• 제목/요약/키워드: IPS Empress 2

검색결과 79건 처리시간 0.025초

The effect of repeated firings on the color change of dental ceramics using different glazing methods

  • Yilmaz, Kerem;Gonuldas, Fehmi;Ozturk, Caner
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.427-433
    • /
    • 2014
  • PURPOSE. Surface color is one of the main criteria to obtain an ideal esthetic. Many factors such as the type of the material, surface specifications, number of firings, firing temperature and thickness of the porcelain are all important to provide an unchanged surface color in dental ceramics. The aim of this study was to evaluate the color changes in dental ceramics according to the material type and glazing methods, during the multiple firings. MATERIALS AND METHODS. Three different types of dental ceramics (IPS Classical metal ceramic, Empress Esthetic and Empress 2 ceramics) were used in the study. Porcelains were evaluated under five main groups according to glaze and natural glaze methods. Color changes (${\Delta}E$) and changes in color parameters (${\Delta}L$, ${\Delta}a$, ${\Delta}b$) were determined using colorimeter during the control, the first, third, fifth, and seventh firings. The statistical analysis of the results was performed using ANOVA and Tukey test. RESULTS. The color changes which occurred upon material-method-firing interaction were statistically significant (P<.05). ${\Delta}E$, ${\Delta}L$, ${\Delta}a$ and ${\Delta}b$ values also demonstrated a negative trend. The MC-G group was less affected in terms of color changes compared to other groups. In all-ceramic specimens, the surface color was significantly affected by multiple firings. CONCLUSION. Firing detrimentally affected the structure of the porcelain surface and hence caused fading of the color and prominence of yellow and red characters. Compressible all-ceramics were remarkably affected by repeated firings due to their crystalline structure.

상악중절치에서 전부도재관의 finish line형태에 따른 파절강도와 응력 분포에 관한 연구 (THE FRACTURE RESISTANCE AND STRESS DISTRIBUTION OF ALL CERAMIC CROWNS WITH TWO TYPES OF FINISH LINE ON MAXILLARY CENTRAL INCISOR)

  • 기태석;김계순;이진한;김유리;동진근
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.405-420
    • /
    • 2003
  • Purpose : The purpose of this study was to compare the fracture resistance of the IPS Empress ceramic crown with 1.0mm width rounded shoulder, which is usually recommended in all ceramic crown. and 0.5mm width chamfer finish lines on the maxillary central incisor. Material and method : After 15 metal dies were made for each group, the IPS Empress all ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan) on the metal die. The cemented crowns were mounted on the positioning jig and the universal testing machine(Zwick Z020, Zwick Co. Germany)was used to measure the fracture strength with loading on the incisal edge. And also, three-dimensional finite element stress analysis was used to measure the stress distribution with the various types of the finish lines(1.0mm width rounded shoulder, 0.5mm width chamfer), the loading site(incisal edge, incisal $\frac{1}{3}$) and the type of loading(concentration loading, distribution loading). Results and conclusion : 1. In the fracture resistance experiment according to the finish line, the mean fracture strength of rounded shoulder(876N) and the mean fracture strength of chamfer(882N) did not skew any significant difference between each other(p>0.05). 2. The stress distribution of all ceramic crown in three dimensional finite element analysis showed concentration aspect at loading point and cervical area or labial surface. 3. In metal die, there were no differences in stress distribution between finish lines, but in natural teeth model, chamfer finish line showed higher stress than rounded shoulder finish line. 4. When force was loaded on the incisal edge the stress was concentrated on the incisal edge and the cervical area of labial surface. When force was loaded on the incisal $\frac{1}{3}$, the stress concentrated on the cervical area of labial surface and the cingulum area. 5. Generally, natural teeth model showed higher and various stress than the metal die.

