerization. The surface of a perfluoroalkoxy (PFA) film was activated by ion implantation and N-isopropylacrylamide (NIPAAm) was then graft polymerized selectively onto the activated regions of the PFA surfaces. Based on the results of the peroxide concentration and grafting degree measurements, the amount of the peroxide groups formed on the implanted surface was dependant on the fluence, which affected the grafting degree. The results of the FT-IR-ATR, XPS, and SEM confirmed that the NIPAAm was successfully grafted onto the implanted PFA. Moreover, the contact angle measurement at different temperatures revealed that the surface of the PNIPAAm-grafted PFA film was temperature-responsive.

A Study on Filter and Lamp of Blocking Fading Wavelength with Use of the Deposition (증착법을 이용한 퇴색파장 차단 필터 및 램프에 관한 연구)

  • Lim, Jong-Min;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.47-56
    • /
    • 2010
  • For a human being's smooth activity, the clean air and comfortable lighting environment are needed. The suitable lighting environment is obtained generally by making it available for being formed the bright situation easy for seeing object and the visually comfortable atmosphere. In this way, even the lighting environment was changed along with economic development. Even a light source was diversified. Thus, several kinds of new light sources such as LED, OLED, PLS, and CNT came to appear. Halogen lamp, which has low efficiency due to high color rendering among lamps of being used now, is being much used yet. However, owing to radiation of UV and IR, there are many limitations to the subject in general exhibition lighting, museum, and art museum. Accordingly, a research was performed on filter that is blocked UV and IR at the same time, by using halogen lamp that is excellent in color rendering and in life.

γ-Irradiation Induced Adhesion Molecules are Reduced by Vitamin C in Human Endothelial Cells

  • Son, Eun-Wha;Kim, Byung-Oh;Pyo, Suh-Kneung
    • Biomolecules & Therapeutics
    • /
    • v.12 no.3
    • /
    • pp.145-150
    • /
    • 2004
  • Inflammation is a frequent radiation-induced reaction following therapeutic irradiation. Treatment of human umbilical endothelial cells (HUVEC) with ${\gamma}$-irradiation (${\gamma}$IR) induces the expression of adhesion proteins such as intercellular adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1), and E-selectin. Since the upregulation of these proteins on endothelial cell Surface has been known to be associated with inflammation, interfering with the expression of adhesion molecules is an important therapeutic target. In the present study, we demonstrate that vitamin C inhibits ${\gamma}$IR induced expression of ICAM-1, VCAM-1, and E-selectin on HUVEC in a dose- and time dependent manner. Vitamin C a1so inhibited the production of Nitric oxide (NO) induced by ${\gamma}$IR. These data suggest that vitamin C has therapeutic potential for the treatment of various inflammatory disorder associated with an increase of endothelial leukocyte adhesion molecules.

Preparation of Pt-Black Absorber by Electroplating (전기도금법에 의한 백금 흑 수광체 제조)

  • Bae, Seong-Ho;Lee, Sang-Man;Lee, Mun-Ho
    • Korean Journal of Crystallography
    • /
    • v.7 no.2
    • /
    • pp.133-146
    • /
    • 1996
  • Morphology and infrared absorbing characteristics of Pt-black prepared by electroplating have been investigated with XRD, SEM, and IR spectrophotometer. The Pt later was coated on Au-coated alumina/glass substrates for 1-5 min at pH 1.0-1.5, where a solution of platinum chloride and lead acetate was used as the electrolyte. At the electrical current density of 20-50 mA/㎠, the Pt-black showed a dendritic growth which was characterized by a "tree" shape. Absorptivity of above 90% at IR radiation of 10 m was observed for the Pt absorbing layer with an area density of ≥1.3mg/㎠.

