• Title/Summary/Keyword: IR drop

Search Result 74, Processing Time 0.035 seconds

Electrochemical Characteristics of EDLC with various Organic Electrolytes (유기전해질에 따른 EDLC의 전기화학적 특성)

  • Yang Chun-Mo;Lee J.K.;Cho W.I.;Cho B.W.;Rim Byung-O
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.3
    • /
    • pp.113-117
    • /
    • 2001
  • Specific capacitance and charge-discharge rate of EDLC using activated carbon electrode were affected by the compositions of electrolytes, the conditions of charge-discharge and physical properties of activated carbon materials. The activated carbon electrode was prepared by dip coating method. Charge-discharge test and electrochemical experiments were carried out for various kinds of organic electrolytes. Effects of charge and discharge current density on the specific capacitance were studied. Characteristics of leakage current, self-discharge and time-voltage curves in optimum conditions of organic electrolytes were compared with conventional $1M-Et_4NBF_4/PC$ electrolyte. The EDLC using MSP-20(specific surface area: $2000m^2/g$) electrode and $1M-LiPF_6/PC-DEC(1:1)$ was exhibited th highest specific capacitance of 130F/g and low polarization resistances. The EDLC using MSP-20 electrode at $1M-LiPF_6/PC-DEC(1:1)$ was small leak current of 0.0004A for 15min, long voltage retention of 0.8V after 100h and linear time-voltage curves with small IR-drop.

Prediction of Characteristics for the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners used in the Field (실공간 사용 공기조화기용 열교환기의 공기측 파울링 특성 예측)

  • Ahn, Young-Chull;Jung, Sung-Hak;Hwang, Yu-Jin;Lee, Chang-Gun;Kim, Doo-Hyun;Jung, Seong-Ir;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.563-568
    • /
    • 2007
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performances of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. An empirical modeling equation has been derived from the experimental results using accelerated tests and it showed good predictions of the fouling characteristics of the slitted finned tube heat exchangers. However the modeling equation predicts only the fouling characteristics of new heat exchangers and it can not predicts fouling characteristics obtained from actual field data which contains the effect of hydrophilicity deterioration. Therefore an modified modeling equation is proposed and it shows good predictions of the actual fouling characteristics of finned-tube heat exchangers.

Effect of the Plasma-assisted Patterning of the Organic Layers on the Performance of Organic Light-emitting Diodes

  • Hong, Yong-Taek;Yang, Ji-Hoon;Kwak, Jeong-Hun;Lee, Chang-Hee
    • Journal of Information Display
    • /
    • v.10 no.3
    • /
    • pp.111-116
    • /
    • 2009
  • In this paper, a plasma-assisted patterning method for the organic layers of organic light-emitting diodes (OLEDs) and its effect on the OLED performances are reported. Oxygen plasma was used to etch the organic layers, using the top electrode consisting of lithium fluoride and aluminum as an etching mask. Although the current flow at low voltages increased for the etched OLEDs, there was no significant degradation of the OLED efficiency and lifetime in comparison with the conventional OLEDs. Therefore, this method can be used to reduce the ohmic voltage drop along the common top electrodes by connecting the top electrode with highly conductive bus lines after the common organic layers on the bus lines are etched by plasma. To further analyze the current increase at low voltages, the plasma patterning effect on the OLED performance was investigated by changing the device sizes, especially in one direction, and by changing the etching depth in the vertical direction of the device. It was found that the current flow increase at low voltages was not proportional to the device sizes, indicating that the current flow increase does not come from the leakage current along the etched sides. In the etching depth experiment, the current flow at low voltages did not increase when the etching process was stopped in the middle of the hole transport layer. This means that the current flow increase at low voltages is closely related to the modification of the hole injection layer, and thus, to the modification of the interface between the hole injection layer and the bottom electrode.

A Study on the Crevice Corrosion for Ferritic Stainless Steel (페라이트 스테인리스강의 틈부식에 대한 연구)

  • Baik Shin-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.10 no.1 s.20
    • /
    • pp.51-54
    • /
    • 2004
  • In recently days, the breed fish farm is increased in the beach side for farming fish. In such a farm, the heater is requested for preventing freezing in cold season. The heating material are requested high corrosion resistance and strength for endurance high corrosive salt and pressure. In case of low corrosion resistance and/or strength, the heating element shall be broke down and eventually make spillage or leaking contaminated salt. In the most cases, crevice corrosion is localized form of corrosion usually associated with a stagnant solution on the micro-environmental level. In this study, the crevice corrosion of Ferritic type 430 stainless steel is investigated. The size of specimen is $15{\times}20{\times}3mmt$. Test solution is 1N H2SO4 + 0.05N NaCl. The artificial crevice gap size is $0.24{\times}3{\times}15mmL$. Crevice corrosion is measured under applied voltage 300mV(SCE) to the external surface. the result of this study showed that 1) the induced time for initiation of crevice is 750seconds, 2) potential is dropped in the crevice from the top of gap opening from -320 to -399mV. The result confirmed that the potential drop(IR mechanism) in the crevice is one of mechanism for crevice corrosion.