불산 처리 시간이 강화형 전부도재관과 레진 시멘트의 전단 결합강도에 미치는 영향 (EFFECT OF ETCHING TIME ON SHEAR BOND STRENGTH OF RESIN CEMENTS TO REINFORCED ALL-CERAMIC CROWNS)

  • 김경일;최근배;안승근;박찬운
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.501-513
    • /
    • 2004
  • Purpose : The purpose of this study was to evaluate the effects of etching time on shear bond strength of four resin cements to IPS Empress 2 ceramic. Material and Methods: Forty rectangular shape ceramic specimens ($10{\times}15{\times}3.5mm$ size) were used for this study. The ceramic specimens divided into four groups and were etched with 10% hydrofluoric acid for 0, 10, 30, 60, 180, 300, 420, 600, and 900 seconds respectively. Etched surfaces of ceramic specimens were coated with ceramic adhesive system and bonded with four resin cement (Variolink II, Panavia F, Panavia 21, Super-Bond C&B) using acrylic glass tube. All cemented specimens were tested under shear loading untill fracture on universal testing machine at a crosshead speed 1mm/min: the maximum load at fracture (kg) was recored. Shear bond strengh data were analyzed with oneway analysis of variance and Tukey HSD tests (p<.05). Etched ceramic surfaces (0-, 60-, 300-, and 600-seconds etching period) and fracture surfaces after shear testing were examined mophologically using scanning electron microscopy. Results : Ceramic surface treatment with 10% hydrofluoric acid improved the bond strength of three resin cement except for Super-Bond C&B cement. Variolink II (41.0$\pm$2.4 MPa) resin cement at 300-seconds etching time showed statistically higher shear bond strength than the other resin cements (Panavia F: 28.3$\pm$2.3 MPa, Panavia 21: 21.5$\pm$2.2 MPa, Super-Bond C&B: 16.7$\pm$1.6 MPa). Ceramic surface etched with 10% hydrofluoric acid for 300 seconds showed more retentive surface texture. Conclusion: Within the limitation of this study, Variolink II resin cement are suitable for cementation of Empress 2 all-ceramic restorations and etching with 10% hydrofluoric acid for 180 to 300 seconds is required to enhance the bond strength.

금속선 강화에 따른 열 가압 도재의 파절저항 (The fracture resistance of heat pressed ceramics with wire reinforcement)

  • 조득원;동진근;오상천;김유리
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.191-198
    • /
    • 2009
  • 연구목적: 본 연구는 높은 심미성을 나타내지만 낮은 파절 강도로 인하여 구치부에서의 사용이 제한되고 있는 전부도재 고정성 국소의치의 파절강도를 증가시키기 위한 방법으로, 취성 재료인 도재에 인장강도가 높은 금속선을 삽입하고 물리적, 기계적 성질을 알아보고자 하였다. 연구 재료 및 방법: lithium disilicate(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Lichtenstein)와 0.41 mm 직경의 Ni-Cr 금속선(Alfa Aesar, Johnson Matthey Company, USA)을 사용하여, 금속선의 수와 배열을 달리한 4개의 실험군 시편을 제작하였다. 모든 시편은 폭 4 mm, 두께 2 mm, 길이 15 mm의 직육면체로 제작하였다. 실험군 1, 2, 3은 각각 한 가닥, 두 가닥, 세 가닥의 금속선을 도재 시편의 장축을 따라 배열하였으며, 실험군 4는 세 가닥의 금속선을 도재 시편의 장축에, 다섯 가닥의 금속선을 도재 시편의 횡축에 배열하였다. 대조군에는 금속선을 삽입하지 않았으며, 대조군 및 각각의 실험군의 시편은 각 군당 12개로 하였다. 결과: 만능 시험기(Z020, Zwick, Germany)를 이용하여 파절시점까지 하중을 가한 후, 굴곡계수, 굴곡강도, 파절시점까지의 변형률, 파괴인성을 측정하였다. 파절된 시편의 도재와 금속선의 계면을 횡절단 및 연마하여 주사전자현미경(JSM-6360, JEOL, Japan)으로 100배상에서 관찰하였다. 결과는 다음과 같다. 1. 도재에 금속선을 삽입한 결과, 금속선을 삽입하지 않은 대조군에 비해 통계적 유의성 있는 굴곡계수 및 굴곡강도의 변화는 관찰할 수 없었으나, 변형률의 유의성 있는 증가(P<.001)를 관찰할 수 있었다. 2. 금속선을 삽입한 시편의 파절 양상은 하중점 부위에서 도재만 파절되는 양상을 나타내었다. 3. 금속선을 삽입한 도재의 파절된 시편을 횡절단 및 종절단하여 100 배상에서 주사전자현미경으로 촬영한 결과, 하중 시 도재의 파절 원인이 될 수 있는 도재 내부의 기포는 관찰되지 않았으며, 도재와 금속선 사이의 gap도 관찰되지 않았다. 결론: 금속선 삽입의 결과, 취성 재료인 도재의 통계적으로 유의성 있는 변형률의 증가를 관찰할 수 있었다. 그러나 구치부에서 금속선 강화 도재의 사용을 위해서는 굴곡계수 및 굴곡강도의 향상이 필요하다. 이를 위해서는 추가적 연구가 필요하다.

