• Title/Summary/Keyword: IR 신호 검출

Search Result 37, Processing Time 0.023 seconds

Development of Passive Millimeter-wave Security Screening System (수동 밀리미터파 보안 검색 시스템 개발)

  • Yoon, Jin-Seob;Jung, Kyung Kwon;Chae, Yeon-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.138-143
    • /
    • 2016
  • The designed and fabricated millimeter-wave security screening system receives radiation energy from an object and a human body. The imaging system consist of sixteen array antennas, sixteen four-stage LNAs, sixteen detectors, an infrared camera, a CCD camera, reflector, and a focusing lens. This system requires high sensitivity and wide bandwidth to detect the input thermal noise. The LNA module of the system has been measured to have 65.8 dB in average linear gain and 82 GHz~102 GHz in bandwidth to enhance the sensitivity for thermal noise, and to receive it over a wide bandwidth. The detector is used for direct current (DC) output translation of millimeter-wave signals with a zero bias Schottky diode. The lens and front-end of the millimeter-wave sensor are important in the system to detect the input thermal noise signal. The frequency range in the receiving sensitivity of the detectors was 350 to 400 mV/mW at 0 dBm (1 mW) input power. The developed W-band imaging system is effective for detecting and identifying concealed objects such as metal or plastic.

마이크로볼로미터 IR 소자의 응답도 특성의 진공도 의존성 연구

  • Han, Myeong-Su;Han, Seok-Man;Sin, Jae-Cheol;Go, Hang-Ju;Kim, Hyo-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.361-361
    • /
    • 2013
  • 비냉각 적외선 검출소자는 빛이 전혀 없는 환경에서도 사물을 감지하는 열상장비의 핵심소자이다. 마이크로볼로미터 적외선 검출기는 상온에서 동작하며, 온도안정화를 위해 TEC를 장착하여 진공패키지로 조립된다. 패키지는 진공을 유지할 수 있도록 일반적으로 메탈로 제작되며, 단가 감소 및 생산성 증대를 위해 wafer level packaging 방법을 이용한다. 마이크로볼로미터의 특성은 패키지의 진공 변화에 매우 민감하다. 센서의 감도를 증가시키기 위해서는 진공환경을 유지해야 한다. 볼로미터 소자의 특성은 상압에서 열전도는 기판과 멤브레인 사이의 에어갭을 통해 열손실을 야기하므로 센서의 반응도가 현저히 줄어든다. 에어갭이 1 um 정도 되더라도 그 사이에 존재하는 열전도가 가능하므로 진공을 유지하여 열고립 상태를 증대시킬 수 있다. 이에 본 연구에서는 소자의 동작시 압력, 즉 진공도가 볼로미터 소자의 반응도 특성에 미치는 영향을 조사하였다. 마이크로볼로미터 소자는 $2{\times}8$ 어레이 형태로 제작하였으며, metal pad를 각 단위셀에 배치하였으며, 공통전극으로 한 개의 metal pad를 넣어 설계하였다. 흡수체로써 VOx를 사용하였으며, 열 고립구조를 위해 2.5 um 공명 흡수층의 floating 구조로 멤브레인을 형성하였다. 진공패키지는 메탈패키지를 제작하여 볼로미터 칩을 TEC 위에 장착하였으며, 신호의 감지를 위해 가변저항을 매칭시켰다. 반응도는 신호 대 잡음 값을 획득하여 소자에 도달하는 적외선 에너지에 대해 반응하는 값을 계산에 의해 얻어내는 것이다. 픽셀 크기는 $50{\times}50$ um이며, 패키지 조립 공정 후 온도변화에 따른 저항 측정을 통해 TCR 값을 얻었다. 이때 TCR은 약 -2.5%/K으로 나타났다. $2{\times}8$의 4개 단위소자에 대해 측정한 값은 균일하게 TCR 값이 나타났다. 광반응 특성은 볼로미터 단위소자에 대해서 먼저 고진공(5e-6 torr) 하에서 측정하였으며, 반응도는 25,000 V/W의 값을 나타내었고, 탐지도는 약 2e+8 $cmHz_{1/2}$/W로 나타났다. 패키지의 압력 조절을 위해 TMP 및 로터리 펌프를 이용하여 100 torr에서 1e-4 torr의 범위에서 압력조절 밸브를 이용하여 질소가스의 압력으로 진공도를 변화시켰다. 적외선 반응신호는 압력이 증가함에 따라 감소하였으며, 2e-1 torr의 압력에서 신호의 크기가 감소하기 시작하여 5 torr에서 반응도의 1/2 값을 나타냄을 알 수 있었다. 30 torr 이상에서는 신호가 잡음값 과거의 동일하여 신호대 잡음비가 1로 나타남을 알 수 있었다. 또한 진공도 변화에 대해, 흑체온도에 따른 반응도 및 탐지도의 특성을 조사한 결과를 발표한다. 반응도의 증가를 위해 진공도는 진공도는 1e-2 torr 이하의 압력을 유지해야 함을 본 실험을 통해 알 수 있었다.

  • PDF

Detection Property of Red Blood Cell-Magnetic Beads Using Micro Coil-Channeland GMR-SV Device (마이크로 코일-채널과 GMR-SV 소자를 이용한 적혈구-자성비드 검출 특성연구)

  • Park, Ji-Soo;Kim, Nu-Ri;Jung, Hyun-Jun;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • The micro device, coil, and channel for the biosensor integrated with the GMR-SV device based on the antiferromagnetic IrMn layer was fabricated by the light lithography process. When RBCs coupled with several magnetic beads with a diameter of $1{\mu}m$ passed on the micro channel, the movement of $RBC+{\mu}Beads$ is controlled by the electrical AC input signal. The $RBC+{\mu}Beads$ having a micro-magnetic field captured above the GMR-SV device is changed as the output signals for detection status. From these results, the GMR-SV device having the width magnitude of a few micron size can be applied as the biosensor for the analysis of a new magnetic property as the membrane's deformation of RBC coupled to magnetic beads.