  • PDF

Microanalytical Study of Sodium Alginate by Differential Pulse Stripping Voltammetry (시차 펄스 벗김전압전류법을 이용한 Sodium Alginate의 미량분석 연구)

  • Kang, Dae-Joon;Yun, Young-Ja
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.2
    • /
    • pp.109-114
    • /
    • 2000
  • In this study, the optimum analytical condition of Differential pulse Voltammetry for the polymeric Sodium Alginate was studied and its reduction funtional groups were confirmed using Cyclic Vol-tammetry and IR spectroscopy. Optimum conditions were as followed; mercury drop size : medium size, accumulation time : 60sec, accumulation potential : -0.20V vs Ag/AgCl, scan rate : 100mV/sec, supporting electrolyte : 0.10M $NaClO_4$(pH 6.8). After polymeric Sodium Alginate was hydrolized at $100^{\circ}C$ in acidic condition, the current peaks of oligomer were compared with current peak of polymeric Sodium Alginate. In this optimum condition, calibration curve of polymer Sodium Alginate showed good linearity from 0.50ppm to 4.0ppm where as oligomeric Sodium Alginate showed good linearity from 0.05ppm to 0.24ppm.

  • PDF

Synthesis of Novel Polythiol for Plastic Optical Lens and its Ophthalmic Lens

  • Jang, Dong-Gyu;Roh, Soo-Gyun;Kim, Jong-Hyo;Jin, Wen-Yi;Seo, Jin-Moo;Kwon, Myeong-Ja;Lee, Soo-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2227-2232
    • /
    • 2009
  • Novel polythiol materials of urethane lens series for plastic optical lens were synthesized from polyol materials via thioisouronium of thiourea with c-HCl in refluxing aqueous solution, in which polythiol material was carried out from hydrolysis of thioisouronium by ammonia water. Their structure properties were identified by EA, EI-MS, FT-IR, $^1H\;and\;^{13}C$ NMR spectroscopies and TGA. Their ophthalmic lenses as polythiourethane material were prepared by thermal curing to an injected glass mold using the evenly solutions of diisocyanates series (TDI, XDI, HDI or IPDI) with polythiols. Polythiourethane shows that the strong stretching mode for SH group of polythiol disappeared in FT-IR spectra after thermosetting polymerization. Thermal deformation starting temperature of ophthalmic lenses was determined by TMA. Ophthalmic lenses made from characteristic polythiol and diisocyanate series have transparency, colorless and good impact strength, in which thermal resistance and impact strength of ophthalmic lenses were influenced by diisocyanate series. Physical properties of ophthalmic lens have contrast thermal resistance with impact strength. The property of thermal resistance and impact strength for respective ophthalmic lenses was examined by TMA and drop ball test.

Preparation and Characterization of PTMSP/PDMS-zeolite Composite Membranes for Gas Separation (기체분리를 위한 PTMSP/PDMS-zeolite 복합막의 제조 및 특성)

  • Kim, Na-Eun;Kang, Tae-Beom;Hong, Se Lyung
    • Membrane Journal
    • /
    • v.22 no.5
    • /
    • pp.342-351
    • /
    • 2012
  • In this study, PTMSP[poly(1-trimethylsilyl-1-propyne)]/PDMS[poly(dimethylsioxane)]-NaY zeolite and PTMSP/PDMS-NaA zeolite composite membranes were made to incorporate zeolite into PTMSP/PDMS graft copolymer in order to improve the selectivity and thermal stability, the drop of permeability by physical aging effect during long period of time for the PTMSP membrane. To investigate the physico-chemical characteristics of composite membranes, the analytical methods such as FT-IR, $^1H$-NMR, TGA, SEM, and GPC have been utilized. The gas permeability and selectivity properties of $H_2$ and $N_2$ were evaluated. The permeability of the PTMSP/PDMS-NaY zeolite and PTMSP/PDMS-NaA zeolite composite membranes than PTMSP/PDMS graft copolymer membrane increased, increased as zeolite content increased. On the contrary, the selectivity ($H_2/N_2$) of the composite membranes decreased as zeolite content increased. PTMSP/PDMS-NaA zeolite composite membrane showed better permeability and separation factor than PTMSP/PDMS-NaY zeolite composite membrane.