In vitro evaluation of the fracture resistance and microleakage of porcelain laminate veneers bonded to teeth with composite fillings after cyclic loading

  • Sadighpour, Leyla;Geramipanah, Farideh;Allahyari, Somayeh;Sichani, Babak Fallahi;Fard, Mohamd Javad Kharazi
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.278-284
    • /
    • 2014
  • PURPOSE. There is insufficient data regarding the durability of porcelain laminate veneers bonded to existing composite fillings. The aim of the present study was to evaluate the fracture resistance and microleakage of porcelain laminate veneers bonded to teeth with existing composite fillings. MATERIALS AND METHODS. Thirty maxillary central incisors were divided into three groups (for each group, n=10): intact teeth (NP), teeth with class III composite fillings (C3) and teeth with class IV cavities (C4). Porcelain laminate veneers were made using IPS-Empress ceramic and bonded with Panavia F2 resin cement. The microleakage of all of the specimens was tested before and after cyclic loading ($1{\times}10^6$ cycles, 1.2 Hz). The fracture resistance values (N) were measured using a universal testing machine, and the mode of failure was also examined. The statistical analyses were performed using one-way ANOVA and Tukey post hoc tests (${\alpha}=.05$). RESULTS. There was a significant difference in the mean microleakage of group C4 compared with group NT (P=.013). There was no significant difference in the fracture loads among the groups. CONCLUSION. The microleakage and failure loads of porcelain laminate veneers bonded to intact teeth and teeth with standard class III composite fillings were not significantly different.

The effect of IDS (immediate dentin sealing) on dentin bond strength under various thermocycling periods

  • Lee, sungbok Richard;Lee, Sang-Min;Park, Su-Jung;Lee, Suk-Won;Lee, Do Yun;Im, Byung-Jin;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.224-232
    • /
    • 2015
  • PURPOSE. The purpose of this study was to find out the effect of immediate dentin sealing (IDS) on bond strength of ceramic restoration under various thermocycling periods with DBA (dentin bonding agent system). MATERIALS AND METHODS. Fifty freshly extracted human mandibular third molars were divided into 5 groups (1 control and 4 experimental groups) of 10 teeth. We removed enamel layer of sound teeth and embedded them which will proceed to be IDS, using All Bond II. A thermocycling was applied to experimental groups for 1, 2, 7, 14 days respectively and was not applied to control group. IPS Empress II for ceramic was acid-etched with ceramic etchant (9.5% HF) and silane was applied. Each ceramic disc was bonded to specimens with Duo-link, dual curable resin cement by means of light curing for 100 seconds. After the cementation procedures, shear bond strength measurement and SEM analysis of the fractured surface were done. The data were analyzed with a one-way ANOVA and Tukey multiple comparison test (${\alpha}$=.05). RESULTS. There were no statistically significant differences between 4 experimental groups and control group, however the mean value started to decrease in group 7d, and group 14d showed the lowest mean bond strength in all groups. Also, group 7d and 14d showed distinct exposed dentin and collapsed hybrid layer was observed in SEM analysis. CONCLUSION. In the present study, it can be concluded that ceramic restorations like a laminate veneer restoration should be bonded using resin cement within one week after IDS procedure.