A Study on Analysis of Infrared Rotating Lovell Reticle Seeker and an Efficient Counter-countermeasure Algorithm (적외선 회전 Lovell 레티클 탐색기의 성능 분석 및 효율적인 반대응 알고리즘에 대한 연구)

  • Kim, Sun-Kook;Han, Sung-Hyun;Hong, Hyun-Ki;Choi, Jong-Soo
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.11
    • /
    • pp.166-175
    • /
    • 1998
  • The previous simulation models of infra-red (IR) reticle seekers were performed in a static situation. However, in this paper, we develop a new simulation tool which is applicable in various cases, and propose an efficient counter-countermeasure (CCM) in the presence of countermeasures (CM) such as flares. The developed tool analyzes performance of rotating Lovell reticle seeker, and gives tracking performances in various scenarios. The simulation results show that our counter-countermeasure algorithm makes an efficient target tracking in the presence of flares.

  • PDF

The Environmental Control of $Er^{3+}$ ions in $R-SiO_2/ZrO_2$ Sol-Gel Matrix ($R-SiO_2/ZrO_2$ 졸-겔 재료내 $Er^{3+}$이온의 결합 환경 제어)

  • 김주현;권정오;석상일;안복엽
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.224-224
    • /
    • 2003
  • 광통신을 위한 구성 요소는 빛을 발생시키는 발광소자, 빛을 검출하는 수광소자 그리고 광신호를 처리하는 광신호처리 소자로 구성된다. 이때 각 소자간 광전송과 광소자에 의한 광 신호 처리 과정에서 광전송 손실이 심각하게 일어나 광정보를 상실하게 되므로 각 요소별로 광신호 증폭이 반드시 필요하다. 뿐만 아니라 완전 광화에 의한 초고속/대용량 광통신망의 구축에는 저가이며, 광집적화가 가능한 광도파로형 광증폭기가 요구되고 있다. 짧은 거리에 높은 증폭 효율을 얻기 위한 광도파로형 광증폭기를 구현하기 위해서는 광통신 파장대인 1.55$\mu\textrm{m}$ 대역의 증폭이 가능한 Er 이온을 고농도로 도핑 할 필요가 있다. 그러나 Er 이온을 단순히 고농도로 첨가하면 Er-Er 간 뭉침 현상에 의해 더 이상의 증폭이 어렵게 된다. 본 연구에서는 이러한 문제를 해결하면서 스핀 코팅이 가능하여 저가 공정이 가능한 유/무기 졸-겔 재료 내에 Er 이온을 제어된 방법으로 첨가하고 그 결합 환경을 FT-IR 및 $^{17}$ O-NMR로 분석하였다. 유/무기 졸겔 재료 제조를 위하여 먼저 MPTS(MethAcryoxyPropylTrimethoxySilane)를 부분 가수분해한 후 ZrOCl$_2$.8$_2$O (Zirconyl Chloride Octahydrate) 와 ErCl$_3$. 6$H_2O$ (Erbium(III) Chloride Hexahydrate)를 순차적으로 결합시키고, Zr/MPTS 및 Zr/Er의 첨가비에 따른 발광 특성을 PL(photoluminescence) 스팩트럼으로 분석하여 Er 이온의 주위 결합 환경이 PL에 미치는 영향을 조사하였다. 또한 Si 기판에 코팅한 Er이 도핑된 유/무기 하이브리드 졸-겔 코팅막의 굴절율 등 광도파로 재료로서의 특성도 프리즘 커플러 등을 이용하여 조사하였다.

  • PDF

Two-step Boundary Extraction Algorithm with Model (모델 정보를 이용한 2단계 윤곽선 추출 기법)

  • Choe, Hae-Cheol;Lee, Jin-Seong;Jo, Ju-Hyeon;Sin, Ho-Cheol;Kim, Seung-Dae
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • We propose an algorithm for extracting the boundary of a desired object with shape information obtained from sample images. Considering global shape obtained from sample images and edge orientation as well as edge magnitude, the Proposed method composed of two steps finds the boundary of an object. The first step is the approximate segmentation that extracts a rough boundary with a probability map and an edge map. And the second step is the detailed segmentation for finding more accurate boundary based on the SEEL (seed-point extraction and edge linking) algorithm. The experiment results using IR images show robustness to low-quality image and better performance than conventional segmentation methods.

Development and Feasibility Evaluation of CsPbBr3 Dosimeter for Brachytherapy (근접방사선치료용 CsPbBr3 선량계 제작 및 적용가능성 평가)

  • Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.405-410
    • /
    • 2022
  • In brachytherapy, a radiation source is inserted into the body to kill tumor tissue. Therefore, it is important to accurately measure the location of the source and the dose distribution. In this study, a dosimeter that can be used for brachytherapy was developed using CsPbBr3 which is cheaper than the existing detector materials and has a simpler manufacturing process. The CsPbBr3 dosimeter performance was evaluated by analyzing reproducibility, linearity, and distance dependence in 192Ir source. As a result of reproducibility evaluation, the RSD was 1.36%, which satisfies the standard value of 1.5%. As a result of the linearity evaluation, the R2 value was 0.9993, which satisfies the standard R2 of 0.9990. The distance dependence evaluation showed a signal value that decreased exponentially as the distance increased. The evaluation results show that the CsPbBr3 dosimeter satisfies the evaluation criteria and can be used as a brachytherapy quality assurance dosimeter.