  • PDF

Research on Measurement of Infrared Thermograpphy under High Temperature Condition (고온 환경에서의 적외선 열화상 측정에 관한 연구)

  • Jun-Sik Lee;Jae-Wook Jeon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2024
  • This study conducted a measurement method of high temeprature conditions using infrared termography. All objects emit infrared light, and this emissivity has a significant impact on the temperature measurements of infrared thermal imaging (IR) cameras. In order to measure the temperature more accurately with the IR camera, correction equations were derived by measuring the emissivity according to the temperature change of combustible metals in a high-temperature environment. Two combustible metals, Mg and Al, were used to measure emissivity with changing temperature. Each metal was heated, the emissivity was measured by comparing the temperature with IR camera and thermocouples so that the correlation between temperature and emissivity could be anslyzed. As a result of the experiment, the emissivity of the metals increases as the temperature increased. This can be interpreted as a result of increased radiation emission as the thermal movement of internal metal molecules increased.

Evaluating The Radioprotective Effect of Avocado Peel Extracts upon Rat Exposed to 6 MV X-Ray (6 MV X-ray에 피폭된 흰쥐에 대한 아보카도 껍질 추출물의 방사선방호효과 평가)

  • Kim, Jang-Oh;Shin, Ji-Hye;Jung, Do-Young;Jeon, Chan-hee;Lee, Ji-Eun;Lee, Yoon-Ji;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.553-561
    • /
    • 2020
  • In this study aims to investigate the radiation protection effect of avocado peel extracts on the Sprague-Dawely rats. 52 male rats were randomly classified into 4 groups. NC Group was a normal control group, PA Group was a group injected avocado peel extracts, IR Group was irradiated group, and lastly PA+IR Group was set as an irradiated group after injected of avocado peel extracts. Avocado peel extract was administered orally at 200 mg/kg once a day for 14 days before irradiation, and the radiation dose was systemically irradiated with 6 MV X-ray of 7 Gy. On the 4 and 21 days after irradiation, the experimental animals were sacrificed to evaluate the change in blood cell composition, spleen index, and histopathological evaluation of the liver and small intestine. As a result, the PA+IR Group showed a significantly greater recovery of lymphocytes(p<0.01), red blood cells(p<0.01), and platelets(p<0.05) than the IR Group. It was also confirmed that the activation of Superoxide Dismutase(SOD) was further increased. Histopathologically, observed that nuclei aggregation and cytoplasmic expansion were slightly reduced in the PA+IR Group in the liver. and the damage was significantly reduce(p<0.01) in the change of villi length due to damage to the small intestine cells. Based on the above results, avocado peel extract can be expected to act as a radiation protection agent that can reduce damage to blood cells and major organs caused by irradiation.

Evaluation of Spatial Dose Rate in Working Environment during Non-Destructive Testing using Radioactive Isotopes (방사성동위원소를 이용한 비파괴 검사 시 작업환경 내 공간선량률 평가)

  • Cho, Yong-In;Kim, Jung-Hoon;Bae, Sang-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.373-379
    • /
    • 2022
  • The radiation source used for non-destructive testing have permeability and cause a scattered radiation through collisions of surrounding materials, which causes changes in the surrounding spatial dose. Therefore, this study attempted to evaluate and analyze the distribution of spatial dose by source in the working environment during the non-destructive test using monte carlo simulation. In this study, Using FLUKA, a simulation code, simulates 60Co, 192Ir, and 75Se source used in non-destructive testing, The reliability of the source term was secured by comparing the calculated dose rate with the data of the Health and Physics Association. After that, a non-destructive test in the radiation safety facility(RT-room) was designed to evaluate the spatial dose according to the distance from the source. As a result of the spatial dose evaluation, 75Se source showed the lowest dose distribution in the frontal position and 60Co source showed a dose rate of about 15 times higher than that of 75Se and about 2 times higher than that of 192Ir. In addition, the spatial dose according to the distance tends to decrease according to the distance inverse square law as the distance from the source increases. Exceptionally, 60Co, 192Ir, and 75Se sources confirmed a slight increase within 2 m of position. Based on the results of this study, it is believed that it will be used as supplementary data for safety management of workers in radiation safety facilities during non-destructive testing using radioactive isotopes.