INFLUENCE OF INVESTMENT/CERAMIC INTERACTION LAYER ON INTERFACIAL TOUGHNESS OF BODY CERAMIC BONDED TO LITHIA-BASED CERAMIC

  • Park, Ju-Mi
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.683-689
    • /
    • 2006
  • Statement of problem. Interfacial toughness is important in the mechanical property of layered dental ceramics such as core-veneered all-ceramic dental materials. The interfaces between adjacent layers must be strongly bonded to prevent delamination, however the weak interface makes delamination by the growth of lateral cracks along the interface. Purpose. The purpose of this study was to determine the effect of the reaction layer on the interfacial fracture toughness of the core/veneer structure according to the five different divesting. Materials and methods. Thirty five heat-pressed Lithia-based ceramic core bars (IPS Empress 2), $20mm{\times}3mm{\times}2mm$ were made following the five different surface divesting conditions. G1 was no dissolution or sandblasting of the interaction layer. G2 and G3 were dissolved layer with 0.2% HF in an ultrasonic unit for 15min and 30 min. G4 and G5 were dissolved layer for 15min and 30min and then same sandblasting for 60s each. We veneered bilayered ceramic bars, $20mm{\times}2.8mm{\times}3.8mm$(2mm core and 1.8mm veneer), according to the manufacturer's instruction. After polishing the specimens through $1{\mu}m$ alumina, we induced five cracks for each of five groups within the veneer close to interface under an applied indenter load of 19.6N with a Vickers microhardness indenter. Results. The results from Vickers hardness were the percentage of delamination G1:55%, G2:50%, G3:35%, G4:0% and G5:0%. SEM examination showed that the mean thickness of the reaction layer were G1 $93.5{\pm}20.6{\mu}m$, G2 $69.9{\pm}14.3{\mu}m$, G3 $59.2{\pm}20.2{\mu}m$, G4 $0.61{\pm}1.44{\mu}m$ G5 $0{\pm}0{\mu}m$. The mean interfacial delamination crack lengths were G1 $131{\pm}54.5{\mu}m$, G2 $85.2{\pm}51.3{\mu}m$, and G3 $94.9{\pm}81.8{\mu}m$. One-way ANOVA showed that there was no statistically significant difference in interfacial crack length among G1, G2 and G3(p> 0.05). Conclusion. The investment reaction layer played important role at the interfacial toughness of body ceramic bonded to Lithia-based ceramic.