The effect of calcium concentration and temperature on the gelation of Aigeok Polysaccharide (Aigeok polysaccharide의 겔화에 미치는 칼슘농도와 온도의 효과)

  • Lee, Hyang-Aee;Kim, Keyng-Yi
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.7-11
    • /
    • 2001
  • The influence of temperature and calcium concentration on the gelation kinetics of purified Aigeok system has been investigated by small deformation oscillatory measurement. DE(degree of esterification) of the present sample was indicated of low methoxyl Aigeok polysaccharide by FT-IR. The calcium induced gelation of Aigeok has been studied. Both moduli reached the saturation value during the period of experiments. Rate constant increased with increasing calcium concentration, however above 4.08 mM calcium chloride caused a sudden drop in gel strength. The experimental result that the decrease in gel strength at high calcium concentration was seems to be phase separation or competitive inhibition between calcium ions. The storage and loss shear moduli decreased with increasing temperature. The rate constant of Aigeok system remarkably dropped above $35^{\circ}C$. Thus hydrogen bonding is prior to hydrophobic interaction for Aigeok molecule.

  • PDF

COMPLIANCE STUDY OF METHYLPHENIDATE IR IN THE TREATMENT OF ADHD (주의력결핍과잉행동장애 치료 약물 Methylphenidate IR의 순응도 연구)

  • Hwang, Jun-Wan;Cho, Soo-Churl;Kim, Boong-Nyun
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.15 no.2
    • /
    • pp.160-167
    • /
    • 2004
  • Objectives : There have been very few studies on the compliance of methylphenidate-immediate releasing form(MPH-IR), which is the most frequently used drug in Korea, in Attention Deficit Hyperactivity Disorder(ADHD). This study was conducted to investigate the compliance rate and the related factors in the one year pharmacotherapy process via OPD for children with ADHD. Method : Total 100 ADHD patients were selected randomly among patients who have been treated with MPH-IR from September in 2002 to December in 2002. All the selected patients were diagnosed with DSM-IV-ADHD criteria and fulfilled the inclusion criteria. In March, 2003(at the time of 6 month treatment), all the patients and parents received the questionnaire for the compliance and satisfaction for MPH-IR treatment. In October 2003(at time of 1 year treatment), we, investigators evaluated the socio-demographic variables, developmental data, medical data, family data, comorbid disorders, treatment variables, and compliance rate. Through these very comprehensive data, The compliance rate at the time of mean 1 year treatment and the related factors were investigated. Result : 1) In the questionnaire for compliance and satisfaction for MPND treatment, the 60% of respondents(parents) reported more than moderate degree of satisfaction in the effectiveness of MPND. Their compliance rate for the morning prescription was 81%, but the rate of afternoon prescription was 43%. 2) In the evaluation at the time of 1 year treatment(October 2003), the 38% of parents were dropped out from the OPD treatment. The mean compliance rate for the 1 year treatment was 62%. the 38% of parents were dropped out from the OPD treatment. The mean compliance rate for the 1year treatment was 62%. 3) Compared with the noncompliant group(drop-out group), compliant group showed higher total, verbal and performance IQ scores. In the treatment variables, higher reposponder rate(clinician rating), higher medication dosage and more compliance rate in afternoon prescription were found in the compliant group compared with the noncompliant group. There were no statistical differences in the demographic variables(age, sex, SES, parental education level), medical data, developmental profiles and academic function. Conclusion : To our knowledge, this is the first report about the compliance rate of the MPH-IR treatment for the children with ADHD. The compliance rate at the time of mean 1year treatment was 62%, which was comparable with other studies performed in foreign countries, especially States. In this study, the compliance related factors were IQ score, clinical treatment response, dosage of MPH-IR, and early compliance for the afternoon prescription. These results suggest that clinician plan the strategies for the promotion of the early compliance for the after prescription and enhancement of overall treatment response.

  • PDF

Effects of cyclic mean pressure of helium gas on performance of integral crank driven stirling cryocooler

  • Hong, Yong-Ju;Ko, Junseok;Kim, Hyo-Bong;Park, Seong-Je
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.3
    • /
    • pp.30-34
    • /
    • 2016
  • An integral crank driven Stirling cryocooler is solidly based on concepts of direct IR detector mounting on the cryocooler's cold finger, and the integral construction of the cryocooler and Dewar envelope. Performance factors of the cryocooler depend on operating conditions of the cryocooler such as a cyclic mean pressure of the working fluid, a rotational speed of driving mechanism, a thermal environment, a targeted operation temperature and etc.. At given charging condition of helium gas, the cyclic mean pressure of helium gas in the cryocooler changes with temperatures of the cold end and the environment. In this study, effects of the cyclic mean pressure of helium gas on performances of the Stirling cryocooler were investigated by numerical analyses using the Sage software. The simulation model takes into account thermodynamic losses due to an inefficiency of regenerator, a pressure drop, a shuttle heat transfer and solid conductions. Simulations are performed for the performance variation according to the cyclic mean pressure induced by the temperature of the cold end and the environment. This paper presents P-V works in the compression and expansion space, cooling capacity, contribution of losses in the expansion space.