• Title/Summary/Keyword: IP cassette

Search Result 9, Processing Time 0.031 seconds

Infection Control of Computed Radiography Portable in Radiology (영상의학과 이동촬영장비의 감염 관리)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2017
  • The purpose of this study is to prevent infection in the hospital by computed radiography portable and to provide basic data on infection-related education by investigating bacterial contamination level of computed radiography portable equipment using IP cassette. The results suggest that IP cassette No. 1 is infected with CNS and VRE, no. 2 with CNS, No. 3 with CNS and Pseudomonas aeruginosa, No. 4 with CNS, No. 5 with CNS and Bacillus sp., and No. 6 with enterococcus faecium. Enterococcus faecium and bacillus sp. were detected from the IP reader and Acinetobacter baumannii was detected on the mobile handle; Bacillus sp. on the control buttons, CNS and Bacillus sp. from the irradiation control handle, Acinetobacter baumannii on the x-ray generation switch, and CNS on the barcode scanner. In addition, Bacillus sp. Acinetobacter baumannii was found on the IP cassette mobile table and CNS and bacillus sp. were found on the lead apron. Acinetobacter baumannii and CNS were detected from the medical gloves worn by a radiological technologist during radiography. This suggests that IP cassette should be sterilized after use as it can hand over bacteria to IP reader and IP mobile table. Medical gloves that are in direct contact with patients should also be replaced after using them once and other supplies such as x-ray generation switch and lead apron should thoroughly be sterilized to prevent infection due to radiography as they are in a lot of contact with patients.

Back Scatter Radiation이 CR영상(影像)에 미치는 영향(影響)

  • Lee, Hu-Min;Kim, Hak-Seong;Jo, Nam-Su;Go, Seung-Il
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.2 no.1
    • /
    • pp.92-95
    • /
    • 1996
  • Computed Radiography(CR) is a relatively new technology that relies on an image plate(IP) as an alternate x-ray sensor to screen/film. Standard CR cassettes do not have lead foil behind the IP to control scatter radiation. The result of this study indicate that such control is needed. In most screen/film cassettes, that lines the rear of the cassette eliminates back scatter radiation. This study was performed to Investigate on the effects of back scatter in CR images by size of exposure field, distance between the CR cassette and the wall of radiography room. 1. It showed artifacts from hinges and clips located on the back of CR cassette by back scatter radiation. 2. The greater effects of back scatter radiation in CR images was attributed to the greater size of exposure field and the longer distance between the CR cassette and the wall of radiography room.

  • PDF

A Study on the Measurement of the Pollution Level of Bacteria and Disinfection of Table and IP Cassette (촬영 테이블과 IP Cassette의 세균 오염도 측정 및 소독에 관한 연구)

  • Bae, Seok-Hwan;Lee, Moo-Sik;Lim, Chang-Seon;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.229-237
    • /
    • 2008
  • Purpose : For the number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories, after identifying the bacteria before and after using alcohol and tissue including disinfectant and statistically testing, this research was intended to provide the basic data for the prevention and the right disinfection guideline for infection management of hospitals in diagnostic radiology. Subject and Method : The subject of this research was the general room of diagnostic radiology of a university hospital in Daejeon City. The research was conducted from Apr 5 to Apr 12, 2007. The number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories were tested before and after using alcohol and tissue for disinfection including disinfectant. In order to collect specimens exactly, they were collected with the nurse who specialized in infection management of the hospital, and statistical processing was done with SPSS V13.0. To compare the results before and after using alcohol and tissue, T-test was implemented, and post-hoc test was conducted. Results : Bacteria were detected in 19 cases of 24 subjects(79.2%), however, they were not detected in 5 cases(20.8%). 7kinds of bacteria were detected as isolated bacteria, of which Methicillin Resistant coagulase-negative Staphylococci(MRCNS) were detected in 15 cases(62.5%), which was most, Methicillin Resistant Staphylococcus Aureus(MRSA) in 6 cases(16.7%), Enterococcus Faecium(EFM) in 5 cases(20.8%), Acinetobacter baumannii(ABA) in 2 cases(8.3%), and Bacillus sp, Coagulase-negative Staphylococci(CNS), and Enterococcus sp(ENT) in 1 case, respectively(4.2%). In all bacteria except ABA, Gram positive bacillia were detected in 30 cases(97%), and Gram negative bacilli were detected only in 1 case(3%). As for the kinds of bacteria and the number of groups before and after using 70% Alcohol by Groups, when the bacteria were identified after disinfecting IP Cassette and Table with 70% Alcohol, all the bacteria became extinct in both IP Cassette and Table Group(100%). As for the kinds and number of bacteria before and after using Tissue Cleaner by Groups, the bacteria in Tissue Cleaner Group became completely extinct only in 10 Groups(71.2%), and in 4 Groups, there was much decrease in bacteria, however, they were still detected. The extinction rate of all the bacteria was 91.5%. That is, though the other bacteria became extinct(100%), that of MRCNS bacteria was lowest(83.6%), followed by MRSA(95%). Conclusion : As a result of comparing the mean of the bacteria which were detected before and after using 70% Alcohol and Tissue Cleaner, there was statistically significant in the significant level of 5% in both of them.