FRACTURE STRENGTH AND FRACTURE MODE OF RESIN ROOT ANALOGS RESTORED WITH VARIOUS POST AND CORE MATERIALS

  • Lee, Byung-Chul;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho;Lee, Sun-Hyung
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.287-295
    • /
    • 2002
  • Statement of Problem. Endodontically treated teeth frequently required posts and cores to provide retention and resistance form for crowns. In spite of excellent mechanical properties of metal post and core, its metallic color can be detected through all ceramic restorations occasionally. To solve esthetic problems of metal post and core zirconia post system has been introduced recently. Purpose. The purpose of this study was to examine the fracture strength and mode of resin root analogs restored with zirconia, gold and titanium posts with resin, ceramic and metal cores after cementation with metal crowns. Materials and methods. To avoid the morphological variations of natural teeth, 40 root analogs were fabricated with composite resin. Forty resin root analogs were randomly assigned to four groups according to post and core materials: Group A: cast gold post and core and complete cast crowns, as control. Group B: titanium posts (Parapost, Coltent/Whaledent Inc., NJ, USA) and composite resin cores. Group C: zirconia posts (Cosmopost, Ivoclar AG, Schaan/Liechtenstein) and composite resin cores Group D: zirconia posts and heat-pressed ceramic cores (IPS Empress Cosmo Ingots, Ivoclar AG) After thermocycling ($5^{\circ}C{\sim}55^{\circ}C$, 30 sec.), cyclic loading was applied at 3mm below the incisal edge on the palatal surfaces at an angle of 135 degree to the long axis (2Hz, 50N, 50000cycles). Fracture strength was measured by universal testing machine (Instron, High Wycombe, UK) and fracture pattern of restored resin root analogs was also evaluated. Results and conclusion. Within the limitations of this study following results were drawn. 1. Resin root analogs restored with zirconia posts and composite resins demonstrated lowest fracture strength among tested groups. 2. There was no significant difference in the fracture strength between zirconia posts and heat pressed glass ceramic cores and cast gold posts and cores 3. The fracture strength of resin root analogs restored with titanium posts and composite resin cores was lower than that of gold posts and cores. 4. The deep oblique fracture lines were dominantly observed in root analogs restored with cast gold post and core and zirconia post and heat-pressed ceramic core groups.

도재 수리시스템에 따른 도재와 복합레진의 전단결합강도 (SHEAR BOND STRENGTHS OF COMPOSITE RESIN TO PORCELAINS AMONG PORCELAIN REPAIR SYSTEMS)

  • 김경규;신상완;이정렬;김영수
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.419-430
    • /
    • 2007
  • Purpose: This in vitro study evaluated shear bond strengths of surface treatment porcelains with four porcelain repair systems simulating intraoral bonding of composite resin to feldspathic porcelain or pressable porcelain. Material and methods: Eighty Porcelain disks were prepared. Group A: forty disk specimens were fabricated with Feldspathic Porcelain($Omega^{(R)}900$, Vident, Menlo Park, CA, USA). Group B: forty disk specimens were fabricated with Pressable Porcelain(IPS Empress 2 ingot, Ivoclar-Vivadent, Schaan, Liechtenstein, Germany). Each groups was divided into 4 subgroups and composite resin cylinders were bonded to specimen with one of the following four systems: Clearfil Porcelain Bond(L. Morita, Tustin, CA, USA), Ulradent Porcelain Etch. (Ultradent, Salt Lake City UT, USA), Porcelain Liner-M(Sun Medical Co., Kyoto, Japan), Cimara Kit(Voco, Germany). After surface conditioning with one of the four porcelain repair systems substrate surfaces of the specimen were examined microscopically(SEM). Shear bond strengths of specimens for each subgroup were determined with a universal testing machine (5mm/min crosshead speed) after storing them in distilled water at $37{\pm}1^{\circ}C$ for 24 hours. Stress at failure was measured in $MP_a$, and mode of failure was recorded. Differences among four repair systems were analyzed with two way ANOVA and Duncan test at the 95% significance level. Results: In the scanning electron photomicrograph of the treated porcelain surface, hydrofluoric acid etched group appeared the highest roughness. The shear bond strength of the phosphoric acid etched group was not significantly(p>0.05) different between feldspathic porcelain and pressable porcelain. But in no treatment and roughened with a bur group, the shear bond strength of the feldspathic porcelain was significantly higher than that of the pressable porcelain. In hydrofluoric acid etched group, the shear bond strength of the pressable porcelain was significantly higher(p<0.05). Conclusion: 1. Treatment groups showed significantly greater shear bond strengths than no treatment group(p<0.05). 2. Group with more roughened porcelain surface did not always show higher shear bond strengths. 3. In phosphoric acid etched group, there was no significant difference in shear bond strength between feldspathic porcelain and pressable porcelain(p>0.05). However in the other groups, there were significant differences in shear bond strengths between feldspathic porcelain and pressable porcelain(p<0.05).