A Study on the Infrared Radiation Properties for SiO$_2$/Fe$_2$O$_3$Films Coated on aluminum (알루미늄에 코팅된 SiO$_2$/Fe$_2$O$_3$막의 적외선 복사특성에 관한 연구)

  • 강병철;김기호
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.5
    • /
    • pp.406-412
    • /
    • 2003
  • FT-IR and thermography were used to investigate the infrared radiation characteristic of SiO$_2$ film and SiO$_2$/Fe$_2$O$_3$film coated on aluminum. Through FT-TR spectrum, SiO$_2$film showed high infrared absorption in accordance with the stretching vibration of Si-O-Si, and as$ Fe_2$$O_3$was mixed additional absorption band appeared resulting from the stretching vibration of Fe-O at $590cm^{-1}$ and the bond of Si-O-Fe at $900 cm^{-1}$ The two kinds of film measured by the integration method and the reflective method coincided with each other in the wavelength area of infrared absorption and radiation, and corresponded well with Kirchhoff's law as the infrared emissivity is high in wavelength where infrared absorption rate is high. The emissivity of $SiO_2$ film was 0.65 and that of $SiO_2$/Fe$_2$$O_3$film was 0.77, so the addition of$ Fe_2$$O_3$ raised the infrared emissivity by approximately 13%.$ SiO_2$$Fe_2$$O_3$ film is efficient as an infrared radiator at below $100^{\circ}C$. The temperature of heat radiation after 7 minutes was 117$^{\circ}C$ in aluminum plate and $155^{\circ}C$ in $SiO_2$$Fe_2$$O_3$ film, $38^{\circ}C$ higher than the former.

A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources (고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰)

  • Baek, Tae-Seong;Lee, Seung-Wook;Na, Soo-Kyong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose: To compare of the accuracy among various measurement procedures of HDR Brachytherapy, and to evaluate the clinical suitability and usefulness of alternative PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom without any additional cost due to the purchase of measuring apparatus. Materials and Methods: We made a comparative study on three types of measuring systems: well type chamber, source calibration jig, and PMMA plate phantom. Farmer type chamber was used for source calibration jig method and PMMA plate phantom method. Measurement was done 5 times each in comparison with the measurement values from manufacturer. Measurement results from experiment were compared with that from the manufacturer which is offered with the source whenever a source is substituted by a new one and evaluate the accuracy of source activity. Results: As a consequence of Ir-192 source measurement using well type chamber, source calibration jig and PMMA plate phantom, RMS (Root Mean Square) values for the relative error are 0.6%, 1.57%, 2.1%, respectively, compared with the data from manufacturer. And the mean errors with standard deviation are given $-0.2{\pm}0.5%$, $0.97{\pm}1.23%$, $-0.89{\pm}1.87%$ respectively. Conclusion: From the results shown by the three types of measurement system (well type chamber, source calibration jig, and PMMA plate phantom), the measurement with well type chamber produced the best accuracy. It turns out that we can also use the alternative system of PMMA plate phantom clinically without purchasing any additional particular apparatus since the system does not exceed the recommendation of AAPM (American Association of Physicists in Medicine), which requires the error range of within ${\pm}5%$.

  • PDF

Fabrication and characterization of plastic fiber-optic radiation sensor tips using inorganic scintillator material (무기 섬광체를 이용한 플라스틱 광섬유 방사선 센서부 제작 및 특성평가)

  • Hwang, Young-Muk;Cho, Dong-Hyun;Lee, Bong-Soo;Cho, Hyo-Sung;Kim, Sin
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.244-249
    • /
    • 2005
  • In this study, radiation sensor tips are fabricated for remote sensing of X or gamma ray with inorganic scintillators and plastic optical fiber. The visible range of light from the inorganic scintillator that is generated by radiation source is guided by the plastic optical fiber and is measured by optical detector and power-meter. Two kinds of sensor tips are designed and fabricated such as film type and powder type. Many kinds of inorganic scintillators are used to fabricate both sensor tips, and the different wavelength of emitting lights from them are measured to determine the optimal inorganic scintillator which has maximum light output. As a radiation source X-ray generator and Ir-192 are selected to test a performance of sensor tip. It is expected that the fiber-optic radiation sensor is widely used in nuclear industry and medical applications due to its special characteristics such as good flexibility, easy in processing, long lengths and no interference to electro magnetic field.