  • PDF

A Convergence Study on the Contamination and Disinfection of General X-ray generator Practical Equipment (일반촬영 실습 장비의 오염 및 소독에 관한 융합적 연구)

  • Park, Gyu-Tae;Kim, Dong-Heun;Park, Sang-Hee;Jung, Won-Hee;Kim, So-Yeon;Hong, Hee-Jin;Son, Na-Ra;Nam, Seoul-Hee;Han, Man-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 2020
  • It is going to select one X-ray generating device for diagnosis in a radiography laboratory at K university in Gangwon-do to detect bacteria on the surface contamination of tables, IP cassettes, and lead gowns for medical radiation shielding and to inform students of the need for proper disinfection control and hand hygiene. Then disinfection was carried out with tissue, tissue cleaner and 70% alchol and immediately collected with sterile cotton swabs to assess the contamination distribution status and disinfection effects of the surface. The results of measuring the degree of contamination on the surface showed that the largest number of bacteria were detected in Apron, and the evaluation of the disinfection effects according to surface contamination showed a noticeable effect at 70% Alcohol in IP Cassette, and the disinfection effect was the same for Apron. Therefore, in order to prevent bacterial infections among students, basic hand washing and regular disinfection should be performed before the practice to prevent infection.

Development of Digital Endoscopic Image Processing System (디지탈 내시경 영상처리 시스템의 개발)

  • 송철규;이영묵
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.121-126
    • /
    • 1997
  • Endoscopy has become a crucial diagnostic and therapeutic procedure in clinical areas. Over the past three years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholecystectomy, pelviscopic endometriosis, and surgical arthroscopy. In this study, we developed a computer system, which is composed of a frame yabber, a sound board, a VCR control board, a LAN card and EDMS(endoscopic data management software. Also, computer system has controled peripheral instruments such as a color video printer, a video cassette recorder, and endoscopic input/output signals(image and doctor's comment). Digital endoscopic data management system is based on open architecture and a set of widely available industry standards, namely: windows 3.1 as a operating system, TCP/IP as a network protocol and a time sequence based database that handles both images and doctor's cotnments. For the purpose of data storage, we used MOD and CD-R. Digital endoscopic system was designed to be able to store, recreate, change, and compress signals and medical images.

  • PDF

Cooperative transcriptional activation of ATP-binding cassette sterol transporters ABCG5 and ABCG8 genes by nuclear receptors including Liver-X-Receptor

  • Back, Su Sun;Kim, Jinsu;Choi, Daehyung;Lee, Eui Sup;Choi, Soo Young;Han, Kyuhyung
    • BMB Reports
    • /
    • v.46 no.6
    • /
    • pp.322-327
    • /
    • 2013
  • The ATP-binding cassette transporters ABCG5 and ABCG8 form heterodimers that limit absorption of dietary sterols in the intestine and promote cholesterol elimination from the body through hepatobiliary secretion. To identify cis-regulatory elements of the two genes, we have cloned and analyzed twenty-three evolutionary conserved region (ECR) fragments using the CMV-luciferase reporter system in HepG2 cells. Two ECRs were found to be responsive to the Liver-X-Receptor (LXR). Through elaborate deletion studies, regions containing putative LXREs were identified and the binding of $LXR{\alpha}$ was demonstrated by EMSA and ChIP assay. When the LXREs were inserted upstream of the intergenic promoter, synergistic activation by $LXR{\alpha}/RXR{\alpha}$ in combination with GATA4, $HNF4{\alpha}$, and LRH-1, which had been shown to bind to the intergenic region, was observed. In conclusion, we have identified two LXREs in ABCG5/ABCG8 genes for the first time and propose that these LXREs, especially in the ECR20, play major roles in regulating these genes.

A Design and Implementation of Personal VOD System using Multi-thread (다중 스래드를 이용한 개인용 VOD 시스템의 설계와 구현)

  • Park, Sung-Sik;Lee, Ho-Suk
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.6 no.3
    • /
    • pp.299-310
    • /
    • 2000
  • In this paper, we designed and implemented a personal VOD server using multi-thread for the real-time services of video data to the users. The system consists of service manager, disk manager, and network manager. The service manager controls the user admission to the system using the VBR(Variable Bit Rate) characteristics of MPEG (Moving Picture Experts Group) video data. The disk manager provides the functions for VCR-like operations. The disk manager reads blocks from the disk by the size of GOP(Group of Pictures) and buffers the data to the user's thread. The network manager uses TCP/IP for the communication between the server and the client. The communication starts from the client and the VOD server must respond to this request. The implemented personal VOD system shows an acceptable performance.

  • PDF

Development of Digital Endoscopic Data Management System (디지탈 내시경 데이터 management system의 개발)

  • Song, C.G.;Lee, S.M.;Lee, Y.M.;Kim, W.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.304-306
    • /
    • 1996
  • Endoscopy has become a crucial diagnostic and theraputic procedure in clinical areas. Over the past three years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholesystectomy, peviscopic endometriosis, and surgical arthroscopy. In this study, we are developed computer system, which is composed of frame grabber, sound board, VCR control board, LAN card and EDMS(endoscopic data management software). Also, computer system has controled over peripheral instruments as a color video printer, video cassette recorder, and endoscopic input/output signals(image and doctor's speech). Also, we are developed one body system of camels control unit including an endoscopic miniature camera and light source. Our system offer unsurpassed image quality in terms of resolution and color fidelity. Digital endoscopic data management system is based on open architecture and a set of widely available industry standards, namely: windows 3.1 as a operating system, TCP/IP as a network protocol and a time sequence based database that handles both an image and drctor's speech synchronized with endoscopic image.

  • PDF